Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Experimental Determination of the Dynamic Hydraulic Transfer Function for the J-2X Oxidizer Turbopump: Methodology - Part One

An advanced methodology for extracting the hydraulic dynamic pump transfer matrix (Yp) for a cavitating liquid rocket engine turbopump inducer+impeller has been developed. The transfer function is required for integrated vehicle pogo stability analysis as well as optimization of local inducer pumping stability. Laboratory pulsed subscale waterflow test of the J-2X oxygen turbo pump is introduced and our new extraction method applied to the data collected. From accurate measures of pump inlet and discharge perturbational mass flows and pressures, and one-dimensional flow models that represents complete waterflow loop physics, we are able to derive Yp and hence extract the characteristic pump parameters: compliance, pump gain, impedance, mass flow gain. Detailed modeling is necessary to accurately translate instrument plane measurements to the pump inlet and discharge and extract Yp. We present the MSFC Dynamic Lump Parameter Fluid Model Framework and describe critical dynamic component details. We report on fit minimization techniques, cost (fitness) function derivation, and resulting model fits to our experimental data are presented. Comparisons are made to alternate techniques for spatially translating measurement stations to actual pump inlet and discharge.

Zoladz, Tom↗

Aerobic Fitness Does Not Contribute to Prediction of Orthostatic Intolerance

Several investigations have suggested that orthostatic tolerance may be inversely related to aerobic fitness (VO (sub 2max)). To test this hypothesis, 18 males (age 29 to 51 yr) underwent both treadmill VO(sub 2max) determination and graded lower body negative pressures (LBNP) exposure to tolerance. VO(2max) was measured during the last minute of a Bruce treadmill protocol. LBNP was terminated based on pre-syncopal symptoms and LBNP tolerance (peak LBNP) was expressed as the cumulative product of LBNP and time (torr-min). Changes in heart rate, stroke volume cardiac output, blood pressure and impedance rheographic indices of mid-thigh-leg initial accumulation were measured at rest and during the final minute of LBNP. For all 18 subjects, mean (plus or minus SE) fluid accumulation index and leg venous compliance index at peak LBNP were 139 plus or minus 3.9 plus or minus 0.4 ml-torr-min(exp -2) x 10(exp 3), respectively. Pearson product-moment correlations and step-wise linear regression were used to investigate relationships with peak LBNP. Variables associated with endurance training, such as VO(sub 2max) and percent body fat were not found to correlate significantly (P is less than 0.05) with peak LBNP and did not add sufficiently to the prediction of peak LBNP to be included in the step-wise regression model. The step-wise regression model included only fluid accumulation index leg venous compliance index, and blood volume and resulted in a squared multiple correlation coefficient of 0.978. These data do not support the hypothesis that orthostatic tolerance as measured by LBNP is lower in individuals with high aerobic fitness.

Convertino, Victor A.↗

Comparison of predicted and measured elastohydrodynamic film thickness in a 20-millimeter-bore ball bearing

Elastohydrodynamic film thicknesses were measured for a 20-mm bore ball bearing using the capacitance technique. The bearing was thrust loaded to 90, 445, and 778 N (20, 100, and 175 lb). The corresponding maximum contact stress on the inner race was 1.28, 2.09, and 2.45 GPa (185 000, 303,000, and 356, 000 psi). Test speeds ranged from 400 to 15,000 rpm. Measurements were taken with four different lubricants: (1) synthetic paraffinic; (2) synthetic paraffinic with additives; (3) synthetic type II aircraft oil; and (4) synthetic cycloaliphatic hydrocarbon traction fluid. The test bearing was mist lubricated. Test temperatures were 27, 65, and 121 C (80, 150, and 250 F). The measured results for the various test parameters were compared to theoretical predictions from computer programs. Also the data were plotted on dimensionless coordinates and compared to several classical isothermal theories.

Coy, J. J.↗

The measurement, modeling, and prediction of traction for rocket propellant 1

Traction tests were performed on RP-1, a common kerosene based rocket propellant. Traction data on this fluid are required for purposes of turbopump bearing design, using codes such as SHABERTH. To obtain the traction data, an existing twin disc machine was used, operating under the side slip mode and using elliptical contacts. The range of test variables were: contact peak Hertz stress from 1.0 to 2.0 GPa, disc surface speed from 10 to 50 m/s, fluid inlet temperature from 30 to 70 C, and with a contact aspect ratio of 1.7. The resulting traction curves were reduced to fundamental fluid property parameters using the Johnson and Tevaarwerk traction model. Theoretical traction predictions were performed by back substitution of the fundamental properties into the traction model. Comparison of the predicted with the measured curves gives a high degree of confidence in the correctness of the traction model. For purposes of input to the NASA SHABERTH program, the traction model was next used to predict the expected traction of RP-1 under line contact conditions.

