Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Quasi-Steady Acceleration Direction Indicator in Three Dimensions

Many materials processing and fluids physics experiments conducted in a microgravity environment require knowledge of the orientation of the low-frequency acceleration vector. This need becomes especially acute for space experiments such as directional solidification of a molten semiconductor, which is extremely sensitive to orientation and may involve tens of hours of operations of a materials furnace. These low-frequency acceleration data have been measured for many Shuttle missions with the Orbital Acceleration Research Experiment. Previous attempts at using fluid chambers for acceleration measurements have met with limited success due to pointing and vehicle attitude complications. An acceleration direction indicator is described, which is comprised of two orthogonal short cylinders of fluid, each with a small bubble. The motion and the position of the bubble within the chamber will indicate the direction of the acceleration experienced at the sensor location. The direction of the acceleration vector may then be calculated from these data. The frequency response of such an instrument may be tailored for particular experiments with the proper selection of fluid and gas parameters, surface type, and geometry. A three-dimensional system for sensing and displaying the low-frequency acceleration direction via an innovative technique described in this paper has advantages in terms of size, mass, and power compared with electronic instrumentation systems.

DeLombard, Richard↗

Observed changes in a-Si:H cell characteristics due to long term temperature stress

Determination of thermally induced degradation mechanisms affecting thin film amorphous silicon solar cells through the use of laboratory accelerated stress testing requires acquisition of specially constructed, individually addressable test cells and the development of highly repeatable instrumentation which is not influenced by short-term reversible optical effects. This paper illustrates these considerations by describing accelerated temperature stress procedures and test results for one type of a-Si:H cell. Observed electrical characteristic changes indicate that two types of stress induced mechanisms are operating - one of which is self limiting and can be observed at lower temperatures and one which continues to complete degradation. The self limiting mechanism can result in a dramatic improvement to cells having initially low Voc values.

Lathrop, Jay W.↗

An interface for the direct coupling of small liquid samples to AMS

We describe the moving wire interface attached to the 1-MV AMS system at LLNL’s Center for Accelerator Mass Spectrometry for the analysis of nonvolatile liquid samples as either discrete drops or from the direct output of biochemical separatory instrumentation, such as high-performance liquid chromatography (HPLC). Discrete samples containing at least a few 10 s of nanograms of carbon and as little as 50 zmol 14 C can be measured with a 3–5% precision in a few minutes. The dynamic range of our system spans approximately 3 orders in magnitude. Sample to sample memory is minimized by the use of fresh targets for each discrete sample or by minimizing the amount of carbon present in a peak generated by an HPLC containing a significant amount of 14 C. As a result, liquid sample AMS provides a new technology to expand our biomedical AMS program by enabling the capability to measure low-level biochemicals in extremely small samples that would otherwise be inaccessible.

14C↗

Development of a High-Energy Neutron Sniffer and Subsequent Dose Quantification for High-Energy Particle Accelerator Shielding Surveys

The objective of this research is to design a portable neutron detector that is lightweight and responds to neutrons with energies of 20 MeV and greater. The instrument will be used as a ‘sniffer’ probe for identifying shielding weaknesses at high-energy particle accelerators and be paired with a plastic scintillator to quantify the high-energy neutron dose equivalent. The sniffer probes are two different sizes and comprised of either cesium iodide or sodium iodide, all doped with thallium, making a total of four detectors. The probes were calibrated to respond only to radiations with 8 MeV electron equivalent energy or higher, vastly reducing detector response from background and lower energy radiations. The sniffer probes were tested using californium- 252 and americium-beryllium sources, followed by high-energy (up to 800 MeV) neutron exposures at the Los Alamos Neutron Science Center Weapons Neutron Research (WNR) facility. The sniffer probes were then used to identify areas around the accelerator facility where elevated levels of high-energy radiation was present and the plastic scintillators were placed in these locations to determine the high-energy neutron dose equivalent. The dose equivalent is calculated by measuring the 12 C(n,2n) 11 C reaction, which has a 20.4 MeV neutron threshold. Two locations behind the WNR facility were identified with the probes and the dose equivalent rates from neutron energies above 20 MeV were calculated to be 1.24 mrem/h behind flightpath 30-left and 1.53 behind flightpath 30-right. Of the four sniffer probes, the 2-inch x 2-inch cesium iodide is the recommended probe for performing high-energy shielding surveys. The larger crystal size yields higher sensitivity at lower count rates and the more dense material increases the likelihood of interaction within the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Basic Research Needs for High Energy Physics Detector Research & Development: Report of the Office of Science Workshop on Basic Research Needs for HEP Detector Research and Development: December 11-14, 2019

