Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Mechanistic Study of Lead Adsorption on Activated Carbon

Activated carbon (AC) is a carbonaceous material broadly applied in filters to remove lead (Pb(II)) from drinking water through adsorption. However, the chemical interactions between Pb(II) and the reactive sites on AC or other carbonaceous materials are not well understood, yet. The understanding of the mechanism of Pb(II) adsorption onto AC would allow to optimally design AC-based materials even in the presence of a complex liquid phase. Here in this paper, the interaction between Pb(II) and functional groups on AC was investigated at the molecular scale to help identifying the chemical reactions at the solid-liquid interface. Spectroscopic analyses and chemical quantum calculations were performed and indicated the formation of monodentate mononuclear Pb(II)-phenol and bidentate mononuclear Pb(II)-carboxyl complexes on AC. Competitive adsorption behavior was observed between Pb(II) and calcium (Ca(II)) because of their similar adsorption configurations on AC. In contrast, anions, including sulfate and phosphate, were observed to enhance Pb(II) adsorption on AC by forming ternary complexes. On the basis of these observations, a new surface complexation model of Pb(II) adsorption onto AC was formulated and validated with batch tests. Overall, this work presents a new set of chemical reactions at the solid-liquid interface between Pb(II) and AC under various conditions of interest for the application of AC or other carbonaceous materials in water treatment.

36 MATERIALS SCIENCE↗

Synthesis and Characterization of the Actinium Aquo Ion

Metal aquo ions occupy central roles in all equilibria that define metal complexation in natural environments. These complexes are used to establish thermodynamic metrics (i.e., stability constants) for predicting metal binding, which are essential for defining critical parameters associated with aqueous speciation, metal chelation, in vivo transport, and so on. As such, establishing the fundamental chemistry of the actinium(III) aquo ion (Ac-aquo ion, Ac(H 2 O) x 3+ ) is critical for current efforts to develop 225 Ac [t 1/2 = 10.0(1) d] as a targeted anticancer therapeutic agent. However, given the limited amount of actinium available for study and its high radioactivity, many aspects of actinium chemistry remain poorly defined. We overcame these challenges using the longer-lived 227 Ac [t 1/2 = 21.772(3) y] isotope and report the first characterization of this fundamentally important Ac-aquo coordination complex. Our X-ray absorption fine structure study revealed 10.9 ± 0.5 water molecules directly coordinated to the Ac III cation with an Ac–O H2O distance of 2.63(1) Å. This experimentally determined distance was consistent with molecular dynamics density functional theory results that showed (over the course of 8 ps) that Ac III was coordinated by 9 water molecules with Ac–O H2O distances ranging from 2.61 to 2.76 Å. Lastly, the data is presented in the context of other actinide(III) and lanthanide(III) aquo ions characterized by XAFS and highlights the uniqueness of the large Ac III coordination numbers and long Ac–O H2O bond distances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sulfurospirillum diekertiae sp. nov., a tetrachloroethene-respiring bacterium isolated from contaminated soil

