Search NASA⌕ Search

SEARCH · Search NASA

Results for “Behavior change”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Delayed HIV diagnosis common in Sweden, 2003–2010

Background: Early diagnosis of HIV is important for the prognosis of individual patients, because antiretroviral treatment can be started at the appropriate time, and for public health, because transmission can be prevented. Methods: Data were collected from 767 HIV patients who were diagnosed in Sweden during 2003–2010 and were infected in Sweden or born in Sweden and infected abroad. A recent infection testing algorithm (RITA) was applied to BED-EIA test results (OD-n < 0.8), CD4 counts (≥ 200 cells/μl), and clinical information. A recent infection classification was used as indicator for early diagnosis. Time trends in early diagnosis were investigated to detect population changes in HIV testing behavior. Patients with early diagnosis were compared to patients with delayed diagnosis with respect to age, gender, transmission route, and country of infection (Sweden or abroad). Results: Early diagnosis was observed in 271 patients (35%). There was no statistically significant time trend in the yearly percentage of patients with early diagnosis in the entire study group (p = 0.836) or in subgroups. Early diagnosis was significantly more common in men who have sex men (MSM) (45%) than in heterosexuals (21%) and injecting drug users (27%) (p < 0.001 and p = 0.001, respectively) in both univariate and multivariable analyses. The only other factor that remained associated with early diagnosis in multivariable analysis was young age group. Conclusion: Approximately one-third of the study patients were diagnosed early with no significant change over time. Delayed HIV diagnosis is a considerable problem in Sweden, which does not appear to diminish.

delayed diagnosis↗

Thermo-Oxidation Analysis of Structural Adhesives: An Experimental Study

Abstract Cross-linked polymers play an important role in structural applications as adhesives. In this article, we performed an experimental study to understand the effects of high temperature i.e. thermo-oxidative aging on the mechanical behavior of polymers. Subsequently, the constitutive behavior, i.e. stress-strain relation of these adhesives before and after the accelerated aging tests were studied on samples aged at different temperature and different time durations at zero humidity. The aging conditions and periods selected for the tests have been specifically designed to simulate the effects of aging under the working conditions that the materials will be subjected to in their standard applications. The focus of this study is on the investigation of the effects of aging on the polymeric adhesives used in automotive applications. Consequently, four different polymeric adhesives (one silicone-based, two polyurethane-based, and one acrylic type), which are being used extensively in these applications, have been chosen. The quasi-static tensile loading was used on these four adhesives and the changes in the constitutive behavior were measured. The failure tensile tests as well as the cyclic tensile tests were performed in our lab using a Test-Resources tensile testing machine. The temperatures that were used in this work are 60, 80 and 95°C for varying aging periods of 24hrs, 240hrs, and 720hrs. Then, all the data was collected and consequently analyzed, and the resulting behavior was compared to that of the unaged material, showing varying results depending on the material, temperature, and aging period. Different behaviors have been observed after aging. The polymers’ behavior was expanding from no effect to significant damage caused by aging conditions. This work provides the core understanding required for modeling the material behavior during aging and lays down the groundwork for further data-infused model-free approaches.

Alazhary, Sharif↗

Epigenetic effects of paternal cocaine on reward stimulus behavior and accumbens gene expression in mice

Paternal cocaine use causes phenotypic alterations in offspring behavior and associated neural processing. In rodents, changes in first generation (F1) offspring include drug reward behavior, circadian timing, and anxiety responses. This study, utilizing a murine (C57BL/6J) oral cocaine model, examines the effects of paternal cocaine exposure on fundamental characteristics of offspring reward responses, including: 1) the extent of cocaine-induced effects after different durations of sire drug withdrawal; 2) sex- and drug-dependent differences in F1 reward preference; 3) effects on second generation (F2) cocaine preference; and 4) corresponding changes in reward area (nucleus accumbens) mRNA expression. We demonstrate that paternal cocaine intake over a single ˜40-day spermatogenic cycle significantly decreased cocaine (but not ethanol or sucrose) preference in a sex-specific manner in F1 mice from sires mated 24h after drug withdrawal. However, F1 offspring of sires bred 4 months after withdrawal did not exhibit altered cocaine preference. Altered cocaine preference also was not observed in F2's. RNASeq analyses of F1 accumbens tissue revealed changes in gene expression in male offspring of cocaine-exposed sires, including many genes not previously linked to cocaine addiction. Enrichment analyses highlight genes linked to CNS development, synaptic signaling, extracellular matrix, and immune function. Expression correlation analyses identified a novel target, Fam19a4, that may negatively regulate many genes in the accumbens, including genes already identified in addiction. Collectively, these results reveal that paternal cocaine effects in F1 offspring may involve temporally limited epigenetic germline effects and identify new genetic targets for addiction research.

