Flame-Based Synthesis of Core-Shell Structures Using Pd-Ru and Pd Cores
N/A
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
N/A
Here, particle/polymer electrospinning was used to prepare fiber mat cathodes containing LiCoO 2 nanoparticles, carbon powder, and poly(vinylidene fluoride) for Li-ion batteries. The fibers had a high LiCoO 2 particle content (70 wt%) which allowed for a high gravimetric capacity of 90 mAh g -1 (corresponding to 128 mAh g$-1\atop{LiCoO2}$) at 0.1C (1C = 274 mAh g$-1\atop{LiCoO2}$). Cathode performance was stable in a half cell with 78% capacity retention over 200 cycles at 0.5C. Unlike previous work on electrospun LiCoO 2 nanofibers prepared using sol-gel chemistry and high temperature processing, the particle/polymer fiber mat cathodes reported here were made thick with a high fiber volume fraction for high areal and volumetric capacities at fast charge/discharge rates (e.g., 0.81 mAh cm -2 and 62 mAh cm -3 at 2C) which were much greater than that of a slurry cast cathode of the same composition (0.004 mAh cm -2 and 0.30 mAh cm -3 at 2C). Full cells containing a LiCoO 2 /C/PVDF fiber mat cathode and C/PVDF fiber mat anode were also prepared and characterized. These electrospun batteries exhibited a high energy density of 144 Wh kg -1 at 0.1C and an areal capacity of 1.03 mAh cm -2 at 1C. The excellent performance of the electrospun particle/polymer cathodes and anodes is attributed to electrolyte penetration throughout the 3D fiber electrode mats, a large electrode/electrolyte interfacial area, and short Li + transport pathways between the electrolyte and active material nanoparticles in the radial fiber direction.
Not Available
Thin/tunable liquid/gas diffusion layers (TT-LGDLs) or porous transport layers (TT-PTLs), have exhibited superior multifunctional performance in proton exchange membrane electrolyzer cells (PEMECs), which can be attributed to their unique structures, such as planar surface, straight-through pores, thin thickness, etc. For achieving better PEMEC performance, TT-LGDLs with smaller pore size are desired. However, in this case, mass diffusion issues are brought in when some of the pores are covered by the flow field lands or shoulders. The coverage of the pores can lead to very high transport resistance, which may reduce the number of active oxygen evolution reaction sites, and therefore lower down the PEMEC performance. The in-plane transport enhancement layer for TT-LGDLs/PTLs are proposed to develop a dual-layer LGDL/PTL structure for improving the mass diffusion and the PEMEC performance. The results of this research reveal that the dual-layer LGDL/PTL structure exhibits smaller ohmic resistance and mass transport resistance, and therefore improve the PEMEC performance, without obvious changes in kinetic losses. The total ohmic resistance and mass transport resistance can be reduced by about 23% and 41%, respectively, with an ~830 um pore TT-LGDL/PTL stacking on a ~100 um pore TT-LGDL/PTL. The results indicate the feasibility of stacking the in-plane transport enhancement layer with large pore sizes onto a small pore TT-LGDLs/PTLs for high efficiency and low cost PEMEC practical applications.
Water management remains a key challenge in polymer-electrolyte fuel cells. In this paper, a pseudo 3-D (1+2D) model is developed to account better for changes of water management along the channel, as well as verify the possibilities of using differential cells for data capture and translation to integral cell performance. An accurate 2-D membrane-electrode-assembly model is developed for differential cell modeling, which is combined with an along-the-channel stepping algorithm to account for down the channel changes in pressure, temperature, reactant concentration, and relative humidity. Variations in cell performance along the channel due to changes in operating conditions are characterized quantitatively and optimized, where drier feed conditions demonstratively require such an approach. In conclusion, the study identifies gaps between differential and integral cells including those related to flow velocity and highlights the need for better models to understand and link integral cell performance and water management.
In this work, a platinum group metal- free (PGM-free) Fe-N-C oxygen reduction reaction (ORR) catalyst derived from metal organic framework precursors (Fe-MOF) is evaluated at the cathode side of a direct methanol fuel cell (DMFC). A wide range of methanol concentrations were used, and the performance of the DMFC using air was evaluated and compared to a commercial Pt/C cathode. We conducted our tests with a custom, integrated H 2 reference electrode that separately provided the anode and cathode overpotentials. This allowed us to perform a Tafel analysis on both electrodes and understand the dominant polarizations involved at the PGM-free cathode and the PtRu/C anode. Overall, we achieved a high cell performance using a Fe-N-C based catalyst under liquid methanol and air operation with a peak power density of 111 mW/cm 2 , where the cathode presented a markedly larger contribution to the voltage loss versus the anode. Additionally, we used nanoscale X-ray computed tomography (nano-CT) to image the Fe-N-C cathode and investigate the ionomer and pore size distributions allowing us to identify areas of improvement for catalyst layer fabrication.
