Search NASA⌕ Search

SEARCH · Search NASA

Results for “CEBAF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A versatile scalable PET processing system

Positron Emission Tomography (PET) historically has major clinical and preclinical applications in cancerous oncology, neurology, and cardiovascular diseases. Recently, in a new direction, an application specific PET system is being developed at Thomas Jefferson National Accelerator Facility (Jefferson Lab) in collaboration with Duke University, University of Maryland at Baltimore (UMAB), and West Virginia University (WVU) targeted for plant eco-physiology research. The new plant imaging PET system is versatile and scalable such that it could adapt to several plant imaging needs - imaging many important plant organs including leaves, roots, and stems. The mechanical arrangement of the detectors is designed to accommodate the unpredictable and random distribution in space of the plant organs without requiring the plant be disturbed. Prototyping such a system requires a new data acquisition system (DAQ) and data processing system which are adaptable to the requirements of these unique and versatile detectors.

43 PARTICLE ACCELERATORS↗

Implementation of a level 1 trigger system using high speed serial (VXS) techniques for the 12GeV high luminosity experimental programs at Thomas Jefferson National Accelerator Facility

We will demonstrate a hardware and firmware solution for a complete fully pipelined multi-crate trigger system that takes advantage of the elegant high speed VXS serial extensions for VME. This trigger system includes three sections starting with the front end crate trigger processor (CTP), a global Sub-System Processor (SSP) and a Trigger Supervisor that manages the timing, synchronization and front end event readout. Within a front end crate, trigger information is gathered from each 16 Channel, 12 bit Flash ADC module at 4 nS intervals via the VXS backplane, to a Crate Trigger Processor (CTP). Each Crate Trigger Processor receives these 500 MB/S VXS links from the 16 FADC-250 modules, aligns skewed data inherent of Aurora protocol, and performs real time crate level trigger algorithms. The algorithm results are encoded using a Reed-Solomon technique and transmission of this Level 1 trigger data is sent to the SSP using a multi-fiber link. The multi-fiber link achieves an aggregate trigger data transfer rate to the global trigger at 8 Gb/s. The SSP receives and decodes Reed-Solomon error correcting transmission from each crate, aligns the data, and performs the global level trigger algorithms. The entire trigger system is synchronous and operates at 250 MHz with the Trigger Supervisor managing not only the front end event readout, but also the distribution of the critical timing clocks, synchronization signals, and the global trigger signals to each front end readout crate. These signals are distributed to the front end crates on a separate fiber link and each crate is synchronized using a unique encoding scheme to guarantee that each front end crate is synchronous with a fixed latency, independent of the distance between each crate. The overall trigger signal latency is <3 uS, and the proposed 12GeV experiments at Jefferson Lab require up to 200KHz Level 1 trigger rate.

43 PARTICLE ACCELERATORS↗

Parallelizing the QUDA Library for Multi-GPU Calculations in Lattice Quantum Chromodynamics

Graphics Processing Units (GPUs) are having a transformational effect on numerical lattice quantum chromodynamics (LQCD) calculations of importance in nuclear and particle physics. The QUDA library provides a package of mixed precision sparse matrix linear solvers for LQCD applications, supporting single GPUs based on NVIDIA's Compute Unified Device Architecture (CUDA). This library, interfaced to the QDP++/Chroma framework for LQCD calculations, is currently in production use on the "9g" cluster at the Jefferson Laboratory, enabling unprecedented price/performance for a range of problems in LQCD. Nevertheless, memory constraints on current GPU devices limit the problem sizes that can be tackled. In this contribution we describe the parallelization of the QUDA library onto multiple GPUs using MPI, including strategies for the overlapping of communication and computation. We report on both weak and strong scaling for up to 32 GPUs interconnected by InfiniBand, on which we sustain in excess of 4 Tflops.

