Search NASA⌕ Search

SEARCH · Search NASA

Results for “Excel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A LYSO crystal array readout by silicon photomultipliers as compact detector for space applications

Precise measurements of GeV range gamma rays help narrow down among var- ious gamma emission models and increase sensitivity for dark matter searches. Construction of precise as well as compact instruments requires detectors with high efficiency, high stopping power, excellent energy resolution, and excellent angular resolution. Fast and bright crystal scintillators coupled with small foot- print photo-detectors are suitable candidates. We prototyped a detector array consisting of four LYSO crystals where each crystal is read out by a 2x2 SensL ArrayJ60035 silicon photomultipliers. The LYSO crystals were chosen because of their good light yield, fast decay time, demonstrated radiation hardness, and small radiation length. Here, we used the silicon photomultiplier arrays as photo- detectors because of their small size, simple readout, low voltage operation, and immunity to magnetic elds. We also studied the detector performance in the energy range of interest by exposing it to 2-16 GeV particles produced at the Test Beam Facility of Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗

Fast timing with induced current detectors

Vertically integrated (3D) combinations of sensors and electronics offer the ability to fabricate small, fine pitch pixels with very small total capacitance monolithically integrated with complex circuitry. The small capacitance, enabled by the fine pixel pitch and low interconnect capacitance available in 3D hybrid bonding, provides excellent signal/noise with moderate power. This combination enables fabrication of integrated sensors and electronics with both excellent position and time resolution. We describe the capabilities of such a system and the limitations imposed by geometry and power. Furthermore, we illustrate how a similar geometry can be used to provide very fast timing of x-ray arrival in a thick sensor by utilizing the transient induced current in a field of pixels.

3D integration↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Key results from irradiation and post-irradiation examination of AGR-1 UCO TRISO fuel

The AGR-1 irradiation experiment was performed as the first test of tristructural isotropic (TRISO) fuel in the US Advanced Gas Reactor Fuel Development and Qualification Program. The experiment consisted of 72 right cylinder fuel compacts containing approximately 3 × 105 coated fuel particles with uranium oxide/uranium carbide (UCO) fuel kernels. The fuel was irradiated in the Advanced Test Reactor for a total of 620 effective full power days. Fuel burnup ranged from 11.3 to 19.6% fissions per initial metal atom and time-average, volume-average irradiation temperatures of the individual compacts ranged from 955 to 1136 °C. This paper focuses on key results from the irradiation and post-irradiation examination, which revealed a robust fuel with excellent performance characteristics under the conditions tested and have significantly improved the understanding of UCO coated particle fuel irradiation behavior. The fuel exhibited zero TRISO coating failures (failure of all three dense coating layers) during irradiation and post-irradiation safety testing at temperatures up to 1700 °C. Advanced PIE methods have allowed particles with SiC coating failure that were discovered to be present in a very-low population to be isolated and meticulously examined, which has elucidated the specific causes of SiC failure in these specimens. The level of fission product release from the fuel during irradiation and post-irradiation safety testing has been studied in detail. Results indicated very low release of krypton and cesium through intact SiC and modest release of europium and strontium, while also confirming the potential for significant silver release through the coatings depending on irradiation conditions. Focused study of fission products within the coating layers of irradiated particles down to nanometer length scales has provided new insights into fission product transport through the coating layers and the role various fission products may have on coating integrity. The broader implications of these results and the application of lessons learned from AGR-1 to fuel fabrication and post-irradiation examination for subsequent fuel irradiation experiments as part of the US fuel program are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity study of hydrogen Soret transport in yttrium Hydride-Based nuclear fuel

Yttrium hydride is an excellent solid neutron moderator material for high temperature nuclear reactor applications due to its high hydrogen density and exceptional hydride stability at high temperatures. Despite these attractive characteristics, the details of how hydrogen behaves within yttrium hydride while temperature gradients exist are still not well understood. The evolution of the hydrogen composition profile resulting from a temperature gradient requires knowledge of hydrogen’s heat of transport, a critical parameter that has not yet been measured for this material. In this work, we perform hydride redistribution, hydrogen dissociation, and hydrogen leakage calculations while varying the Soret heat of transport of hydrogen in yttrium hydride to elucidate the sensitivity of hydride stability under temperature gradients to this parameter. This study analyzes hydride stability of a hypothetical uranium-yttrium hydride nuclear fuel design during operation of a high temperature liquid metal-cooled nuclear reactor. Assuming U-YH x could be fabricated in a physically stabilized manner, this fuel system can likely maintain hydride stability while operating at very high power densities and temperatures. We find that even though the hydrogen dissociation pressure in the gas gap does vary by several percent as the heat of transport temperature parameter is varied, the hydrogen content in the U-YH x fuel meat is relatively insensitive to this parameter over the course of a high burnup fuel cycle; this is due to yttrium hydride’s excellent hydrogen retention under the high temperature conditions considered here. Here, this suggests that hydride stability analyses are insensitive to the value of the Soret heat of transport in U-YH x under steady state liquid metal-cooled reactor conditions. However, the susceptibility to internal gas overpressurization-induced stress-rupture of the cladding during a high temperature transient is more sensitive to this parameter due to the non-linear dependence of hydrogen gas dissociation pressure vs. composition and temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation hard gallium oxide scintillators for high count rate radiation detection

