Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Diffractive PDF fits and factorisation tests at HERA

A DGLAP next-to-leading-order QCD analysis to extract the diffractive parton distribution functions, using DIS inclusive and dijet diffractive HERA data, is presented. Predictions based on the extracted parton densities are compared to diffractive dijet photoproduction data to discuss factorisation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Permanent Magnet Dipole-Quadrupole and Correcto-Tuner for Small Bore Accelerators

Electromagnets are used to bend electron beams and generate X-ray light. Permanent magnets have many advantages over electromagnets and are being studied as an alternative for small bore accelerators. This paper focuses on the mechanical design of two holders. First, a holder for the corrector and tuner permanent magnet assembly, which aims to correct the errors in the permanent magnetic field strength and orientation. Second, a holder for the dipole-quadrupole magnet assembly, which aims to provide the required magnetic strength to steer the electrons. Prototypes for the corrector, tuner and dipole-quadrupole holders were designed and tested to validate conceptual design. Results show that the corrector magnets can be oriented into a prescribed configuration, the tuner magnets can be oriented simultaneously regardless of the magnetic forces involved, and the dipole-quadrupole magnets can provide the magnetic strength required to steer electrons.

Huschke, Christopher↗

Reduced bleaching in organic nanofibers by bilayer polymer/oxide coating

Para-hexaphenylene (p-6P) molecules exhibit a characteristic photoinduced reaction (bleaching) resulting in a decrease in luminescence intensity upon UV light exposure, which could render the technological use of the nanofibers problematic. In order to investigate the photoinduced reaction in nanofibers, optical bleaching experiments have been performed by irradiating both pristine and coated nanofibers with UV light. Oxide coating materials (SiO{sub x} and Al{sub 2}O{sub 3}) were applied onto p-6P nanofibers. These treatments caused a reduction in the bleaching reaction but in addition, the nanofiber luminescence spectrum was significantly altered. It was observed that some polymer coatings [a statistical copolymer of tetrafluoroethylene and 2,2-bis-trifluoromethyl-4,5-difluoro-1,3-dioxole, P(TFE-PDD), and poly(methyl methacrylate), PMMA] do not interfere with the luminescence spectrum from the p-6P but are not effective in stopping the bleaching. Bilayer coatings with first a polymer material, which should work as a protection layer to avoid modifications of the p-6P luminescence spectrum, and second an oxide layer used as oxygen blocker were tested and it was found that a particular bilayer polymer/oxide combination results in a significant reduction in bleaching without affecting significantly the emission spectrum from the nanofibers.

36 MATERIALS SCIENCE↗

First step toward a synthetic diagnostic for magnetic fluctuation measurements using cross-polarization scattering on DIII-D

Cross-polarization scattering (CPS) provides localized magnetic fluctuation ($\tilde{B}$) measurements in fusion plasmas based on the process where $\tilde{B}$ scatters electromagnetic radiation into the orthogonal polarization. The CPS system on DIII-D utilizes the probe beam of a Doppler backscattering (DBS) diagnostic combined with a cross-view CPS receiver system, which allows simultaneous density and $\tilde{B}$ measurements with good spatial and wavenumber coverage. The interpretation of the signals is challenging due to the complex plasma propagation of the DBS probe beam and CPS receive beams. A synthetic diagnostic for CPS is therefore essential to interpret data and perform detailed validation tests of non-linear turbulence simulations. This work reports a first step toward a synthetic diagnostic for CPS utilizing GENRAY, a 3-D ray tracing code, to simulate the propagation of the probe and scattered rays. The local $\tilde{B}$ wavenumber is calculated from the local O- and X-mode wavenumbers using the wave vector matching scattering condition. The CPS wavenumber values and spatial locations are determined by a complex consideration that includes the local density and $\tilde{B}$ level, receive antenna pattern and orientation, scattering volume, wavenumber values detected at the various scattering centers, and alignment of the magnetic wave vector with the plane perpendicular to the magnetic field. The issue of a spurious CPS signal due to polarization mismatches for launch and receive is also discussed. It is suggested that simultaneous O- and X-mode DBS measurements should be utilized for better understanding of the CPS signal contamination when the cutoff locations for both polarizations are close.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving ProtoDUNE pion cross-section measurements with NuGraph Michel-electron tagging

