SU-G-TeP1-14: SRS Dose Calculation Accuracy Comparison Between Pencil Beam and Monte Carlo Algorithms

Purpose: Stereotactic radiosurgery (SRS) outcomes are related to the delivered dose to the target and to surrounding tissue. We have commissioned a Monte Carlo based dose calculation algorithm to recalculated the delivered dose planned using pencil beam calculation dose engine. Methods: Twenty consecutive previously treated patients have been selected for this study. All plans were generated using the iPlan treatment planning system (TPS) and calculated using the pencil beam algorithm. Each patient plan consisted of 1 to 3 targets and treated using dynamically conformal arcs or intensity modulated beams. Multi-target treatments were delivered using multiple isocenters, one for each target. These plans were recalculated for the purpose of this study using a single isocenter. The CT image sets along with the plan, doses and structures were DICOM exported to Monaco TPS and the dose was recalculated using the same voxel resolution and monitor units. Benchmark data was also generated prior to patient calculations to assess the accuracy of the two TPS against measurements using a micro ionization chamber in solid water. Results: Good agreement, within −0.4% for Monaco and +2.2% for iPlan were observed for measurements in water phantom. Doses in patient geometry revealed up to 9.6% differences for single target plans and 9.3% for multiple-target-multiple-isocenter plans. The average dose differences for multi-target-single-isocenter plans were approximately 1.4%. Similar differences were observed for the OARs and integral dose. Conclusion: Accuracy of the beam is crucial for the dose calculation especially in the case of small fields such as those used in SRS treatments. A superior dose calculation algorithm such as Monte Carlo, with properly commissioned beam models, which is unaffected by the lack of electronic equilibrium should be preferred for the calculation of small fields to improve accuracy.

60 APPLIED LIFE SCIENCES↗

Dynamic crack propagation and arrest in orthotropic DCB fiber composite specimens

An orthotropic double cantilever beam (DCB) model is used to study dynamic crack propagation and arrest in 90 deg unidirectional Hercules AS/3501-6 graphite fiber epoxy composites. The dynamic fracture toughness of the composite is determined from tests performed on the long-strip specimen and DCB crack arrest experiments are conducted. By using the dynamic fracture toughness in a finite-difference solution of the DCB governing partial differential equations, a numerical solution of the crack propagation and arrest events is computed. Excellent agreement between the experimental and numerical crack arrest results are obtained.

Williams, J. H., Jr.↗

Nonlinear flexure and torsion of rotating beams, with application to helicopter rotor blades. I - Formulation. II - Response and stability results

The dynamic response and aeroelastic stability of rotating beams such as helicopter blades is investigated analytically. The Hamilton principle is used to formulate the equations of motion for extensional and inextensional beams with precone angles and variable pitch angles, taking higher-order nonlinearities into account. The derivation of the equations and their approximate solution by a Galerkin procedure are explained in detail, and numerical results of equilibrium solutions and stability analyses are presented graphically.

Crespo Da Silva, M. R. M.↗

A continuum model for dynamic analysis of the Space Station

Dynamic analysis of the International Space Station using MSC/NASTRAN had 1312 rod elements, 62 beam elements, 489 nodes and 1473 dynamic degrees of freedom. A realtime, man-in-the-loop simulation of such a model is impractical. This paper discusses the mathematical model for realtime dynamic simulation of the Space Station. Several key questions in structures and structural dynamics are addressed. First, to achieve a significant reduction in the number of dynamic degrees of freedom, a continuum equivalent representation of the Space Station truss structure which accounted for the unsymmetry of the basic configuration and resulted in the coupling of extensional and transverse deformation, is developed. Next, dynamic equations for the continuum equivalent of the Space Station truss structure are formulated using a matrix version of Kane's dynamical equations. Flexibility is accounted for by using a theory that accommodates extension, bending in two principal planes and shear displacement. Finally, constraint equations suitable for dynamic analysis of flexible bodies with closed loop configuration are developed and solution of the resulting system of equations is based on the zero eigenvalue theorem.

Thomas, Segun↗

SU-F-T-527: A Novel Dynamic Multileaf Collimator Leaf-Sequencing Algorithm in Radiation Therapy

Purpose: A novel leaf-sequencing algorithm is developed for generating arbitrary beam intensity profiles in discrete levels using dynamic multileaf collimator (MLC). The efficiency of this dynamic MLC leaf-sequencing method was evaluated using external beam treatment plans delivered by intensity modulated radiation therapy technique. Methods: To qualify and validate this algorithm, integral test for the beam segment of MLC generated by the CORVUS treatment planning system was performed with clinical intensity map experiments. The treatment plans were optimized and the fluence maps for all photon beams were determined. This algorithm started with the algebraic expression for the area under the beam profile. The coefficients in the expression can be transformed into the specifications for the leaf-setting sequence. The leaf optimization procedure was then applied and analyzed for clinical relevant intensity profiles in cancer treatment. Results: The macrophysical effect of this method can be described by volumetric plan evaluation tools such as dose-volume histograms (DVHs). The DVH results are in good agreement compared to those from the CORVUS treatment planning system. Conclusion: We developed a dynamic MLC method to examine the stability of leaf speed including effects of acceleration and deceleration of leaf motion in order to make sure the stability of leaf speed did not affect the intensity profile generated. It was found that the mechanical requirements were better satisfied using this method. The Project is sponsored by the Scientific Research Foundation for the Returned Overseas Chinese Scholars, State Education Ministry.

