Search NASA⌕ Search

SEARCH · Search NASA

Results for “Device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

In‐Silico Device Performance Prediction of Cosensitizer Dye Pairs for Dye‐Sensitized Solar Cells

Abstract Endeavors in the field of dye‐sensitized solar cells (DSCs) have shown great promise when adopting a data‐driven approach to materials discovery, such as successful molecular‐scale predictions of light‐harvesting chromophores. However, predictions of DSC dyes would become much more sophisticated if a molecular‐to‐macroscopic DSC device prediction methodology existed. Thereby, a fully computational pipeline is presented that predicts device‐performance parameters of DSCs which contain varying dye combinations. Optimal pairing of complementary dyes is identified via a data‐driven workflow that affords cosensitized DSCs with maximum power‐conversion efficiencies. Six high‐performing DSC dyes are paired with partner dyes that are screened from a database of 8488 compounds using sequential heuristic filters. Existing models that predict short‐circuit‐current density ( J SC ) and open‐circuit voltage ( V OC ) parameters are adapted to predict singly sensitized and cosensitized DSC performance. The predictions for J sc values of singly sensitized devices match experimental literature values with comparable accuracy to more computationally costly methods. Five out of six dye pairings are predicted to have greater J SC values when cosensitized compared to their corresponding singly sensitized devices, including two pairs that show strong J sc boosts of +13% and +12% when cosensitized. Thus, the prospect of an entirely in‐silico prediction pipeline for DSC performance that can be used to realize the fully automated design of optimized cosensitized DSCs is demonstrated.

14 SOLAR ENERGY↗

Efficient Solar‐Thermal Distillation Desalination Device by Light Absorptive Carbon Composite Porous Foam

Abstract Solar‐thermal driven desalination based on porous carbon materials has promise for fresh water production. Exploration of high‐efficiency solar desalination devices has not solved issues for practical application, namely complicated fabrication, cost‐effectiveness, and scalability. Here, direct solar‐thermal carbon distillation (DS‐CD) tubular devices are introduced that have a facile fabrication process, are scalable, and use an inexpensive but efficient microporous graphite foam coated with carbon nanoparticle and superhydrophobic materials. The “black” composite foam serving as a solar light absorber heats up salt water effectively to produce fresh water vapor, and the superhydrophobic surface of the foam traps the liquid feed in the device. Two proof‐of‐principle distillation systems are adopted, i.e., solar still and membrane distillation and the fabricated devices are evaluated for direct solar desalination efficiency. For the solar still, nanoparticle and fluorosilane coatings on the porous surface increase the solar energy absorbance, resulting in a solar‐steam generation efficiency of 64% from simulated seawater at 1 sun. The membrane distillation demonstrates excellent vapor production (≈6.6 kg m ‐2 h ‐1 ) with >99.5% salt rejection under simulated 3 sun solar‐thermal irradiation. Unlike traditional solar desalination, the adaptable DS‐CD can easily be scaled up to larger systems such as high‐temperature tubular modules, presenting a promising solution for solar‐energy‐driven desalination.

42 ENGINEERING↗

Characterization of crosstalk in stereoscopic display devices

Many different types of stereoscopic display devices are used for commercial and research applications. Stereoscopic displays offer the potential to improve performance in detection tasks for medical imaging diagnostic systems. Due to the variety of stereoscopic display technologies, it remains unclear how these compare with each other for detection and estimation tasks. Different stereo device shave different performance trade-offs due to their display characteristics. Among them, crosstalk is known to affect observer perception of 3D content and might affect detection performance. We measured and report the detailed luminance output and crosstalk characteristics for three different types of stereoscopic display devices. We recorded the effect of other issues on recorded luminance profiles such as viewing angle, use of different eye wear, and screen location. Our results show that the crosstalk signature for viewing 3D content can vary considerably when using different types of 3D glasses for active stereo dis-plays. We also show that significant differences are present in crosstalk signatures when varying the viewing angle from 0 degrees to 20 degrees for a stereo mirror 3D display device. Our detailed characterization can help emulate the effect of crosstalk in conducting computational observer image quality assessment evaluations that minimize costly and time-consuming human reader studies.

