Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

First inductively coupled plasma-distance-of-flight mass spectrometer: instrument performance with a microchannel plate/phosphor imaging detector

Here we describe the first combination of a Distance-of-Flight Mass Spectrometry (DOFMS) instrument and an inductively coupled plasma (ICP) ion source. DOFMS is a velocity-based MS technique in which ions of a range of mass-to-charge (m/z) values are detected simultaneously along the length of a spatially selective detector. As a relative of time-of-flight (TOF) MS, DOFMS leverages benefits fromboth TOFMS and spatially dispersive MS. The simultaneous detection of groups of m/z values improves dynamic range by spreading ion signal across many detector elements and reduces correlated noise by signal ratioing. To ascertain the performance characteristics of the ICP-DOFMS instrument, we have employed a microchannel-plate/phosphor detection assembly with a scientific CCD to capture images of the phosphor plate. With this simple (and commercially available) detection scheme, elemental detection limits from 2–30 ng L*1 and a linear dynamic range of 5 orders of magnitude (10–106 ng L1) have been demonstrated. Additionally, a competitive isotope-ratio precision of 0.1% RSD has been achieved with only a 6 s signal integration period. In addition to first figures of merit, this paper outlines technical considerations for the design of the ICP-DOFMS.

Gundlach-Graham, Alexander W.↗

Design, fabrication and test of a pneumatically controlled, renewable, microfluidic bead trapping device for sequential injection analysis applications

This paper describes the design, fabrication, and testing of a pneumatically controlled,renewable, microfluidic device for conducting bead-based assays in an automated sequential injection analysis system. The device used a “brick wall”-like pillar array (pillar size: 20 μm length X 50 μm width X 45 μm height) with 5 μm gaps between the pillars serving as the micro filter. The flow channel where bead trapping occurred is 500 μm wide X 75 μm deep. An elastomeric membrane and an air chamber were located underneath the flow channel. By applying pressure to the air chamber, the membrane is deformed and pushed upward against the filter structure. This effectively traps beads larger than 5 μm and creates a “bed” or micro column of beads that can be perfused and washed with liquid samples and reagents. Upon completion of the assay process, the pressure is released and the beads are flushed out from underneath the filter structure to renew the device. Mouse IgG was used as a model analyte to test the feasibility of using the proposed device for immunoassay applications. Resulting microbeads from an on-chip fluorescent immunoassay were individually examined using flow cytometry. The results show that the fluorescence signal intensity distribution is fairly narrow indicating high chemical reaction uniformity among the beads population. Electrochemical onchip assay was also conducted. A detection limit of 0.1 ng/mL1 ppb was achieved and good device reliability and repeatability were demonstrated. The novel microfluidic-based beadstrapping device thus opens up a new pathway to design micro-bead based biosensor immunoassays for clinical and othervarious applications.

beads trapping↗

Multi-modal, ultrasensitive, wide-range humidity sensing with Ti 3 C 2 film

Gravimetric, direct-current electrical, and electrical impedance sensing modes were used to measure response of high surface area 2D Ti 3 C 2 MXene film to water vapor pressures spanning 3 orders of magnitude (20 mTorr–20 Torr). The Ti 3 C 2 film exhibited reproducible reversible response in 0.1%–95% relative humidity (RH) range with a detection limit of <20 mTorr H 2 O partial pressure (<0.1% RH). DC electrical current-based sensing with 3 mV operating voltage and 0.8 pW power consumption was demonstrated. The highest normalized sensitivity was shown for gravimetric sensing modalities which scale with the overtone number, reaching highest sensitivity of about 12 Hz/% RH at the 9th crystal overtone (45 MHz oscillation).

36 MATERIALS SCIENCE↗

Determination of excited state molecular structures from time-resolved gas-phase X-ray scattering

We present a comprehensive investigation of a recently introduced method to determine transient structures of molecules in excited electronic states with sub-ångstrom resolution from time-resolved gas-phase scattering signals. The method, which is examined using time-resolved X-ray scattering data measured on the molecule N-methylmorpholine (NMM) at the Linac Coherent Light Source (LCLS), compares the experimentally measured scattering patterns against the simulated patterns corresponding to a large pool of molecular structures to determine the full set of structural parameters. In addition, we examine the influence of vibrational state distributions and find the effect negligible within the current experimental detection limits, despite that the molecules have a comparatively high internal vibrational energy. Here, the excited state structures determined using three structure pools generated using three different computational methods are in good agreement, demonstrating that the procedure is largely independent of the computational chemistry method employed as long as the pool is sufficiently expansive in the vicinity of the sought structure and dense enough to yield good matches to the experimental patterns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Robust fluorescent calcium coordination polymers as Cu 2+ sensors with high sensitivity and fast response