Two anaerobic, tetrachloroethene- (PCE-) respiring bacterial isolates, designated strain ACS DCE T and strain ACS TCE , were characterized using a polyphasic approach. Cells were Gram-stain-negative, motile, non-spore-forming and shared a vibrioid- to spirillum-shaped morphology. Optimum growth occurred at 30°C and 0.1–0.4% salinity. The pH range for growth was pH 5.5–7.5, with an optimum at pH 7.2. Hydrogen, formate, pyruvate and lactate as electron donors supported respiratory reductive dechlorination of PCE to cis-1,2-dichloroethene (cDCE) in strain ACS DCE T and of PCE to trichloroethene (TCE) in strain ACS TCE . Both strains were able to grow with pyruvate under microaerobic conditions. Nitrate, elemental sulphur, and thiosulphate were alternative electron acceptors. Autotrophic growth was not observed and acetate served as carbon source for both strains. The major cellular fatty acids were C 16:1 ω7c, C 16:0 , C 14:0 and C 18:1 ω7c. Both genomes feature a circular plasmid. Strains ACS DCE T and ACS TCE were previously assigned to the candidate species 'Sulfurospirillum acididehalogenans'. Here, based on key genomic features and pairwise comparisons of whole-genome sequences, including average nucleotide identity, digital DNA–DNA hybridization and average amino acid identity, strains ACS DCE T and ACS TCE , 'Ca. Sulfurospirillum diekertiae' strains SL2-1 and SL2-2, and the unclassified Sulfurospirillum sp. strain SPD-1 are grouped into one distinct species separate from previously described Sulfurospirillum species. Compared to Sulfurospirillum multivorans and Sulfurospirillum halorespirans, which dechlorinate PCE to cDCE without substantial TCE accumulation, these five strains produce TCE or cDCE as the end product. In addition, some cellular fatty acids (e.g., C 16:0 3OH, C 17:0 iso 3OH, C 17:0 2OH) were detected in strains ACS DCE T and ACS TCE but not in other Sulfurospirillum species. On the basis of phylogenetic, physiological and phenotypic characteristics, 'Ca. Sulfurospirillum acididehalogenans' and 'Ca. Sulfurospirillum diekertiae' are proposed to be merged into one novel species within the genus Sulfurospirillum, for which the name Sulfurospirillum diekertiae sp. nov. is proposed. Finally, the type strain is ACS DCE T (=JCM 33349 T = KCTC 15819 T =CGMCC 1.5292 T ).

59 BASIC BIOLOGICAL SCIENCES↗

MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

60 APPLIED LIFE SCIENCES↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

Application of ion exchange and extraction chromatography to the separation of actinium from proton-irradiated thorium metal for analytical purposes

We present that actinium-225 (t 1/2 = 9.92 d) is an α-emitting radionuclide with nuclear properties well-suited for use in targeted alpha therapy (TAT), a powerful treatment method for malignant tumors. Actinium-225 can also be utilized as a generator for 213 Bi (t 1/2 45.6 min), which is another valuable candidate for TAT. Actinium-225 can be produced via proton irradiation of thorium metal; however, long-lived 227 Ac (t 1/2 = 21.8 a, 99% β - , 1% α) is co-produced during this process and will impact the quality of the final product. Thus, accurate assays are needed to determine the 225 Ac/ 227 Ac ratio, which is dependent on beam energy, irradiation time and target design. Accurate actinium assays, in turn, require efficient separation of actinium isotopes from both the Th matrix and highly radioactive activation by-products, especially radiolanthanides formed from proton-induced fission. In this study, we introduce a novel, selective chromatographic technique for the recovery and purification of actinium isotopes from irradiated Th matrices. A two-step sequence of cation exchange and extraction chromatography was implemented. Radiolanthanides were quantitatively removed from Ac, and no non-Ac radionuclidic impurities were detected in the final Ac fraction. An 225 Ac spike added prior to separation was recovered at ≥98%, and Ac decontamination from Th was found to be ≥10 6 . Finally, the purified actinium fraction allowed for highly accurate 227 Ac determination at analytical scales, i.e., at 227 Ac activities of 1–100 kBq (27 nCi to 2.7 μCi).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Mdr1a plays a crucial role in regulating the analgesic effect and toxicity of aconitine by altering its pharmacokinetic characteristics