Understanding hadron-argon interactions is essential for precise neutrino energy reconstruction and final-state interaction modeling in liquid-argon time projection chamber (LArTPC) experiments such as DUNE. In particular, pion absorption and charge-exchange processes constitute significant sources of systematic uncertainty in neutrino oscillation measurements. ProtoDUNE-SP, a large-scale LArTPC prototype operated at the CERN Neutrino Platform and exposed to charged-particle test beams in the few-GeV range, enables direct measurements of these processes. This work focuses on the measurement of differential cross sections for pion absorption and charge exchange using the 2 GeV/c pion beam data from the ProtoDUNE-SP run. A key component of this analysis is the identification of Michel electrons from $\pi \rightarrow \mu \rightarrow e$ decay chains, which helps separate different interaction topologies and improves background rejection. Michel electron identification will also assist in reliably calibrating the electromagnetic response in ProtoDUNE-SP data and for the future DUNE detectors. In this analysis, we apply NuGraph to identify Michel electrons. NuGraph is a graph neural network that models detector hits as nodes connected by spatial and temporal edges for particle and topology classification in LArTPC detectors. We first benchmark NuGraph’s Michel electron classification performance using ICEBERG data, a small-scale LArTPC prototype used for DUNE electronics and reconstruction development, and then transfer the approach to ProtoDUNE-SP. This poster presents the analysis strategy, NuGraph-based classification studies, and discusses how these developments are expected to improve the pion cross-section measurement.

Razafinime, Soamasina Herilala [Cincinnati U.] (OR↗

Irradiation response of commercial, high-Tc superconducting tapes: Electromagnetic transport properties

Effects of low dose irradiation on the electrical transport current properties of commercially available high-temperature superconducting, coated-conductor tapes were investigated, in view of potential applications in the irradiative environment of fusion reactors. Three different tapes, each with unique as-grown flux-pinning structures, were irradiated with Au and Ni ions at energies that provide a range of damage effects, with accumulated damage levels near that expected for conductors in a fusion reactor environment. Measurements using transport current determined the pre- and post-irradiation resistivity, critical current density, and pinning force density, yielding critical temperatures, irreversibility lines, and inferred vortex creep rates. Results show that at the irradiation damage levels tested, any detriment to as-grown pre-irradiation properties is modest; indeed in one case already-superior pinning forces are enhanced, leading to higher critical currents.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Methodology comparison for gamma-heating calculations in material-testing reactors

