Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Evidence of toroidally localized turbulence with applied 3D fields in the DIII-D tokamak

New evidence indicates that there is significant 3D variation in density fluctuations near the boundary of weakly 3D tokamak plasmas when resonant magnetic perturbations are applied to suppress transient edge instabilities. The increase in fluctuations is concomitant with an increase in the measured density gradient, suggesting that this toroidally localized gradient increase could be a mechanism for turbulence destabilization in localized flux tubes. Two-fluid magnetohydrodynamic simulations find that, although changes to the magnetic field topology are small, there is a significant 3D variation of the density gradient within the flux surfaces that is extended along field lines. This modeling agrees qualitatively with the measurements. The observed gradient and fluctuation asymmetries are proposed as a mechanism by which global profile gradients in the pedestal could be relaxed due to a local change in the 3D equilibrium. In conclusion, these processes may play an important role in pedestal and scrape-off layer transport in ITER and other future tokamak devices with small applied 3D fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chemical and isotopic evolution of flowback fluids from the Utica Gas Shale Play, Eastern Ohio USA

For this work, hydraulic fracturing flowback fluids were collected from two Utica/Point Pleasant well pads in eastern Ohio. One site was in the wet gas zone (UPPW), while the site ~50 km south consisted of four wells on the same pad in the dry gas zone (UPPS). Samples of input fluids also were collected before and during hydraulic fracturing. Flowback fluids are Na-Ca-Cl brines with total dissolved salt (TDS) concentrations that increase over several months from ~100 to 200 g/L. The slightly higher TDS of the dry gas fluids are in part due to recycled flowback used as input fluids, and in part due to lower volume of water used in hydraulic fracturing. Concentrations of most major ions (Ca 2+ , Mg 2+ , Na + , Sr2 + , Fe, Mn, Cl – , Br – ) are similar for the five wells sampled, although small but systematic changes occur in the major element ratios over time. Most notably, an increase in the Sr/Cl ratio corresponds to an increase in the 87 Sr/ 86 Sr ratio in the fluids, suggesting interactions with a more radiogenic Sr source in the subsurface. Dissolved Ba concentrations and Ra activities were different between the two sites, reflecting a high SO 4 2– fluid used at the UPPW site, and water-rock reactions occurring during hydraulic fracturing at the UPPS site. Water oxygen (δ 18 O) and hydrogen (δD) isotopes for input fluids used in the UPPW4 well and fresh water used for the UPPS wells fall on the Global Meteoric waterline (GMWL). Flowback fluids from both sites are relatively enriched in δ 18 O and δD compared to the input, but do not appear to follow a simple mixing trend, suggesting reaction and isotopic exchange with carbonates and fractionation due to imbibition in the rock. Cl isotopes, δ 37 Cl in the FP fluids varied from ~ –0.43 to +0.13‰, the largest variation was observed in the earlier stages of flowback, while in the later stages δ 37 Cl exhibited a small but systematic increase over time, suggesting diffusion control of isotopic composition. Some of the trace species measured (dissolved Fe, Mn, thiosulfate and organic acids) do not follow the same trends as the major ions, suggesting contributions from input fluids, or microbially mediated reactions are exerting control on their concentrations. Input water chemistry exerts an important control on the Sr and Ba concentrations in flowback water. High SO 4 2– in the input fluids used for hydraulically fracturing the wet gas well leads to precipitation of barite-celestite in flowback fluids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inflow Characterization for Marine and Hydrokinetic Energy Devices. FY-2011: Annual Progress Report

The Pacific Northwest National Laboratory (PNNL), in collaboration with the Applied Physics Laboratory at the University of Washington (APL-UW), has carried out a detailed preliminary fluid flow field study at site selected for testing of marine and hydrokinetic turbines using Acoustic Doppler Velocimetry (ADV) measurements, Acoustic Doppler Current Profiler (ADCP) measurements, and Conductivity, Temperature and Depth (CTD) measurements. In FY-2011 these measurements were performed continuously for two weeks, in order to collect data during neap and spring tides, as well as during diurnal tidal variations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On Lorentz invariants in relativistic magnetic reconnection

