Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Calibrating uncertain parameters in melt pool simulations of additive manufacturing

Melt pool scale numerical modeling of additive manufacturing (AM) processes can provide predictive capabilities and theoretical insight into the process-property-structure-performance relationships for AM parts. Despite capabilities of numerical models to solve complex multi-physics problems, it is often important to consider a tradeoff between detailed physics and computational cost. Therefore, sources of uncertainty in both experimental conditions and the parameters needed for modeling require models to be validated against empirical evidence. Here, a method is proposed to calibrate uncertain parameters used in continuum-scale melt pool models for powder bed fusion (PBF) AM. Both a simplified heat transfer model and a heat transfer and fluid flow model were investigated. A surrogate model and Markov chain-based optimization algorithm calibrated melt pool geometry for models within experimental variation of the target melt pool width and depth from the NIST AM-Bench 2018-02 dataset. The melt pool temperature distributions, solidification parameters, and simulated multi-layer solidification microstructures were compared between the two models. Similar results from both models indicate that calibrated, lower fidelity numerical models may be used in place of higher fidelity models to generate melt pool solidification data. Finally, these calibrated models therefore enable lower computational cost melt pool simulations without a noticeable decrease in simulation accuracy for grain-scale microstructure simulations.

36 MATERIALS SCIENCE↗

Single x-ray transmission system for bone mineral density determination

Bones are the support of the body. They are composed of many inorganic compounds and other organic materials that all together can be used to determine the mineral density of the bones. The bone mineral density is a measure index that is widely used as an indicator of the health of the bone. A typical manner to evaluate the quality of the bone is a densitometry study; a dual x-ray absorptiometry system based study that has been widely used to assess the mineral density of some animals' bones. However, despite the success stories of utilizing these systems in many different applications, it is a very expensive method that requires frequent calibration processes to work properly. Moreover, its usage in small species applications (e.g., rodents) has not been quite demonstrated yet. Following this argument, it is suggested that there is a need for an instrument that would perform such a task in a more reliable and economical manner. Therefore, in this paper we explore the possibility to develop a new, affordable, and reliable single x-ray absorptiometry system. The method consists of utilizing a single x-ray source, an x-ray image sensor, and a computer platform that all together, as a whole, will allow us to calculate the mineral density of the bone. Utilizing an x-ray transmission theory modified through a version of the Lambert-Beer law equation, a law that expresses the relationship among the energy absorbed, the thickness, and the absorption coefficient of the sample at the x-rays wavelength to calculate the mineral density of the bone can be advantageous. Having determined the parameter equation that defines the ratio of the pixels in radiographies and the bone mineral density [measured in mass per unit of area (g/cm{sup 2})], we demonstrated the utility of our novel methodology by calculating the mineral density of Wistar rats' femur bones.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Tip of the red giant branch distance to the perfect spiral galaxy M74 hosting three core-collapse supernovae

M74 (NGC 628) is a famous face-on spiral galaxy, hosting three core-collapse supernovae (SNe): SN Ic 2002ap, SN II-P 2003gd, and SN II-P 2013ej. However, its distance is not well known. We present a distance estimation for this galaxy based on the Tip of the Red Giant Branch (TRGB) method. We obtain photometry of the resolved stars in the arm-free region of M74 from F555W and F814W images in the Hubble Space Telescope archive. The color-magnitude diagram of the resolved stars shows a dominant red giant branch (RGB) as well as blue main sequence stars, red helium burning stars, and asymptotic giant branch stars. The I-band luminosity function of the RGB stars shows the TRGB to be at I {sub TRGB} = 26.13 ± 0.03 mag, and T {sub RGB} = 25.97 ± 0.03. From this, we derive the distance modulus to M74 to be 30.04 ± 0.04 (random) ± 0.12 (systematic) (corresponding to a linear distance of 10.19 ± 0.14 ± 0.56 Mpc). With this distance estimate, we calibrate the standardized candle method for SNe II-P. From the absolute magnitudes of SN 2003gd, we derive a value of the Hubble constant, H {sub 0} = 72 ± 6 (random) ± 7 (systematic) km s{sup –1} Mpc{sup –1}. It is similar to recent estimates based on the luminosity calibration of Type Ia supernovae.