59 BASIC BIOLOGICAL SCIENCES↗

Automated Bacterial Identification and Morphological Feature Analysis in Low‐Dose Cryo‐EM Using YOLOv11

Bacteria rapidly adapt to environmental cues through morphological and ultrastructural changes that correlate with physiology and behavior. Cryogenic transmission electron microscopy (cryo‐TEM) can capture these phenotypic changes in near‐native, vitrified states, but manual analysis of low‐dose micrographs is labor intensive and limits throughput. Here, we present an end‐to‐end workflow that combines low‐dose cryo‐TEM imaging with a YOLOv11‐based instance‐segmentation model to automatically identify bacteria and quantify key structural features directly from the micrographs. This workflow enables (i) robust bacterial localization and counting from low‐magnification atlas/montage images, (ii) automated measurements of cell‐envelope (outer–inner membrane) thickness and anisotropy from higher‐magnification views, and (iii) detection and quantification of bacteria–flagella interactions, including overlap length and curvature metrics for interacting versus noninteracting flagella. Using Pantoea sp. YR343 grown under distinct media conditions, we show that the automated measurements agree with manual annotations while substantially reducing analysis time. Together, these tools provide a practical framework for scalable bacterial identification and quantitative phenotyping in low‐dose cryo‐TEM datasets and establish a foundation for extending cryo‐TEM image analysis toward higher‐throughput studies of microbial heterogeneity and biointerfaces.

YOLOv11↗

Pitting behavior of friction stir repair-welded 304L stainless steel in 3.5% NaCl solution at room temperature: role of grain and defect structures

Stainless steel (SS) canisters used for storing spent nuclear waste are prone to chloride-induced stress corrosion cracking. Friction stir welding (FSW), being a low heat input process, can be used for repair welding of these canisters. In this study, an artificial crack was introduced on the 304L SS coupons by an electric discharge machining process. The artificial crack was repair-welded by FSW by maintaining the tool temperature a constant at two levels (725 and 825 °C). Friction stirring significantly reduced the grain size of the stirred zone (SZ) from about 47 to 2–4 μm. The fraction of low-angle grain boundaries increased in the SZ from 2 to 37–43%. Here, on the other hand, the fraction of special grain boundaries (Σ3 and Σ9) that was ~ 50% in the base metal reduced to < 10% in the SZ. During friction stirring, the oxide layer of artificial crack was broken and aligned to form a spiral defect called lazy-S structure. All these microstructural changes affected the corrosion behavior of the FSW specimens when tested in 3.5% NaCl at room temperature using cyclic polarization, chronoamperometry, and electrochemical impedance spectroscopy. The FSW specimens showed lower polarization resistance and lower transpassive potential than those of the base metal specimens. However, the pitting protection potentials of the FSW specimens were higher than that of the base metal. The pitting behavior of the FSW specimens was influenced more by the preferential attack on the lazy-S region than by passive film breakdown. The flat band potentials of the passive film formed on the FSW specimens were more positive than that of base metal. The charge carrier density of passive film formed on the FSW specimens was higher than that of the base metal. The higher fraction of low-angle grain boundaries present in the FSW specimens could supply more number of misorientation dislocations at the metal/film interface which could form anion vacancies by a climb process leading to formation of oxide at these locations without stressing the substrate. Therefore, low-angle boundaries are considered helpful for formation of stress-free passive films that will be highly stable and enhance both pitting and stress corrosion cracking resistance.

