Search NASA⌕ Search

SEARCH · Search NASA

Results for “DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A Next-Generation Hard X-Ray Nanoprobe Beamline for In Situ Studies of Energy Materials and Devices

The Advanced Photon Source is developing a suite of new X-ray beamlines to study materials and devices across many length scales and under real conditions. One of the flagship beamlines of the APS upgrade is the In Situ Nanoprobe (ISN) beamline, which will provide in situ and operando characterization of advanced energy materials and devices under varying temperatures, gas ambients, and applied fields, at previously unavailable spatial resolution and throughput. Examples of materials systems include inorganic and organic photovoltaic systems, advanced battery systems, fuel cell components, nanoelectronic devices, advanced building materials and other scientifically and technologically relevant systems. To characterize these systems at very high spatial resolution and trace sensitivity, the ISN will use both nanofocusing mirrors and diffractive optics to achieve spots sizes as small as 20 nm. Nanofocusing mirrors in Kirkpatrick–Baez geometry will provide several orders of magnitude increase in photon flux at a spatial resolution of 50 nm. Diffractive optics such as zone plates and/or multilayer Laue lenses will provide a highest spatial resolution of 20 nm. Coherent diffraction methods will be used to study even small specimen features with sub-10 nm relevant length scale. A high-throughput data acquisition system will be employed to significantly increase operations efficiency and usability of the instrument. The ISN will provide full spectroscopy capabilities to study the chemical state of most materials in the periodic table, and enable X-ray fluorescence tomography. In situ electrical characterization will enable operando studies of energy and electronic devices such as photovoltaic systems and batteries. We also describe the optical concept for the ISN beamline, the technical design, and the approach for enabling a broad variety of in situ studies. Furthermore, we discuss the application of hard X-ray microscopy to study defects in multi-crystalline solar cells, one of the lines of inquiries for which the ISN is being developed.

42 ENGINEERING↗

Millimeter-scale gate-tunable graphene nanoribbon devices as a platform for mid-infrared and bio sensing applications

The experimental observation of graphene plasmon resonance has generated tremendous interest due to numerous potential applications such as photosensors, detectors, biosensors, and switches from THz to mid-infrared regime. However, practical applications require much larger dimensions (mm to cm scale) than that demonstrated in the proof-of-concept devices. Moreover, such devices also require a detailed understanding of ribbon-to-ribbon interaction, which has not been investigated so far. Here in this paper we demonstrate gate tunable plasmon resonance in the mid-infrared spectral region on millimeter-scale graphene nanoribbon (GNR) array devices fabricated using graphene monolayer. Gate dependent Fourier-transform infrared (FTIR) transmission measurements on GNR of various widths were investigated experimentally. The shift in plasmon resonance peaks of wave number 100 cm -1 at applied external gate voltage -100 V was observed. This shift is attributed to strong gate modulation. Our investigation of ribbon-to-ribbon interaction by tuning the aspect ratio reveals strong modulation of surface plasmon resonance peaks in GNR. This suggests that plasmon resonances are coupled as evidenced by blue-shifted plasmon resonance. These studies demonstrate that large-area GNR devices can serve as an ideal platform for ultrasensitive sensing and detector applications.

36 MATERIALS SCIENCE↗

Industrial control system device classification using network traffic features and neural network embeddings

Characterization of modern cyber–physical Industrial Control System (ICS) devices is critical to the evaluation of their security posture and an understanding of the underlying industrial processes with which they interact. In this work, we address two related ICS device identification tasks: (1) separating ICS from non-ICS devices and (2) identifying specific ICS device types. We propose two distinct methods (one based on the existing IP2Vec method, and a novel traffic-features-based method) for achieving the first task. For transferability of the first task between two datasets, the traffic-features-based method performs significantly better (75% overall accuracy) compared to IP2Vec (22.5% overall accuracy). We further propose a novel method called DNP2Vec to address the second task. DNP2Vec is evaluated on two different datasets and achieves perfect multi-class classification accuracy (100%) for both datasets.