Transformative discovery in science is driven by innovation in technology. Our boldest undertakings in particle physics have at their foundation precision instrumentation. To reveal the profound connections underlying everything we see from the smallest scales to the largest distances in the Universe, to understand its fundamental constituents, and to reveal what is still unknown, we must invent, develop, and deploy advanced instrumentation. Investments in High Energy Physics (HEP) enabled by instrumentation have been richly rewarded with discoveries of the tiny masses of the neutrinos, the origin of mass itself: the enigmatic Higgs boson, and the surprising accelerating expansion of the Universe. What we have learned is remarkable, unexpected, exciting and mysterious; raising many new questions waiting to be answered. The quest to answer them drives innovation that improves the nation's health, wealth, and security, inspiring the public and drawing young people to science. Excellence and innovation come most effectively from diverse teams of people. Success, therefore, depends critically on attracting, engaging, and supporting a diverse cadre of young people to the field, and ensuring an inclusive environment at all levels. The program laid out in the 2014 Particle Physics Projects Prioritization Panel (P5) report "Building for Discovery - A Strategic Plan for U.S. Particle Physics in a Global Context" guides current and near future experiments to exploit these and other discoveries, and the instrumentation innovation they require, to push the frontiers of science into new territory. To explore this territory HEP will soon embark on planning the next generation of experiments. Realizing these experiments will require giant leaps in capabilities beyond the instrumentation of today. Accordingly, now is a pivotal moment to invest in the accelerated development of cost-effective instrumentation with greatly improved sensitivity and performance that will make measurable the unmeasurable, enabling a tool-driven revolution to open the door to future discoveries. Historic scientific opportunities await us, enabled by executing the instrumentation research plan outlined here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controlled experiments from the Space Shuttle

A study has been carried out to identify the controlled space physics and plasma physics experiments that can be performed from the Space Shuttle on sortie missions of 7 to 30-day duration. An experiment facility of this type appears to be well-matched to the sortie missions capability, and a technically feasible laboratory can provide a base for an extensive and significant research program to be carried out during the 1980-1990 time period. The laboratory, known as PPEPL, consists of a 33-ft pallet of instruments connected to a 25-ft pressurized control module. Two deployable 50-m booms, two subsatellites, a high power transmitter, a multipurpose high-power accelerator array, a set of deployable canisters for releases, and a gimbaled platform for pointing instruments are the primary systems mounted on the pallet.