79 ASTRONOMY AND ASTROPHYSICS↗

KEPLER INPUT CATALOG: PHOTOMETRIC CALIBRATION AND STELLAR CLASSIFICATION

We describe the photometric calibration and stellar classification methods used by the Stellar Classification Project to produce the Kepler Input Catalog (KIC). The KIC is a catalog containing photometric and physical data for sources in the Kepler mission field of view; it is used by the mission to select optimal targets. Four of the visible-light (g, r, i, z) magnitudes used in the KIC are tied to Sloan Digital Sky Survey magnitudes; the fifth (D51) is an AB magnitude calibrated to be consistent with Castelli and Kurucz (CK) model atmosphere fluxes. We derived atmospheric extinction corrections from hourly observations of secondary standard fields within the Kepler field of view. For these filters and extinction estimates, repeatability of absolute photometry for stars brighter than magnitude 15 is typically 2%. We estimated stellar parameters {l_brace}T{sub eff}, log (g), log (Z), E{sub B-V}{r_brace} using Bayesian posterior probability maximization to match observed colors to CK stellar atmosphere models. We applied Bayesian priors describing the distribution of solar-neighborhood stars in the color-magnitude diagram, in log (Z), and in height above the galactic plane. Several comparisons with samples of stars classified by other means indicate that for 4500 K {<=}T{sub eff} {<=} 6500 K, our classifications are reliable within about {+-}200 K and 0.4 dex in log (g) for dwarfs, with somewhat larger log (g) uncertainties for giants. It is difficult to assess the reliability of our log (Z) estimates, but there is reason to suspect that it is poor, particularly at extreme T{sub eff}. Comparisons between the CK models and observed colors are generally satisfactory with some exceptions, notably for stars cooler than 4500 K. Of great importance for the Kepler mission, for T{sub eff} {<=} 5400 K, comparison with asteroseismic results shows that the distinction between main-sequence stars and giants is reliable with about 98% confidence. Larger errors in log (g) occur for warmer stars, for which our filter set provides inadequate gravity diagnostics. The KIC is available through the MAST data archive.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal measurement strategies for effective suppression of drift errors

Drifting of experimental setups with change in temperature or other environmental conditions is the limiting factor of many, if not all, precision measurements. The measurement error due to a drift is, in some sense, in-between random noise and systematic error. In the general case, the error contribution of a drift cannot be averaged out using a number of measurements identically carried out over a reasonable time. In contrast to systematic errors, drifts are usually not stable enough for a precise calibration. Here a rather general method for effective suppression of the spurious effects caused by slow drifts in a large variety of instruments and experimental setups is described. An analytical derivation of an identity, describing the optimal measurement strategies suitable for suppressing the contribution of a slow drift described with a certain order polynomial function, is presented. A recursion rule as well as a general mathematical proof of the identity is given. The effectiveness of the discussed method is illustrated with an application of the derived optimal scanning strategies to precise surface slope measurements with a surface profiler.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A TECHNIQUE FOR PRIMARY BEAM CALIBRATION OF DRIFT-SCANNING, WIDE-FIELD ANTENNA ELEMENTS

We present a new technique for calibrating the primary beam of a wide-field, drift-scanning antenna element. Drift-scan observing is not compatible with standard beam calibration routines, and the situation is further complicated by difficult-to-parameterize beam shapes and, at low frequencies, the sparsity of accurate source spectra to use as calibrators. We overcome these challenges by building up an interrelated network of source 'crossing points'-locations where the primary beam is sampled by multiple sources. Using the single assumption that a beam has 180 Degree-Sign rotational symmetry, we can achieve significant beam coverage with only a few tens of sources. The resulting network of crossing points allows us to solve for both a beam model and source flux densities referenced to a single calibrator source, circumventing the need for a large sample of well-characterized calibrators. We illustrate the method with actual and simulated observations from the Precision Array for Probing the Epoch of Reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Prediction of gas hydrate saturation using machine learning and optimal set of well-logs