42 ENGINEERING↗

A monolayer microfluidic device supporting mouse spermatogenesis with improved visibility

In our previous study, we produced a microfluidic device (MFD) which successfully maintained spermatogenesis for over 6 months in mouse testis tissues loaded in the device. In the present study, we developed a new MFD, a monolayer device (ML-D) with a barrier structure consisting of pillars and slits, which is simpler in design and easier to make. This ML-D was also effective for inducing mouse spermatogenesis and maintained it for a longer period than the conventional culture method. In addition, we devised a way of introducing sample tissue into the device during its production, just before bonding the upper layer of polydimethylsiloxane (PDMS) and bottom glass slide. The tissue can obtain nutrients horizontally from the medium running beside it and oxygen vertically from above through PDMS. In addition, the glass slide set at the bottom improved the visibility of the sample tissue with an inverted microscope. When we took photos of cultured tissue of the Acr-Gfp transgenic mouse testis in ML-D sequentially every day, morphological changes of the acrosome during spermiogenesis were successfully recorded. The ML-D is simple in design and useful for culturing testis tissue for inducing and maintaining spermatogenesis with clearer visibility. Due to the new method of sample loading, tissues other than testis should also be applicable.

60 APPLIED LIFE SCIENCES↗

Thermal comfort evaluated for combinations of energy-efficient personal heating and cooling devices

Personal comfort systems (PCS) have potential to fulfill building occupants' personal thermal comfort preferences with great efficiency. But to integrate them into building conditioning, there must be a broader selection of PCS devices available. Design guidance and standards are needed to assure that such devices provide high levels of comfort effectiveness and energy efficiency. This study addresses these needs. A suite of minimum-power PCS devices was built that target body parts significant to alliesthesia—a heated shoe insole, heated/cooled wristpad, small deskfan, and heated/cooled chair. They were tested in a climate chamber under cool and warm conditions using both thermal-manikin and human-subjects. Their efficiency at physically heating/cooling the body is high; the combined suite has a coefficient of performance (COP) of 3.6 for cooling and 0.88 for heating. The subjects' whole-body thermal acceptance and thermal comfort perception were improved by the devices in an additive manner; using the combined suite over 80% of people accepted ambient temperatures of 18°C and 29°C. The PCS ‘corrects’ the ambient temperature towards thermal neutrality by as much as 6.5 K cooling and 3.6 K heating, overcoming building occupants' typical interpersonal thermal differences and making possible large HVAC energy savings in buildings. The idea of temperature corrective power can be the basis of standards for PCS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The environmental interactions of tidal and wave energy generation devices

Global energy demand continues to grow and tidal and wave energy generation devices can provide a significant source of renewable energy. Technological developments in offshore engineering and the rising cost of traditional energy means that offshore energy resources will be economic in the next few years. While there is now a growing body of data on the ecological impacts of offshore wind farms, the scientific basis on which to make informed decisions about the environmental effects of other offshore energy developments is lacking. Tidal barrages have the potential to cause significant ecological impacts particularly on bird feeding areas when they are constructed at coastal estuaries or bays. Offshore tidal stream energy and wave energy collectors offer the scope for developments at varying scales. They also have the potential to alter habitats. A diversity of designs exist, including floating, mid-water column and seabed mounted devices, with a variety of moving-part configurations resulting in a unique complex of potential environmental effects for each device type, which are discussed to the extent possible. - Highlights: Black-Right-Pointing-Pointer We review the environmental impacts of tidal barrages and fences, tidal stream farms and wave energy capture devices. Black-Right-Pointing-Pointer Impacts on habitats, species and the water column, and effects of noise and electromagnetic fields are considered. Black-Right-Pointing-Pointer Tidal barrages can cause significant impacts on bird feeding areas when constructed at coastal estuaries or bays. Black-Right-Pointing-Pointer Wave energy collectors can alter water column and sea bed habitats locally and over large distances.