A three-dimensional (3D) and highly fluorescent calcium-based coordination polymer (Ca-CP) has been synthesized and structurally characterized. Furthermore, built on a strongly fluorescent (FL) chromophore ligand, [Ca(H 2 tcbpe)(H 2 O) 2 ] (1) (H 4 tcbpe = 4',4''',4''''',4'''''''-(ethene-1,1,2,2-tetrayl)tetrakis(([1,1'-biphenyl]-4-carboxylic acid))) is highly luminescent. Photoluminescence (PL) studies indicate that 1 undergoes a bathochromic shift in emission energy from blue to green color upon outgassing or under mechanic force. Notably, 1 exhibits selective FL sensing for Cu 2+ ions with a detection limit (LOD) of 0.064 ppm, far below the U.S. WHO and EPA standard for drinking water. Detailed investigation of the sensing mechanism reveals that uncoordinated COO– groups in 1 play a major role in recognizing Cu 2+ ions.

36 MATERIALS SCIENCE↗

Single atoms and small clusters of atoms may accompany Au and Pd dendrimer-encapsulated nanoparticles

Here we report the presence of small clusters of atoms (<1 nm) (SCs) and single atoms (SAs) in solutions containing 1–2 nm dendrimer-encapsulated nanoparticles (DENs). Au and Pd DENs were imaged using aberration-corrected scanning transmission electron microscopy (ac-STEM), and energy dispersive spectroscopy (EDS) was used to identify and quantify the SAs/SCs. Two main findings have emerged from this work. First, the presence or absence of SAs/SCs depends on both the terminal functional group of the dendrimer (–NH 2 or –OH) and the elemental composition of the DENs (Au or Pd). Second, dialysis can be used to remove the majority of SAs/SCs in cases where a high density of SAs/SCs are present. The foregoing conclusions provide insights into the mechanisms for Au and Pd DEN synthesis and stability. Ultimately, these results demonstrate the need for careful characterization of systems containing nanoparticles to ensure that SAs/SCs, which may be below the detection limit of most analytical methods, are taken into consideration (especially for catalysis experiments).

74 ATOMIC AND MOLECULAR PHYSICS↗

High Carrier Lifetimes in Epitaxial Germanium-Tin/Al(In)As Heterostructures with Variable Tin Compositions

Group IV-based germanium-tin (Ge1-ySny) compositional materials have recently shown great promise for infrared detection, light emission and ultra-low power transistors. High carrier lifetimes are desirable for enhancing the detection limit and efficiency of photodetectors, low threshold current density in lasers, and low tunneling barrier height by lowering defects and dislocations at the heterointerface of a source and a channel. Here, carrier lifetimes in epitaxial germanium (Ge) and variable tin (Sn) compositional Ge1-ySny materials were experimentally determined on GaAs substrates using the contactless microwave photoconductive decay (u-PCD) technique at an excitation wavelength of 1500 nm. Sharp (2 x 2) reflection high energy electron diffraction patterns and low surface roughness were observed from the surface of the Ge0.97Sn0.03 epilayer. X-ray rocking curves from Ge0.97Sn0.03 and Ge0.94Sn0.06 layers demonstrated the pseudomorphic and lattice-matched growth on AlAs and In0.12Al0.88As buffers, respectively, further substantiated by reciprocal space maps and abrupt heterointerfaces evident from the presence of Pendellosung oscillations. High effective carrier lifetimes of 150 ns to 450 ns were measured for Ge1-ySny epilayers as a function of Sn composition, surface roughness, growth temperature, and layer thickness. The observed increase in the carrier lifetime with an increasing Ge layer thickness and a reducing surface roughness, by incorporating Sn, were explained. The enhancement of the carrier lifetime with an increasing Sn concentration was achieved by controlling the defects with lattice-matched Ge0.94Sn0.06/In0.12Al0.88As heterointerfaces or the pseudomorphic growth of Ge0.94Sn0.06 on GaAs. Therefore, our monolithic integration of variable Sn alloy compositional Ge1-ySny materials with high carrier lifetimes opens avenues to realize electronic and optoelectronic devices.

carrier lifetimes↗

A portable fiber optic sensor for the luminescent sensing of cobalt ions using carbon dots