42 ENGINEERING↗

Device physics underlying silicon heterojunction and passivating‐contact solar cells: A topical review

Abstract The device physics of commercially dominant diffused‐junction silicon solar cells is well understood, allowing sophisticated optimization of this class of devices. Recently, so‐called passivating‐contact solar cell technologies have become prominent, with Kaneka setting the world's silicon solar cell efficiency record of 26.63% using silicon heterojunction contacts in an interdigitated configuration. Although passivating‐contact solar cells are remarkably efficient, their underlying device physics is not yet completely understood, not in the least because they are constructed from diverse materials that may introduce electronic barriers in the current flow. To bridge this gap in understanding, we explore the device physics of passivating contact silicon heterojunction (SHJ) solar cells. Here, we identify the key properties of heterojunctions that affect cell efficiency, analyze the dependence of key heterojunction properties on carrier transport under light and dark conditions, provide a self‐consistent multiprobe approach to extract heterojunction parameters using several characterization techniques (including dark J‐V, light J‐V, C‐V, admittance spectroscopy, and Suns‐V oc ), propose design guidelines to address bottlenecks in energy production in SHJ cells, and develop a process‐to‐module modeling framework to establish the module's performance limits. We expect that our proposed guidelines resulting from this multiscale and self‐consistent framework will improve the performance of future SHJ cells as well as other passivating contact‐based solar cells.

Chavali, Raghu V. K.↗

Mapping Conductance and Switching Behavior of Graphene Devices In Situ

Graphene is proposed for use in various nanodevice designs, many of which harness emergent quantum properties for device functionality. However, visualization, measurement, and manipulation become nontrivial at nanometer and atomic scales, representing a significant challenge for device fabrication, characterization, and optimization at length scales where quantum effects emerge. Herein, proof of principle results at the crossroads between 2D nanoelectronic devices, e-beam-induced modulation, and imaging with secondary electron e-beam induced currents (SEEBIC) is presented. A device platform compatible with scanning transmission electron microscopy investigations is introduced. Then how the SEEBIC imaging technique can be used to visualize conductance and connectivity in single layer graphene nanodevices, even while supported on a thicker substrate (conditions under which conventional imaging fails) is shown. Finally, it is shown that the SEEBIC imaging technique can detect subtle differences in charge transport through time in nonohmic graphene nanoconstrictions indicating the potential to reveal dynamic electronic processes.

36 MATERIALS SCIENCE↗

A New Hole Transport Material for Efficient Perovskite Solar Cells With Reduced Device Cost

To realize commercialization of perovskie solar cell (PVSC) technology, it is essential to reduce the device costs while maintaining high power conversion efficiencies (PCEs). So far, the high cost of the most commonly used hole selective material, 2,2′,7,7′‐Tetrakis (N,N‐di‐p‐methoxyphenylamino)‐9,9′‐spirobifluorene (spiro‐OMeTAD), for high‐PCE PVSCs presents a significant obstacle for device cost reduction. In this work, the synthesis and characterization of a new spiro‐OMeTAD derivative hole selective material, 2,6,14‐tris(5′‐(N,N‐bis(4‐methoxyphenyl)aminophenol‐4‐yl)‐3,4‐ethylenedioxythiophen‐2‐yl)‐triptycene (TET) is reported. TET features a three‐dimensional structure consisting of a triptycene core and triarylamine arms linked by 3,4‐ethylenedioxythiophene, facilitating efficient hole transport. Planar PVSCs using TET hole selective layers (HSLs) achieved high fill factors of over 81% and steady‐state efficiencies of up to 18.6%, comparable with that (19.0%) of PVSC using spiro‐OMeTAD HSL. Importantly, the hereby reported efficient PVSCs can be produced with very thin TET HSLs (about 30 nm). Considering the lower laboratory synthesis and purification cost ($123 vs. $500 g −1 ) and thinner HSL (30 vs. 200 nm), the cost for TET on a unit area of one device is 25 times lower than that for high‐purity spiro‐OMeTAD. The device with TET HSL shows good stability under continuous illumination. Therefore, this work makes a significant step forward toward the commercialization of the emerging PVSC technology.