16 TIDAL AND WAVE POWER↗

Symptoms and the use of wireless communication devices: A prospective cohort study in Swiss adolescents

Background: We investigated whether radiofrequency electromagnetic fields (RF-EMF) from mobile phones and other wireless devices or by the wireless device use itself due to non-radiation related factors in that context are associated with an increase in health symptom reports of adolescents in Central Switzerland. Methods: In a prospective cohort study, 439 study participants (participation rate: 36.8%) aged 12–17 years, completed questionnaires about their mobile and cordless phone use, their self-reported symptoms and possible confounding factors at baseline (2012/2013) and one year later (2013/2014). Operator recorded mobile phone data was obtained for a subgroup of 234 adolescents. RF-EMF dose measures considering various factors affecting RF-EMF exposure were computed for the brain and the whole body. Data were analysed using a mixed-logistic cross-sectional model and a cohort approach, where we investigated whether cumulative dose over one year was related to a new onset of a symptom between baseline and follow-up. All analyses were adjusted for relevant confounders. Results: Participation rate in the follow-up was 97% (425 participants). In both analyses, cross-sectional and cohort, various symptoms tended to be mostly associated with usage measures that are only marginally related to RF-EMF exposure such as the number of text messages sent per day (e.g. tiredness: OR:1.81; 95%CI:1.20–2.74 for cross-sectional analyses and OR:1.87; 95%CI:1.04–3.38 for cohort analyses). Outcomes were generally less strongly or not associated with mobile phone call duration and RF-EMF dose measures. Conclusions: Stronger associations between symptoms of ill health and wireless communication device use than for RF-EMF dose measures were observed. Such a result pattern does not support a causal association between RF-EMF exposure and health symptoms of adolescents but rather suggests that other aspects of extensive media use are related to symptoms. - Highlights: • This is a prospective cohort study with approximately one year of follow-up. • Self-reported and operator recorded mobile phone use data were collected. • The cumulative RF-EMF dose for the brain and for the whole body was calculated. • Associations were stronger for the use of wireless devices than for RF-EMF dose. • This suggests that rather aspects of extensive media use than RF-EMF are related to symptoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Clinical Experience With the Strut-Adjusted Volume Implant (SAVI) Breast Brachytherapy Device for Accelerated Partial-Breast Irradiation (APBI): First 100 Patients With More Than 1 Year of Follow-Up

Purpose: The Strut-Adjusted Volume Implant (SAVI; Cianna Medical, Aliso Viejo, CA) is a multichannel single-entry brachytherapy device designed to allow dose modulation to minimize normal tissue dose while simultaneously maximizing target coverage. This is the first report on the initial 102 patients with nearly 2 years of median follow-up. Methods and Materials: One hundred two patients were treated at two institutions. Data were collected on eligibility and dosimetry and followed for toxicity and recurrence. Results: The median follow-up is 21 months. Overall dosimetry is outstanding (median percent of target volume receiving 90% of the prescription dose was 95.9%, volume of target receiving 150% of the prescription dose was 27.8 mL, and volume of target receiving 200% of the prescription dose was 14.0 cm{sup 3}). No devices were pulled prior to treatment completion. For patients with a skin bridge of less than 7 mm, the maximum median skin dose was 280 cGy (median percent of target volume receiving 90% of the prescription dose was 95.2%, volume of target receiving 150% of the prescription dose was 25.8 cm{sup 3} and volume of target receiving 200% of the prescription dose was 12.7 mL). For patients with both chest wall and skin of less than 7 mm, the maximum median lung dose was 205 cGy with simultaneous skin dose of 272 cGy. The rate of telangiectasia was 1.9%. Grade 1 hyperpigmentation developed in 10 patients (9.8%) and Grade 2 fibrosis in 2 patients (1.9%). There were 2 symptomatic seromas and 2 cases of asymptomatic fat necrosis (1.9%). Of the patients, 27% were not eligible for MammoSite balloon brachytherapy (Hologic, Inc., Marlborough, MA) and 5% were not eligible for any balloon brachytherapy. The recurrence rate was 1%. Conclusions: The SAVI appears to safely allow an increase in eligibility for APBI over balloon brachytherapy or three-dimensional conformal radiation, highlighting the outstanding device flexibility to maximize the target dose and minimize the normal tissue dose. The device was well tolerated by patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Memristive behavior and forming mechanism of homogeneous TiO{sub x} device