The Jules Horowitz Reactor (JHR) is a Material-Testing Reactor (MTR) under construction in the south of France at CEA Cadarache (French Alternative Energies and Atomic Energy Commission). It will typically host about 20 simultaneous irradiation experiments in the core and in the beryllium reflector. These experiments will help us better understand the complex phenomena occurring during the accelerated ageing of materials and the irradiation of nuclear fuels. Gamma heating, i.e. photon energy deposition, is mainly responsible for temperature rise in non-fuelled zones of nuclear reactors, including JHR internal structures and irradiation devices. As temperature is a key parameter for physical models describing the behavior of material, accurate control of temperature, and hence gamma heating, is required in irradiation devices and samples in order to perform an advanced suitable analysis of future experimental results. From a broader point of view, JHR global attractiveness as a MTR depends on its ability to monitor experimental parameters with high accuracy, including gamma heating. Strict control of temperature levels is also necessary in terms of safety. As JHR structures are warmed up by gamma heating, they must be appropriately cooled down to prevent creep deformation or melting. Cooling-power sizing is based on calculated levels of gamma heating in the JHR. Due to these safety concerns, accurate calculation of gamma heating with well-controlled bias and associated uncertainty as low as possible is all the more important. There are two main kinds of calculation bias: bias coming from nuclear data on the one hand and bias coming from physical approximations assumed by computer codes and by general calculation route on the other hand. The former must be determined by comparison between calculation and experimental data; the latter by calculation comparisons between codes and between methodologies. In this presentation, we focus on this latter kind of bias. Nuclear heating is represented by the physical quantity called absorbed dose (energy deposition induced by particle-matter interactions, divided by mass). Its calculation with Monte Carlo codes is possible but computationally expensive as it requires transport simulation of charged particles, along with neutrons and photons. For that reason, the calculation of another physical quantity, called KERMA, is often preferred, as KERMA calculation with Monte Carlo codes only requires transport of neutral particles. However, KERMA is only an estimator of the absorbed dose and many conditions must be fulfilled for KERMA to be equal to absorbed dose, including so-called condition of electronic equilibrium. Also, Monte Carlo computations of absorbed dose still present some physical approximations, even though there is only a limited number of them. Some of these approximations are linked to the way how Monte Carlo codes apprehend the transport simulation of charged particles and the productive and destructive interactions between photons, electrons and positrons. There exists a huge variety of electromagnetic shower models which tackle this topic. Differences in the implementation of these models can lead to discrepancies in calculated values of absorbed dose between different Monte Carlo codes. The magnitude of order of such potential discrepancies should be quantified for JHR gamma-heating calculations. We consequently present a two-pronged plan. In a first phase, we intend to perform compared absorbed dose / KERMA Monte Carlo calculations in the JHR. This way, we will study the presence or absence of electronic equilibrium in the different JHR structures and experimental devices and we will give recommendations for the choice of KERMA or absorbed dose when calculating gamma heating in the JHR. In a second phase, we intend to perform compared TRIPOLI4 / MCNP absorbed dose calculations in a simplified JHR-representative geometry. For this comparison, we will use the same nuclear data library for both codes (the European library JEFF3.1.1 and photon library EPDL97) so as to isolate the effects from electromagnetic shower models on absorbed dose calculation. This way, we hope to get insightful feedback on these models and their implementation in Monte Carlo codes. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of Mechanical and Electromagnetic Interference Shielding Properties of Nickel–CFRP Textile Composites

The most common materials used for electromagnetic interference shielding are metals and their alloys. However, those materials are heavy and highly reflective. In order to eliminate or reduce the intensity of wave radiation in their working environment, lightweight materials that have interference shielding properties are needed. In this paper, nickel wire mesh yarns (warps) were woven into carbon fibers-reinforced plastic yarns (wefts) to produce metal–carbon textile composite materials. The plain weave and 2/2 twill weave techniques were used, and the woven fabrics were laminated to manufacture experimental test samples. The nickel, which has high magnetic permeability and good electric conductivity, and carbon fibers, which have good electrical, thermal and mechanical properties, were used together to achieve the desired properties. The shielding effectiveness of each sample was investigated using a network analyzer connected with coaxial transmission line test in accordance with ASTM 4935-99 standard, with the frequencies ranging from 500 MHz to 1.5 GHz. Here, the plain weave structure showed higher shielding effectiveness than twill weave. The absorption losses for both materials were relatively greater than reflection losses. In reference to the orientation of wire mesh yarns about the loading axis, the tensile strengths in the transversal direction were 19.04 and 16.34% higher than the tensile strengths in longitudinal direction for plain weave and twill weave, respectively. The fractography analysis with SEM showed a ductile fracture of wire mesh and brittle fracture of epoxy matrix and carbon fibers.

36 MATERIALS SCIENCE↗

Collisional and Spectroscopic Studies of Exotic Atoms Using Ultra-Slow Antiprotons

Antiproton, the antiparticle of proton, is a unique projectile in the study of atomic collision physics, which can be treated theoretically either as a 'negative proton' or a 'heavy electron'. Atomic capture of an antiproton will result in formation of a highly excited exotic atom. Antiprotonic helium atom has been studied intensively by means of precision laser spectroscopy, which has led to a stringent determination of antiproton mass and charge to a level of ppb. Comparison of these values with those of proton gives one of the best tests of CPT invariance, the most fundamental symmetry in physics. However, the dynamic processes of antiproton capture remain unclarified, except for some indirect information given by those optical and X-ray observations. With an aim to produce an antiproton beam at atomic-physics energies for 'pure' collision experiments, we have so far developed techniques to decelerate, cool and confine antiprotons in vacuo, using a sequential combination of the Antiproton Decelerator (AD) at CERN, a Radio-Frequency Quadrupole Decelerator (RFQD), and an electromagnetic trap. Our recent success in stable extraction of monoenergetic ultra-slow antiprotons, about 3x10{sup 5} in number available every 5 minutes, has opened up the possibility to study ionization and atomic capture processes between an antiproton thus provided as a beam and an atom prepared in the form of a supersonic gas-jet target, at an unprecedented low energy from 10 eV to 1 keV under the single-collision condition. Our design and strategy of the cross-beam experiments are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

