Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Gradient Accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Development of a CW Superconducting RF Booster Cryomodule for Future Light Sources

Future light sources based on seeded free electron lasers (FEL) have the potential to increase the soft xray flux by several orders of magnitude with short bunch lengths to probe electron structure and dynamics. A low emittance, high rep-rate radio frequency (RF) photocathode electron gun will generate the electron beam that will require very stringent beam control and manipulation through the superconducting linear accelerator to maintain the high brightness required for an x-ray FEL. The initial or booster cavities of the superconducting radio frequency (SRF) linear accelerator will require stringent control of transverse kicks and higher order modes (HOM) during the beam manipulation and conditioning that is needed for emittance exchange and bunch compression. This SBIR proposal will develop, fabricate and test a continuous-wave SRF booster cryomodule specifically for this application. Phase I demonstrated the technical feasibility of the project by completing the preliminary SRF cavity and cryomodule design and its integration into an R&D test stand for beam studies at Lawrence Berkeley National Laboratory (LBNL). The five-cell bulk niobium cavities operate at 750 MHz, and generate 10 MV each with strong HOM damping and special care to eliminate transverse kicks due to couplers. Due to continuous-wave operation at fairly modest beam currents and accelerating gradients the complexity of the two cavity cryomodule is greatly reduced compared to an ILC type system. Phase II will finalize the design, and fabricate and test the booster cryomodule. The cryomodule consists of two five-cell cavities that will accelerate megahertz bunch trains with nano-coulomb charge. The accelerating gradient is a very modest 10 MV/m with peak surface fields of 20 MV/m and 42.6 mT. The cryogenic system operates at 2 K with a design dynamic load of 20 W and total required cryogenic capacity of 45 W. The average beam current of up to 1 mA corresponds to a beam power of 10 kW per 5- cell cavity and will require 20 kW of RF power for transmission, control and regulation. The RF power will be supplied by a commercial tetrode. Cryogenic tests will be carried out at LBNL to make use of their test facilities, cryogenics and laser systems, and for future use with beam. Demonstration of this new type of booster cryomodule will open many new applications of SRF linear accelerators.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observations of neutral depletion and plasma acceleration in a flowing high-power argon helicon plasma

Neutral depletion effects are observed in a steady-state flowing argon helicon plasma with a magnetic nozzle for high rf input powers (up to 3 kW). Noninvasive diagnostics including 105 GHz microwave interferometry and optical spectroscopy with collisional-radiative modeling are used to measure the electron density (n{sub e}), electron temperature (T{sub e}), and neutral density (n{sub n}). A region of weak neutral depletion is observed upstream of the antenna where increasing rf power leads to increased electron density (up to n{sub e}=1.6x10{sup 13} cm{sup -3}) while T{sub e} remains essentially constant and low (1.7-2.0 eV). The downstream region exhibits profound neutral depletion (maximum 92% line-averaged ionization), where T{sub e} rises linearly with increasing rf power (up to 4.9 eV) and n{sub e} remains constrained (below 6.5x10{sup 12} cm{sup -3}). Flux considerations indicate accelerated plasma flow (Mach 0.24) through the antenna region due to an axial pressure gradient with reduced collisional drag from neutral depletion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

22 GeV CEBAF with Novel Fixed Field Alternating Gradient Design

Extending the energy reach of CEBAF up to 22 GeV within the existing tunnel is being explored. Proposed energy upgrade can be achieved by increasing the number of recirculations, while using the existing CEBAF SRF cavity system. Presented scheme is based on an exciting new approach to acceleratie electrons efficiently with multiple passes in a single FFA beam line. Encouraged by recent success of the CBETA Test Accelerator, a proposal was formulated raise CEBAF energy by replacing the highest-energy arcs with Fixed Field Alternating Gradient (FFA) arcs. The new pair of arcs configured with FFA lattice would support simultaneous transport of additional 6 passes with energies spanning a factor of two, using the non-scaling FFA principle implemented with Halbach-derived permanent magnets - a novel magnet technology that significantly saves energy and lowers operating costs. One of the challenges of the multi-pass (11) linac optics is to provide uniform focusing in a vast range of energies, using fixed field lattice. Here, we propose a triplet lattice scaled up with increasing momentum along the linac. This would provide a stable periodic solution covering energy ratio of 1:33. The current CEBAF configured with a 123 MeV injector, makes optical matching in the first linac virtually impossible due to extremely high energy span ratio (1:175). Therefore, we envision replacement of the current injector with a 650 MeV 3-pass recirculating injector based on the existing LERF facility. Finally, the 22 GeV CEBAF would promise to deliver in 10-passes a beam with normalized emittance of 80 mm·mrad and with a relative energy spread of 1.5 × 10-3. Further recirculation beyond 22 GeV is limited by large, 974 MeV per electron, energy loss due to synchrotron radiation.

