Search NASA⌕ Search

SEARCH · Search NASA

Results for “Failure Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Long-term Outcomes and Quality of Life of 186 Patients With Primary Parotid Carcinoma Treated With Surgery and Radiotherapy at the Daniel den Hoed Cancer Center

Purpose: To assess the outcomes, toxicity, and quality of life (QOL) of patients with primary parotid carcinoma treated with surgery and postoperative radiotherapy at the Daniel den Hoed Cancer Center. Methods and Materials: Between 1995 and 2010, 186 patients with parotid carcinoma were treated with parotidectomy with or without neck dissection, followed by radiotherapy. Elective nodal irradiation (ENI) was applied to high-risk, node-negative disease. End points were locoregional control (LRC), disease-free survival (DFS), cause-specific survival (CSS), and overall survival (OS), late toxicity, and QOL. Results: After a median follow-up of 58 months (range, 4-172 months), the 5-year Kaplan-Meier estimates for LRC, DFS, CSS, and OS were 89%, 83%, 80%, and 68%, respectively. Forty-five events were reported: 24 distant metastases (DM) and 21 locoregional failures (LRF). Event-free survival rates by histological types were 89%, 78%, 76%, 74%, and 70% for acinic cell, mucoepidermoid, adenoid cystic, adenocarcinoma, and squamous cell carcinoma, respectively. More LRF were reported in patients with squamous cell and high-grade mucoepidermoid carcinoma (21% and 19%, respectively) than in patients with other histological types (p = 0.04) and more DM in patients with adenoid cystic and adenocarcinoma (20% and 19%, respectively) than in patients with other types (p = 0.03). None of the high-risk node-negative patients who received ENI developed regional failure. On multivariate analysis, T stage, N stage, grade, and presence of perineural invasion and facial paralysis correlated significantly with DFS. The 5-year cumulative incidence of grade {>=}2 late toxicity was 8%. QOL scores deteriorate during and shortly after treatment but returned in almost all scales to baseline scores within 6 months. Conclusions: Of the entire group, surgery and postoperative radiotherapy resulted in excellent outcomes with minimal side effects and preservation of good QOL scores. However, in view of the pattern of failures observed in this study, the role of adjuvant systemic or targeted therapy in patients at high risk of DM should be investigated in prospective trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Peripherally Placed Totally Implantable Venous-access Port Systems of the Forearm: Clinical Experience in 763 Consecutive Patients

The aim of this study is to evaluate the effectiveness and safety of percutaneously placed totally implantable venous-access ports (TIVAPs) of the forearm. Between January 2006 and October 2008, peripheral TIVAPs were implanted in 763 consecutive patients by ultrasound and fluoroscopic guidance. All catheters were implanted under local anesthesia and were tunneled subcutaneously. Indication, technical success, and complications were retrospectively analyzed according to Society of Interventional Radiology (SIR) criteria. Presence of antibiotic prophylaxis, periprocedurally administered drugs (e.g., sedation), and laboratory results at the time of implantation were analyzed. Maintenance during the service interval was evaluated. In total, 327,499 catheter-days were analyzed. Technical success rate was 99.3%. Reasons for initial failure of implantation were either unexpected thrombosis of the subclavian vein, expanding tumor mass of the mediastinum, or failure of peripheral venous access due to fragile vessels. Mean follow-up was 430 days. There were 115 complications observed (15.1%, 0.03 per 100 catheter-days), of which 33 (4.3%) were classified as early (within 30 days from implantation) and 82 (10.7%) as late. Catheter-related venous thrombosis was found in 65 (8.5%) of 763 (0.02 per 100 catheter-days) TIVAPs. Infections were observed in 41 (5.4%) of 763 (0.01 per 100 catheter-days) devices. Other complications observed included dislocation of the catheter tip (0.8%), occlusion (0.1%), or rupture (0.1%) of the port catheter. Dislocated catheters were corrected during a second interventional procedure. In conclusion, implantation of percutaneously placed peripheral TIVAPs shows a high technical success rate and low risk of early complications when ultrasound and fluoroscopic guidance are used. Late complications are observed three times as often as early complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Failure for Rhabdomyosarcoma of the Perineal and Perianal Region