We report resistivity and acoustic logs are widely used to estimate gas hydrate saturation in various sedimentary systems using one of the two popular methods ((1) acoustic velocity and (2) electrical resistivity), but the limitations of these two methods are often overlooked, which include (i) well-specific calibration of empirical exponents in the electrical resistivity method, (ii) assumption of known pore morphology for gas hydrates in the acoustic velocity method, and (iii) presence of unknown mineralogy and bulk modulus terms in the acoustic velocity method. NMR-density porosity-derived gas hydrate saturation based on the analysis of the transverse magnetization relaxation time (T2) is considered the most precise method, but acquisition of NMR-based logs is limited at relatively recent drilled sites; additionally, its use in conventional oil and gas reservoirs is not that common due to higher cost and operational deployment limitations associated with acquiring NMR well-logs. This study proposes a new method that predicts gas hydrate saturation (S h ) for any well using porosity, bulk density, and compressional wave (P wave) velocity well-logs with neural network (or stochastic gradient descent regression) without any well-specific calibration and/or other aforementioned shortcomings of the existing methods. The method is developed by examining the underlying dependency between S h and different combinations of well-logs, chosen from 6 routine logs, with 12 different machine learning (ML) algorithms. The accuracy of the proposed method in predicting S h is ~ 84%, which is better than the accuracy of seismic and electrical resistivity methods (≤ 75%) per the results reported by three different studies. The robustness of the method in the specific case of permafrost-associated gas hydrates is demonstrated with well-log data from two wells drilled on the Alaska North Slope.

58 GEOSCIENCES↗

Calibration of AGN Reverberation Distance Measurements

In Yoshii et al., we described a new method for measuring extragalactic distances based on dust reverberation in active galactic nuclei (AGNs), and we validated our new method with Cepheid variable stars. In this Letter, we validate our new method with Type Ia supernovae (SNe Ia) that occurred in two of the AGN host galaxies during our AGN monitoring program: SN 2004bd in NGC 3786 and SN 2008ec in NGC 7469. Their multicolor light curves were observed and analyzed using two widely accepted methods for measuring SN distances, and the distance moduli derived are μ=33.47±0.15 for SN 2004bd and 33.83 ± 0.07 for SN 2008ec. These results are used to obtain independently the distance measurement calibration factor, g. The g value obtained from the SN Ia discussed in this Letter is g{sub SN}=10.61±0.50, which matches, within the range of 1σ uncertainty, g{sub DUST}=10.60, previously calculated ab initio in Yoshii et al. Having validated our new method for measuring extragalactic distances, we use our new method to calibrate reverberation distances derived from variations of Hβ emission in the AGN broad-line region, extending the Hubble diagram to z≈0.3 where distinguishing between cosmologies is becoming possible.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating dynamic thermal performance of building envelope components using small-scale calibrated hot box tests

The hot box test method has been applied to evaluate both the steady-state (U-value) and dynamic thermal properties of building envelopes. However, the high construction cost of full-scale hot box apparatus and the testing time required (usually several days) may prevent its wider adoption. To overcome the limitations of full-scale hot box tests, here we propose a novel method to evaluate the dynamic thermal performance of building envelope components using a small-scale calibrated hot box and scaled-down specimen. In this paper, the scaling relationships of thermal properties evaluated using a full-size specimen and a scaled-down specimen are established based on the Laplace transform of the heat transfer equations. In addition, dynamic thermal properties obtained from scaled-down experimental tests are compared to the values calculated by the EN ISO13768 (ISO) method. A small-scale hot box with a 355 mm × 355 mm metering area was constructed and calibrated to validate the correlations. Three scaled-down concrete sandwich wall panels were then tested and the scaling relationship was cross-validated using the experimental results, finite difference (FD) simulations, and the ISO method. The results indicate that the dynamic thermal properties obtained from a scaled-down hot box test can be correlated to its full-size counterpart when certain conditions are met. The scaled-down hot box test is demonstrated to be an effective yet economical alternative to a full-scale test with significantly reduced experimentation cost and turn-around time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benchmarking the performance of uncertainty quantification methods for neural network-based interatomic potentials