Here, the most active class of platinum group metal-free (PGM-free) oxygen reduction reaction (ORR) electrocatalysts in acidic electrolytes are those synthesized by heat treatment of iron, carbon, nitrogen precursors (Fe-N-C). Due to the large number of possible precursor compounds, a small fraction of the synthesis variable space has been explored. Correlation of synthesis variables with Fe speciation and ORR activity has been limited. In this work, an automation platform and a multi-port ball-milling were utilized to evaluate the effects of synthesis variables, such as identity of iron precursor, iron loading, and carbon and nitrogen sources on the ORR activity of iron -nitrogen-carbon catalysts in acidic electrolyte. The ORR activity is correlated with catalyst Fe speciation determined using Fe K-edge X-ray absorption spectroscopy (XAFS).
In Li-ion battery research, it is common to simulate chemo-mechanical phenomena in reduced dimensions (e.g., 2-D) as opposed to fully resolve these complex physics in 3-D. It is common to assume either (1) the out-of-plane strain is negligible (commonly referred to as plane-strain), or (2) the out-of-plane stress is negligible (commonly referred to as plane-stress). However, there is typically little consideration as to the quantitative consequences of these approximations. Furthermore, the influence of these out-of-plane assumptions can be compounded and convoluted when chemo-mechanics models implement so-called “fully coupled” formulations, where the local species concentrations influence the stress-state and the stress-state influences the local species fluxes. Here, the present manuscript explores the implications of using plane-stress and plane-strain assumptions in 2-D as compared to simulating a full 3-D electrode particle. This comparative study includes simulating both isotropic and anisotropic particle intercalation where the particles can be surrounded by either a liquid or solid electrolyte. Additionally, common Li-ion battery-model metrics such as the state-of-stress, intercalation fraction distribution, and specific capacity are compared, while also considering the effects of particle size and C-rate. As alternatives to the pure plane-strain and plane stress approximations, two modified plane-strain assumptions are found to better approximate the fully coupled chemo-mechanical 3-D behavior.
Explore the source record for details and available documents.
The surge in interval meter data availability and associated activity in energy data analytics has inspired new interest in advanced methods for building efficiency savings estimation. Statistical and machine learning approaches are being explored to improve the energy baseline models used to measure and verify savings. One outstanding challenge is the ability to identify and account for operational changes that may confound savings estimates. In the measurement and verification (M&V) context, ‘non-routine events’ (NREs) cause changes in building energy use that are not attributable to installed efficiency measures, and not accounted for in the baseline model’s independent variables. In the M&V process NREs must be accounted for as ‘adjustments’ to appropriately attribute the estimated energy savings to the specific efficiency interventions that were implemented. Currently this is a manual and custom process, conducted using professional judgment and engineering expertise. As such it remains a barrier in scaling and standardizing meter-based savings estimation. Here in this work, a data driven methodology was developed to (partially) automate, and therefore streamline the process of detecting NREs in the post-retrofit period and making associated savings adjustments. The proposed NRE detection algorithm is based on a statistical change point detection method and a dissimilarity metric. The dissimilarity metric measures the proximity between the actual time series of the post-retrofit energy consumption and the projected baseline, which is generated using a statistical baseline model. The suggested approach for NRE adjustment involves the NRE detection algorithm, the M&V practitioner, and a regression modeling algorithm. The performance of the detection and adjustment algorithm was evaluated using a simulation-generated test data set, and two benchmark algorithms. Results show a high true positive detection rate (75%-100% across the test cases), higher than ideal false positive detection rates (20%-70%), and low errors in energy adjustment (<0.7%). These results indicate that the algorithm holds for helping M&V practitioners to streamline the process of handling NREs. Moreover, the change point algorithm and underlying statistical principles could prove valuable for other building analytics applications such as anomaly detection and fault diagnostics.