Scarf, F. L.↗

Relativistic Electron Beams Accelerated By an Interplanetary Shock

Context: Collisionless shock waves have long been considered to be among the most prolific particle accelerators in the universe. Shocks alter the plasma they propagate through, and often exhibit complex evolution across multiple scales. Interplanetary (IP) traveling shocks have been recorded in situ for over half a century and act as a natural laboratory for experimentally verifying various aspects of large-scale collisionless shocks. A fundamentally interesting problem in both heliophysics and astrophysics is the acceleration of electrons to relativistic energies (> 300 keV) by traveling shocks. Aims: The reason for an incomplete understanding of electron acceleration at IP shocks is due to scale-related challenges and a lack of instrumental capabilities. This Letter presents the first observations of field-aligned beams of relativistic electrons upstream of an IP shock, observed thanks to the instrumental capabilities of Solar Orbiter. This study presents the characteristics of the electron beams close to the source and contributes to the understanding of their acceleration mechanism. Methods: On 25 July 2022, Solar Orbiter encountered an IP shock at 0.98 AU. The shock was associated with an energetic storm particle event, which also featured upstream field-aligned relativistic electron beams observed 14 min prior to the actual shock crossing. The distance of the beam’s origin was investigated using a velocity dispersion analysis (VDA). Peak-intensity energy spectra were analyzed and compared with those obtained from a semi-analytical fast-Fermi acceleration model. Results: By leveraging Solar Orbiter’s high temporal resolution Energetic Particle Detector (EPD), we successfully showcase an IP shock’s ability to accelerate relativistic electron beams. Our proposed acceleration mechanism offers an explanation for the observed electron beam and its characteristics, while we also explore the potential contributions of more complex mechanisms.

acceleration of particles↗

Performance of a fast digital integrator in on-field magnetic measurements for particle accelerators

The fast digital integrator has been conceived to face most demanding magnet test requirements with a resolution of 10 ppm, a signal-to-noise ratio of 105 dB at 20 kHz, a time resolution of 50 ns, an offset of 10 ppm, and on-line processing. In this paper, the on-field achievements of the fast digital integrator are assessed by a specific measurement campaign at the European Organization for Nuclear Research (CERN). At first, the architecture and the metrological specifications of the instrument are reported. Then, the recent on-field achievements of (i) {+-}10 ppm of uncertainty in the measurement of the main field for superconducting magnets characterization, (ii) {+-}0.02 % of field uncertainty in quality assessment of small-aperture permanent magnets, and (iii) {+-}0.15 % of drift, in an excitation current measurement of 600 s under cryogenic conditions, are presented and discussed.

43 PARTICLE ACCELERATORS↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

The McDonald Accelerating Stars Survey (MASS): White Dwarf Companions Accelerating the Sun-like Stars 12 Psc and HD 159062

We present the discovery of a white dwarf companion to the G1 V star 12 Psc found as part of a Keck adaptive optics imaging survey of long-term accelerating stars from the McDonald Observatory Planet Search Program. Twenty years of precise radial-velocity monitoring of 12 Psc with the Tull Spectrograph at the Harlan J. Smith telescope reveals a moderate radial acceleration (≈10 m s{sup −1} yr {sup −1}), which together with relative astrometry from Keck/NIRC2 and the astrometric acceleration between Hipparcos and Gaia DR2 yields a dynamical mass of M {sub B} = 0.605{sub −0.022}{sup +0.021} M {sub ⊙} for 12 Psc B, a semimajor axis of 40{sub −4}{sup +2} au, and an eccentricity of 0.84 ± 0.08. We also report an updated orbital fit of the white dwarf companion to the metal-poor (but barium-rich) G9 V dwarf HD 159062 based on new radial-velocity observations from the High-Resolution Spectrograph at the Hobby–Eberly Telescope and astrometry from Keck/NIRC2. A joint fit of the available relative astrometry, radial velocities, and tangential astrometric acceleration yields a dynamical mass of M {sub B} = 0.609{sub −0.011}{sup +0.010} M {sub ⊙} for HD 159062 B, a semimajor axis of 60{sub −7}{sup +5} au, and preference for circular orbits (e < 0.42 at 95% confidence). 12 Psc B and HD 159062 B join a small list of resolved Sirius-like benchmark white dwarfs with precise dynamical mass measurements which serve as valuable tests of white dwarf mass–radius cooling models and probes of AGB wind accretion onto their main-sequence companions.