Lorentz invariants whose nonrelativistic correspondences play important roles in magnetic reconnection are discussed in this paper. Particularly, the relativistic invariant of the magnetic reconnection rate is defined and investigated in a covariant two-fluid model. Certain Lorentz covariant representations for energy conversion and magnetic structures in reconnection processes are also investigated. Furthermore, relativistic measures for topological features of reconnection sites, particularly magnetic nulls and separatrices, are analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of dissolved salts on two-phase flow and boiling heat transfer in a natural circulation loop

Two-phase natural circulation and boiling experiments are conducted in this study with artificial seawater as a heat transfer fluid or process coolant. This experimental work is focused on understanding the role of dissolved salts in water on the steady state two-phase natural circulation flow rates. Mass flow rates were measured at different heat flux levels with artificial seawater, deionized water and tap water in the experimental loop. It was found that the average quasi-steady state mass flow rates were the same at any particular heat flux level regardless of the fluid being used. Artificial seawater coolant exhibited more stable natural circulation at higher heat flux as compared to the other two coolants. Mass flow measurements recorded at 2 s intervals show that magnitude of flow oscillations are much higher in case of tap water and deionized water. Also, high speed camera images revealed that the bubble departure diameters are smaller in seawater compared to tap or deionized water. This can be attributed to the increased local wettability due to the presence of dissolved salts in the fluid. Visual observations of the riser section showed that bubble coalescence and formation of slugs is inhibited in the seawater. These observations also explain the reduced pressure drop across test section when seawater was used as a coolant.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The shallow water equations as a hybrid flow model for the numerical and experimental analysis of hydro power stations

The numerical analysis of hydro power stations is an important method of the hydraulic design and is used for the development and optimisation of hydro power stations in addition to the experiments with the physical submodel of a full model in the hydraulic laboratory. For the numerical analysis, 2D and 3D models are appropriate and commonly used.The 2D models refer mainly to the shallow water equations (SWE), since for this flow model a large experience on a wide field of applications for the flow analysis of numerous problems in hydraulic engineering already exists. Often, the flow model is verified by in situ measurements. In order to consider 3D flow phenomena close to singularities like weirs, hydro power stations etc. the development of a hybrid fluid model is advantageous to improve the quality and significance of the global model. Here, an extended hybrid flow model based on the principle of the SWE is presented. The hybrid flow model directly links the numerical model with the experimental data, which may originate from physical full models, physical submodels and in-situ measurements. Hence a wide field of application of the hybrid model emerges including the improvement of numerical models and the strong coupling of numerical and experimental analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NON-NEWTONIAN FLUID CAVERN AND NEWTONIAN CLOUD HEIGHT TESTS TO CHARACTERIZE PULSE JET MIXER OPERATION

Pulse jet mixing systems are being developed for use in the Waste Treatment Plant in Washington State. To assist with system development, scaled tests were conducted to obtain experimental measurements of the cloud height for Newtonian slurries and cavern heights for a Non-Newtonian yield stress material. The measurements were required to assess the effective mixing and material mobilization produced during pulse jet mixer operation. The cloud height measurements were obtained for a single steady-state jet directed downward in a spherical-bottom tank. The cloud tests used glass beads in water to evaluate the height of the suspended slurry as a function of jet velocity. Cloud testing revealed that the glass bead material was suspended in the tank quickly and developed a distinctive height for each combination of flow rate and particulate size tested. The solids loading had minimal impact on the cloud height for a given particle size. During all cloud tests, the surface of the tank remained relatively calm, indicating that the slurry was dissipating the mixing energy of the relatively high velocity jet. Cavern tests were conducted to obtain experimental data of non-Newtonian fluid mixing for fluid properties similar to those of certain tank wastes. A transparent material that exhibited a yield stress and shear thinning behavior was used to obtain measurements of steady-state cavern heights as a function of jet velocity. For the non-Newtonian fluid cavern tests, distinct cavern volumes were readily developed for the four velocities tested. A linear relationship was observed to exist between cavern height and nozzle velocity. Since the experimental work detailed in this paper was completed, additional scaled tests have been conducted with pneumatic drive systems and direct drive systems similar to that described for this effort. Data from both types of measurements are shown to be linear; however, effects from the reciprocating drive systems that are not yet incorporated into models may be affecting the ability to collapse this data independent of scale. It is recommended that future efforts to assess performance of PJM operations using scaled tests consider employing direct drive systems to aid in evaluating scaling trends. A test system can be configured to allow testing at both reciprocating and direct drive conditions; thereby allowing direct comparison between them.