Solar power is considered among the leading renewable energy technologies. Abundant supply, flexibility of installation, and decreasing cost makes it an interesting renewable energy resource. However, there are challenges associated with the reliability of solar power due to its intermittent nature. This work demonstrates the synergies that exist in integrated hybrid systems, where a dispatchable fuel is used in conjunction with concentrated solar power. In this simulation-based study, a parabolic trough solar concentrator is used to collect solar energy. The heat collected from the solar field is used to generate steam in a Rankine cycle. The system also utilizes natural gas combustion in the steam generator to provide supplemental steam when the solar intensity is reduced due to cloud cover or at night. Natural gas is also used for superheating the steam, which allows the system to produce higher temperatures and achieve increased thermodynamic cycle efficiencies. This flexible design produces 100 MW at nominal conditions, while it is capable of producing a maximum of 140 MW when sufficient solar energy is available. The novel contributions of this work include a complete, systems-level, dynamic model of a hybrid solar plant. The model is complete with a control system that smoothly transitions the plant from pure natural gas mode at night to solar hybrid mode during the day. It evaluates innovative design features such as flexible fuel operation, steam superheating to boost efficiency, and preheating by solar or waste heat. Furthermore, this work demonstrates that by hybridizing a solar system with a dispatchable energy source, both the reliability and efficiency of the solar power production are increased. The annual solar-to-electric efficiency increases from 15.2% to 26.13% with hybridization, which indicates that utilization of the solar energy is effectively increased.
With the advancement in sub-ambient cooling of water during daytime under the sun with scalable-manufactured radiative cooling metamaterials, the challenge for applications lies in design and building of large-scale radiative cooling systems. Here, we present a kW-scale, 24-hour continuously operational, radiative sky cooling system, with both experimental study and detailed modeling. We first quantitatively show how water flow rate directly affects the system cooling power and inversely affects the water temperature drop. A day-and-night stagnant (flow rate = 0 L/(min·m 2 )) water cooling test of the system shows a consistent sub-ambient water temperature drop of 5–7 °C. A daytime cooling test of the system at a low flow rate of 0.227 L/(min·m 2 ) yields a maximum sub-ambient temperature drop of 4.0 °C with an average net cooling power of around 80 W/m 2 . Further modelling for a typical metrological year (in Phoenix, Arizona) shows that the system could generate as much as 350 kWh cold (or 26 kWh/m 2 ) with a sub-ambient temperature drop of 4–5 °C at a low flow rate of 0.1 L/(min·m 2 ) during a typical summer month. The cold generated could be used to assist AC systems in regions or seasons with high ambient temperatures.
Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.
Fixed-bed regenerators may be a low cost alternative to recuperators for supercritical CO 2 power cycles. However, the transient nature of regenerators operating in sCO 2 power cycles has not been previously characterized. This study details a one-dimensional, transient model of a fixed-bed regenerator that captures phenomena such as local fluid properties and heat transfer coefficients, entrained fluid heat capacity, and the effects of conservation of mass during process switching. The model is validated with experimental results of a 10 kWth regenerator. This comparison shows that the model predicts temperature as a function of both time and space exceptionally well. The model predicts effectiveness, heat transfer, and discharge temperatures within 5%, and predicts pressure drop and fluid carryover within 10%. This model could be used in future studies to simulate regenerators within a supercritical CO 2 power cycle.
In this study, a novel triple power cycle is proposed where waste heat from a gas turbine cycle is utilized to drive a supercritical carbon dioxide (s-CO 2 ) recompression cycle and a recuperative organic Rankine cycle (ORC) in sequence. A detailed thermoeconomic model is developed and implemented in MATLAB to evaluate the performance of the proposed cycle under different operating conditions. Optimization using a particle swarm optimization (PSO) algorithm is performed to minimize the levelized cost of electricity (LCOE) and determine the optimum design conditions of the cycle. The optimization results show that for a 100 MW cycle, the overall thermal efficiency and LCOE are 0.521 and $\$52.819$/MWh, respectively. The turbine inlet temperature of the gas turbine and s-CO 2 cycles are found as the most influential parameters on the thermoeconomic performance of the triple cycle. The proposed triple cycle shows an excellent waste energy recovery potential and superiority over a very thermodynamically efficient cycle from the literature, which included a gas turbine topping cycle and a complex cascade s-CO 2 power cycle used a bottoming cycle. As a result, the proposed triple cycle shows up to 0.9% points higher efficiency while it has fewer heat exchangers and turbomachinery than the cycle from the literature.