Aconitine (AC) is the primary bioactive/toxic alkaloid in plants of the Aconitum species. Our previous study demonstrated that Mdr1 was involved in efflux of AC. However, the mechanism by which Mdr1 regulates the efficacy/toxicity of AC in vivo remains unclear. The present study aimed to determine the effects of Mdr1a on the efficacy/toxicity and pharmacokinetics of AC in wild-type and Mdr1a{sup −/−} FVB mice. After oral administration of AC, significantly higher analgesic effect was observed in Mdr1a{sup −/−} mice (49% to 105%) compared to wild-type mice (P < 0.05). The levels of s100-β protein and creatine kinase, which indicate cerebral and myocardial damage, respectively, were also significantly increased (P < 0.05) in Mdr1a{sup −/−} mice. Histopathological examination revealed that the Mdr1a{sup −/−} mice suffered from evident cerebral and myocardial damages, but the wild-type mice did not. These findings suggested that Mdr1a deficiency significantly promoted the analgesic effect of AC and exacerbated its toxicity. Pharmacokinetic experiments showed that T{sub 1/2} of AC in the Mdr1a{sup −/−} mice was significantly higher (from 87% to 300%) than that in wild-type mice (P < 0.05). The distribution of AC in the brain of Mdr1a{sup −/−} mice was 2- to 32-fold higher than that in the brains of wild-type mice (P < 0.05). Toxic reactions were more severe in Mdr1a{sup −/−} mice compared to wild-type mice. In conclusion, Mdr1a deficiency significantly enhanced the analgesic effect of AC and exacerbated its toxicity by upregulating its distribution to the brain and decreasing its plasma elimination rate. Thus, Mdr1a dysfunction may cause severe AC poisoning. - Highlights: • The efficacy and toxicity of aconitine were significantly enhanced in Mdr1a{sup −/−} mice. • The distribution of aconitine to the brain was remarkably increased in Mdr1a{sup −/−} mice. • The elimination rate of aconitine was significantly decreased in Mdr1a{sup −/−} mice.

60 APPLIED LIFE SCIENCES↗

KINEMATICS IN KAPTEYN'S SELECTED AREA 76: ORBITAL MOTIONS WITHIN THE HIGHLY SUBSTRUCTURED ANTICENTER STREAM

We have measured the mean three-dimensional kinematics of stars in Kapteyn's Selected Area (SA) 76 (l = 209.{sup 0}3, b = 26.{sup 0}4) that were selected to be Anticenter Stream (ACS) members on the basis of their radial velocities (RVs), proper motions (PMs), and location in the color-magnitude diagram. From a total of 31 stars ascertained to be ACS members primarily from its main-sequence turnoff, a mean ACS RV (derived from spectra obtained with the Hydra multi-object spectrograph on the WIYN 3.5 m telescope) of V{sub helio} = 97.0 {+-} 2.8 km s{sup -1} was determined, with an intrinsic velocity dispersion {sigma}{sub o} = 12.8 {+-} 2.1 km s{sup -1}. The mean absolute PMs of these 31 ACS members are {mu}{sub {alpha}} cos {delta} = -1.20 {+-} 0.34 mas yr{sup -1} and {mu}{sub {delta}} = -0.78 {+-} 0.36 mas yr{sup -1}. At a distance to the ACS of 10 {+-} 3 kpc, these measured kinematical quantities produce an orbit that deviates by {approx}30{sup 0} from the well-defined swath of stellar overdensity constituting the ACS in the western portion of the Sloan Digital Sky Survey footprint. We explore possible explanations for this and suggest that our data in SA 76 are measuring the motion of a kinematically cold sub-stream among the ACS debris that was likely a fragment of the same infalling structure that created the larger ACS system. The ACS is clearly separated spatially from the majority of claimed Monoceros ring detections in this region of the sky; however, with the data in hand, we are unable to either confirm or rule out an association between the ACS and the poorly understood Monoceros structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B{sub 0}) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B{sub 0} inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the computation time by obviating the need for iterative calculations of the PET emission data beyond those required for reconstructing images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerating Energy Efficiency Improvements in Room Air Conditioners in India: Potential, Costs-Benefits, and Policies

Rising incomes, increasing urbanization, and large cooling demand prompted by India’s hot, humid climate are driving increasing uptake of room air conditioners (ACs). Air conditioning already accounts for 40-60% of summer peak load in large Indian cities such as Delhi and is on track to contribute 140 gigawatts (GW) (~30%) to peak demand in 2030. India’s standards and labeling policies improved the market average efficiency of room ACs by about 35% between 2006 and 2016 (3% per year) even as inflation-adjusted room AC prices continued to decline. In this report, we assess the technical feasibility and costs and benefits of accelerating the efficiency improvement in room ACs in India and discuss policy enhancements needed to achieve this goal. We also describe examples of rapid AC efficiency improvement from Japan and Korea. Driven by appropriate policies and programs, AC efficiency in these countries improved by more than 8% per year, resulting in near-doubling of energy efficiency over seven to ten years while inflationadjusted AC prices declined. We also find that the most efficient room AC sold on the Indian market is almost twice as efficient as the average AC sold on the market in 2015-16. As a result, we conclude that the technology needed to accelerate room AC efficiency in India is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opportunities for Simultaneous Efficiency Improvement and Refrigerant Transition in Air Conditioning