Machine-learned interatomic potentials (ML-IAPs) continue to gain popularity as accurate, computationally efficient replacements for traditional, physics-based interatomic potentials and expensive ab initio methods. Uncertainty quantification (UQ) of ML-IAPs is a growing area of research as UQ is critical in many applications of IAPs, such as developing curated datasets, active learning-based data augmentation, self-improving models, and estimating the uncertainty of molecular dynamics simulations. In this paper, we construct and benchmark a series of different neural network potentials (NNPs) with varying network architectures to determine the performance of these models with respect to both the mean and uncertainty calibration error. Each NNP method is specifically designed to predict either epistemic or aleatoric uncertainty with particular focus on the differences in behavior between the epistemic and aleatoric uncertainty estimates. We benchmark these methods using multiple datasets common in the ML-IAP literature. The results show that the aleatoric uncertainty from single-shot model architectures is a competitive alternative to ensemble-based epistemic uncertainty predictions in regions of sufficient data-density. However, in regions where the representative data is sparse, aleatoric uncertainty models tend to overpredict and epistemic methods tend to underpredict the actual model error. We conclude that the type of UQ is crucial when discussing performance of probabilistic model results as different methods have different performance characteristics depending on the regime in which they are evaluated. Therefore, the type of UQ method should be carefully evaluated against both the data characteristics and requirements for the intended application.

97 MATHEMATICS AND COMPUTING↗

Calibrations for charged particle tracking and measurements of w photoproduction with the GlueX detector

The GlueX experiment is a new experimental facility at Jefferson Lab in Newport News, VA. The experiment aims to map out the spectrum of hybrid mesons in the light quark sector. Measurements of the spin-density matrix elements in omega photoproduction are performed with a linear polarized photon beam on an unpolarized proton target, and presented in bins of Mandelstam t for beam energies of 8.4-9.0 GeV. The spin-density matrix elements are exclusively measured through two decays of the omega meson: omega -> pi^+ pi^- pi^0 and omega ->pi^0 gamma. A description of the experimental apparatus is presented. Several methods used in the calibration of the charged particle tracking system are described. These measurements greatly improve the world statistics in this energy range. These are the first results measured through the omega ->pi^0 gamma decay at this energy. Results are generally consistent with a theoretical model based on diffractive production with Pomeron and pseudoscalar exchange in the t-channel.

Staib, Michael↗

Proposal of in situ density calibration for Thomson scattering measurement by microwave reflectometry

A density calibration using microwave reflectometry for a Thomson scattering measurement is proposed. The calibration can be performed in parallel with a plasma experiment. A compact and simple FM-type reflectometer is preferable due to the small space around the Thomson scattering device. A Bayesian estimation method is also proposed for the derivation of the calibration factor. The Bayesian method requires fewer data from the reflectometer than an average method for an accurate density calibration factor, which is confirmed by a Monte Carlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying Groundwater Response and Uncertainty in Beaver‐Influenced Mountainous Floodplains Using Machine Learning‐Based Model Calibration