Despite decades of materials research, the availability of appropriate crystalline radiation-hard scintillators with ultrafast decay times (~10ns) and high light yields (>2000 ph/MeV) are still limited. In this study, we demonstrate the potential of gallium oxide (β-Ga 2 O 3 ) based scintillators for high count rate applications. The low-cost rugged β-Ga 2 O 3 scintillators were grown using the optical float zone (FZ) technique. Several dopants and growth atmospheres were used to demonstrate the balance between ultrafast primary decay time and the light yield of the scintillators. Light yields as high as 6446 ± 716 ph/MeV were obtained with 18.3 ns decay time for 662 keV gamma rays. Decay times as fast as 12ns were obtained with a 3212 ± 357 ph/MeV light yield. An excellent 662 keV gamma energy resolution of 7% was obtained using the β-Ga 2 O 3 :Ce crystals. Even with these excellent scintillation properties, the gamma radiation hardness of β-Ga 2 O 3 crystals was better than the leading radiation-hard lead tungstate (PbWO 4 ) crystals. Twenty-six scintillators fabricated from the grown β-Ga 2 O 3 crystals were tested for radiation hardness with a 60 Co gamma irradiation rate of 14 krad/h with a total radiation dose of 2 Mrad. The scintillation properties of these crystals remained unaffected. To date, no other scintillator has demonstrated such high radiation resistance. Furthermore, these FZ-grown low-cost, non-hygroscopic, and high-density β-Ga 2 O 3 scintillators can replace the existing scintillators in many applications ranging from nuclear and high energy physics experiments to nuclear security.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two novel bipolar hosts based on 1,2,4-triazole derivatives for highly efficient red phosphorescent OLEDs showing a small efficiency roll-off

Achieving high efficiency and small efficiency roll-off simultaneously for red phosphorescent organic light-emitting diodes (PhOLEDs) is still a challenge, which is largely related to the host material used in device fabrication. In this wok, we designed and synthesized two novel bipolar host materials, termed 2Cz-TAZ-2Cz and 3Cz-TAZ-3Cz in which 1,2,4-triazole was introduced at the C-2 and C-3 positions of 9-phenylcarbazole, respectively. The materials' photophysical properties were studied in detail.. It was found that 2Cz-TAZ-2Cz and 3Cz-TAZ-3Cz possess excellent thermal stability with thermal decomposition temperature (Td) of 457 and 432 °C, respectively, and that 2Cz-TAZ-2Cz has a better bipolar carrier transport compared to the typical host 4, 4'-bis(9H-carbazole-9-yl)-biphenyl (CBP). Based on the excellent performance of these materials, red phosphorescent OLEDs with 2Cz-TAZ-2Cz and 3Cz-TAZ-3Cz as hosts and bis(1-phenylisoquinoline)(acetylacetonate)iridium (III) (Ir(piq) 2 acac) as emitter were fabricated. The optimized 2Cz-TAZ-2Cz -based device achieved a high maximum current efficiency and external quantum efficiency (EQE) of 12.4 cd/A and 16.60%, respectively. Moreover, this device also exhibits a small efficiency roll-off, i.e., the EQE is lowered by only 12.0% and 29.4% at a brightness of 1000 cd/m 2 and 10,000 cd/m 2 , respectively, which is superior to CBP-based device, indicating a potential far-reaching application.

42 ENGINEERING↗

An analysis of lower-dimensional approximations to the scalar dissipation rate using direct numerical simulations of plane jet flames

The difficulty of experimental measurements of the scalar dissipation rate in turbulent flames has required researchers to estimate the true three-dimensional (3D) scalar dissipation rate from one-dimensional (1D) or two-dimensional (2D) gradient measurements. In doing so, some relationship must be assumed between the true values and their lower dimensional approximations. We develop these relationships by assuming a form for the statistics of the gradient vector orientation, which enables several new results to be obtained and the true 3D scalar dissipation PDF to be reconstructed from the lower-dimensional approximations. We use direct numerical simulations (DNS) of turbulent plane jet flames to examine the orientation statistics, and verify our assumptions and final results. We develop and validate new theoretical relationships between the lower-dimensional and true moments of the scalar dissipation PDF assuming a log-normal true PDF. We compare PDFs reconstructed from lower-dimensional gradient projections with the true values and find an excellent agreement for a 2D simulated measurement and also for a 1D simulated measurement perpendicular to the mean flow variations. Comparisons of PDFs of thermal dissipation from DNS with those obtained via reconstruction from 2D experimental measurements show a very close match, indicating this PDF is not unique to a particular flame configuration. We develop a technique to reconstruct the joint PDF of the scalar dissipation and any other scalar, such as chemical species or temperature. Reconstructed conditional means of the hydroxyl mass fraction are compared with the true values and an excellent agreement is obtained.