Purpose: To analyze prognostic factors and patterns of failure for rhabdomyosarcoma of the perineal and perianal region (PRMS), with an emphasis on radiation therapy for locoregional control. Methods and Materials: Detailed records of all 14 patients treated for PRMS at Memorial Sloan-Kettering Cancer Center between 1998 and 2012 were reviewed. The Kaplan-Meier method was used to assess the event-free survival (EFS) and overall survival (OS), and a competing-risks analysis was used to assess the cumulative incidence of local, regional, and distant failures. Results: Median age was 15.8 years (range, 1.1-31.9 years). High-risk features were identified: 9 of 14 patients (64%) had group 3 disease and 3 of 14 (21%) had group 4; 11 of 14 tumors (78%) were alveolar; 12 of 14 tumors (86%) were ≥5 cm; and 9 of 14 patients (64%) had involved lymph nodes (N1). Of those aged ≥10 years at diagnosis, 9 of 10 (90%) had alveolar histology, all had tumors ≥5 cm, and 8 of 10 (80%) presented with N1 disease. The rates of local, regional, and distant failure at 5 years were 17%, 31%, and 52%, respectively. Although 3 of the 4 patients with regional failure received nodal irradiation, only one of the nodal failures occurred in the radiation therapy field. The 5-year EFS was 33%, and OS was 39%. Age ≥10 years was associated with poor outcomes: EFS was 13% in patients aged ≥10 years, compared with 75% in those aged <10 years (P=.04); the OS was 13% in patients aged ≥10 years, compared with 100% in those aged <10 years (P=.04). Conclusions: Patients with PRMS, especially those aged ≥10 years, present with poor prognostic features and continue to have poor outcomes. Given the high incidence of regional node recurrence, we recommend prophylactic ilioinguinal lymph node irradiation for all patients aged ≥10 years. For children aged <10 years, nodal evaluation is essential to determine the role for lymph node irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystal plasticity modeling and analysis for the transition from intergranular to transgranular failure in nickel-based alloy Inconel 740H at elevated temperature

The precipitation-strengthened Nickel alloy Inconel® 740H® (IN740H) exhibits increased ductility at higher applied strain rates during quasi-static tensile tests at an elevated temperature of 760°C. The examination of fracture surfaces in this context reveals a noteworthy transition of underlying fracture mechanisms from transgranular to intergranular fracture as the applied strain rate decreases from 1×10 -3 / s to 0.83×10 -4 / s . To thoroughly understand the mechanical response of IN740H under these conditions, this study develops a crystal plasticity finite element (CPFE) model. Further, this model incorporates various deformation mechanisms including dislocation slips, climb, and grain boundary sliding, which are relevant to the test conditions. The model is calibrated using data from both tensile tests at different strain rates and creep tests across a broad stress range at 760°C, enabling the accurate determination of model parameters for each mechanism. Simulation results well captured the experimental observations of different failure modes. At higher strain rates, the model shows a dominance of dislocation slip leading to heterogeneous plastic deformation and formation of transgranular shear bands causing the failure, while at lower strain rates, an increased activity of grain boundary sliding causes grain boundaries crack leading to intergranular failure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Angular-Rate Estimation Using Quaternion Measurements

In most spacecraft (SC) there is a need to know the SC angular rate. Precise angular rate is required for attitude determination, and a coarse rate is needed for attitude control damping. Classically, angular rate information is obtained from gyro measurements. These days, there is a tendency to build smaller, lighter and cheaper SC, therefore the inclination now is to do away with gyros and use other means and methods to determine the angular rate. The latter is also needed even in gyro equipped satellites when performing high rate maneuvers whose angular-rate is out of range of the on board gyros or in case of gyro failure. There are several ways to obtain the angular rate in a gyro-less SC. When the attitude is known, one can differentiate the attitude in whatever parameters it is given and use the kinematics equation that connects the derivative of the attitude with the satellite angular-rate and compute the latter. Since SC usually utilize vector measurements for attitude determination, the differentiation of the attitude introduces a considerable noise component in the computed angular-rate vector.