Sun, Yuhao↗

Understanding the Role of CdTe in Polycrystalline CdSe x Te 1– x /CdTe-Graded Bilayer Photovoltaic Devices

Grading of bandgap by alloying CdTe with selenium to form a CdSe x Te 1–x /CdTe-graded bilayer device has led to a device efficiency over 19%. A CdSe x Te 1–x absorber would increase the short-circuit current due to its lower bandgap but at the expense of open-circuit voltage. It has been demonstrated that adding a CdTe layer at the back of such a CdSe x Te 1–x film reduces the voltage deficit caused by the lower bandgap of absorber from selenium alloying while maintaining the higher short-circuit current. This leads to a photovoltaic device that draws advantage from both materials with an efficiency greater than either of them. In this report there is a detailed account using device data, ultraviolet photoelectron spectroscopy, electron microscopy, and first-principles density functional theory modeling is provided, which shows that CdTe acts as an electron reflector for CdSe x Te 1–x .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Amplatzer Vascular Plug: A Review of the Device and its Clinical Applications

The Amplatzer Vascular Plug (AVP) is an established embolic device that can be an excellent alternative to coils or detachable balloons to embolize medium to large vessels with high flow. The device is easy to use and can be precisely deployed in the target vessel with high resistance to migration and a low recanalization rate. The technical success of this device is high, indications for use are expanding, and no absolute contraindications have been reported. Since its introduction, the AVP has grown from a single device to a group of 4 models (AVP, AVP II, AVP III, and AVP 4). Each model has a unique design and features that fit different vascular anatomies, hemodynamic situations, and clinical scenarios. Therefore, the new models cannot simply be treated as replacements for older ones. Unpredictable occlusion time remains a major shortcoming for the new models of the AVP. Large vessel size, high flow status, and coagulopathy can prolong the occlusion time, which can offset the cost benefit, reduced procedure time, and reduced radiation dose typically seen with use of the AVP alone. Coils or multiple AVPs can be used to expedite the occlusion process, and large Gelfoam particles also can be used as an adjunct to achieve rapid and reliable occlusion with minimal cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of a Novel Vascular Closure Device (Glubran 2 Seal) After Diagnostic and Interventional Angiography in Patients with Peripheral Arterial Occlusive Disease

To prospectively evaluate safety and efficacy of a novel vascular closure device (Glubran 2 Seal) after peripheral angiography in patients with peripheral arterial occlusive disease (PAOD). From December 2010 to June 2011, all consecutive patients with PAOD undergoing peripheral angiography were prospectively enrolled onto the study after percutaneous antegrade or retrograde puncture of the common femoral artery. After angiography, the Glubran 2 Seal device was used to achieve hemostasis. The following data were registered: technical success and manual compression duration, patients' discomfort (scale 0-5), operators' technical difficulty (scale 0-5), and vascular complications. The site of hemostasis was evaluated by clinical inspection and color-coded Duplex ultrasound performed 1 day and 1 month after the procedure. One hundred seventy-eight patients were enrolled (112 male, mean age 70.8 years) with a total of 206 puncture sites, including 104 (50.5 %) antegrade accesses. The device was successful in 198(96.1 %) of 206 procedures, with 8 cases of manual compression lasting longer than 5 min (maximum 20 min). No major vascular complications were observed, resulting in 100 % procedural success. Minor complications occurred in seven procedures (3.4 %), including two cases of pseudoaneurysms, successfully treated by ultrasound-guided glue injection. The mean {+-} standard deviation score for patients' discomfort was 0.9 {+-} 0.7, whereas the mean score for operators' difficulty was 1.2 {+-} 0.9. In patients with PAOD, the Glubran 2 Seal represents a simple, painless, and efficient vascular closure device, able to achieve hemostasis both in antegrade and retrograde accesses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transseptal Guidewire Stabilization for Device Closure of a Large Pulmonary Arteriovenous Malformation

A 46-year-old man presenting with massive hemoptysis was found to have a large pulmonary arteriovenous malformation (PAVM) in the right lung. Closure of the PAVM with an Amplatzer-type duct occluder was hampered by inability to advance the device delivery sheath into the PAVM due to vessel tortuosity and inadequate guidewire support. Atrial septal puncture was performed and a femorofemoral arteriovenous guidewire loop through the right pulmonary artery, PAVM, and left atrium was created. Traction on both ends of the guidewire loop allowed advancement of the device delivery sheath into the PAVM and successful completion of the procedure. Transseptal guidewire stabilization can be a valuable option during device closure of large PAVMs when advancement, stability, or kinking of the device delivery sheath is an issue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enabling Real-Time Volume Rendering of Functional Magnetic Resonance Imaging on an iOS Device