Bogacz, Slawomir↗

CHANGE OF MAGNETIC FIELD-GAS ALIGNMENT AT THE GRAVITY-DRIVEN ALFVÉNIC TRANSITION IN MOLECULAR CLOUDS: IMPLICATIONS FOR DUST POLARIZATION OBSERVATIONS

Diffuse striations in molecular clouds are preferentially aligned with local magnetic fields, whereas dense filaments tend to be perpendicular to them. When and why this transition occurs remain uncertain. To explore the physics behind this transition, we compute the histogram of relative orientation (HRO) between the density gradient and the magnetic field in three-dimensional magnetohydrodynamic (MHD) simulations of prestellar core formation in shock-compressed regions within giant molecular clouds. We find that, in the magnetically dominated (sub-Alfvénic) post-shock region, the gas structure is preferentially aligned with the local magnetic field. For overdense sub-regions with super-Alfvénic gas, their elongation becomes preferentially perpendicular to the local magnetic field. The transition occurs when self-gravitating gas gains enough kinetic energy from the gravitational acceleration to overcome the magnetic support against the cross-field contraction, which results in a power-law increase of the field strength with density. Similar results can be drawn from HROs in projected two-dimensional maps with integrated column densities and synthetic polarized dust emission. We quantitatively analyze our simulated polarization properties, and interpret the reduced polarization fraction at high column densities as the result of increased distortion of magnetic field directions in trans- or super-Alfvénic gas. Furthermore, we introduce measures of the inclination and tangledness of the magnetic field along the line of sight as the controlling factors of the polarization fraction. Observations of the polarization fraction and angle dispersion can therefore be utilized in studying local magnetic field morphology in star-forming regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Update on the Innovative Carbon/Proton Non-Scaling FFAG Isocentric gantries for Cancer Therapy

There is a dramatic increase in numbers of proton/carbon cancer therapy facilities in recent years due to a clear advantage with respect to the other radiation therapy treatments. Cost of the ion cancer therapy is still to high for most of the hospitals and a dominating part comes from the delivery systems. We had previously presented design of the carbon and proton isocentric gantries using the principle of the non-scaling alternating gradient fixed field magnets (NS-FFAG), where a size and weight of the magnets should be dramatically reduced. The weight of the transport elements of the carbon isocentric gantry is estimated to be 1.5 tons compared to the 130 tons a weight of the Heidelberg gantry. The similar claim of 500 kg comes for the transport elements of the proton permanent magnet gantry. We present an update on these designs.

43 PARTICLE ACCELERATORS↗

ASTROPHYSICAL PARAMETERS OF LS 2883 AND IMPLICATIONS FOR THE PSR B1259-63 GAMMA-RAY BINARY

Only a few binary systems with compact objects display TeV emission. The physical properties of the companion stars represent basic input for understanding the physical mechanisms behind the particle acceleration, emission, and absorption processes in these so-called gamma-ray binaries. Here we present high-resolution and high signal-to-noise optical spectra of LS 2883, the Be star forming a gamma-ray binary with the young non-accreting pulsar PSR B1259-63, showing it to rotate faster and be significantly earlier and more luminous than previously thought. Analysis of the interstellar lines suggests that the system is located at the same distance as (and thus is likely a member of) Cen OB1. Taking the distance to the association, d = 2.3 kpc, and a color excess of E(B - V) = 0.85 for LS 2883 results in M{sub V} {approx} -4.4. Because of fast rotation, LS 2883 is oblate (R{sub eq} {approx_equal} 9.7 R{sub sun} and R{sub pole} {approx_equal} 8.1 R{sub sun}) and presents a temperature gradient (T{sub eq}{approx} 27,500 K, log g{sub eq} = 3.7; T{sub pole}{approx} 34,000 K, log g{sub pole} = 4.1). If the star did not rotate, it would have parameters corresponding to a late O-type star. We estimate its luminosity at log(L{sub *}/L{sub sun}) {approx_equal} 4.79 and its mass at M{sub *} {approx} 30 M{sub sun}. The mass function then implies an inclination of the binary system i{sub orb} {approx} 23{sup 0}, slightly smaller than previous estimates. We discuss the implications of these new astrophysical parameters of LS 2883 for the production of high-energy and very high-energy gamma rays in the PSR B1259-63/LS 2883 gamma-ray binary system. In particular, the stellar properties are very important for prediction of the line-like bulk Comptonization component from the unshocked ultrarelativistic pulsar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