cloud height tests↗

Optimization of in-line phase contrast particle image velocimetry using a laboratory x-ray source

Phase contrast particle image velocimetry (PIV) using a laboratory x-ray microfocus source is investigated using a numerical model. Phase contrast images of 75 {mu}m air bubbles, embedded within water exhibiting steady-state vortical flow, are generated under the paraxial approximation using a tungsten x-ray spectrum at 30 kVp. Propagation-based x-ray phase-contrast speckle images at a range of source-object and object-detector distances are generated, and used as input into a simulated PIV measurement. The effects of source-size-induced penumbral blurring, together with the finite dynamic range of the detector, are accounted for in the simulation. The PIV measurement procedure involves using the cross-correlation between temporally sequential speckle images to estimate the transverse displacement field for the fluid. The global error in the PIV reconstruction, for the set of simulations that was performed, suggests that geometric magnification is the key parameter for designing a laboratory-based x-ray phase-contrast PIV system. For the modeled system, x-ray phase-contrast PIV data measurement can be optimized to obtain low error (<0.2 effective pixel of the detector) in the system with magnification lying in the range between 1.5 and 3. For large effective pixel size (>15 {mu}m) of the detector, high geometric magnification (>2.5) is desired, while for large source size system (FWHM > 30 {mu}m), low magnification (<1.5) would be suggested instead. The methods developed in this paper can be applied to optimizing phase-contrast velocimetry using a variety of laboratory x-ray sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geophysical borehole logging data of wells ER-GLS1, ER-GUM1, ER-PLM7, and ER-PLM8 at the East River Watershed, Colorado

The purpose of this data set is to provide a means of characterizing the bedrock variability both within a single borehole location and across the East River Watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States, and all boreholes are located within Mancos shale bedrock. The data set contains geophysical borehole logging data acquired in October 2018 in boreholes ER-GUM1 (East River- Gothic Upper Montane Borehole #1) and ER-GLS1 (East River- Gothic Lower Subalpine Borehole #1), and acquired in October 2019 in boreholes ER-PLM7 (East River- Pumphouse Lower Montane Borehole #7) and ER-PLM8 (East River- Pumphouse Lower Montane Borehole #8). It contains depth, natural gamma ray emission, spectral gamma ray emission(Th, K, U), magnetic susceptibility, fluid temperature and electrical conductivity, electromagnetic (EM) induction derived rock electrical resistivity, heat pulse and spinner flow measurements to estimate groundwater flow, and Nuclear Magnetic Resonance (NMR) derived water content and hydraulic conductivity. Data for each borehole are provided as comma delimited text files. For each borehole accurate location information is provided (based on RTK GPS (Real Time Kinematic Global Positioning System) surveying). Borehole logging data were acquired using Mount Sopris borehole tools, and Vista Clara Javelin for NMR data.

54 ENVIRONMENTAL SCIENCES↗

Measurements and non-local thermodynamic equilibrium modeling of mid-Z plasma emission