Tevaarwerk, J. L.↗

JSC Director's Discretionary Fund 1992 Annual Report

Annual report of the Johnson Space Center Director's Discretionary Fund documenting effective use of resources. The $1,694,000 funding for FY92 was distributed among 27 projects. The projects are an overall aid to the NASA mission, as well as providing development opportunities for the science and engineering staff with eventual spinoff to commercial uses. Projects described include space-based medical research such as the use of stable isotopes of deuterium and oxygen to measure crew energy use and techniques for noninvasive motion sickness medication. Recycling essentials for space crew support is conducted in the Regenerative Life Support and the Hybrid Regenerative Water Recovery test beds. Two-phase fluid flow simulated under low-gravity conditions, hypervelocity particle impact on open mesh bumpers, and microcalorimetry to measure the long-term hydrazine/material compatibility were investigated. A patent application was made on a shape-memory-alloy release nut. Computer estimate of crew accommodations for advanced concepts was demonstrated. Training techniques were evaluated using multimedia and virtual environment. Upgrades of an electronic still camera provide high resolution images from orbit are presented.

Jenkins, Lyle↗

Fluid phase analyzer Patent

Mixed liquid and vapor phase analyzer design with thermocouples for relative heat transfer measurement

Hays, L. G.↗

Fluid core size of Mars from detection of the solar tide

The solar tidal deformation of Mars, measured by its k2 potential Love number, has been obtained from an analysis of Mars Global Surveyor radio tracking. The observed k2 of 0.153 +/- 0.017 is large enough to rule out a solid iron core and so indicates that at least the outer part of the core is liquid. The inferred core radius is between 1520 and 1840 kilometers and is independent of many interior properties, although partial melt of the mantle is one factor that could reduce core size. Ice-cap mass changes can be deduced from the seasonal variations in air pressure and the odd gravity harmonic J3, given knowledge of cap mass distribution with latitude. The south cap seasonal mass change is about 30 to 40% larger than that of the north cap.

Mars↗

Direct indication of particle size in fluidized beds

Differential pressure measurements indicate particle size and particle size distribution in fluidized beds. The technique is based on the relationship between bed particle size and the intensity and frequency of fluctuations. By measuring the fluctuations, an estimate of average particle size of the fluid-bed material can be made.

Knudsen, I. E.↗

Frequency response studies for a wedge probe in viscoelastic fluids.

Investigation of a hot-film wedge probe in viscoelastic fluids by imposing on the probe a sinusoidal vibration of known amplitude and frequency. Root-mean-square (rms) velocities calculated from the displacement of the probe are compared to rms velocities obtained with a constant temperature anemometer. The tests were performed under turbulent flow conditions and also at flow rates where viscoelastic effects, i.e., decrease of heat transfer rates from the probe to the fluid and drag reduction, were observed. The experimental technique was established by measuring the response of the probe in mineral oil.

Rodriguez, J. M.↗

Selected technology for the gas industry

A number of papers were presented at a conference concerned with the application of technical topics from aerospace activities for the gas industry. The following subjects were covered: general future of fossil fuels in America, exploration for fossil and nuclear fuels from orbital altitudes, technology for liquefied gas, safety considerations relative to fires, explosions, and detonations, gas turbomachinery technology, fluid properties, fluid flow, and heat transfer, NASA information and documentation systems, instrumentation and measurement, materials and life prediction, reliability and quality assurance, and advanced energy systems (including synthetic fuels, energy storage, solar energy, and wind energy).

Source record↗

Application of luciferase assay for ATP to antimicrobial drug susceptibility

The susceptibility of bacteria, particularly those derived from body fluids, to antimicrobial agents is determined in terms of an ATP index measured by culturing a bacterium in a growth medium. The amount of ATP is assayed in a sample of the cultured bacterium by measuring the amount of luminescent light emitted when the bacterial ATP is reacted with a luciferase-luciferin mixture. The sample of the cultured bacterium is subjected to an antibiotic agent. The amount of bacterial adenosine triphosphate is assayed after treatment with the antibiotic by measuring the luminescent light resulting from the reaction. The ATP index is determined from the values obtained from the assay procedures.

Chappelle, E. W.↗

A prioritized set of physiological measurements for future spaceflight experiments

A set of desired experimental measurements to be obtained in future spaceflights in four areas of physiological investigation are identified. The basis for identifying the measurements was the physiological systems analysis performed on Skylab data and related ground-based studies. An approach for prioritizing the measurement list is identified and discussed with the use of examples. A prioritized measurement list is presented for each of the following areas; cardiopulmonary, fluid-renal and electrolyte, hematology and immunology, and musculoskeletal. Also included is a list of interacting stresses and other factors present in spaceflight experiments whose effects may need to be quantified.

Source record↗

Improved sample management in the cylindrical-tube microelectrophoresis method

A modification to an analytical microelectrophoresis system is described that improves the manipulation of the sample particles and fluid. The apparatus modification and improved operational procedure should yield more accurate measurements of particle mobilities and permit less skilled operators to use the apparatus.

Smolka, A. J. K.↗