Azor, Ruth↗

Synchrotron X-ray nano computed tomography based simulation of stress evolution in LiMn 2 O 4 electrodes

Here in this study, synchrotron X-ray nano-computed tomography at Advanced Photon Source in Argonne National Laboratory has been employed to reconstruct real 3D active particle morphology of LiMn 2 O 4 (LMO) commonly used in lithium-ion batteries (LIBs). For the first time, carbon-doped binder domain (CBD) has been included in the electrode structure as a 108 nm thick uniform layer using image processing technique. With this unique model, stress generated inside four LMO particles with a uniform layer of CBD has been simulated, demonstrating its strong dependence on local morphology (surface concavity and convexity), and the mechanical properties of CBD such as Young’s modulus. Specifically, high levels of stress have been found in vicinity of particle’s center or near surface concave regions, however much lower than the material failure limits even after discharging at the rate as high as 5C. On the other hand, the stress inside CBD has reached its mechanical limits when discharged at 5C, suggesting that it can potentially lead to failure by plastic deformation. The findings in this study highlight the importance of modeling LIB active particles with CBD and its appropriate compositional design and development to prevent the loss of electrical connectivity of the active particles from the percolated solid network and power losses due to CBD failure.

25 ENERGY STORAGE↗

Preliminary Results From a Prospective Study Using Limited Margin Radiotherapy in Pediatric and Young Adult Patients With High-Grade Nonrhabdomyosarcoma Soft-Tissue Sarcoma

Purpose: To demonstrate the safety and efficacy of limited margin radiotherapy in the local control of pediatric and young adult patients with high-grade nonrhabdomyosarcoma soft tissue sarcoma (NRSTS). Methods and Materials: Pediatric patients with high-grade NRSTS requiring radiation were treated on an institutional review board approved prospective institutional study of conformal/intensity-modulated/interstitial brachytherapy using a 2-cm anatomically constrained margin. Results: A total of 32 patients (median age, 15.3 years; range, 2-22 years) received adjuvant (27 patients) or definitive (5 patients) irradiation. With a median follow-up of 32 months, the 3-year cumulative incidence of local failure was 3.7% for patients undergoing irradiation after surgical resection. Four patients experienced local failure; the mean dose to the volume of recurrence was >=97% of the prescribed dose. Conclusions: Delivery of limited margin radiotherapy using external beam or brachytherapy provides a high rate of local tumor control without marginal failure. Further follow-up is required to determine whether normal tissue effects are minimized using this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strong strain rate effect on the plasticity of amorphous silica nanowires

With electron-beam (e-beam) off, in-situ tensile experiments on amorphous silica nanowires (NWs) were performed inside a transmission electron microscope (TEM). By controlling the loading rates, the strain rate can be adjusted accurately in a wide range. The result shows a strong strain rate effect on the plasticity of amorphous silica NWs. At lower strain rate, the intrinsic brittle materials exhibit a pronounced elongation higher than 100% to failure with obvious necking near ambient temperature. At the strain rate higher than 5.23 × 10{sup −3}/s, the elongation of the NW decreased dramatically, and a brittle fracture feature behavior was revealed. This ductile feature of the amorphous silica NWs has been further confirmed with the in-situ experiments under optical microscopy while the effect of e-beam irradiation could be eliminated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Accumulation of collagen molecular unfolding is the mechanism of cyclic fatigue damage and failure in collagenous tissues