Dry storage canister↗

Test Methodology Development for Experimental Structural Assessment of ASC Planar Spring Material for Long-Term Durability

A vibration-based testing methodology has been developed that will assess fatigue behavior of the metallic material of construction for the Advanced Stirling Convertor displacer (planar) spring component. To minimize the testing duration, the test setup is designed for base-excitation of a multiplespecimen arrangement, driven in a high-frequency resonant mode; this allows completion of fatigue testing in an accelerated period. A high performance electro-dynamic exciter (shaker) is used to generate harmonic oscillation of cantilever beam specimens, which are clasped on the shaker armature with specially-designed clamp fixtures. The shaker operates in closed-loop control with dynamic specimen response feedback provided by a scanning laser vibrometer. A test coordinator function synchronizes the shaker controller and the laser vibrometer to complete the closed-loop scheme. The test coordinator also monitors structural health of the test specimens throughout the test period, recognizing any change in specimen dynamic behavior. As this may be due to fatigue crack initiation, the test coordinator terminates test progression and then acquires test data in an orderly manner. Design of the specimen and fixture geometry was completed by finite element analysis such that peak stress does not occur at the clamping fixture attachment points. Experimental stress evaluation was conducted to verify the specimen stress predictions. A successful application of the experimental methodology was demonstrated by validation tests with carbon steel specimens subjected to fully-reversed bending stress; high-cycle fatigue failures were induced in such specimens using higher-than-prototypical stresses

fatigue testing machines↗

Electrochemistry and Spectroelectrochemistry of Luminescent Europium Complexes

Abstract Fast, cost effective, and robust means of detecting and quantifying lanthanides are needed to support more efficient tracking within the nuclear, medicinal, and industrial fields. Furthermore, methods for isolating lanthanide signal from spectroscopic interferents are also needed. Applying spectroelectrochemistry to the detection of these species can meet those needs. However, application of this technique is limited by the low molar absorptivities and quantum yields of the lanthanides. These limitations can be circumvented by complexing the lanthanides with sensitizing ligands that enhance fluorescence, thereby dropping the limits of detection. Complexation will also cause changes in the electrochemical behavior of the lanthanides. To demonstrate this concept, studies were completed using europium as a model lanthanide in complexes with four different sensitizing ligands, which included 2,2′‐bipyridine and related derivatives. Results indicate that all four studied complexes demonstrate quasi‐reversible redox couples and improvements in limits of detection where electrochemical and spectroscopic characteristics showed some dependence on attached ligand. All four complexes studied display the necessary characteristics for spectroelectrochemical analysis, which was successfully and reproducibly applied to all Eu complexes.

Lines, Amanda M.↗

Estimation of Time-Varying Pilot Model Parameters

Human control behavior is rarely completely stationary over time due to fatigue or loss of attention. In addition, there are many control tasks for which human operators need to adapt their control strategy to vehicle dynamics that vary in time. In previous studies on the identification of time-varying pilot control behavior wavelets were used to estimate the time-varying frequency response functions. However, the estimation of time-varying pilot model parameters was not considered. Estimating these parameters can be a valuable tool for the quantification of different aspects of human time-varying manual control. This paper presents two methods for the estimation of time-varying pilot model parameters, a two-step method using wavelets and a windowed maximum likelihood estimation method. The methods are evaluated using simulations of a closed-loop control task with time-varying pilot equalization and vehicle dynamics. Simulations are performed with and without remnant. Both methods give accurate results when no pilot remnant is present. The wavelet transform is very sensitive to measurement noise, resulting in inaccurate parameter estimates when considerable pilot remnant is present. Maximum likelihood estimation is less sensitive to pilot remnant, but cannot detect fast changes in pilot control behavior.

Zaal, Peter M. T.↗

Physics-aware adaptive checkpointing with shadow systems for nonlinear PDE simulations

Large-scale simulations of nonlinear partial differential equations (PDEs) that exhibit strongly transient behavior and pattern-forming dynamics produce enormous amounts of data, which, even with modern storage systems, cannot be stored for later curation. Current I/O strategies either write dense time series of snapshots, which is often prohibitive in I/O and storage, or store a few checkpoints that enable restart but incur expensive recomputation cost and provide no control over post-restart error growth, especially when lossy compression is used. Moreover, most, if not all, existing strategies take no account of the actual physical state of the system. Here, we present a simple physics-aware I/O framework in which a low-cost shadow system adaptively triggers lossy checkpoints when the shadow system deviates from the fine-scale simulation. The shadow system can be a coarsened replica of the fine-scale simulation that evolves concurrently. This means that checkpoints are taken based on the physical state of the system: fewer checkpoints are triggered when the system is quiescent while more are taken when the system undergoes a rapid change. This type of behavior is observed in many systems such as Brusselator and FitzHugh–Nagumo. We illustrate that our framework maintains stable restarts, keeps fine-scale restart errors bounded by shadow errors, and reconstructs the time history with significantly lower error and storage than interpolating fixed-interval snapshots, with low-cost shadow replay and modest online synchronization overhead.