Powerful non-invasive imaging technologies like computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI) are used daily by medical professionals to diagnose and treat patients. While 2D slice viewers have long been the standard, many tools allowing 3D representations of digital medical data are now available. The newest imaging advancement, functional MRI (fMRI) technology, has changed medical imaging from viewing static to dynamic physiology (4D) over time, particularly to study brain activity. Add this to the rapid adoption of mobile devices for everyday work and the need to visualize fMRI data on tablets or smartphones arises. However, there are few mobile tools available to visualize 3D MRI data, let alone 4D fMRI data. Building volume rendering tools on mobile devices to visualize 3D and 4D medical data is challenging given the limited computational power of the devices. This paper describes research that explored the feasibility of performing real-time 3D and 4D volume raycasting on a tablet device. The prototype application was tested on a 9.7” iPad Pro using two different fMRI datasets of brain activity. The results show that mobile raycasting is able to achieve between 20 and 40 frames per second for traditional 3D datasets, depending on the sampling interval, and up to 9 frames per second for 4D data. While the prototype application did not always achieve true real-time interaction, these results clearly demonstrated that visualizing 3D and 4D digital medical data is feasible with a properly constructed software framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Next-Generation Hard X-Ray Nanoprobe Beamline for In Situ Studies of Energy Materials and Devices

The Advanced Photon Source is developing a suite of new X-ray beamlines to study materials and devices across many length scales and under real conditions. One of the flagship beamlines of the APS upgrade is the In Situ Nanoprobe (ISN) beamline, which will provide in situ and operando characterization of advanced energy materials and devices under varying temperatures, gas ambients, and applied fields, at previously unavailable spatial resolution and throughput. Examples of materials systems include inorganic and organic photovoltaic systems, advanced battery systems, fuel cell components, nanoelectronic devices, advanced building materials and other scientifically and technologically relevant systems. To characterize these systems at very high spatial resolution and trace sensitivity, the ISN will use both nanofocusing mirrors and diffractive optics to achieve spots sizes as small as 20 nm. Nanofocusing mirrors in Kirkpatrick–Baez geometry will provide several orders of magnitude increase in photon flux at a spatial resolution of 50 nm. Diffractive optics such as zone plates and/or multilayer Laue lenses will provide a highest spatial resolution of 20 nm. Coherent diffraction methods will be used to study even small specimen features with sub-10 nm relevant length scale. A high-throughput data acquisition system will be employed to significantly increase operations efficiency and usability of the instrument. The ISN will provide full spectroscopy capabilities to study the chemical state of most materials in the periodic table, and enable X-ray fluorescence tomography. In situ electrical characterization will enable operando studies of energy and electronic devices such as photovoltaic systems and batteries. We also describe the optical concept for the ISN beamline, the technical design, and the approach for enabling a broad variety of in situ studies. Furthermore, we discuss the application of hard X-ray microscopy to study defects in multi-crystalline solar cells, one of the lines of inquiries for which the ISN is being developed.

42 ENGINEERING↗

Millimeter-scale gate-tunable graphene nanoribbon devices as a platform for mid-infrared and bio sensing applications

The experimental observation of graphene plasmon resonance has generated tremendous interest due to numerous potential applications such as photosensors, detectors, biosensors, and switches from THz to mid-infrared regime. However, practical applications require much larger dimensions (mm to cm scale) than that demonstrated in the proof-of-concept devices. Moreover, such devices also require a detailed understanding of ribbon-to-ribbon interaction, which has not been investigated so far. Here in this paper we demonstrate gate tunable plasmon resonance in the mid-infrared spectral region on millimeter-scale graphene nanoribbon (GNR) array devices fabricated using graphene monolayer. Gate dependent Fourier-transform infrared (FTIR) transmission measurements on GNR of various widths were investigated experimentally. The shift in plasmon resonance peaks of wave number 100 cm -1 at applied external gate voltage -100 V was observed. This shift is attributed to strong gate modulation. Our investigation of ribbon-to-ribbon interaction by tuning the aspect ratio reveals strong modulation of surface plasmon resonance peaks in GNR. This suggests that plasmon resonances are coupled as evidenced by blue-shifted plasmon resonance. These studies demonstrate that large-area GNR devices can serve as an ideal platform for ultrasensitive sensing and detector applications.