Overuse injuries to dense collagenous tissues are common, but their etiology is poorly understood. The predominant hypothesis that micro-damage accumulation exceeds the rate of biological repair is missing a mechanistic explanation. Here, we used collagen hybridizing peptides to measure collagen molecular damage during tendon cyclic fatigue loading and computational simulations to identify potential explanations for our findings. Our results revealed that triple-helical collagen denaturation accumulates with increasing cycles of fatigue loading, and damage is correlated with creep strain independent of the cyclic strain rate. Finite-element simulations demonstrated that biphasic fluid flow is a possible fascicle-level mechanism to explain the rate dependence of the number of cycles and time to failure. Molecular dynamics simulations demonstrated that triple-helical unfolding is rate dependent, revealing rate-dependent mechanisms at multiple length scales in the tissue. The accumulation of collagen molecular denaturation during cyclic loading provides a long-sought “micro-damage” mechanism for the development of overuse injuries.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of fiber inclination angle on bond-slip behavior of different alkali-activated composites under dynamic and quasi-static loadings

This study investigates the influence of inclination angle (0° and 45°) on the interfacial bond-slip behavior of macro steel fibers (straight, hooked end-deformed and length-deformed) and length-deformed polypropylene fibers reinforced in fly-ash and metakaolin based alkali-activated composites (AACs) under quasi-static and dynamic loadings. AACs demonstrate superior peak bond strength and toughness compared to cement composites regardless of fiber type and loading rate. Results also show that straight steel fiber exhibits a complete pullout in AACs. The amount of deformation of the fibers (deformation ratio) determined the failure type at different inclination angle and loading rate, thus governing the peak load and energy absorption. Depending on the fiber orientation, premature fiber rupture or matrix cracking is observed under dynamic loading in AACs due to matrix brittleness. The fiber failure modes in dynamic pullout are no different from those observed in the quasi-static pullout in AACs.

36 MATERIALS SCIENCE↗

Transfemoral Venous Access Facilitates Upper Extremity Dialysis Interventions: Procedural Success and Clinical Outcomes

Purpose: To report technical success and clinical outcomes of transfemoral venous access for upper extremity dialysis interventions. Materials and Methods: A total of 15 patients underwent a transfemoral venous approach for fistulography (n = 4; 27%) or thrombectomy (n = 11; 73%) over a 14-month period. Access characteristics, sheath size, thrombectomy method, angioplasty site, fluoroscopy time, radiation dose, technical and clinical success, complications, and post-intervention primary and secondary patency rates were recorded. Results: Access type included arteriovenous fistulas (n = 10; 67%) and grafts (n = 5; 33%). The most common configuration was brachio-brachial (n = 6; 38%). Mean age of access was 37 months. Mean prior interventions were 4. Right CFV access was used in all patients using 6–8-French (most common: 7-French [n = 10; 67%]) sheaths. Most thrombectomies (n = 11; 73%) required both pharmacologic and mechanical maceration (n = 9; 82%). All accesses required angioplasty to treat underlying stenosis at the outflow vein (n = 12; 80%) or arteriovenous anastomosis (n = 9; 90%). Mean fluoroscopy time was 26.43 min. Air kerma and dose area product were 178.06 ± 225.77 mGy and 57,768.83 ± 87,553.29 μGym{sup 2}, respectively. Procedural and clinical success rates were 93% and 80%, respectively. Technical failure was due to persistent stenosis in one patient. Clinical failure was due to unsuccessful dialysis immediately following intervention in three patients. Mean post-intervention primary patency and secondary patency durations were 2.8 and 4.8 months, respectively. Primary patency rates at 1 and 3 months were 50% and 35%, respectively. Secondary patency rates at 1 and 3 months were 58% and 30%, respectively. Conclusion: A transfemoral venous approach for intervention of upper extremity dialysis accesses may be a valuable adjunct to traditional approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion Exchange Technology Development in Support of the Urine Processor Assembly