60 APPLIED LIFE SCIENCES↗

Ion heating via turbulent ion acoustic waves.

The ion acoustic turbulence in the turbulent-heating experiment reported is excited by the ion-ion beam instability. Graphs are presented, showing the spatial evolution of the parallel ion beam energy and the spatial evolution of the ion acoustic turbulent wave spectrum. The observed characteristics of test waves in a turbulent beam-plasma imply that wave saturation is a dynamic balance between the emission of waves by the beam and the destruction or damping of wave coherence by the turbulent diffusion of particle orbits.

Taylor, R. J.↗

Computation and consequences of high order amplitude- and parameter-dependent tune shifts in storage rings for high precision measurements

Nonlinear effects of the various electric field and magnetic field components of storage rings to confine the particles and bend their trajectory can cause substantial amplitude-dependent tune shifts within the beam. Furthermore, tune shifts are often sensitive to variations of system parameters, e.g. total particle momentum offsets $δp$. Such amplitude- and parameter-dependent tune shifts influence the dynamics and stability of a beam in particle storage rings. Thus, it is critical for high precision measurements to analyze and understand these influences. On this basis, we present in this paper normal form methods for the calculation of high order amplitude and system parameter dependencies of the horizontal and vertical tunes in storage rings using the differential algebra (DA) framework within COSY INFINITY. A storage ring is simulated using COSY INFINITY to generate a DA Poincaré return map describing the transverse phase space behavior after each revolution in the storage ring. The map is expanded around the parameter-dependent closed orbit of the system before transforming the resulting map into normal form coordinates to extract the high order tune dependencies on the phase space amplitude and variation in the system parameters. As a specific example, a storage ring similar to the Storage Ring of the Muon g-2 Experiment at Fermilab (E989) is investigated.

43 PARTICLE ACCELERATORS↗

Derivation of a Tappered p-Version Beam Finite Element

A tapered p-version beam finite element suitable for dynamic applications is derived. The taper in the element is represented by allowing the area moments of inertia to vary as quartic polynomials along the length of the beam, and the cross-sectional area to vary as a quadratic polynomial. The p-version finite-element characteristics are implemented through a set of polynomial shape functions. The lower-order shape functions are identical to the classical cubic and linear shape functions normally associated with a beam element. The higher-order shape functions are a hierarchical set of polynomials that are integrals of orthogonal polynomials. Explicit expressions for the mass and stiffness matrices are presented for an arbitrary value of p. The element has been verified to be numerically stable using shape functions through 22nd order.

Hinnant, Howard E.↗

Critical Fluctuations in Beam-Plasma Systems and Solar Type III Radio Bursts

The type III radio bursts are the most intense radio emissions from the sun. In Figure 1, we present a typical type III burst observed by the STEREO spacecraft. Ginzburg and Zheleznyakov (1958) were the first to suggest that Langmuir waves excited by the solar flare accelerated electrons are the source of these bursts. The in situ detection of electron beams and Langmuir waves in association with type III bursts together with tracking of type III burst sources in the interplanetary medium confirmed this plasma hypothesis. However, the dynamics of type III electron beams and their interaction with the ambient plasma through the excited Langmuir waves is an unsolved problem. In order that the electron beams don't lose their energy by resonantly interacting with Langmuir waves, various nonlinear processes, such as the induced scattering of Langmuir waves off the background ions in weak turbulence regime and oscillating two-stream instability in strong turbulence regime were invoked. However, the observed electron density fluctuations do not allow Langmuir waves to grow to very high intensities as pointed out by several authors. As far as the conversion of Langmuir wave energy into electromagnetic energy is concerned, there is no consensus either for the fundamental or for the second harmonic emission. In this paper, we address these issues in terms of critical fluctuations near the boundary of the beam-plasma instability which is analogous to the anomalously growing fluctuations near the phase transition points called critical points. We show that this phenomenon can account for the survival of electron beams over large distances as well as the intensities of Langmuir waves excited during this phase transition regime are sufficient to explain the peak intensities of the fundamental as well as harmonic emissions

Fluctuations↗

A Chemical Dynamics Study of the Reaction of the Methylidyne Radical (CH, X 2 Π) with Dimethylacetylene (CH 3 CCCH 3 , X 1 A 1g )