43 PARTICLE ACCELERATORS↗

Structural Analysis of the SHMS Cosine Theta Superconducting Dipole Force Collar

Jefferson Laboratory is developing a set of innovative superconducting magnets for the 12 GeV upgrade in JLAB Hall C. Here, we will report on the finite element analysis (FEA) of the force collar for the Super High Momentum Spectrometer Cosine Theta Dipole magnet. The force collar is designed with an interference fit and intended to provide enough pressure after cool down to operating temperature to counteract Lorentz forces acting on the dipole coil during operation. By counteracting the Lorentz forces and keeping the coil pack in overall compression, movement of the coils is expected to be minimized. The dimensional geometry of the cold mass is maintained in the commercial solid modeling code UG/I-DEAS while the magnetic field design is maintained in the commercial TOSCA code from Vector Fields. The three dimensional FEA was conducted in the commercial codes ANSYS and IDEAS. The method for converting the models and calculating the loads transferred to the structure is discussed. The results show the cold mass response to: force collar assembly preload, differential thermal contraction, and operational Lorentz loads. Evaluations are made for two candidate force collar materials and two candidate force collar designs.

43 PARTICLE ACCELERATORS↗

Convergence Studies of Thermal and Electromagnetic Transient Quench Analysis of 11 GeV Super High Momentum Spectrometer Superconducting Magnets in Jefferson Lab

This paper presents results of convergence studies of transient thermal and electromagnetic quench analysis of five Super High Momentum Spectrometer (SHMS) superconducting magnets: HB, Q1, Q2, Q3, and Dipole, using Vector Fields Quench analysis codes. The convergence of the hot spot temperature and solution solve times were used to investigate the effects of element types, mesh densities, and tolerance criteria. The comparisons between tetrahedral elements and hexahedral elements was studied, and their advantages and disadvantages were discussed. Based on the results of convergence studies, a meshing guideline for coils is presented. The impact of iteration tolerance to the hot spot temperature was also explored, and it is found that tight tolerances result in extremely long solve times with only marginal improvements in the results.

43 PARTICLE ACCELERATORS↗

Design of a Large 5 T Superconducting Magnet for Polarized Target for JLAB Hall B 12 GeV Upgrade Clas12 Detector

Hall B at Jefferson Laboratory (JLAB) will need a 5 T, 78 cm bore polarized target magnet with a field uniformity of {Delta}B/B{sub 0} <; 10{sup -4} in a useful cylinder of the dimensions 0.04 m long x 0.02 m in diameter. The large magnet is designed with a superconducting coil that provides the solenoid with nearly perfect self shielding in order to reduce the fringe field at nearby photo multiplier tubes (PMTs) to less than 3.5 mT. Because the solenoid is also very close to the Clas12 Torus, the nearly perfect shielding provided by the self shielded solenoid greatly reduces force, field, and torque interactions with the six-coil Torus magnet. The solenoid coil consists of 18 coil modules which are made of coils mounted in aluminum plate discs. Each coil module consists of dual double pancake coils with main coils and shield coil partitioned into separate winding cavities in the aluminum plate discs to distribute and reduce radial hoop load and radial coil forces. Each coil module is effectively an enclosed aluminum box and this serves to partition the axial load and thus reduces coil axial forces. Since overall coil forces within each coil module are reduced, this will greatly reduce the number coil training quenches. This is a very important consideration for this solenoid coil because the coil cooling is adiabatic, using in-direct conduction cooling by 4.5 K supercritical helium, which will provide only a relatively small temperature stability margin. Super critical helium is used as per JLAB specification. Detail design of the coil structure, coil assembly, cold mass, and cryogenic control will be presented. The magnet protection system shall be capable of the following features: (1) quench and fault detection, (2) fast discharge of the magnet, (3) limit fault voltages to safe values, (4) monitor interlock signals to prevent unsafe operation, and (5) provide control logic necessary for safe operation of the solenoid. The instrument systems shall be capable of the following features: (1) monitors and display temperatures within the solenoid magnet, (2) measure loads or stress on the magnet suspension, (3) monitor voltages within the solenoid magnet and charging bus, (4) monitor pressures and (5) use data logging system to save all sensor data. These systems will be described and a quench analysis presented.