Abstract Beavers ( Castor canadensis ) alter river corridor hydrology by creating ponds and inundating floodplains, and thereby improving surface water storage. However, the impact of inundation on groundwater, particularly in mountainous alluvial floodplains with permeable gravel/cobble layers overlain by a soil layer, remains uncertain. Numerical modeling across various floodplain structures considers topographic and sediment complexity and multidirectional flow, linking inundation to groundwater response. This study develops a model‐data integration workflow to address uncertainty in groundwater response to beaver‐induced inundations in a mountainous alluvial floodplain in the Upper Colorado River Basin. Uncertain factors include seasonal hydrologic dynamics, hydraulic conductivities, floodplain structures, and meteorological forcings. We employed an ensemble of groundwater models, based on geophysical and hydrologic data, with machine learning‐based calibration using a neural density estimator. This allowed us to quantify the vertical flux from the soil layer to the permeable gravel bed, the down‐valley underflow within the gravel bed, and their ratios. Results show a significant increase in the vertical flux relative to down‐valley underflow, from 2 during dry pond periods to 20 during wet periods, serving as an analogy for conditions without and with beaver ponds. The study highlights the influence of floodplain structure on groundwater storage, water balance, and water quality impacted by beaver ponds. A thick gravel bed layer, with a large down‐valley underflow, minimizes the effect of beaver‐induced inundation on water quality. We emphasize the need for field‐scale measurements of floodplain structure and improved characterization of evapotranspiration changes to reduce uncertainty in groundwater response. Plain Language Summary Beavers change the flow of water in river corridors by creating ponds, expanding wetlands, and flooding floodplains. This increases surface water area, promotes plant growth, and enhances biodiversity. However, the impact of this flooding on groundwater flow is not well understood, especially in mountainous areas with gravel layers where water moves easily beneath soil. In this study, we used numerical modeling to investigate how beaver ponds influence groundwater in a mountainous floodplain of the Upper Colorado River Basin. We adapted a machine learning method to validate our numerical models using multiple field data sets. Our findings show that beaver ponds significantly increase vertical water flow from the soil to the gravel during wet periods, compared to when the ponds are fully drained. The study also highlights the importance of floodplain structure in controlling both water flow in gravel layers along the river direction and vertical flow from the soil to the gravel with the presence of beavers. To reduce uncertainty in groundwater response, we emphasize the need for more field‐scale measurements of floodplain structure, hydraulic properties, and evapotranspiration changes. Key Points Floodplain structures and hydraulic conductivities are important for groundwater response with beaver ponds in mountainous floodplains Large down‐valley underflow in permeability‐stratified floodplains reduces beaver‐induced impacts on groundwater storage and water quality Machine learning‐based model calibration methods are effective for estimating posterior distributions of groundwater model parameters

Wang, Lijing↗

A LIBS method for simultaneous monitoring of the impurities and the hydrogenic composition present in the wall of the TJ-II stellarator

The study of plasma-wall interactions and impurity transport in the plasma fusion devices is critical for the development of future fusion reactors. An experiment to perform laser induced breakdown spectroscopy, using minor modifications of our existing laser blow-off impurity injection system, has been set up thus making both experiments compatible. The radiation produced by the laser pulse focused at the TJ-II wall evaporates a surface layer of deposited impurities and the subsequent radiation produced by the laser-produced plasma is collected by two separate lens and fiber combinations into two spectrometers. The first spectrometer, with low spectral resolution, records a spectrum from 200 to 900 nm to give a survey of impurities present in the wall. The second one, with high resolution, is tuned to the wavelengths of the Hα and Dα lines in order to resolve them and quantify the hydrogen isotopic ratio present on the surface of the wall. The alignment, calibration, and spectral analysis method will be described in detail. First experimental results obtained with this setup will be shown and its relevance for the TJ-II experimental program discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-207: Comparison of Integrated Tissue Air Ratio (ITAR) to Traditional TAR for Kilovoltage Pencil-Beams

Purpose: Clinically viable depth dose determination in kilovoltage pencil-beams is a great challenge that resulted in a published dosimetry method called ITAR, which involves measurement of air kerma and attenuation with a detector in a low scatter environment coupled with MCNP scatter calculations. The objective of this work is to compare ITAR to traditional TAR using inherently water-proof microchambers that have only recently become commercially available. Methods: An Exradin A26 microchamber was centered 150 mm from a 100 kVp x-ray source with 2 mm aluminum HVL. Depth dose in water from 16 to 24 mm in 2 mm increments was determined by: (1) placing blocks of Plastic Water LR near the source to minimize scatter and using previously published conversion coefficients [ITAR method] and (2) submerging the detector in a water tank with 2 mm thick Plastic Water LR walls and jogging the tank with motor controllers while keeping the detector position fixed [traditional TAR method]. Each method was repeated four to five times. For each repetition, dose was measured free in-air to normalize the data for exponential regression. Results: Traditional TAR indicated higher depth dose than ITAR; differences ranged from 2.1% at 24 mm depth to 2.5% at 16 mm depth. However, the results of traditional TAR did not include a correction for Pq,cham because it is unknown for this detector type in these conditions. It is estimated that the component of Pq,cham due to the effect of water displacement alone is ∼0.94, but Pq,cham is likely several percent larger than 0.94 due to the energy dependency of the microchamber in the presence of low energy scatter that is not present during in-air calibration. Conclusion: The ITAR method remains preferable for clinical depth dose determination in kilovoltage pencil-beams due to Pq,cham being unknown for suitable detectors in relevant conditions. All four of the authors are either current full time employees, which include stock option grants, or consultants of Oraya Therapeutics Inc.