The urine processor assembly (UPA) on the International Space Station (ISS) recovers water from urine via a vacuum distillation process. The distillation occurs in a rotating distillation assembly (DA) where the urine is heated and subjected to sub-ambient pressure. As water is removed, the original organics, salts, and minerals in the urine become more concentrated and result in urine brine. Eventually, water removal will concentrate the urine brine to super saturation of individual constituents, and precipitation occurs. Under typical UPA DA operating conditions, calcium sulfate or gypsum is the first chemical to precipitate in substantial quantity. During preflight testing with ground urine, the UPA achieved 85% water recovery without precipitation. However, on ISS, it is possible that crewmember urine can be significantly more concentrated relative to urine from ground donors. As a result, gypsum precipitated in the DA when operating at water recovery rates at or near 85%, causing the failure and subsequent re14 NASA Tech Briefs, September 2013 placement of the DA. Later investigations have demonstrated that an excess of calcium and sulfate will cause precipitation at water recovery rates greater than 70%. The source of the excess calcium is likely physiological in nature, via crewmembers' bone loss, while the excess sulfate is primarily due to the sulfuric acid component of the urine pretreatment. To prevent gypsum precipitation in the UPA, the Precipitation Prevention Project (PPP) team has focused on removing the calcium ion from pretreated urine, using ion exchange resins as calcium removal agents. The selectivity and effectiveness of ion exchange resins are determined by such factors as the mobility of the liquid phase through the polymer matrix, the density of functional groups, type of functional groups bound to the matrix, and the chemical characteristics of the liquid phase (pH, oxidation potential, and ionic strength). Previous experience with ion exchange resins has demonstrated that the most effective implementation for an ion exchange resin is a cartridge, or column, in which the resin is contained. Based on the results of equilibrium and sub-scale dynamic column testing, a possible solution for mitigating the calcium precipitation issue on the ISS has been identified. From an original pool of 13 ion exchange resins, two candidates have been identified that demonstrate substantial calcium removal on the sub-scale. The dramatic reduction in resin performance from published calcium uptake demonstrates the need for thorough evaluation of resins at the low pH and strong oxidizing environment present in the UPA. Chemical variations in the influent (calcium concentrations and pretreatment dosing) appear to have a noticeable impact on the calcium capacity of the resin. Low calcium concentrations and high pretreatment dosing will likely result in a decrease in calcium capacity. Conversely, low pre trea t - ment dosing will likely result in an increase in calcium capacity. In contrast, investigations at a variety of flow rates, length-to-diameter ratios, resin volumes, and flow regimes (continuous versus pulsed) show that changes in physical parameters do not have substantial impacts on resin performance in the very low specific velocity ranges of interest. This result is particularly useful because most commercial applications at higher specific velocities do show a relatively strong relationship between flow and capacity. The lack of a strong relationship will allow more flexibility in the implementation of an ion exchange bed for flight. Verification of subscale tests with flight-scale resin beds is recommended prior to implementation in the on-orbit UPA.

Mitchell, Julie↗

Sensor Data Quality and Angular Rate Down-Selection Algorithms on SLS EM-1

The NASA Space Launch System Block 1 launch vehicle is equipped with an Inertial Navigation System (INS) and multiple Rate Gyro Assemblies (RGA) that are used in the Guidance, Navigation, and Control (GN&C) algorithms. The INS provides the inertial position, velocity, and attitude of the vehicle along with both angular rate and specific force measurements. Additionally, multiple sets of co-located rate gyros supply angular rate data. The collection of angular rate data, taken along the launch vehicle, is used to separate out vehicle motion from flexible body dynamics. Since the system architecture uses redundant sensors, the capability was developed to evaluate the health (or validity) of the independent measurements. A suite of Sensor Data Quality (SDQ) algorithms is responsible for assessing the angular rate data from the redundant sensors. When failures are detected, SDQ will take the appropriate action and disqualify or remove faulted sensors from forward processing. Additionally, the SDQ algorithms contain logic for down-selecting the angular rate data used by the GN&C software from the set of healthy measurements. This paper provides an overview of the algorithms used for both fault-detection and measurement down selection.