Cobalt is critical to energy-relevant technologies, and demand for cobalt will increase significantly with growing global adoption of renewables. However, supply chain stability is threatened by economic and geopolitical factors, incentivizing domestic cobalt production from alternative resources such as coal, coal utilization byproducts (e.g., ash, acid mine drainage) and electronic waste. Rapid, inexpensive, and portable characterization techniques are needed to reduce production costs associated with cobalt prospecting and process monitoring. Here, in this research, we develop a compact, portable fiber optic luminescent probe for cobalt using phosphorus and nitrogen co-doped carbon dots as the sensing material. The carbon dot emission overlaps well with the cobalt absorption band at ~510 nm, leading to a selective decrease in emission as a function of cobalt concentration. The system responds nearly instantly to the presence of cobalt, with detection limits of 0.7 and 3.5 ppm in water and pH 1.68 buffer, respectively, providing comparable performance to a commercial spectrometer at a significantly lower cost. Moreover, the sensor is selective for cobalt in the presence of 13 of the most common metal ions encountered in coal utilization byproducts and is responsive to cobalt when spiked into an acid mine drainage leachate sample, highlighting the sensor's potential for real-world deployment in challenging matrices. In addition, integrating the carbon dots with a filter paper substrate produced ‘test strip’ sensors that exhibited a selective and sensitive visual response to cobalt using a handheld UV lamp. Taken together, the sensing system represents a significant step forward in the development of low-cost practical sensors for high-value metals in complex streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cycloalkane-rich sustainable aviation fuel production via hydrotreating lignocellulosic biomass-derived catalytic fast pyrolysis oils

Sustainable aviation fuel (SAF) produced from lignocellulosic biomass is emerging as an ideal alternative to conventional jet fuel for aviation sector decarbonization. Catalytic fast pyrolysis (CFP) can convert lignocellulosic biomass into relatively stable bio-oil that can be selectively transformed to various transportation fuels through hydroprocessing under conditions of different severities. In this contribution, two CFP oils produced from pine-based feedstocks over different types of catalysts (i.e., ZSM-5 and Pt/TiO 2 catalysts) were hydrotreated at 125 bar in a non-isothermal process with a maximum temperature of 385 °C over a sulfided NiMo/Al 2 O 3 catalyst to produce SAF with high cycloalkane concentrations of 89–92 wt%. Cycloalkanes are an important component of jet fuel with advantageous fuel properties, such as high energy density, low sooting, and potential for replacing aromatic hydrocarbons to provide good seal swelling properties. The hydrotreating process successfully converted 91–92% of the biogenic carbon in the CFP oil intermediates to liquid-phase hydrotreated products. Through distillation, 39–40 wt% of the hydrotreated oils were collected in the jet-fuel range as SAF fractions. The rest of the hydrotreated product could be valorized as fuels (e.g., diesel) or chemicals. The SAF fractions with oxygen contents below the detection limit (<0.01 wt%) met ASTM D7566 finished fuel blend and D4054 Tier 1 specifications with respect to density, lower heating value (LHV), volatility, flash point, and freeze point. These results indicate hydrotreating lignocellulosic biomass-derived CFP oil as a promising pathway to produce high-quality SAF rich in cycloalkanes. Continued research is required to increase the SAF yield by process improvements, such as increased CFP oil yields, and an enhanced production of SAF-range molecules via e.g., cracking of high-molecular weight compounds either during CFP or hydrotreating, as well as evaluation of a broader range of jet fuel properties and performance requirements.

09 BIOMASS FUELS↗

Euclid preparation: IV. Impact of undetected galaxies on weak-lensing shear measurements

In modern weak-lensing surveys, the common approach to correct for residual systematic biases in the shear is to calibrate shape measurement algorithms using simulations. These simulations must fully capture the complexity of the observations to avoid introducing any additional bias. In this paper we study the importance of faint galaxies below the observational detection limit of a survey. We simulate simplified Euclid VIS images including and excluding this faint population, and measure the shift in the multiplicative shear bias between the two sets of simulations. We measure the shear with three different algorithms: a moment-based approach, model fitting, and machine learning. We find that for all methods, a spatially uniform random distribution of faint galaxies introduces a shear multiplicative bias of the order of a few times 10 -3 . This value increases to the order of 10 -2 when including the clustering of the faint galaxies, as measured in the Hubble Space Telescope Ultra-Deep Field. The magnification of the faint background galaxies due to the brighter galaxies along the line of sight is found to have a negligible impact on the multiplicative bias. We conclude that the undetected galaxies must be included in the calibration simulations with proper clustering properties down to magnitude 28 in order to reach a residual uncertainty on the multiplicative shear bias calibration of a few times 10 -4 , in line with the 2 × 10 -3 total accuracy budget required by the scientific objectives of the Euclid survey. We propose two complementary methods for including faint galaxy clustering in the calibration simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Decoding NGC 7252 as a blue elliptical galaxy