36 MATERIALS SCIENCE↗

Industrial control system device classification using network traffic features and neural network embeddings

Characterization of modern cyber–physical Industrial Control System (ICS) devices is critical to the evaluation of their security posture and an understanding of the underlying industrial processes with which they interact. In this work, we address two related ICS device identification tasks: (1) separating ICS from non-ICS devices and (2) identifying specific ICS device types. We propose two distinct methods (one based on the existing IP2Vec method, and a novel traffic-features-based method) for achieving the first task. For transferability of the first task between two datasets, the traffic-features-based method performs significantly better (75% overall accuracy) compared to IP2Vec (22.5% overall accuracy). We further propose a novel method called DNP2Vec to address the second task. DNP2Vec is evaluated on two different datasets and achieves perfect multi-class classification accuracy (100%) for both datasets.

42 ENGINEERING↗

A monolayer microfluidic device supporting mouse spermatogenesis with improved visibility

In our previous study, we produced a microfluidic device (MFD) which successfully maintained spermatogenesis for over 6 months in mouse testis tissues loaded in the device. In the present study, we developed a new MFD, a monolayer device (ML-D) with a barrier structure consisting of pillars and slits, which is simpler in design and easier to make. This ML-D was also effective for inducing mouse spermatogenesis and maintained it for a longer period than the conventional culture method. In addition, we devised a way of introducing sample tissue into the device during its production, just before bonding the upper layer of polydimethylsiloxane (PDMS) and bottom glass slide. The tissue can obtain nutrients horizontally from the medium running beside it and oxygen vertically from above through PDMS. In addition, the glass slide set at the bottom improved the visibility of the sample tissue with an inverted microscope. When we took photos of cultured tissue of the Acr-Gfp transgenic mouse testis in ML-D sequentially every day, morphological changes of the acrosome during spermiogenesis were successfully recorded. The ML-D is simple in design and useful for culturing testis tissue for inducing and maintaining spermatogenesis with clearer visibility. Due to the new method of sample loading, tissues other than testis should also be applicable.

60 APPLIED LIFE SCIENCES↗

Thermal comfort evaluated for combinations of energy-efficient personal heating and cooling devices

Personal comfort systems (PCS) have potential to fulfill building occupants' personal thermal comfort preferences with great efficiency. But to integrate them into building conditioning, there must be a broader selection of PCS devices available. Design guidance and standards are needed to assure that such devices provide high levels of comfort effectiveness and energy efficiency. This study addresses these needs. A suite of minimum-power PCS devices was built that target body parts significant to alliesthesia—a heated shoe insole, heated/cooled wristpad, small deskfan, and heated/cooled chair. They were tested in a climate chamber under cool and warm conditions using both thermal-manikin and human-subjects. Their efficiency at physically heating/cooling the body is high; the combined suite has a coefficient of performance (COP) of 3.6 for cooling and 0.88 for heating. The subjects' whole-body thermal acceptance and thermal comfort perception were improved by the devices in an additive manner; using the combined suite over 80% of people accepted ambient temperatures of 18°C and 29°C. The PCS ‘corrects’ the ambient temperature towards thermal neutrality by as much as 6.5 K cooling and 3.6 K heating, overcoming building occupants' typical interpersonal thermal differences and making possible large HVAC energy savings in buildings. The idea of temperature corrective power can be the basis of standards for PCS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The environmental interactions of tidal and wave energy generation devices

Global energy demand continues to grow and tidal and wave energy generation devices can provide a significant source of renewable energy. Technological developments in offshore engineering and the rising cost of traditional energy means that offshore energy resources will be economic in the next few years. While there is now a growing body of data on the ecological impacts of offshore wind farms, the scientific basis on which to make informed decisions about the environmental effects of other offshore energy developments is lacking. Tidal barrages have the potential to cause significant ecological impacts particularly on bird feeding areas when they are constructed at coastal estuaries or bays. Offshore tidal stream energy and wave energy collectors offer the scope for developments at varying scales. They also have the potential to alter habitats. A diversity of designs exist, including floating, mid-water column and seabed mounted devices, with a variety of moving-part configurations resulting in a unique complex of potential environmental effects for each device type, which are discussed to the extent possible. - Highlights: Black-Right-Pointing-Pointer We review the environmental impacts of tidal barrages and fences, tidal stream farms and wave energy capture devices. Black-Right-Pointing-Pointer Impacts on habitats, species and the water column, and effects of noise and electromagnetic fields are considered. Black-Right-Pointing-Pointer Tidal barrages can cause significant impacts on bird feeding areas when constructed at coastal estuaries or bays. Black-Right-Pointing-Pointer Wave energy collectors can alter water column and sea bed habitats locally and over large distances.

16 TIDAL AND WAVE POWER↗