Park, Thomas↗

Bending-induced Symmetry Breaking of Lithiation in Germanium Nanowires

From signal transduction of living cells to oxidation and corrosion of metals, mechanical stress intimately couples with chemical reactions, regulating these biological and physiochemical processes. The coupled effect is particularly evident in electrochemical lithiation/delithiation cycling of high-capacity electrodes, such as silicon (Si), where on one hand lithiation-generated stress mediates lithiation kinetics, and on the other electrochemical reaction rate regulates stress generation and mechanical failure of the electrodes. Here we report for the first time the evidence on the controlled lithiation in germanium nanowires (GeNWs) through external bending. Contrary to the symmetric core-shell lithiation in free-standing GeNWs, we show bending GeNWs breaks the lithiation symmetry, speeding up lithaition at the tensile side while slowing down at the compressive side of the GeNWs. The bending-induced symmetry breaking of lithiation in GeNWs is further corroborated by chemomechanical modeling. In the light of the coupled effect between lithiation kinetics and mechanical stress in the electrochemical cycling, our findings shed light on strain/stress engineering of durable high-rate electrodes and energy harvesting through mechanical motion.

Environmental Molecular Sciences Laboratory↗

High-throughput quantification of quasistatic, dynamic and spall strength of materials across 10 orders of strain rates

Abstract The response of metals and their microstructures under extreme dynamic conditions can be markedly different from that under quasistatic conditions. Traditionally, high strain rates and shock stresses are achieved using cumbersome and expensive methods such as the Kolsky bar or large spall experiments. These methods are low throughput and do not facilitate high-fidelity microstructure–property linkages. In this work, we combine two powerful small-scale testing methods, custom nanoindentation, and laser-driven microflyer (LDMF) shock, to measure the dynamic and spall strength of metals. The nanoindentation system is configured to test samples from quasistatic to dynamic strain-rate regimes. The LDMF shock system can test samples through impact loading, triggering spall failure. The model material used for testing is magnesium alloys, which are lightweight, possess high-specific strengths, and have historically been challenging to design and strengthen due to their mechanical anisotropy. We adopt two distinct microstructures, solutionized (no precipitates) and peak-aged (with precipitates) to demonstrate interesting upticks in strain-rate sensitivity and evolution of dynamic strength. At high shock-loading rates, we unravel an interesting paradigm where the spall strength vs. strain rate of these materials converges, but the failure mechanisms are markedly different. Peak aging, considered to be a standard method to strengthen metallic alloys, causes catastrophic failure, faring much worse than solutionized alloys. Our high-throughput testing framework not only quantifies strength but also teases out unexplored failure mechanisms at extreme strain rates, providing valuable insights for the rapid design and improvement of materials for extreme environments.

Eswarappa Prameela, Suhas (ORCID:0000000334530184)↗

Ground-Based Cryogenic Leak Test of Fittings for Cryogenic Fluid Management

Mechanically connected fluid joints are virtually unavoidable in complex cryogenic system designs. In the case of spacecraft, the performance of these joints is critical to mission success. This is especially true for long-duration space missions where even very low leak rates can eventually lead to significant propellant losses or failure of vital cryogenic cooling systems. NASA has recently undertaken an effort to quantify the leak rate of Vacuum Coupling Radiation (VCR) fittings over the temperature range from ambient to 20 K, both before and after exposure to a launch vibration profile. A test apparatus employing a cryocooler and a calibrated helium mass spectrometer was developed, validated, and used to obtain quantifiable leak rates at a fitting test pressure of 31 bar (450 psig). Three different fitting sizes were tested, 25.4 mm (¼ inch), 12.7 mm (½ inch), and 6.35 mm (1 inch) and two gasket materials, stainless steel, and silver-plated nickel. Each fitting configuration (size/seal material) was subjected to two consecutive cryogenic thermal cycles/measurement tests, followed by a launch vibration test profile at ambient temperature, and then two additional cryogenic thermal cycles/measurement tests. The design and development of the test apparatus, and test data are presented and discussed in detail.