3D tomodosimetry using long scintillating fibers: A feasibility study

Purpose: 3D dosimetry is recognized as an ideal for patient-specific quality assurance (QA) of highly conformal radiotherapy treatments. However, existing 3D dosimeters are not straightforward to implement in the clinic, as their read-out procedure is often tedious and their accuracy, precision, and/or sample size exhibit limitations. The purpose of this work is to develop a 3D dosimeter based on the concept of tomodosimetry inside concentric cylindrical planes using long scintillating fibers for the QA of modern radiotherapy techniques such as intensity-modulated radiation therapy (IMRT) or intensity-modulated arc therapy (IMAT).Methods: Using a model-based simulation, scintillating fibers were modeled on three concentric cylindrical planes of radii 2.5, 5.0, and 7.5 cm, inside a 10 cm radius water-equivalent cylinder phantom. The phantom was set to rotate around its central axis, made parallel to the linac gantry axis of rotation. Light acquisitions were simulated using the calculated dose from the treatment planning software and reconstructed in each cylindrical plane at a resolution of 1 mm{sup 2} using a total-variation minimization iterative reconstruction algorithm. The 3D dose was then interpolated from the reconstructed cylindrical plane doses at a resolution of 1 mm{sup 3}. Different scintillating fiber patterns were compared by varying the angle of each fiber in its cylindrical plane and introducing a light-tight cut in each fiber. The precision of the reconstructed cylindrical dose distribution was evaluated using a Poisson modeling of the acquired light signals and the accuracy of the interpolated 3D dose was evaluated using an IMRT clinical plan for a prostate case.Results: Straight scintillating fiber patterns with light-tight cuts were the most accurate in cylindrical dose reconstruction, showing less than 0.5 mm distance-to-agreement in dose gradients and a mean local dose difference of less than 0.2% in the high dose region for a 10 × 10 cm{sup 2} field. The precision attained with this fiber configuration was less than 0.9% in the high dose, low gradient region of an IMRT segment for light acquisitions of 0.1 MU over a 360 degree rotation of the cylinder phantom. 3D dose interpolation for the IMRT clinical plan yielded an overall dose difference with the reference input of less than 1%, except in high dose gradients.Conclusions: Using long scintillating fibers inside rotating, concentric cylindrical planes, the authors demonstrate that their tomodosimetry method has the potential for high resolution, precise, and accurate 3D dosimetry. Moreover, because of its water-equivalence and rotational symmetry, this design should find interesting application for both treatment QA and machine commissioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flash X-Ray measurements on the shock-induced dispersal of a dense particle curtain

The interaction of a Mach 1.67 shock wave with a dense particle curtain is quantified using flash radiography. These new data provide a view of particle transport inside a compressible, dense gas–solid flow of high optical opacity. The curtain, composed of 115-µm glass spheres, initially spans 87 % of the test section width and has a streamwise thickness of about 2 mm. Radiograph intensities are converted to particle volume fraction distributions using the Beer–Lambert law. The mass in the particle curtain, as determined from the X-ray data, is in reasonable agreement with that given from a simpler method using a load cell and particle imaging. Following shock impingement, the curtain propagates downstream and the peak volume fraction decreases from about 23 to about 4 % over a time of 340 µs. The propagation occurs asymmetrically, with the downstream side of the particle curtain experiencing a greater volume fraction gradient than the upstream side, attributable to the dependence of particle drag on volume fraction. Bulk particle transport is quantified from the time-dependent center of mass of the curtain. Furthermore, the bulk acceleration of the curtain is shown to be greater than that predicted for a single 115-µm particle in a Mach 1.67 shock-induced flow.

36 MATERIALS SCIENCE↗

High voltage studies of inverted-geometry ceramic insulators for a 350 kV DC polarized electron gun

Jefferson Lab is constructing a 350 kV direct current high voltage photoemission gun employing a compact inverted-geometry insulator. This photogun will produce polarized electron beams at an injector test facility intended for low energy nuclear physics experiments, and to assist the development of new technology for the Continuous Electron Beam Accelerator Facility. A photogun operating at 350kV bias voltage reduces the complexity of the injector design, by eliminating the need for a graded-beta radio frequency “capture” section employed to boost lower voltage beams to relativistic speed. However, reliable photogun operation at 350 kV necessitates solving serious high voltage problems related to breakdown and field emission. This study focuses on developing effective methods to avoid breakdown at the interface between the insulator and the commercial high voltage cable that connects the photogun to the high voltage power supply. Three types of inverted insulators were tested, in combination with two electrode configurations. Our results indicate that tailoring the conductivity of the insulator material, and/or adding a cathode triple-junction screening electrode, effectively serves to increase the hold-off voltage from 300kV to more than 375kV. In conclusion, electrostatic field maps suggest these configurations serve to produce a more uniform potential gradient across the insulator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The nitrogen gap in soil health concepts and fertility measurements