60 APPLIED LIFE SCIENCES↗

Thoron detection with an active Radon exposure meter—First results

For state-of-the-art discrimination of Radon and Thoron several measurement techniques can be used, such as active sampling, electrostatic collection, delayed coincidence method, and alpha-particle-spectroscopy. However, most of the devices available are bulky and show high power consumption, rendering them unfeasible for personal exposition monitoring. Based on a Radon exposure meter previously realized at the Helmholtz Center Munich (HMGU), a new electronic prototype for Radon/Thoron monitoring is currently being developed, which features small size and weight. Operating with pin-diode detectors, the low-power passive-sampling device can be used for continuous concentration measurements, employing alpha-particle-spectroscopy and coincidence event registration to distinguish decays originating either from Radon or Thoron isotopes and their decay products. In open geometry, preliminary calibration measurements suggest that one count per hour is produced by a 11 Bq m{sup −3} Radon atmosphere or by a 15 Bq m{sup −3} Thoron atmosphere. Future efforts will concentrate on measurements in mixed Radon/Thoron atmospheres.

54 ENVIRONMENTAL SCIENCES↗

Optimization of the first order gradiometer for small sample magnetization measurements using pulse integrating magnetometer

In the paper we present an analytical calculation method for determination of the sensitivity of a pulse field magnetometer working with a first order gradiometer. Our considerations here are especially focused on a case of magnetic moment measurements of very small samples. Derived in the work analytical equations allow for a quick estimation of the magnetometer's sensitivity and give also the way to its calibration using the sample simulation coil method. On the base of the given in the paper calculations we designed and constructed a simple homemade magnetometer and performed its sensitivity calibration.

36 MATERIALS SCIENCE↗

AN ASSESSMENT OF SUNSPOT NUMBER DATA COMPOSITES OVER 1845–2014

New sunspot data composites, some of which are radically different in the character of their long-term variation, are evaluated over the interval 1845–2014. The method commonly used to calibrate historic sunspot data, relative to modern-day data, is “daisy-chaining,” whereby calibration is passed from one data subset to the neighboring one, usually using regressions of the data subsets for the intervals of their overlap. Recent studies have illustrated serious pitfalls in these regressions, and the resulting errors can be compounded by their repeated use as the data sequence is extended back in time. Hence, the recent composite data series by Usoskin et al., R {sub UEA}, is a very important advance because it avoids regressions, daisy-chaining, and other common, but invalid, assumptions: this is achieved by comparing the statistics of “active-day” fractions to those for a single reference data set. We study six sunspot data series, including R {sub UEA} and the new “backbone” data series ( R {sub BB}, recently generated by Svalgaard and Schatten by employing both regression and daisy-chaining). We show that all six can be used with a continuity model to reproduce the main features of the open solar flux variation for 1845–2014, as reconstructed from geomagnetic activity data. However, some differences can be identified that are consistent with tests using a basket of other proxies for solar magnetic fields. Using data from a variety of sunspot observers, we illustrate problems with the method employed in generating R {sub BB} that cause it to increasingly overestimate sunspot numbers going back in time, and we recommend using R {sub UEA} because it employs more robust procedures that avoid such problems.

79 ASTRONOMY AND ASTROPHYSICS↗