A MULTIWAVELENGTH STUDY ON THE HIGH-ENERGY BEHAVIOR OF THE FERMI/LAT PULSARS

Using archival as well as freshly acquired data, we assess the X-ray behavior of the Fermi/Large Area Telescope {gamma}-ray pulsars listed in the First Fermi source catalog. After revisiting the relationships between the pulsars' rotational energy losses and their X-ray and {gamma}-ray luminosities, we focus on the distance-independent {gamma}-to-X-ray flux ratios. When plotting our F{sub {gamma}}/F{sub X} values as a function of the pulsars' rotational energy losses, one immediately sees that pulsars with similar energetics have F{sub {gamma}}/F{sub X} spanning three decades. Such spread, most probably stemming from vastly different geometrical configurations of the X-ray and {gamma}-ray emitting regions, defies any straightforward interpretation of the plot. Indeed, while energetic pulsars do have low F{sub {gamma}}/F{sub X} values, little can be said for the bulk of the Fermi neutron stars. Dividing our pulsar sample into radio-loud and radio-quiet subsamples, we find that, on average, radio-quiet pulsars do have higher values of F{sub {gamma}}/F{sub X}, implying an intrinsic faintness of their X-ray emission and/or a different geometrical configuration. Moreover, despite the large spread mentioned above, statistical tests show a lower scatter in the radio-quiet data set with respect to the radio-loud one, pointing to a somewhat more constrained geometry for the radio-quiet objects with respect to the radio-loud ones.

79 ASTRONOMY AND ASTROPHYSICS↗

XUV frequency-comb metrology on the ground state of helium

The operation of a frequency comb at extreme ultraviolet (xuv) wavelengths based on pairwise amplification and nonlinear upconversion to the 15th harmonic of pulses from a frequency-comb laser in the near-infrared range is reported. It is experimentally demonstrated that the resulting spectrum at 51 nm is fully phase coherent and can be applied to precision metrology. The pulses are used in a scheme of direct-frequency-comb excitation of helium atoms from the ground state to the 1s4p and 1s5p {sup 1} P{sub 1} states. Laser ionization by auxiliary 1064 nm pulses is used to detect the excited-state population, resulting in a cosine-like signal as a function of the repetition rate of the frequency comb with a modulation contrast of up to 55%. Analysis of the visibility of this comb structure, thereby using the helium atom as a precision phase ruler, yields an estimated timing jitter between the two upconverted-comb laser pulses of 50 attoseconds, which is equivalent to a phase jitter of 0.38 (6) cycles in the xuv at 51 nm. This sets a quantitative figure of merit for the operation of the xuv comb and indicates that extension to even shorter wavelengths should be feasible. The helium metrology investigation results in transition frequencies of 5 740 806 993 (10) and 5 814 248 672 (6) MHz for excitation of the 1s4p and 1s5p {sup 1} P{sub 1} states, respectively. This constitutes an important frequency measurement in the xuv, attaining high accuracy in this windowless part of the electromagnetic spectrum. From the measured transition frequencies an eight-fold-improved {sup 4}He ionization energy of 5 945 204 212 (6) MHz is derived. Also, a new value for the {sup 4}He ground-state Lamb shift is found of 41 247 (6) MHz. This experimental value is in agreement with recent theoretical calculations up to order m{alpha}{sup 6} and m{sup 2}/M{alpha}{sup 5}, but with a six-times-higher precision, therewith providing a stringent test of quantum electrodynamics in bound two-electron systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser acceleration of light ions from a thin homogeneous foil of complex atomic composition