The x-ray yields from laser-irradiated thin foils of iron, copper, zinc, and germanium have been measured in the soft and multi-keV x-ray ranges at the OMEGA laser at the Laboratory for Laser Energetics. The incident laser power had a pre-pulse to enhance the x-ray emission of a 1 ns flat-top main pulse. The experimental results have been compared with post-shot simulations performed with the two-dimensional radiation-hydrodynamics code FCI2. A new non-local thermodynamic equilibrium model, NOO-RAD, have been incorporated into FCI2. In this approach, the plasma ionization state is in-line calculated by the atomic physics NOHEL package. In the soft x-ray bands, both simulations using RADIOM [M. Busquet, Phys. Fluids B 5, 4191 (1993)] and NOO-RAD clearly over-predict the powers and energies measured by a broad-band spectrometer. In one case (the iron foil), the discrepancy between the measured and simulated x-ray output is nevertheless significantly reduced when NOO-RAD is used in the simulations. In the multi-keV x-ray bands, the simulations display a strong sensitivity to the coupling between the electron thermal conductivity and the NLTE models, and for some particular combinations of these, provide a close match to the measured emission. The comparison between the measured and simulated H-like to He-like line-intensity ratios deduced from high-resolution spectra indicates higher experimental electron temperatures were achieved, compared to the simulated ones. Measurements of the plasma conditions have been achieved using the Thomson-scattering diagnostic. The electron temperatures are found to range from 3 to 5 keV at the end of the laser pulse and are greater than predicted by the simulations. The measured flow velocities are in reasonable agreement with the calculated ones. This last finding gives us confidence in our numerical predictions for the plasma parameters, which are over that time mainly determined by hydrodynamics, such as the mass densities and the ion temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the central slice. Regardless of phantom material or filled fluid density, dose delivered by the saddle scan was negligibly different than the simple circular, no-tilt scans. The average dose measured in the breast phantom was marginally higher for saddle than the circular no tilt scan at 3.82 and 3.87 mGy, respectively. Conclusions: Not only does nontraditional 3D-trajectory CT scanning yield more complete sampling of the breast volume but also has comparable dose deposition throughout the breast and anterior chest volume, as verified by Monte Carlo simulation and physical measurements.

60 APPLIED LIFE SCIENCES↗

Is Radioactive Tank Waste a Bingham Fluid?

Slurries and sludges across the United States Department of Energy (DOE) complex rank among the most rheologically interesting. Their composition is heterogeneous, spanning a very broad range of particle sizes, densities, and interparticle forces. All exhibit shear thinning, some have yield stresses, and many are thixotropic. Despite the variety, these complex fluids are often represented using the historic Bingham fluid model, which fits higher shear rate data to a simple straight line. The intercept provides a yield stress, which has been a key design parameter in construction of large-scale waste processing facilities. However, many radioactive wastes are simply not Bingham fluids, which extrapolate but poorly across low to intermediate shear rates that are characteristic of typical processing conditions. Indeed, processing shear rates as high as 200 1/s, which has been a typical minimum shear rate used in fitting, are seldom encountered in nuclear waste processing. Therefore, more realistic rheological models are necessary to accurately predict waste processing performance. PNNL recently re-evaluated the rheology of reconstituted Hanford REDOX sludge waste against a wide variety of rheological models including the Bingham, Cross, Cross with yield stress, Carreau, biviscous, Herschel-Bulkley (which includes a power law dependence), Casson, and Gay models. They found that all of the models provided a closer fit than the Bingham model and that the biviscous model and Cross with yield stress model were convincing. However, reconstituted Hanford REDOX sludge waste is but one type of DOE waste and a direct contrast and comparison of these three models against undiluted, unmixed tank waste (actual not simulant) has not been performed previously. Therefore, the purpose of this paper is to evaluate the rheology of actual tank waste with these more accurate rheological models. In this paper, we evaluate select rheological data for slurry samples from Hanford’s AZ-101, AZ-102, and SY-101 waste tanks. In each of these cases, we find that Cross’ model with yield stress and the biviscous model significantly outperform the Bingham fluid model. Furthermore, the AZ-101 data also shows that the shear stress peak that startup significantly exceeds the Bingham yield stress, which is commonly observed in the incipient moments of rheological measurements on simulants. In contrast, Cross’ model may empirically accommodate an initial spike in shear stress at modest shear rates. These are important observations because computational and analytical fluid dynamics simulations rely on rheological constitutive models for accurately and conservatively predict waste processing performance. These findings suggest the need for better rheological modeling of and validation against radioactive waste.

Rheology, Radioactive Waste↗

Shear-Induced Anisotropy of Concentrated Multi-walled Carbon Nanotube Suspensions Using X-ray Scattering