Highlights: • We fabricated a homogeneity TiO{sub x} device with excellent memristive behavior. • The double-interface conductive filament model is suggested. • The calculated I–V curve is in agreement with the experimental results. • The switching voltage could be adjusted by selecting the proper electrode materials. - Abstract: A homogeneous titanium oxide device is fabricated by Molecular Beam Epitaxy and the excellent memristive behavior could be observed. The resistance ratio between high resistance state and low resistance state increases as the thickness of titanium oxide or the oxygen content reduces. The forming voltage is lower than the previous report. Based on the experimental results, we suggest a double-interface conductive filament model and calculate the current–voltage curve of the device in agreement with experimental measurements. The result indicates that the forming voltage of the device will rise with increasing of the chemical potential differences across the two interfaces. In other words, the switching voltage could be adjusted by selecting a proper electrode and oxide materials.

36 MATERIALS SCIENCE↗

Hybrid device based on GaN nanoneedles and MEH-PPV/PEDOT:PSS polymer

Highlights: • A hybrid device was demonstrated by using MEH-PPV, PEDOT:PSS, and GaN nanoneedles. • I–V curve of the hybrid device showed its rectification behaviour, similar to a diode. • EL peak originated by the different potential barriers at MEH-PPV and GaN interface. - Abstract: A hybrid device that combines the properties of organic and inorganic semiconductors was fabricated and studied. It incorporated poly[2-methoxy-5-(2-ethylhexyloxy)- 1,4-phenylenevinylene] (MEH-PPV) and poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) as organic polymers and GaN nanoneedles as an inorganic semiconductor. Layers of the two polymers were spin coated on to the GaN nanoneedles. The one peak in the electroluminescence spectrum originated from the MEH-PPV layer owing to the different potential barriers of electrons and holes at its interface with the GaN nanoneedles. However, the photoluminescence spectrum showed peaks due to both GaN nanoneedles and MEH-PPV. Such hybrid structures, suitably developed, might be able to improve the efficiency of optoelectronic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Evaluation of two intracavitary high-dose-rate brachytherapy devices for irradiating additional and irregularly shaped volumes of breast tissue

The SAVI and Contura breast brachytherapy applicators represent 2 recent advancements in brachytherapy technology that have expanded the number of women eligible for accelerated partial breast irradiation in the treatment of early-stage breast cancer. Early clinical experience with these 2 single-entry, multichannel high-dose-rate brachytherapy devices confirms their ease of use and dosimetric versatility. However, current clinical guidelines for SAVI and Contura brachytherapy may result in a smaller or less optimal volume of treated tissue compared with traditional interstitial brachytherapy. This study evaluates the feasibility of using the SAVI and Contura to irradiate larger and irregularly shaped target volumes, approaching what is treatable with the interstitial technique. To investigate whether additional tissue can be treated, 17 patients treated with the SAVI and 3 with the Contura were selected. For each patient, the planning target volume (PTV) was modified to extend 1.1 cm, 1.3 cm, and 1.5 cm beyond the tumor bed cavity. To evaluate dose conformance to an irregularly shaped target volume, 9 patients treated with the SAVI and 3 with the Contura were selected from the original 20 patients. The following asymmetric PTV margin combinations were assessed for each patient: 1.5/0.3, 1.3/0.3, and 1.1/0.3 cm. For all patients, treatment planning was performed, adopting the National Surgical Adjuvant Breast and Bowel Project guidelines, and dosimetric comparisons were made. The 6-1 and 8-1 SAVI devices can theoretically treat a maximal tissue margin of 1.5 cm and an asymmetric PTV with margins ranging from 0.3 to 1.5 cm. The 10-1 SAVI and Contura can treat a maximal margin of 1.3 cm and 1.1 cm, respectively, and asymmetric PTV with margins ranging from 0.3-1.3 cm. Compared with the Contura, the SAVI demonstrated greater dosimetric flexibility. Risk of developing excessive hot spots increased with the size of the SAVI device. Both the SAVI and Contura appear capable of treating >1.0-cm margins and irregularly shaped PTVs. The 6-1 SAVI device demonstrated the greatest versatility in targeting PTVs approaching what is treatable using the interstitial technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