Gong, Qian [ORNL] (ORCID:0000000235704142)↗

Treatment approach, delivery, and follow-up evaluation for cardiac rhythm disease management patients receiving radiation therapy: Retrospective physician surveys including chart reviews at numerous centers

In a 2-part study, we first examined the results of 71 surveyed physicians who provided responses on how they address the management of patients who maintained either a pacemaker or a defibrillator during radiation treatment. Second, a case review study is presented involving 112 medical records reviewed at 18 institutions to determine whether there was a change in the radiation prescription for the treatment of the target cancer, the method of radiation delivery, or the method of radiation image acquisition. Statistics are provided to illustrate the level of administrative policy; the level of communication between radiation oncologists and heart specialists; American Joint Committee on Cancer (AJCC) staging and classification; National Comprehensive Cancer Network (NCCN) guidelines; tumor site; patient's sex; patient's age; device type; manufacturer; live monitoring; and the reported decisions for planning, delivery, and imaging. This survey revealed that 37% of patient treatments were considered for some sort of change in this regard, whereas 59% of patients were treated without regard to these alternatives when available. Only 3% of all patients were identified with an observable change in the functionality of the device or patient status in comparison with 96% of patients with normal behavior and operating devices. Documented changes in the patient's medical record included 1 device exhibiting failure at 0.3-Gy dose, 1 device exhibiting increased sensor rate during dose delivery, 1 patient having an irregular heartbeat leading to device reprogramming, and 1 patient complained of twinging in the chest wall that resulted in a respiratory arrest. Although policies and procedures should directly involve the qualified medical physicist for technical supervision, their sufficient involvement was typically not requested by most respondents. No treatment options were denied to any patient based on AJCC staging, classification, or NCCN practice standards.

61 RADIATION PROTECTION AND DOSIMETRY↗

Leaching characteristics of toxic constituents from coal fly ash mixed soils under the influence of pH

Highlights: • The impact of pH on the leaching of elements and metals from fly ash mixed soils. • Generally Ca, Cd, Mg, and Sr follows a cationic leaching pattern. • The leaching of As and Se shows an oxyanionic leaching pattern. • The leaching behavior of elements does not change based on material type. • Different fly ash types show different abilities in immobilizing trace elements. - Abstract: Leaching behaviors of Arsenic (As), Barium (Ba), Calcium (Ca), Cadmium (Cd), Magnesium (Mg), Selenium (Se), and Strontium (Sr) from soil alone, coal fly ash alone, and soil-coal fly ash mixtures, were studied at a pH range of 2–14 via pH-dependent leaching tests. Seven different types of soils and coal fly ashes were tested. Results of this study indicated that Ca, Cd, Mg, and Sr showed cationic leaching pattern while As and Se generally follows an oxyanionic leaching pattern. On the other hand, leaching of Ba presented amphoteric-like leaching pattern but less pH-dependent. In spite of different types and composition of soil and coal fly ash investigated, the study reveals the similarity in leaching behavior as a function of pH for a given element from soil, coal fly ash, and soil-coal fly ash mixtures. The similarity is most likely due to similar controlling mechanisms (e.g., solubility, sorption, and solid-solution formation) and similar controlling factors (e.g., leachate pH and redox conditions). This offers the opportunity to transfer knowledge of coal fly ash that has been extensively characterized and studied to soil stabilized with coal fly ash. It is speculated that unburned carbon in off-specification coal fly ashes may provide sorption sites for Cd resulting in a reduction in concentration of these elements in leachate from soil-coal fly ash mixture. Class C fly ash provides sufficient CaO to initiate the pozzolanic reaction yielding hydrated cement products that oxyanions, including As and Se, can be incorporated into.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The impacts of training on change deafness and build-up in a flicker task