A model of the acceleration of light impurity particles from a plane ultrathin foil of complex ion composition by a high-power ultrashort high-contrast laser pulse is proposed. A study is made of both purely Coulomb ion acceleration, typical of extremely high electron energies, and ion acceleration under the conditions of space charge separation, determined by the finite typical electron temperature. Exact and approximate analytic approaches to describing impurity particle acceleration are developed. The spatial and spectral parameters of accelerated light particles are obtained, and their dynamics is investigated as a function of their relative charge density in a model of test impurity particles and in a model in which their own electrostatic field is taken into account. Optimum conditions for the generation of quasi-monoenergetic ions are discussed, depending on the laser radiation parameters and target composition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Embedded Sensors and Controls to Improve Component Performance and Reliability -- Bench-scale Testbed Design Report

Embedded instrumentation and control systems that can operate in extreme environments are challenging due to restrictions on sensors and materials. As a part of the Department of Energy's Nuclear Energy Enabling Technology cross-cutting technology development programs Advanced Sensors and Instrumentation topic, this report details the design of a bench-scale embedded instrumentation and control testbed. The design goal of the bench-scale testbed is to build a re-configurable system that can rapidly deploy and test advanced control algorithms in a hardware in the loop setup. The bench-scale testbed will be designed as a fluid pump analog that uses active magnetic bearings to support the shaft. The testbed represents an application that would improve the efficiency and performance of high temperature (700 C) pumps for liquid salt reactors that operate in an extreme environment and provide many engineering challenges that can be overcome with embedded instrumentation and control. This report will give details of the mechanical design, electromagnetic design, geometry optimization, power electronics design, and initial control system design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-BRA-02: Electromagnetic Tracking in Brachytherapy as An Advanced Modality for Treatment Quality Assurance

Purpose: To present the use of Electromagnetic Tracking (EMT) for quality assurance in brachytherapy by means of phantom studies and to assess the clinical applicability of EMT during HDR breast brachytherapy. Methods: An EMT system was investigated to examine its suitability for clinical applications in brachytherapy. A field generator served as electromagnetic field emitter. Sensors (magnetic sensitive only), connected to a control unit, were used and their respective position and orientation inside a pre-defined measurement volume (500 mm cube length) determined. Up to three 6DoF sensors were placed on the phantom’s surface to obtain additional reference coordinates used to derive relative measured positions of a smaller 5DoF sensor inserted in the 6F catheters of the implant. The catheters were successively measured by manual displacement of the sensor at ∼40 mm/s. The measured catheter tracks, acquired multiple times at various locations (CT and treatment room), were smoothed, divided into intervals (2.5 mm dwell step size), registered (rigid Iterative Closest Point transformation) and compared against the known phantom geometry. Results: The reference coordinates were used to exclude the influence of external (e.g., respiratory-induced) motion. Precision tests in a clinical setting showed variances below 1 mm (translational) and 1° (rotational), respectively. Our method for catheter reconstruction preserved the length of the tracked catheter (within 1 mm). The measured tracking accuracy was 1±0.3 mm (maximum: 2 mm). The results are less accurate in environments potentially interfering with the magnetic field, e.g., in the vicinity of ferromagnetic table components. Conclusion: Our EMT system is able to perform reproducible and accurate catheter tracking and reconstruction. Currently, measurements of the implant geometry in HDR breast treatments are initiated. Online implant monitoring by means of EM tracking may be a first step towards advanced brachytherapy treatment QA. The study was financially supported by ELEKTA | Nucletron. There are no further disclosures and conflicts.