In October of 2016, nearly 200 Parties agreed to amend the Montreal Protocol in Kigali, Rwanda, to phase-down consumption and production of hydrofluorocarbons (HFCs) by 2050. Growth in the use of HFCs, including those currently used as refrigerants in air-conditioning systems, is being driven by demand from emerging economies, hot climates, and rising incomes that are also undergoing rapid urbanization and electrification. Air conditioners (ACs), as an energy-intensive end-use technology, are also covered by a growing number of energy efficiency standards, labeling, procurement, incentive, and other supporting efficiency programs. Therefore, improving room AC energy efficiency and transitioning to low-global warming potential (GWP) refrigerants simultaneously presents significant opportunities to deploy energy efficient technology and reduce the energy and emissions impacts of room ACs, while keeping costs low for consumers. This report aims to provide an initial sense of the opportunities to improve efficiency and transition to low-GWP refrigerants by reviewing the HCFC and HFC regulatory framework and energy efficiency standards and labeling programs in 19 economies that account for roughly 65 percent of global room AC demand. Based on this analysis, we identified key opportunities for coordinated action on efficiency improvement and refrigerant transition for the domestic room AC sector (i.e., ductless mini-split ACs), such as: - implementing or revising standards and labeling programs to improve efficiency levels with the possibility of adding a low-GWP criterion. - combining fixed speed and inverter AC product categories to account for seasonal variations in climate and part-load operating conditions, and using seasonal energy efficiency ratio (SEER) instead of energy efficiency ratio (EER) to better reflect performance of inverter ACs. - implementing market transformation programs, such as bulk procurement programs, to drive down the costs of efficient technology through economies of scale. - aligning timelines for implementing efficiency standards with timelines for refrigerant management plans to coordinate policy actions. - maximizing the energy efficiency improvements of Montreal Protocol investments by coordinating efforts to help keep costs low for consumers and manufacturers during equipment redesign and manufacturing line retooling for refrigerant transition. In order to realize the significant peak load, energy saving and climate benefits of these opportunities associated with improving energy efficiency in tandem with the refrigerant transition, some risks may need to be mitigated, principally safety concerns over risks of accidental ignition with refrigerants rated flammable. This can be mitigated by continuing and accelerating the development of safety standards currently being updated, for example, by the International Electrotechnical Commission (IEC) and improving training for production, installation and maintenance during the use of flammable refrigerants. While some low-GWP refrigerants may cost more than the current baseline refrigerants, the cost of refrigerants is only ~1% of lifecycle costs for an AC. Costs can also be reduced through manufacturing advances and efficiency improvements, particularly if they are supported by policies that encourage technological development through deployment of superefficient ACs at scale. Finally, during the transition, there is a risk of obsolete technology being deployed in markets that either have not updated their standards or have later compliance dates. This risk can be mitigated by updating standards and reviewing them periodically to ensure their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capabilities of an Acoustic Camera to Inform Fish Collision Risk with Current Energy Converter Turbines