X-ray scattering is used to measure particle orientation in concentrated multiwalled carbon nanotube (MWNT) suspensions under shear flow. MWNTs were dispersed in a Newtonian suspending fluid (uncured epoxy). The dispersions exhibit shear thinning, approaching the matrix viscosity at high shear rates. This is accompanied by progressive development of MWNT orientation along the flow direction with increasing shear rate. The impact of MWNT aspect ratio and concentration on steady-state orientation is explored. In one sample (2 wt. % dispersion of short MWNTs), orientation was measured in both the flow-gradient (1-2) and flow-vorticity (1-3) planes of shear flow to provide a more complete picture of the three-dimensional orientation state. Also in this sample, 1-3 plane measurements were conducted using both small- and wide-angle x-ray scattering (SAXS and WAXS). While the two methods produce qualitatively similar results, WAXS-derived measures of flow-induced anisotropy are consistently larger than SAXS data. In transient measurements following step-down in shear rate, MWNT orientation is found to decrease on similar time scales as viscosity increases. Prolonged growth of storage modulus is observed following flow cessation, accompanied by an unexpectedly rapid partial loss of MWNT orientation. The rheological and orientation data are discussed in terms of distortion, breakdown, and reformation of percolated MWNT networks in these samples.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Evaluation of Shot-to-Shot In-Nozzle Flow Variations in a Heavy-Duty Diesel Injector Using Real Nozzle Geometry

Cyclic variability in internal combustion engines (ICEs) arises from multiple concurrent sources, many of which remain to be fully understood and controlled. This variability can, in turn, affect the behavior of the engine resulting in undesirable deviations from the expected operating conditions and performance. Shot-to-shot variation during the fuel injection process is strongly suspected of being a source of cyclic variability. This study focuses on the shot-to-shot variability of injector needle motion and its influence on the internal nozzle flow behavior using diesel fuel. High-speed x-ray imaging techniques have been used to extract high-resolution injector geometry images of the sac, orifices, and needle tip that allowed the true dynamics of the needle motion to emerge. These measurements showed high repeatability in the needle lift profile across multiple injection events, while the needle radial displacement was characterized by a much higher degree of randomness. A robust and previously validated computational setup from the authors’ research group using a commercial computational fluid dynamics (CFD) code has been adapted for the eight-hole heavy-duty common-rail diesel injector used for the measurements. The simulation results obtained using the x-ray-scanned geometry have been validated against available experimental data of mass flow rate at the nozzle exit. The fuel mass flow rate has then been analyzed at three different injection pressures that cover the conditions at which the injector typically operates during normal engine operation. Finally, the average off-axis motion of the needle has been perturbed (based on the variability found in the experimental measurements) to generate three new cases that present different amplitude and phasing of the radial displacement with respect to the baseline average motion. Furthermore, this revealed the effects of off-axis motion on shot-to-shot and orifice-to-orifice variations.

42 ENGINEERING↗

2012 SRNL-EM Vane Rheology Results

The vane method has been shown to be an effective tool in measuring the yield stress of both settled and mixed slurries in laboratory bench scale conditions in supporting assessments of both actual and simulant waste slurries. The vane has also been used to characterize dry powders and granular solids, the effect of non-cohesive solids with interstitial fluids and used as a guide to determine if slip is present in the geometries typically used to perform rheological flow curve measurements. The vane has been extensively characterized for measuring the shear strength in soils in both field and laboratory studies. The objectives for this task are: Fabricate vane instrument; Bench top testing to further characterize the effect of cohesive, non-cohesive, and blends of cohesive/non-cohesive simple simulants; Data from measurement of homogenized and settled bed of Kaolin sludge and assessment of the technology. In this document, the assessment using bench scale measurements of non-cohesive materials (beads) and cohesive materials (kaolin) is discussed. The non-cohesive materials include various size beads and the vane was assessed for depth and deaeration (or packing) via tapping measurements. For the cohesive (or non-Newtonian) materials, flow curves and yield stress measurements are performed using the vane and this data is compared to the traditional concentric cylinder flow curve measurement. Finally, a large scale vane was designed, fabricated, and tested with the cohesive (or non-Newtonian) materials to determine how a larger vane performs in measuring the yield stress and flow curve of settled cohesive solids.

