Utilizing Boost and Double Injections for Enhanced Stratified-Charge DISI Operation with Gasoline and E30 Fuels.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
This study aims to develop a search for Dark Matter (DM) in a signature of missing transverse energy and jets in the CMS detector at the Large Hadron Collider at CERN. We study the generation of a simplified model for the pair production of spin-1 Z’ bosons, with one of them decaying into a pair of DM particles. The signal events are generated via MadGraph, in the LHE (Les Houches Event) file format, and their kinematics are studied.
Abstract not provided.
Commuting models estimate the number of commuting trips from home to work locations in a given area. Since their infancy, they have been increasingly used in a variety of fields to reduce traffic and pollution, drive infrastructure choices, and solve a variety of other problems. Traditional commuting models, such as gravity and radiation models, typically have a strict structural form and limited number of input variables, which may limit their ability to predict commuting flows as well as machine learning models that might better capture the complex dynamics of the commuting process. To determine whether machine learning models might add value to the field of commuter flow prediction, we compare and discuss the performance of two standard traditional models with the XGBoost machine learning algorithm for predicting home to work commuter flows from a well-known United States commuting dataset. We find that the XGBoost model outperforms the traditional models on three commonly used metrics, indicating that machine learning models may add value to the field of commuter flow prediction.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Most utility new construction programs depend on modeled projections and deemed savings based on individual technologies. The industry has established ways to evaluate these programs based on the promise - not the actual performance - of these buildings post- occupancy. Deeper savings from a more integrated design with continuous performance monitoring are left on the table, locking out the higher performance for the lifetime of the building. This paper will demonstrate how performance-based procurement can empower utility incentive offerings to drive deep energy savings and reduce administrative costs. The key is to incentivize a change in the building owner's procurement process and reward actual building energy performance rather than incentivizing specific measures. The paper looks at strategies to transition new construction programs from technology-based verification to actual measurement of performance outcomes. Accelerate Performance, a U.S. Department of Energy (DOE) funded initiative, changes the building procurement approach, which spurs innovation and motivates the design and contracting industry to achieve deep energy savings in new construction - in the case of DOE's National Renewable Energy Laboratory Research Support Facility (NREL) in Golden, CO, 50% without increasing initial costs. Utility programs in three states, Illinois, Minnesota, and Connecticut, are actively piloting the approach with leading-edge owners. The paper will share savings results and lessons learned from the three different utility pilot programs. The paper provides practical guidance for utility program managers about how to apply the Accelerate Performance approach to supplement their current new construction program offerings.
The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.
The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.
Explore the source record for details and available documents.
For six decades, the U.S. Army has safely and securely stored chemical munitions at the Pueblo Chemical Depot in Colorado. To help fulfill international treaty obligations and to meet a congressional deadline of 2023 for the elimination of these aging weapons, initial destruction of the Pueblo chemical weapons stockpile began in 2015. A utility energy service contract (UESC) executed in 2016 between the U.S. Army Corps of Engineers and the Depot’s serving utility, Black Hills Energy (BHE), directly supported this mission with the installation of a new electrical substation that was essential to the Depot’s need for uninterrupted power.
Explore the source record for details and available documents.
The Federal Energy Management Program (FEMP) encourages federal agencies and organizations to improve data center energy efficiency, which can offer tremendous opportunities for energy and cost savings. In this success story, a novel liquid cooling system provides reliable, resilient, and energy-efficient cooling for high performance computing (HPC) systems at Sandia National Laboratories.
The Federal Energy Management Program (FEMP) encourages federal agencies and organizations to improve data center energy efficiency, which can offer tremendous opportunities for energy and cost savings. In this success story, a novel liquid cooling system provides reliable, resilient, and energy-efficient cooling for high-performance computing (HPC) systems at Sandia National Laboratories.