Energy & Fuels↗

Mechanical Reliability and Life Prediction of Coated Metallic Interconnects within Solid Oxide Fuel Cells

Metallic cell interconnects (IC) made of ferritic stainless steels, i.e., iron-based alloys, have been increasingly favored in the recent development of planar solid oxide fuel cells (SOFCs) because of their advantages in excellent imperviousness, low electrical resistance, ease in fabrication, and cost effectiveness [1]. Typical SOFC operating conditions inevitably lead to the formation of oxide scales on the surface of ferritic stainless steel, which could cause delamination, buckling, and spallation resulting from the mismatch of the coefficient of thermal expansion and eventually reduce the lifetime of the interconnect components. Various protective coating techniques have been applied to alleviate these drawbacks [2]. In the present work, a fracture-mechanics-based quantitative modeling framework has been established to predict the mechanical reliability and lifetime of the spinel-coated, surface-modified specimens under an isothermal cooling cycle. Analytical solutions have been formulated to evaluate the scale/substrate interfacial strength and determine the critical oxide thickness in terms of a variety of design factors, such as coating thickness, material properties, and uncertainties. The findings then are correlated with the experimentally measured oxide scale growth kinetics to quantify the predicted lifetime of the metallic interconnects.

Solid oxide fuel cell (SOFC), Ferritic stainless s↗

An ICP-OES method for the precise and accurate quantification of rare earth elements in natural water: A comparative study from mine waste sites in New Mexico, USA

Inductively coupled plasma techniques such as ICP-OES and ICP-MS are routinely used to determine the concentrations of rare earth elements (REE) in water samples. However, their performance for the determination of REE concentration in mine drainage waters from epithermal vein and porphyry copper mining districts has not been evaluated extensively. In this work, we develop an REE analysis method on an Agilent 5900 ICP-OES instrument and assess the accuracy and precision for the quantification of REE in the natural waters collected from mine adits and an acid seep of mine sites in the Steeple Rock and Hillsboro mining districts, New Mexico, USA. The total REE concentrations in the water samples were measured using the methods we developed for both ICP-OES and ICP-MS. The power of the new ICP-OES method lies in routine analysis of μg/L level concentrations normally analyzed using ICP-MS, including a U.S. Geological Survey standard reference sample, laboratory blank samples spiked with a National Institute of Standards and Technology traceable standard, and surface water samples from mine waste sites. This ICP-OES method achieves low quantification limits ranging from 0.2 to 5 μg/L and excellent analytical accuracy and precision for REE analysis. The precision of light (La-Gd) and heavy (Tb-Lu) REE analysis using this method are better than 5% at average concentrations above 5 ± 4 μg/L and 3 ± 2 μg/L, respectively, and 3% at average concentrations above 10 ± 9 μg/L and 5 ± 4 μg/L, respectively. This method also shows excellent sensitivity and reproducibility for our laboratory and field samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discovery of a meta-stable Al-Sm phase with unknown stoichiometry using a genetic algorithm

Unknown crystalline phases observed during the devitrification process of glassy metal alloys significantly limit our ability to understand and control phase selection in these systems driven far from equilibrium. Here, we report a new meta-stable Al 5 Sm phase identified by simultaneously searching Al-rich compositions of the Al–Sm system, using an efficient genetic algorithm. The excellent match between calculated and experimental X-ray diffraction patterns confirms that this new phase appeared in the crystallization of melt-spun Al 90 Sm 10 alloys.

Zhang, Feng↗

Brain-implantable multifunctional probe for simultaneous detection of glutamate and GABA neurotransmitters