47 OTHER INSTRUMENTATION↗

Probabilistic geomechanical analysis of compartmentalization at the Snøhvit CO 2 sequestration project

Abstract Pressure buildup caused by large‐scale CO 2 injection is a key concern during a carbon sequestration project. Large overpressures can compromise seal integrity, reactivate faults, and induce seismicity. Furthermore, pressure buildup is directly related with storage capacity. In this work we study the geomechanical response to CO 2 injection at Snøhvit, to understand the potential for fault reactivation, leakage, and contamination of the producing interval through bounding faults. Furthermore, we evaluate the potential contribution of a structural component to reservoir compartmentalization. We combine simplified analytical models, based on critically stressed fracture theory and a Mohr‐Coulomb failure criterion, with a rigorous sensitivity analysis. Large stress uncertainties are present and reflected in the modeling results. It was found that under the most likely stress state the faults are fairly stable and caprock hydrofracturing would be expected before fault reactivation. In most of the analyzed cases, the critical pressure perturbation needed for reactivation is above 13 MPa, which was the limiting pressure increase before reaching the fracture pressure. Faults were found to be ~ 20% less stable when considering variations in S Hmax orientation. In those cases, fault reactivation could be expected before caprock failure if injection continued. However, if the pressure increase did reach the critical values for seal failure estimated under the worst case (and least likely) stress state, no indication of such failure can be observed in the measured pressure response. Finally, the potential role of a structural component in the compartmentalization and fluid migration is difficult to assess due to the stress state uncertainty.

Chiaramonte, Laura↗

A micro-jet array for economic intensification of gas transfer in bioreactors

Bioreactors are of interest for gas-to-liquid conversion of stranded or waste industrial gases, such as CO, CH 4 , or syngas. Process economics requires reduction of bioreactor cost and size while maintaining intense production via rapid delivery of gases to the liquid phase (i.e., high k L a). Here, we show a novel bioreactor design that outperforms all known technology in terms of gas transfer energy efficiency (k L a per power density) while operating at high k L a (i.e., near 0.8 s -1 ). The reactor design uses a micro-jet array to break feedstock gas into a downward microbubble flow. Hydrodynamic and surfactant measurements show the reactor's advanced performance arises from its bubble breakage mechanism, which limits fluid shear to a thin plane located at an optimal location for bubble breakage. Power dissipation and k L are shown to scale with micro-jet diameter rather than reactor diameter, and the micro-jet array achieves improved performance compared to classical impinging-jets, ejector, or U-loop reactors. Additionally, the hydrodynamic mechanism by which the micro-jets break bubbles apart is shown to be shearing the bubbles into filaments then fragmentation by surface tension rather than “cutting in half” of bubbles. Guided by these hydrodynamic insights, strategies for industrial design are given.

09 BIOMASS FUELS↗

Reconciling large- and small-scale structure in Twin Higgs models

Here, we study possible extensions of the Twin Higgs model that solve the Hierarchy problem and simultaneously address problems of the large- and small-scale structures of the Universe. Besides naturally providing dark matter (DM) candidates as the lightest charged twin fermions, the twin sector contains a light photon and neutrinos, which can modify structure formation relative to the prediction from the ΛCDM paradigm. We focus on two viable scenarios. First, we study a Fraternal Twin Higgs model in which the spin-3/2 baryon $\hat{Ω}$~($\hat{b}$$\hat{b}$$\hat{b}$) and the lepton twin tau $\hat{τ}$ contribute to the dominant and subcomponent dark matter densities. A non-decoupled scattering between the twin tau and twin neutrino arising from a gauged twin lepton number symmetry provides a drag force that damps the density inhomogeneity of a dark matter subcomponent. Next, we consider the possibility of introducing a twin hydrogen atom $\hat{H}$ as the dominant DM component. After recombination, a small fraction of the twin protons and leptons remains ionized during structure formation, and their scattering to twin neutrinos through a gauged U(1) B-L force provides the mechanism that damps the density inhomogeneity. Both scenarios realize the Partially Acoustic dark matter (PAcDM) scenario and explain the σ 8 discrepancy between the CMB and weak lensing results. Moreover, the self-scattering neutrino behaves as a dark fluid that enhances the size of the Hubble rate H 0 to accommodate the local measurement result while satisfying the CMB constraint. For the small-scale structure, the scattering of $\hat{Ω}$ ’s and $\hat{H}$’s through the twin photon exchange generates a self-interacting dark matter (SIDM) model that solves the mass deficit problem from dwarf galaxy to galaxy cluster scales. Furthermore, when varying general choices of the twin photon coupling, bounds from the dwarf galaxy and the cluster merger observations can set an upper limit on the twin electric coupling.

79 ASTRONOMY AND ASTROPHYSICS↗