43 PARTICLE ACCELERATORS↗

Preliminary Design of JLAB Clas12 Large Superconducting Torus Magnet

Hall B at Jefferson Laboratory (JLAB) will need a 6-coil Torus producing a required integral of B-dl for an upgrade 12 GeV beam. In Sept. 2009, Wang NMR was awarded a contract to design, fabricate, assemble, deliver, and test at JLAB this ex citing magnet. The preliminary design review was completed by Dec. 2009 and intermediate design review will be completed by July 2010. Proto type coil construction, production of soldered conductor with SSC cable and final design review will be completed in 2010. We shall describe preliminary design and intermediate design for coil/cryostat, Torus central cylinder (hub), 48 cold mass suspensions, two intercoil support rings, cryocontrol tower, and adapter to Torus coil, magnet quench protection, and charge/ discharge con trol, and the two parallel path cooling design using supercritical helium. Because of coil in-plane and out-of-plane EM forces over these huge thin coils in addition to vacuum load, gravity load, and cool down thermal stress, we shall present the finite element analyses (FEA) on coil structure, 48 cold mass supports, intercoil cold rings, coil/ cryostat vacuum vessel, cryotower cryostat, and Torus hub. Finally, we shall shows that all pressure/ vacuum vessels and its weldment has satisfied ASME code.

43 PARTICLE ACCELERATORS↗

Contribution of meson-exchange currents to the electromagnetic structure of the deuteron at high momentum transfers

The leading term of the asymptotic expansion of the contributions of the {pi}NN and {rho}{pi}{gamma} processes to the electromagnetic form factors of the deuteron at high momentum transfers is calculated. The resulting asymptotic behavior is compared with experimental data obtained at the Thomas Jefferson Laboratory. Constraints on the functional dependence of meson-nucleon vertex functions that ensure a correct asymptotic behavior of deuteron form factors are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Relativistic constituent quark model and experiments at JLab

Within the relativistic-quantum-mechanics version developed by the present authors in their previous studies, the pion electromagnetic form factor is calculated in the region of high momentum transfers reached and planned to be reached in experiments at the Thomas Jefferson Laboratory (JLab). An asymptotic expansion was obtained for the pion form factor for Q{sup 2} {sup {yields} {infinity}}. This expansion describes well existing experimental values and the results of a QCD simulation of future experiments at JLab. It is shown that the region of experiments at JLab is an asymptotic region for the relativistic constituent quark model and that the behavior of the pion form factor, F{sub {pi}}(Q{sup 2})Q{sup 2} = const, can be obtained within this model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tagged-weak {pi} method

A new 'tagged-weak {pi} method' is proposed for determination of electromagnetic transition probabilities B(E2) and B(M1) of the hypernuclear states with lifetimes of {approx}10{sup -10} s. With this method, we are planning to measure B(E2) and B(M1) for light hypernuclei at JLab. The results of Monte Carlo simulations for the case of E2(5/2{sup +}, 3/2{sup +} {yields} 1/2{sup +}) transitions in {sub {Lambda}}{sup 7}He hypernuclei are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise calculations of observables of polarized moller scattering: From JLAB to ILC energies

One-loop electroweak corrections to observables of the reaction e{sup -}e{sup -} {yields} e{sup -}e{sup -}({gamma}) were calculated over a broad range of energies: from conditions of the MOLLER experiment at the Thomas Jefferson Laboratory (JLab) to those of planned experiments at the International Linear Collider (ILC). The dependence of various contributions to the observable polarization asymmetry on various renormalization conditions was studied within the scheme of on-shell renormalization. The results were obtained by two methods: precisely, by applying the FeynArts, FormCalc, LoopTools, and Form computer codes, and approximately, with the aid of the asymptotic-estimation methods. The resulting compact formulas are absolutely free from nonphysical parameters and are convenient for deducing numerical estimates. It is shown that the total one-loop correction is independent of renormalization conditions and takes an identical value within different computational schemes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Estimating two-loop radiative effects in the MOLLER experiment