Elliptical galaxies with blue optical colours and significant star formation are hypothesised to be major merger remnants of gas-rich spiral galaxies or normal elliptical galaxies with a sudden burst of star formation. We present here a scenario in which blue elliptical galaxies identified in shallow imaging surveys may fail to recover faint features that are indicative of past merger activity using a nearby major merger remnant. Based on deep optical imaging data of the post-merger galaxy, NGC 7252, we demonstrate that the galaxy can appear as an elliptical galaxy if it is observed at higher redshifts. The main body and the low surface brightness merger features found at the outskirts of the galaxy are blue in the optical g – r colour map. We argue that the higher-redshift blue elliptical galaxies discovered in surveys as shallow as the SDSS or DECaLS may be advanced mergers whose defining tidal features fall below the detection limits of the surveys. This should be taken into consideration during the morphological classification of these systems in future and ongoing surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray Spectroscopy for Quality Control of Chemotherapy Drugs

We develop a method, employing Compton peak standardization and the use of matrix-matched spiked samples with Total Reflection X-ray Fluorescence (TXRF), for the determination of platinum plasma concentrations of patients undergoing chemotherapy with Pt-bearing drugs. Direct blood plasma analysis attains Pt detection limits of 70 ng/ml. Measurement results of prescribed drug doses are compared to achieved blood Pt concentrations indicating a lack of expected correlations. Direct analysis of Pt-containing infused drugs from a variety of suppliers indicates cases of abnormal concentrations which raises quality control issues. We demonstrate the potential usefulness of the method for pharmacokinetic studies or for routine optimization and quality control of Pt chemotherapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Broadband and time-resolved absorption spectroscopy with light emitting diodes: Application to etching plasma monitoring

Broad band absorption spectroscopy is widely used to measure the concentration of radicals, which is important to understand the physical chemistry of many plasmas. It is possible to increase the sensitivity of this technique and to perform time-resolved measurement by using light emitting diodes (LEDs) as a light source. The method is applied to detect CF{sub 2} radicals and Cl{sub 2} molecules in high density plasmas. The detection limit over 10 ms integration time is as low as 3 mTorr of Cl{sub 2}. We conclude that the absorption spectroscopy with LEDs opens possibilities for precise process control and fundamental analysis of reactive media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase control of iridium and iridium oxide thin films in atomic layer deposition

The atomic layer deposition of iridium (Ir) and iridium oxide (IrO{sub 2}) films was investigated using an alternating supply of (ethylcyclopentadienyl)(1,5-cyclooctadiene) iridium and oxygen gas at temperatures between 230 and 290 deg. C. The phase transition between Ir and IrO{sub 2} occurred at the critical oxygen partial pressure during the oxygen injection pulse. The oxygen partial pressure was controlled by the O{sub 2}/(Ar+O{sub 2}) ratio or deposition pressures. The resistivity of the deposited Ir and IrO{sub 2} films was about 9 and 120 {mu}{omega} cm, respectively. In addition, the critical oxygen partial pressure for the phase transition between Ir and IrO{sub 2} was increased with increasing the deposition temperature. Thus, the phase of the deposited film, either Ir or IrO{sub 2}, was controlled by the oxygen partial pressure and the deposition temperature. However, the formation of a thin Ir layer was detected between the IrO{sub 2} and SiO{sub 2} substrate. To remove this interfacial layer, the oxygen partial pressure is increased to a severe condition. And the impurity contents were below the detection limit of Auger electron spectroscopy in both Ir and IrO{sub 2} films.

36 MATERIALS SCIENCE↗

Ga kinetics in plasma-assisted molecular-beam epitaxy of GaN(1122): Effect on the structural and optical properties

GaN directly deposited on m-sapphire by plasma-assisted molecular-beam epitaxy settles into two main crystalline orientation domains: GaN(1122) and GaN(1013). The dominant phase is GaN(1122) with <1123>{sub GaN} parallel <0001>{sub sapphire} and <1100>{sub GaN} parallel <1120>{sub sapphire} in-plane epitaxial relationships. Deposition of GaN on top of an AlN(1122) buffer layer and growth under slightly Ga-rich conditions reduce GaN(1013) precipitates below the detection limits. Studies of Ga adsorption demonstrate that it is possible to stabilize up to one Ga monolayer on the GaN(1122) surface. The presence of this monolayer of Ga excess on the growth front reduces the (1122) surface energy and hence minimizes the surface roughness. Photoluminescence from two-dimensional GaN(1122) layers is dominated by a near-band-edge emission, which is assigned to excitons bound to stacking faults, present with a density around 3x10{sup 5} cm{sup -1}.

36 MATERIALS SCIENCE↗