A diversified energy portfolio may include marine energy in the form of current energy converters (CECs) such as tidal or in-river turbines. New technology development in the research stage typically requires monitoring for environmental effects. A significant environmental effect of concern for CECs is the risk of moving parts (e.g., turbine blades) colliding with animals such as fishes. CECs are installed in energetic locations in which it is difficult to operate sensors to fulfill monitoring requirements for informing collision risk. Collecting data (i.e., about blade strikes or near-misses) that inform interactions of fishes with CECs is usually attempted using active acoustic sensors or video cameras (VCs). Limitations of low-light conditions or water turbidity that preclude effective use of VCs are overcome by using high-resolution multibeam echosounders (or acoustic cameras (ACs)). We used an AC at two sites to test its ability to detect artificial and real fish targets and determine if strike, near-miss, and near-field behavior could be observed. Interactions with fish and artificial targets with turbines have been documented but strike confirmation with an AC is novel. The first site was in a tidal estuary with a 25 kW turbine and water clarity sufficient to allow VC data to be collected concurrently with AC data showing turbine blade strike on tethered artificial fish targets. The second site was a turbid, debris-laden river with a 5 kW turbine where only AC data were collected due to high water turbidity. Data collection at the second site coincided with downstream Pacific salmon (Oncorhynchus spp.) smolt migration. Physical fish capture downstream of the turbine was performed with an incline plane trap (IPT) to provide context for the AC observations, by comparing fish catches. Discrimination between debris and fishes in the AC data was not possible, because active movement of fishes was not discernable. Nineteen fishes were released upstream of the turbine to provide known times of possible fish/turbine interactions, but detection was difficult to confirm in the AC data. ACs have been used extensively in past studies to count large migratory fish such as Pacific salmon, but their application for small fish targets has been limited. The results from these two field campaigns demonstrate the ability of ACs to detect targets in turbid water and observe blade strikes, as well as their limitations such as the difficulty of distinguishing small fishes from debris in a high-energy turbid river. Recommendations are presented for future applications associated with CEC device testing.

16 TIDAL AND WAVE POWER↗

Materials Data on AcMg5 by Materials Project

Mg5Ac crystallizes in the hexagonal P-62m space group. The structure is three-dimensional. there are four inequivalent Mg sites. In the first Mg site, Mg is bonded to eight Mg and four equivalent Ac atoms to form a mixture of distorted edge, face, and corner-sharing MgAc4Mg8 cuboctahedra. There are four shorter (3.07 Å) and four longer (3.08 Å) Mg–Mg bond lengths. There are two shorter (3.91 Å) and two longer (4.03 Å) Mg–Ac bond lengths. In the second Mg site, Mg is bonded in a 9-coordinate geometry to six Mg and three equivalent Ac atoms. All Mg–Mg bond lengths are 3.07 Å. All Mg–Ac bond lengths are 3.56 Å. In the third Mg site, Mg is bonded to eight Mg and four equivalent Ac atoms to form a mixture of distorted edge, face, and corner-sharing MgAc4Mg8 cuboctahedra. Both Mg–Mg bond lengths are 3.08 Å. There are two shorter (3.91 Å) and two longer (4.03 Å) Mg–Ac bond lengths. In the fourth Mg site, Mg is bonded to eight Mg and four equivalent Ac atoms to form a mixture of distorted edge, face, and corner-sharing MgAc4Mg8 cuboctahedra. There are two shorter (3.91 Å) and two longer (4.03 Å) Mg–Ac bond lengths. Ac is bonded in a 6-coordinate geometry to eighteen Mg atoms.

36 MATERIALS SCIENCE↗

Materials Data on Ac2Mg by Materials Project

Mg(Ac)2 crystallizes in the orthorhombic Cmcm space group. The structure is two-dimensional and consists of two Mg(Ac)2 sheets oriented in the (0, 1, 0) direction. Mg is bonded in a body-centered cubic geometry to eight Ac atoms. There are a spread of Mg–Ac bond distances ranging from 3.53–3.67 Å. There are two inequivalent Ac sites. In the first Ac site, Ac is bonded in a 12-coordinate geometry to two equivalent Mg atoms. In the second Ac site, Ac is bonded in a 6-coordinate geometry to six equivalent Mg atoms.