47 OTHER INSTRUMENTATION↗

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

The development and evolution of biological AMS at Livermore: a perspective

Biological accelerator mass spectrometry (AMS) provides ultrasensitive carbon-14 isotopic analysis enabling a deeper understanding of human health concerns by enabling quantification of pharmacokinetics and other molecular endpoints directly in humans. It enables environmentally and human relevant studies of metabolic pathways through the use of very low concentrations of labeled metabolic substrates in cells and organisms. Here, we discuss why AMS is an important tool for the biosciences, the development and evolution of biological AMS at Livermore and discuss technical refinements that will improve the efficiency of operation for the measurement of ultra-trace levels of 14 C, which, long term, will enable greater ease of use and sample throughput.

47 OTHER INSTRUMENTATION↗

Advancement of LANSCE accelerator facility as a 1-MW Fusion Prototypic Neutron Source

The Fusion Prototypic Neutron Source (FPNS) is considered to be a testbed for scientific understanding of material degradation in future nuclear fusion reactors (Zinkle and Moeslang, 2013; Summary Report on the FPNS Workshop, 2018; Pitcher et al., 2019). The primary mission of FPNS is to provide a damage rate in iron samples of 8-11 dpa/calendar year with He/dpa ratio of 10 appm in irradiation volume of 50 cm 3 or larger with irradiation temperature 300–1000 °C and flux gradient less than 20%/cm in the plane of the sample. The Los Alamos Neutron Science Center (LANSCE) is an attractive candidate for the FPNS project. The Accelerator Facility was designed and operated for an extended period as a 0.8-MW Meson Factory. The existing setup of the LANSCE accelerator complex can nearly fulfill requirements of the fusion neutron source station. The primary function of the upgraded accelerator systems is the safe and reliable delivery of a 1.25-mA continuous proton beam current at 800-MeV beam energy from the switchyard to the target assembly to create 1 MW power of proton beam interacting with a solid tungsten target. The present study describes existing accelerator setup and further development required to meet the needs of FPNS project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of low-cost, high-performance non-evaporable getter (NEG) pumps

Low-cost, high-performance non-evaporable getter (NEG) pumps were constructed using commercial NEG pills comprising 70 wt% Zr, 24.6 wt% V, and 5.4 wt% Fe, a conflat flange with an outer diameter of 70, 152, or 203 mm (DN 40 CF, DN 100 CF, and DN 160 CF, respectively), and a tantalum heater. After activation at 400 °C for 30 min, the pumping speeds of a DN 40 CF NEG pump measured with the orifice method were 47–40, 8–6, 24–17, and 19–15 L/s for H{sub 2}, N{sub 2}, CO, and CO{sub 2} gasses, respectively. NEG pumps using DN 100 CF and DN 160 CF were also developed, and their pumping speeds are estimated. These NEG pumps are favorable alternatives to sputtering ion pumps in VSX beamlines because they do not produce hydrocarbons except during the activation period. The NEG pumps can also be used for accelerators, front ends, end stations, and differential pumping systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the C{sup 6+} laser ablation ion source for the KEK digital accelerator

A laser ion source that provides a fully ionized carbon ion beam is under joint development at the High Energy Accelerator Research Organization and Brookhaven National Laboratory. Long-pulse (6 ns) and short-pulse (500 ps) laser systems were tested by using them to irradiate a graphite target. Notable differences between the systems were observed in these experiments. Preliminary experimental results, such as the charge-state spectrum, beam intensity, and stability, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new solid state extractor pulser for the FNAL magnetron ion source

A new solid state extractor pulser has been installed on the Fermi National Accelerator Laboratory (FNAL) magnetron ion source, replacing a vacuum tube style pulser that was used for over 40 years. The required ion source extraction voltage is 35 kV for injection into the radio frequency quadrupole. At this voltage, the old pulser had a rise time of over 150 μs due to the current limit of the vacuum tube. The new solid state pulsers are capable of 50 kV, 100 A peak current pulses and have a rise time of 9 μs when installed in the operational system. This paper will discuss the pulser design and operational experience to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