The gas-phase reaction of the methylidyne (CH; X 2 Π) radical with dimethylacetylene (CH 3 CCCH 3 ; X 1 A 1g ) was studied at a collision energy of 20.6 kJ mol -1 under single collision conditions with experimental results merged with ab initio calculations of the potential energy surface (PES) and ab initio molecule dynamics (AIMD) simulations. Here, the crossed molecular beams experiment reveals that the reaction proceeds barrierless via indirect scattering dynamics through long-lived C 5 H 7 reaction intermediate(s) ultimately dissociating to C 5 H 6 isomers along with atomic hydrogen with atomic hydrogen predominantly released from the methyl groups as verified by replacing the methylidyne with the D1-methylidyne reactant. AIMD simulations reveal that the reaction dynamics are statistical leading predominantly to p28 (1-methyl-3-methylene-cyclopropene, 13 %) and p8 (1-penten-3-yne, 81 %) plus atomic hydrogen with a significant amount of available energy being channeled into the internal excitation of the polyatomic reaction products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

Electron Lenses for Experiments on Nonlinear Dynamics with Wide Stable Tune Spreads in the Fermilab Integrable Optics Test Accelerator

Recent developments in the study of integrable Hamiltonian systems have led to nonlinear accelerator lattice designs with two transverse invariants. These lattices may drastically improve the performance of high-power machines, providing wide tune spreads and Landau damping to protect the beam from instabilities, while preserving dynamic aperture. To test the feasibility of these concepts, the Integrable Optics Test Accelerator (IOTA) is being designed and built at Fermilab. One way to obtain a nonlinear integrable lattice is by using the fields generated by a magnetically confined electron beam (electron lens) overlapping with the circulating beam. The parameters of the required device are similar to the ones of existing electron lenses. We present theory, numerical simulations, and first design studies of electron lenses for nonlinear integrable optics.

43 PARTICLE ACCELERATORS↗

Coherent X-ray radiation excited by a diverging relativistic electron beam in a single crystal

We develop a dynamic theory of coherent X-rays generated in a single-crystal wafer by a diverging relativistic electron beam. The dependence of the spectral-angular density of coherent X-ray radiation on the angle of divergence is analyzed for the case when the angular spread can be described by the 2D Gaussian distribution. The theory constructed here makes it possible to analyze coherent radiation for an arbitrary angular distribution of electrons in the beam as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A polarization-switch effect of silicon crystals under multiple-beam diffraction geometry

On the basis of rigorous dynamical-theory calculations, a complete X-ray polarization-switch effect of silicon crystals at the exact multiple-beam diffraction condition is demonstrated in this paper. The underlying physical mechanism of this unique phenomenon can be revealed using a simple multiple-wave propagation and interference model. The constructive and destructive interference of the multiple detoured-diffraction beams along the direction of the primary diffracted beam directly leads to the complete polarization switch. This phenomenon can be realized using both synchrotron and laboratory X-ray sources at many discrete wavelengths, and used to design a novel crystal-based polarizer to achieve a 90° polarization rotation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vibration of a large space beam under gravity effect

The structural characteristics of a large simply supported beam subjected to gravity are described. The nonlinear governing equations for both the static and the dynamic response are derived and solved analytically. The results show the feasibility of verifying the on-orbit dynamic characteristics of a large space beam by utilizing ground test data of such a structure. It is noted that the gravity effect interacts mostly with the first vibration mode. It was also found that the system of a large space beam subjected to its own weight is a hardening system. The differential equation for the asymmetric mode is a Duffing type equation. However, the governing equation for the symmetric mode has an additional quadratic term. It is this term that causes the maximum vibration amplitudes at different phases to be non-identical.

Shih, C.-F.↗

Plasmon-Mediated Entanglement Dynamics

We explore the steady state entanglement of quantum emitters coupled to a lossy plasmonic reservoir and driven by laser or electron-beam pump fields with picosecond antibunching dynamics.

Lawrie, Benjamin J.↗

WE-EF-303-08: Proton Radiography Using Pencil Beam Scanning and Novel Micromegas Detectors

Purpose: While the energy of therapeutic proton beams can be adjusted to penetrate to any given depth in water, range uncertainties arise in patients due in part to imprecise knowledge of the stopping power of protons in human tissues. Proton radiography is one approach to reduce the beam range uncertainty, thereby allowing for a reduction in treatment margins and dose escalation. Methods: The authors have adapted a novel detector technology based on Micromesh Gaseous Structure (“Micromegas”) for proton therapy beams and have demonstrated fine spatial and time resolution of magnetically scanned proton pencil beams, as well as wide dynamic range for dosimetry. In this work, proton radiographs were obtained using Micromegas 2D planes positioned downstream of solid water assemblies. The position-sensitive monitor chambers in the IBA proton delivery nozzle provide the beam entrance position. Results: Radiography with Micromegas detectors and actively scanned beams provide spatial resolution of up to 300 µm and water-equivalent thickness (WET) resolution as good as 0.02% (60 µm out of 31 cm total thickness), with the dose delivered to the patient kept below 2 cGy. The spatial resolution as a function of sample rate and number of delivered protons is found to be near the theoretical Cramer-Rao lower bound. Using the CR bound, we argue that the imaging dose could be further lowered to 1 mGy, while still achieving sub-mm spatial resolution, by relatively simple instrumentation upgrades and beam delivery modifications. Conclusion: For proton radiography, high spatial and WET resolution can be achieved, with minimal additional dose to patient, by using magnetically scanned proton pencil beams and Micromegas detectors.

60 APPLIED LIFE SCIENCES↗