36 MATERIALS SCIENCE↗

Materials Data on Ac2Mg by Materials Project

Mg(Ac)2 crystallizes in the monoclinic C2/m space group. The structure is two-dimensional and consists of two Mg(Ac)2 sheets oriented in the (1, 0, 0) direction. Mg is bonded in a body-centered cubic geometry to eight Ac atoms. There are a spread of Mg–Ac bond distances ranging from 3.57–3.61 Å. There are two inequivalent Ac sites. In the first Ac site, Ac is bonded in a 4-coordinate geometry to four equivalent Mg atoms. In the second Ac site, Ac is bonded in a 12-coordinate geometry to four equivalent Mg atoms.

36 MATERIALS SCIENCE↗

Assessment of attenuation correction for myocardial PET imaging using combined PET/MRI

Objective: To evaluate the frequency of artifacts in MR-based attenuation correction (AC) maps and their impact on the quantitative accuracy of PET-based flow and metabolism measurements in a cohort of consecutive heart failure patients undergoing combined PET/MR imaging. Methods: Myocardial viability studies were performed in 20 patients following a dual-tracer protocol involving the assessment of myocardial perfusion ({sup 13}N-NH{sub 3}: 813 ± 86 MBq) and metabolism ({sup 18}F-FDG: 335 ± 38 MBq). All acquisitions were performed using a fully-integrated PET/MR system, with standard DIXON-attenuation correction (DIXON-AC) mapping for each PET scan. All AC maps were examined for spatial misalignment with the emission data, total lung volume, susceptibility artifacts, and tissue inversion (TI). Misalignment and susceptibility artifacts were corrected using rigid co-registration and retrospective filling of the susceptibility-induced gaps, respectively. The effects of the AC artifacts were evaluated by relative difference measures and perceived changes in clinical interpretations. Results: Average respiratory misalignment of (7 ± 4) mm of the PET-emission data and the AC maps was observed in 18 (90%) patients. Substantial changes in the lung volumes of the AC maps were observed in the test–retest analysis (ratio: 1.0 ± 0.2, range: 0.8-1.4). Susceptibility artifacts were observed in 10 (50%) patients, while six (30%) patients had TI artifacts. Average differences of 14 ± 10% were observed for PET images reconstructed with the artifactual AC maps. The combined artifact effects caused false-positive findings in three (15%) patients. Conclusion: Standard DIXON-AC maps must be examined carefully for artifacts and misalignment effects prior to AC correction of cardiac PET/MRI studies in order to avoid misinterpretation of biased perfusion and metabolism readings from the PET data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Dilute Acetic Acid Hydrolysis on Xylooligosaccharide Production and the Inhibitory Effect of Cellulolytic Enzyme Lignin from Poplar

Acetic acid (AC) hydrolysis has been reported to prepare xylooligosaccharides (XOS) from poplar. However, the influence of AC hydrolysis on the lignin structure changes is not clear, which is important for the following enzymatic hydrolysis of poplar. Herein, AC was used to produce XOS, and cellulase adsorption on cellulolytic enzyme lignin (CEL) from AC-hydrolyzed poplar and its inhibitory effect on two commercial cellulase preparations were investigated. AC hydrolysis gave a XOS yield of 39.8% from poplar. After AC hydrolysis at 170 °C, the hydrophobicity and ζ-potential of CEL decreased to 2.3 L/g and 14.8 mV, respectively. The adsorption strength of CTec2 on CEL samples did not increase by AC hydrolysis, and the inhibitory effect of CEL on Celluclast 1.5L and β-glucosidase was observed, but not on CTec2. CEL samples improved the lytic polysaccharide monooxygenase (LPMO) activity of the enzymatic hydrolysis by CTec2. After CEL samples were added in enzymatic hydrolysis, the free filter paper activity of Celluclast 1.5L and β-G retained in the enzymatic hydrolysate decreased from 60.5 to 29.3–42.9%. The addition of CEL samples in enzymatic hydrolysis could not decrease the free filter paper activity of CTec2 retained in the enzymatic hydrolysate. In the enzymatic hydrolysis with CEL samples, higher glucose yields were obtained by CTec2 than those by Celluclast 1.5L and β-glucosidase. This work will help to understand the structure and inhibitory effects of AC-CELs and guide the development of AC hydrolysis for the production of XOS and monosaccharides from poplar.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