Custom fabrication of biomass containment devices using 3-D printing enables bacterial growth analyses with complex insoluble substrates

Physiological studies of recalcitrant polysaccharide degradation are challenging for several reasons, one of which is the difficulty in obtaining a reproducibly accurate real-time measurement of bacterial growth using insoluble substrates. Current methods suffer from several problems including (i) high background noise due to the insoluble material interspersed with cells, (ii) high consumable and reagent cost and (iii) significant time delay between sampling and data acquisition. A customizable substrate and cell separation device would provide an option to study bacterial growth using optical density measurements. To test this hypothesis we used 3-D printing to create biomass containment devices that allow interaction between insoluble substrates and microbial cells but do not interfere with spectrophotometer measurements. Evaluation of materials available for 3-D printing indicated that UV-cured acrylic plastic was the best material, being superior to nylon or stainless steel when examined for heat tolerance, reactivity, and ability to be sterilized. Cost analysis of the 3-D printed devices indicated they are a competitive way to quantitate bacterial growth compared to viable cell counting or protein measurements, and experimental conditions were scalable over a 100-fold range. The presence of the devices did not alter growth phenotypes when using either soluble substrates or insoluble substrates. Furthermore, we applied biomass containment to characterize growth of Cellvibrio japonicus on authentic lignocellulose (non-pretreated corn stover), and found physiological evidence that xylan is a significant nutritional source despite an abundance of cellulose present.

3-D printing↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

A disposable bulk-acoustic-wave microalga trapping device for real-time water monitoring

Recently, there has been an increase in the use of algal physiology as a convenient and useful indicator for monitoring of water quality in aquatic ecosystems. However, current methods for monitoring algal physiology are high-cost, power intensive, and have limited sensitivity for practical samples in which algal concentration is low. In order to alleviate these problems, we developed a simple-to-fabricate acoustophoretic particle trapping device that can effectively enrich various types of microalgae such as chlorella and diatoms for real-time monitoring of water quality. This microalgae trap is fabricated by embedding a piezoelectric resonator in a single channel. In comparison to previously reported acoustophoretic particle traps, this device has a simple structure and does not require sheath flows, which makes the device low cost and simple to fabricate and operate. Using Chlorella kessleri and the marine diatom Thalassiosira pseudonana as model algae, we report the microalgae trap has demonstrated notable particle trapping efficiencies between 82 % to 74 % for Chlorella with a through-flow of 0.5 μl/min to 2.7 μl/min and 85 % to 79 % for diatoms with a 0.5 μl/min to 4 μl/min through-flow. The trap has also shown to simultaneously trap Chlorella and diatoms at different heights of the microchannel. This device has high promise for trapping, separating and manipulating microalgae.