Performance on auditory change detection tasks can be improved by training. We examined the stimulus specificity of these training effects in behavior and ERPs. A flicker change detection task was employed in which spatialized auditory scenes were alternated until a "change" or "same" response was made. For half of the trials, scenes were identical. The other half contained changes in the spatial locations of objects from scene to scene. On Day 1, participants were either trained on this auditory change detection task (trained group), or trained on a non-auditory change detection task (control group). On Day 2, all participants were tested on the flicker task while EEG was recorded. The trained group showed greater change detection accuracy than the control group. They were less biased to respond "same" and showed full generalization of learning from trained to novel auditory objects. ERPs for "change" compared to "same" trials showed more negative going P1, N1, and P2 amplitudes, as well as a larger P3b amplitude. The P3b amplitude also differed between the trained and control group, with larger amplitudes for the trained group. Analysis of ERPs to scenes viewed prior to a decision revealed build-up of a difference between "change" and "same" trials in N1 and P2. Results demonstrate that training has an impact early in the "same" versus "change" decision-making process, and that the flicker paradigm combined with the ERP method can be used to study the build-up of change detection in auditory scenes.

60 APPLIED LIFE SCIENCES↗

Irradiation Behavior of Piezoelectric Materials for Nuclear Reactor Sensors

In-situ measurement of surface acoustic wave (SAW) resonators were used to characterize piezoelectric materials behavior in a nuclear reactor environment. Lithium niobate and aluminum nitride devices were tested up to 500°C temperature and 450 kW reactor power (1.9x10 12 n/cm 2 s). The resonant frequency responds to step changes in temperature and power. Materials’ response are inferred from the observed resonant frequency changes, in particular the kinetic behavior is used to determine mechanisms responsible for observed changes. The observed response is attributed to two mechanisms: temperature increase from gamma heating and accumulation of radiation-induced defects. Both of these mechanisms alter the physical properties of the piezoelectric materials, particularly the elastic constants. The demonstrated repeatability and reliability of SAW devices are attractive for sensor applications in extreme environments.

36 MATERIALS SCIENCE↗

Therapy against organophosphate poisoning: The importance of anticholinergic drugs with antiglutamatergic properties

Potent cholinesterase inhibitors (e.g., soman, sarin), induce a wide range of deleterious effects including convulsions, behavioral impairments and ultimately, death. Due to the likelihood of various scenarios of military or terrorist attacks by these and other chemical weapons, research has to be aimed at finding optimal therapies. Early accumulation of acetylcholine in synaptic clefts was suggested to trigger an array of toxic events including an excessive release of glutamate, culminating in the activation of its receptors. Stimulation of the N-Methyl-D-Aspartate (NMDA) subtype of these receptors was associated with the neuronal injury that initiates organophosphate-induced brain damage. The notion of a stepwise mechanism yielded treatments based on a combination of an immediate administration of enzyme reactivators and anticholinergic drugs. This strategy dramatically increased survival rates but did not abolish convulsions and failed to prevent the ensuing cognitive dysfunction. Efforts to improve this paradigm by adding anticonvulsants or antiglutamatergic drugs with anti-epileptic characteristics produced dubious results. Under these conditions, benactyzine and caramiphen, agents with anticholinergic and antiglutamatergic properties, provided improved protection when introduced as adjunct agents to oximes, reversible cholinesterase inhibitors and/or specific antimuscarinic drugs such as atropine. In contrast, the specific antimuscarinic drug scopolamine failed to block soman-induced changes in glutamatergic and behavioral parameters even when given prophylactically. These findings along with a large number of additional reports led towards the conclusion that the therapeutic advantage of drugs such as benactyzine and caramiphen could derive from their ability to modulate central cholinergic and glutamate neurotransmission.

60 APPLIED LIFE SCIENCES↗

Characterization of a Filtered High Current Pulsed Cathodic Vacuum Arc Plasma Source: Plasma Transport Analysis

Studies of plasma behavior produced by a filtered high current pulsed cathodic vacuum arc system are reported. Titanium plasma is initiated from the cathode by surface flash over triggering at the centre of the cathode disk. The multiple arc spots move outwards due to their mutual repulsion and the arc current pulse is terminated as the arc spots reach the edge of the cathode disk. The plasma moves into a positively biased quarter-torus magnetic filter and is guided towards the substrate position located 150 mm beyond the filter exit. Electron density and plasma current measurements have been employed to analyze the transport of the plasma associated with different cathode currents, and its dependence on confining magnetic field and bias conditions. For a given cathode current, the optimum plasma transport to the substrate requires the right combination of the strength of the confining magnetic field and the magnetic filter positive bias. The optimum values of these two parameters were found to increase with increasing cathode current. Initially the optimum throughput of plasma increases more strongly than the arc current (roughly 1.5 times the increase in the current); however, at high cathode current regimes (2.4 kA) a significant change of the plasma behavior is seen and transport efficiency is reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The impact of non-ideal phase change properties on phase change thermal energy storage device performance