Within the on-shell renormalization scheme, two-loop electroweak corrections to the parityviolating polarization asymmetry in the reaction e{sup -}e{sup -} {yields} e{sup -}e{sup -}({gamma}, {gamma}{gamma}) were estimated for the MOLLER experiment at JLab. The infrared divergence and the imaginary part of the amplitude were taken completely under control. Relevant compact expressions obtained by using asymptotic methods are free from unphysical parameters and are convenient for analysis and for numerical estimations. A numerical analysis revealed a significant scale of two-loop effects and the need for taking them into account in the MOLLER experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiative Møller scattering involving polarized particles

A method for taking into account radiative events in experiments aimed at studying Møller scattering with polarized particles was developed for an arbitrary implementation of such experiments. A computer code used to perform a numerical analysis with allowance for the kinematical conditions of the MOLLER experiment at the Thomas Jefferson National Accelerator Facility (Jefferson Lab or JLab) was constructed. The respective results were compared with their counterparts obtained in the soft-photon approximation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New method for taking into account radiative events in the MOLLER inclusive experiment

A new method (N-method) for taking into account radiative events in inclusive polarized experiments that, in principle, makes no use of an unphysical separation into soft-and hard-photon regions is demonstrated. A procedure for taking into account bremsstrahlung in theMOLLER forthcoming ultraprecise experiment at the Thomas Jefferson Laboratory is developed on the basis of this method. The algorithm of the method is described in detail, and the results obtained by means of the N method are compared with the results of applying traditional methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

One-loop electroweak corrections for polarized Møller scattering at different renormalization schemes and conditions

Using two different approaches, we perform detailed calculations of the one-loop (Next-to-Leading Order (NLO)) electroweak radiative corrections to the parity violating e{sup −} e{sup −} → e{sup −} e{sup −}(γ) scattering asymmetry. First approach, more classical, relies on calculations “by hand” with reasonable approximations, second approach relies on program packages FeynArts, FormCalc, LoopTools, and FORM. The detailed numerical analysis of the various contributions is provided for a wide range of energies relevant for the ultraprecise 11 GeV MOLLER experiment planned at the JLab, as well as future experiments at the International Linear Collider (ILC). The numerical results obtained within the on-shell renormalization scheme using two different sets of renormalization conditions are in excellent agreement. We also calculate the total NLO correction in the Constrained Differential Renormalization (CDR) scheme. Analysis of the results, along with the increasing experimental precision, shows that it is feasible that the corrections at the Next-to-Next-to-Leading Order (NNLO) level may be important for the next generation of experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The form factors of the nucleons

There has been much activity in the measurement of the elastic electromagnetic proton and neutron form factors in the last decade, and the quality of the data has been greatly improved by performing double-polarization experiments, in comparison with with previous unpolarized cross section data. Here we will review the experimental data base in view of the new results for the proton and the neutron, obtained at MIT-Bates, JLab and MAMI. The rapid evolution of phenomenological models triggered by these high-precision experiments will be discussed. In particular, the possibility that the proton is non-spherical in its ground state, and that the transverse charge density are model independently defined in the infinite momentum frame. Likewise, flavor decomposition of the nucleon form factors into dressed u and d quark form factors, may give information about the quark-diquark structure of the nucleon. The current proton radius “crisis” will also be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SPIN effects, QCD, and Jefferson Laboratory with 12 GeV electrons

QCD and Spin physics are playing important role in our understanding of hadron structure. I will give a short overview of origin of hadron structure in QCD and highlight modern understanding of the subject. Jefferson Laboratory is undergoing an upgrade that will increase the energy of electron beam up to 12 GeV. JLab is one of the leading facilities in nuclear physics studies and once operational in 2015 JLab 12 will be crucial for future of nuclear physics. I will briefly discuss future studies in four experimental halls of Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