60 APPLIED LIFE SCIENCES↗

Design of the Cooling System of the Mu2e Electromagnetic Calorimeter at Fermi National Accelerator Laboratory

In this Thesis, the cooling of the electronics of the Mu2e calorimeter has been discussed. The analysed technical solutions for the cooling of the front-end boards, the waveform digitizers boards and the interface boards have been presented. The project of the crate has been showed in detail. It is placed in the outer surface of the calorimeter disk and it is a mechanical support for the boards and also part of the thermal circuit. The distributing system of the refrigerant fluid for the whole calorimeter has been analysed too. Then the manufacturing solutions of the crates and the components for the thermal path have been developed. At the end, the main experimental tests have been presented. They are going to be realized in the next months.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-domain all-frequency stable formulation for low-frequency electromagnetic simulation with Newmark-β time integration

An implicitly Coulomb-gauged A-ϕ formulation has previously been proposed and validated for finite ele- ment simulations of low-frequency and multiscale electromag- netic problems in the frequency domain. This formulation has demonstrated numerical stability across all frequencies, with its accuracy, efficiency, and iterative convergence established in various frequency-domain scenarios. However, direct time- domain computation is often preferable for wideband electro- magnetic problems and is typically indispensable in nonlinear and multiphysics simulations. In this work, the A-ϕ formulation is extended to the time domain. By incorporating the well-known Newmark-β time integration scheme, the proposed formulation is validated through capacitive and inductive test cases. The results confirm the solution’s accuracy and demonstrate the formulation’s stability in the time domain.

Mekonnen, Minyechil↗

Recent progress in low energy neutrino scattering physics and its implications for the standard and beyond the standard model physics

Neutrinos continue to provide a testing ground for the structure of the standard model of particle physics as well as hints towards the physics beyond the standard model. Neutrinos of energies spanning over several orders of magnitude, originating in many terrestrial and astrophysical processes, have been detected via various decay and interaction mechanisms. At MeV scales, there has been one elusive process, until a few years ago, known as coherent elastic neutrino-nucleus scattering (CEvNS) that was theoretically predicted over five decades ago but was never observed experimentally. The recent experimental observation of the CEvNS process by the COHERENT collaboration at a stopped pion neutrino source has inspired physicists across many subfields. This has vital implications for nuclear physics, high-energy physics, astrophysics, and beyond. CEvNS, being a low-energy process, provides a natural window to study light, weakly-coupled, new physics in the neutrino sector. In this review, we intend to provide the current status of low energy neutrino scattering physics and its implications for the standard and beyond the standard model physics. We discuss the general formalism of calculating the tree-level CEvNS cross section and present estimated theoretical uncertainties on the CEvNS cross section stemming from different sources. We also discuss the inelastic scattering of tens of MeV neutrinos that have implications for supernova detection in future neutrino experiments. We discuss how the CEvNS experiments can be used as a testing ground for the Standard Model (SM) weak physics as well as in searching for the Beyond the Standard Model (BSM) physics signals. Any deviation from the SM predicted event rate either with a change in the total event rate or with a change in the shape of the recoil spectrum, could indicate new contributions to the interaction cross-section. The SM implications include the study of weak nuclear form factor and weak mixing angle. The BSM studies include non-standard interactions, neutrino electromagnetic properties, and sterile neutrino searches. In conclusion, stopped pion facilities are also a copious source of neutral and changed mesons that allow study of several dark sector physics scenarios such as vector portal models, leptophobic dark matter as well as axion-like particle searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid level sensing for harsh environment applications using distributed fiber optic temperature measurements

This work demonstrates the measurement of liquid level from spatially distributed temperature measurements using optical frequency domain reflectometry. The goal of this work is to provide initial evidence for a liquid level sensor concept that could be applied in harsh environments such as those with: conductive, flammable, or other chemically aggressive media; electromagnetic interference; high temperatures (up to ~1000 °C); and neutron/gamma radiation. The sensor concept includes fiber optic sensors, along with an insulated heater wire assembled inside a protective Inconel 600 sheath. When the heater is not powered, the sensor provides spatially distributed temperature measurements along the length of the fiber. When the heater is powered, the difference in heat transfer in the liquid vs. vapor sections leads to a higher fiber temperature at locations above the liquid/vapor interface. The initial demonstration described in this work tested the sensor in a tank of water that was drained in increments of 2.5 cm. A model for determining liquid level from the distributed temperature measurements was developed that resulted in an accuracy of ±0.5 cm. Finally, the paper addresses potential effects of axial conduction through the sensor sheath, as well as ways to limit these effects to avoid “smearing” of what would otherwise be a step change in temperature at the liquid/vapor interface.

42 ENGINEERING↗