Phase change materials have been known to improve the performance of energy storage devices by shifting or reducing thermal/electrical loads. While an ideal phase change material is one that undergoes a sharp, reversible phase transition, real phase change materials do not exhibit this behavior and often have one or more non-idealities – glide, hysteresis, supercooling – associated with them. Experimental and modeling techniques to characterize these non-ideal properties are reasonably well understood, however, their impact on the performance of a thermal energy storage system is not fully understood. Herein, we analyze the performance of a heat exchanger with a phase change material as a function of the different non-idealities, for a heating and a cooling application. We focus on the impact of these non-ideal behaviors on different modes of operation of the thermal energy storage device, which will serve as a useful guide to researchers on the relative importance of the non-ideal properties, along with the necessary accuracy required during an experimental characterization.

25 ENERGY STORAGE↗

Interfacial reactions of Cu( II ) adsorption and hydrolysis driven by nano-scale confinement

Spatial confinement is prevalent in sedimentary rocks and can lead to changes in the chemical behavior at mineral–water interfaces. This includes both deviations in the physico-chemical properties of confined water, when compared to the bulk liquid phase, and subsequent alterations in adsorption chemistry of ions inside nano-scale mineral pores. In this paper we document contrasting adsorption mechanisms and differences in local coordination environments of copper (Cu 2+ ), depending on whether the ion is adsorbed on non-porous silica surfaces, versus inside 8 nm and 4 nm pores in silica. X-ray absorption spectroscopy, flow micro-calorimetry, and batch adsorption methods together with molecular modeling are used to thoroughly describe the dependence of these adsorption processes on the pore size. We show that confinement within silica pores promotes Cu–Cu interactions and increases the formation of Cu–Cu polynuclear surface complexes. We also demonstrate that the mechanism of Cu 2+ adsorption on non-porous versus porous silica is vastly different. The adsorption of Cu 2+ on non-porous silica is an endothermic process, whereby Cu 2+ undergoes dehydration prior to surface complexation. In contrast, adsorption within nano-scale pores is preceded by only partial dehydration, and significant formation of Cu–Cu polynuclear complexes, which leads to an overall exothermic signal. Interfacial confinement leads to dramatic changes in the adsorption mechanism and speciation, which in turn controls the fate and transport of chemical species in natural environments.

58 GEOSCIENCES↗

Effects of Central Cut Width on the Dynamical Characteristics of Box Assembly Structure

An investigation into the Box Assembly with Removable Component (BARC) structure is conducted by utilizing computational simulations and experimental structural testing in order to determine the complex dynamical responses instigated by the central cut of the system. Because the dynamics of the BARC system is complex, this study focuses primarily on analyzing the behavior of the box assembly (BA) system. The investigation explores the dynamics of the BA system by varying the central cut widths, ranging from a cut as wide as 0.5” cut to a 0.25” cut system, as well as a 0.1” cut and a system with no cut at all. Experimental testing is performed on each system including a free vibration test using an impact hammer to excite and identify the dominant frequencies of each structure. This testing is followed by pseudo-random vibration tests and swept sinusoidal excitation tests to determine the nonlinear aspects of these systems, such as the possible existence of nonlinear softening, hardening, and/or damping. The results show that nonlinear softening and nonlinear damping are present in each system. The no-cut system demonstrated the highest peak frequencies throughout all the tests, being the most rigid structure. The 0.25” cut system was shown to have the highest peak frequencies among all the cut systems in both the finite elemenet analysis (FEA) and impact testing. This trend did not continue, though, in the random and harmonic testing, possibly due to the added stiffness of the test setup with the slip table and stinger. The results show the importance of accurately measuring the central cut width and how possible geometric uncertainties change the overall dynamical behaviors of complex systems, such as natural characteristics, nonlinear responses, coupling of modes, and oscillating amplitudes.

Padilla, Christopher (ORCID:000900033446732X)↗