We report Glutamate (GLU) and gamma-aminobutyric acid (GABA) are neurotransmitters (NTs) with an essential role in signal transmission in the brain. Brain disorders, such as epilepsy, Alzheimer's and Parkinson's diseases, and traumatic brain injury can be linked to imbalances in the GLU-GABA homeostasis that occurs in sub-second to seconds time frames. Current measurement techniques can detect these two NT concentrations simultaneously only in vitro. The present work reports on the fabrication of a silicon multifunctional biosensor microarray probe for sub-second simultaneous GLU-GABA detection in real-time, with excellent analyte sensitivity and selectivity and in vivo capabilities. The novel Si probes feature four surface-functionalized platinum ultramicroelectrodes (UMEs) for simultaneous amperometric detection of GLU and GABA with a sentinel, and a built-in microfluidic channel for the introduction of neurochemicals in the proximity of the UMEs. The microchannel also allows functioning of an On-Demand In-situ Calibrator that runs in-situ biosensor calibration. The probe exhibited excellent robustness at insertion in agarose-gel brain-tissue-mimicking test, and remarkably high hydrogen peroxide sensitivity (a by-product of GLU-GABA enzyme biosensor) with values on the order of 5000 nA μM -1 cm -2 and maximum sensitivities of 204 ± 15 nA μM -1 cm -2 and 37 ± 7 nA μM -1 cm -2 for GLU and GABA, respectively. Furthermore, the limit of detection of the biosensors reached as low as 7 nM, 165 nM and 750 nM for H 2 O 2 , GLU and GABA, respectively and a temporal resolution of hundreds of milliseconds during in vivo studies using freely moving rats.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced passivation and stability of negative charge injected SiN x with higher nitrogen content on the boron diffused surface of n-type Si solar cells

This paper explores the potential of the negatively charged SiN x using plasma charge injection technology to passivate the front textured boron-diffused emitter of n-type Si solar cells. The high-x value single SiN x layer with x ≥ 1.30 (x = N/Si) previously developed for the planarized rear-side passivation of p-type silicon solar cells, with an excellent passivation and charge stability, was found to be unacceptable for the passivation on the front textured boron emitter of n-type cells due to a severe bulk lifetime degradation issue. Therefore, in this study, we investigated a new concept of depositing a dual-x SiN x with a low-x SiN x layer (x~1.01) on top of a high-x SiN x layer (x~1.30) for passivation of the front textured rough surface of boron diffused emitter in n-type cells. Here, the optimized dual-x SiN x stack reveals the promise of charge retention for more than 25 years in field operation as well as excellent passivation of boron-doped emitter without bulk lifetime degradation. N-type cells with the optimized dual-x SiN x after charge injection show comparable cell performance to Al 2 O 3 passivated reference cells. The results of cell-level light stability tests using one-cell minimodules exhibit cell performance decay characteristics similar to the traditional Al 2 O 3 /SiN x passivated reference module.

14 SOLAR ENERGY↗

>24% screen printed Cu contacted n-TOPCon solar cells with successful implementation of LECO process

In this paper, we report the successful fabrication of >24.0 % efficiency n-TOPCon Si solar cells with screen-printed, fire-through Cu contact to n-TOPCon on the rear side and Ag contacted boron emitter on the front side by implementing optimized firing and LECO conditions. The highest efficiency (24.3%) Cu contacted n-TOPCon cell in this study showed excellent cell performance parameters with V oc >730 mV, J sc of 41.1 mA/cm 2 and FF of 80.8%, resulting in an absolute efficiency gap of 0.2% between Cu-contacted and fully Ag contacted n-TOPCon cells (24.5%). The mini-module fabricated with the Cu contacted n-TOPCon cell showed excellent reliability and durability of open-circuit voltage (V oc ), pseudo fill factor (pFF) and efficiency after prolonged damp-heat tests. Such high efficiency screen printed Cu contacted n-TOPCon cells provide unique opportunity to replace very expensive Ag contact on n-TOPCon with cheaper screen printable Cu metal pastes.

14 SOLAR ENERGY↗

Solid-state polymer magnesium supercapacitor

Here, the present article focuses on the development of a highly ion-conductive, solvent-free, solid-state polymer electrolyte membrane (PEM) via photopolymerization of polyethylene glycol diacrylate (PEGDA) network from its homogeneous melt mixtures containing succinonitrile (SCN) plasticizer and magnesium bis(trifluoromethane sulfonyl) imide Mg(TFSI) 2 salt. The above solid-state Mg-PEM exhibits a Helmholtz electric double-layer capacitor (EDLC) behavior in its supercapacitive symmetric carbonaceous electrode configuration. The electrochemical stability for this PEM membrane (20/40/40 PEGDA/SCN/Mg (TFSI) 2 ) was found to be approximately 3 V from linear sweep voltammetry with a specific capacitance of about 44 F/g from cyclic voltammetry and an energy density of approximately 17 Wh/kg in the 0–2 V range from the constant current density (CCD) experiment. Of particular interest is its excellent capacity retention of over 11,200 cycles, thus tested with the Coulombic efficiency of over 87%. Moreover, the energy density after extensive cycling for 11,200 has increased to approximately 56 Wh/kg at 10 mV/s in the potential range of 0–3 V relative to 17 Wh/kg in the potential range of 0–2 V at the same scan rate, attesting the excellent electrochemical stability and long life of the present Mg-PEM supercapacitor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