G J Tamasy↗

Piloted Simulation Tests of Propulsion Control as Backup to Loss of Primary Flight Controls for a B747-400 Jet Transport

Partial failures of aircraft primary flight control systems and structural damages to aircraft during flight have led to catastrophic accidents with subsequent loss of lives (e.g. DC-10, B-747, C-5, B-52, and others). Following the DC-10 accident at Sioux City, Iowa in 1989, the National Transportation Safety Board recommended 'Encourage research and development of backup flight control systems for newly certified wide-body airplanes that utilize an alternate source of motive power separate from that source used for the conventional control system.' This report describes the concept of a propulsion controlled aircraft (PCA), discusses pilot controls, displays, and procedures; and presents the results of a PCA piloted simulation test and evaluation of the B747-400 airplane conducted at NASA Ames Research Center in December, 1996. The purpose of the test was to develop and evaluate propulsion control throughout the full flight envelope of the B747-400 including worst case scenarios of engine failures and out of trim moments. Pilot ratings of PCA performance ranged from adequate to satisfactory. PCA performed well in unusual attitude recoveries at 35,000 ft altitude, performed well in fully coupled ILS approaches, performed well in single engine failures, and performed well at aft cg. PCA performance was primarily limited by out-of-trim moments.

Bull, John↗

Androgen Suppression Combined with Elective Nodal and Dose Escalated Radiation Therapy (the ASCENDE-RT Trial): An Analysis of Survival Endpoints for a Randomized Trial Comparing a Low-Dose-Rate Brachytherapy Boost to a Dose-Escalated External Beam Boost for High- and Intermediate-risk Prostate Cancer

Purpose: To report the primary endpoint of biochemical progression-free survival (b-PFS) and secondary survival endpoints from ASCENDE-RT, a randomized trial comparing 2 methods of dose escalation for intermediate- and high-risk prostate cancer. Methods and Materials: ASCENDE-RT enrolled 398 men, with a median age of 68 years; 69% (n=276) had high-risk disease. After stratification by risk group, the subjects were randomized to a standard arm with 12 months of androgen deprivation therapy, pelvic irradiation to 46 Gy, followed by a dose-escalated external beam radiation therapy (DE-EBRT) boost to 78 Gy, or an experimental arm that substituted a low-dose-rate prostate brachytherapy (LDR-PB) boost. Of the 398 trial subjects, 200 were assigned to DE-EBRT boost and 198 to LDR-PB boost. The median follow-up was 6.5 years. Results: In an intent-to-treat analysis, men randomized to DE-EBRT were twice as likely to experience biochemical failure (multivariable analysis [MVA] hazard ratio [HR] 2.04; P=.004). The 5-, 7-, and 9-year Kaplan-Meier b-PFS estimates were 89%, 86%, and 83% for the LDR-PB boost versus 84%, 75%, and 62% for the DE-EBRT boost (log-rank P<.001). The LDR-PB boost benefited both intermediate- and high-risk patients. Because the b-PFS curves for the treatment arms diverge sharply after 4 years, the relative advantage of the LDR-PB should increase with longer follow-up. On MVA, the only variables correlated with reduced overall survival were age (MVA HR 1.06/y; P=.004) and biochemical failure (MVA HR 6.30; P<.001). Although biochemical failure was associated with increased mortality and randomization to DE-EBRT doubled the rate of biochemical failure, no significant overall survival difference was observed between the treatment arms (MVA HR 1.13; P=.62). Conclusions: Compared with 78 Gy EBRT, men randomized to the LDR-PB boost were twice as likely to be free of biochemical failure at a median follow-up of 6.5 years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