47 OTHER INSTRUMENTATION↗

A sui generis whipping-instability-based self-sequencing multi-monodisperse 2D spray from an anisotropic microfluidic liquid jet device

Well-defined aerosols pave the way for versatile basic and applied research. Here, we demonstrate a unique whipping instability that generates from a high-aspect-ratio microfluidic device resulting in a unique steady-state gas-focused whipping jet (WJ) without any need for electrification. This WJ device emanates a multi-monodisperse whipping spray jet with a two-dimensional (2D) profile. We demonstrate this phenomenon based on various fluidic parameters theoretically and experimentally. The 2D WJ’s unique behavior is derived using analytical fluid dynamics to explain jet diameter, whipping regime, and spreading angle. The phenomenon is further characterized experimentally by measuring the angle with respect to the flow rate, the distances between droplets, the droplet shapes, and the reproducibility of these parameters. We also explain the precise fabrication of such inexpensive devices. Lastly, we highlight these devices’ potential use as sample environments in versatile applications ranging from cryoelectron microscopy over mass spectrometry to drug formulation and structural studies at X-ray free-electron lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Even–Odd Layer-Dependent Exchange Bias Effect in MnBi 2 Te 4 Chern Insulator Devices

Magnetic topological materials with coexisting magnetism and nontrivial band structures exhibit many novel quantum phenomena, including the quantum anomalous Hall effect, the axion insulator state, and the Weyl semimetal phase. As a stoichiometric layered antiferromagnetic topological insulator, thin films of MnBi 2 Te 4 show fascinating even–odd layer-dependent physics. Here, in this work, we fabricate a series of thin-flake MnBi 2 Te 4 devices using stencil masks and observe the Chern insulator state at high magnetic fields. Upon magnetic field training, a large exchange bias effect is observed in odd but not in even septuple layer (SL) devices. Through theoretical calculations, we attribute the even–odd layer-dependent exchange bias effect to the contrasting surface and bulk magnetic properties of MnBi 2 Te 4 devices. Our findings reveal the microscopic magnetic configuration of MnBi 2 Te 4 thin flakes and highlight the challenges in replicating the zero magnetic field quantum anomalous Hall effect in odd SL MnBi 2 Te 4 devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Black Phosphorus for Mid-Infrared Optoelectronics: Photophysics, Scalable Processing, and Device Applications

High efficiency mid-infrared (λ = 3-8 μm) light emitters and photodetectors are pivotal for advancing next-generation optoelectronics. However, narrow-bandgap semiconductors face fundamental challenges such as pronounced nonradiative carrier recombination and thermally generated noise, which impede device performance. Recently, two-dimensional layered black phosphorus (BP) and its alloys have attracted substantial interest for mid-infrared device applications, demonstrating superior performance relative to conventional III-V and II-VI semiconductors with similar bandgaps. In this review, we discuss the optical properties of BP, contrasting these with those of covalent compounds. Owing to its inherently self-terminated surface structure and reduced nonradiative recombination, BP exhibits high performance in light emission and photodetection at room temperature. Furthermore, this review highlights recent advances in the large-area processing of BP thin films, paving the way for practical device applications and integration. Finally, we explore ongoing challenges and emerging opportunities in the utilization of BP for functional mid-infrared devices.

Higashitarumizu, Naoki↗

Clean Graphene Electrodes on Organic Thin-Film Devices via Orthogonal Fluorinated Chemistry

Graphene is a promising flexible, highly transparent, and elementally abundant electrode for organic electronics. Typical methods utilized to transfer large-area films of graphene synthesized by chemical vapor deposition on metal catalysts are not compatible with organic thin-films, limiting the integration of graphene into organic optoelectronic devices. This article describes a graphene transfer process onto chemically sensitive organic semiconductor thin-films. The process incorporates an elastomeric stamp with a fluorinated polymer release layer that can be removed, post-transfer, via a fluorinated solvent; neither fluorinated material adversely affects the organic semiconductor materials. We used Raman spectroscopy, atomic force microscopy, and scanning electron microscopy to show that chemical vapor deposition graphene can be successfully transferred without inducing defects in the graphene film. To demonstrate our transfer method’s compatibility with organic semiconductors, we fabricate three classes of organic thin-film devices: graphene field effect transistors without additional cleaning processes, transparent organic light-emitting diodes, and transparent small-molecule organic photovoltaic devices. Furthermore, these experiments demonstrate the potential of hybrid graphene/organic devices in which graphene is deposited directly onto underlying organic thin-film structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