Soil nitrogen (N) often limits productivity in agroecosystems, prompting fertilizer applications that increase crop yields but can degrade the environment. Nitrogen's dual role in both productivity and environmental quality should center it in soil health frameworks. We use recent evidence to argue that N availability is an emergent property of the integrated soil biogeochemical system and is strongly influenced by plant traits and their interactions with microbes and minerals. Building upon this, we theorize that the sources of plant and microbial N shift across soil health gradients, from inorganic N dependence in ecologically simple systems with poor soil health to a highly networked supply of organic N in healthy soils; ergo, investments in soil health should increase ecological complexity and the pathways by which plants can access N, leading to more resilient nutrient supplies and yields in a variable climate. However, current N assessment methods derive from a historical emphasis on inorganic N pool sizes and are unable to capture the shifting drivers of N availability across soil health gradients. We highlight the need to better understand the plant-microbial-mineral interactions that regulate bioavailable N as a first step to improving our ability to measure it. We conclude it will be necessary to harness agroecosystem complexity, account for plant and microbial drivers, and carefully integrate external N inputs into soils' internal N network to expand the routes by which N from organic pools can be made bioavailable. Finally, by emphasizing N in soil health concepts, we argue that researchers can accelerate advances in N use efficiency and resiliency.

60 APPLIED LIFE SCIENCES↗

Horizontal Splitter Design For FFA@CEBAF Energy Upgrade: Current Status

Thomas Jefferson National Accelerator Facility (Jefferson Lab) is currently studying the feasibility of an energy upgrade based upon Fixed-Field Alternating Gradient (FFA) permanent magnet technology. The current plan is to replace the highest-energy recirculation arcs with FFA arcs, increasing the total number of beam recirculations, thus the energy. In order to accommodate multiple passes in the FFA arcs, horizontal splitters are being designed to control the beam parameters entering the FFA arcs, as well as the time of flight and R_56. In the current design, six passes will recirculate through the FFA arcs, necessitating the design of six independent beamlines to control the optics and beam dynamics matching into the arcs. These beamlines must fit into the current CEBAF tunnel, while allowing for personnel and equipment access. They must also be flexible enough to accommodate the beam under realistic operational conditions and fluctuations. The constraints on the system are highly restrictive, complicating the design. This document will describe the current state of the design, and indicate the work remaining for a complete conceptual design.

Benesch, Jay↗

Abrupt permafrost thaw drives spatially heterogeneous soil moisture and carbon dioxide fluxes in upland tundra

Permafrost thaw causes the seasonally thawed active layer to deepen, causing the Arctic to shift toward carbon release as soil organic matter becomes susceptible to decomposition. Ground subsidence initiated by ice loss can cause these soils to collapse abruptly, rapidly shifting soil moisture as microtopography changes and also accelerating carbon and nutrient mobilization. The uncertainty of soil moisture trajectories during thaw makes it difficult to predict the role of abrupt thaw in suppressing or exacerbating carbon losses. Here, in this study, we investigated the role of shifting soil moisture conditions on carbon dioxide fluxes during a 13-year permafrost warming experiment that exhibited abrupt thaw. Warming deepened the active layer differentially across treatments, leading to variable rates of subsidence and formation of thermokarst depressions. In turn, differential subsidence caused a gradient of moisture conditions, with some plots becoming consistently inundated with water within thermokarst depressions and others exhibiting generally dry, but more variable soil moisture conditions outside of thermokarst depressions. Experimentally induced permafrost thaw initially drove increasing rates of growing season gross primary productivity (GPP), ecosystem respiration (R eco ), and net ecosystem exchange (NEE) (higher carbon uptake), but the formation of thermokarst depressions began to reverse this trend with a high level of spatial heterogeneity. Plots that subsided at the slowest rate stayed relatively dry and supported higher CO 2 fluxes throughout the 13-year experiment, while plots that subsided very rapidly into the center of a thermokarst feature became consistently wet and experienced a rapid decline in growing season GPP, R eco , and NEE (lower carbon uptake or carbon release). These findings indicate that Earth system models, which do not simulate subsidence and often predict drier active layer conditions, likely overestimate net growing season carbon uptake in abruptly thawing landscapes.

54 ENVIRONMENTAL SCIENCES↗

21 cm absorption by compact hydrogen discs around black holes in radio-loud nuclei of galaxies

The clumpy maser discs observed in some galactic nuclei mark the outskirts of the accretion disc that fuels the central black hole and provide a potential site of nuclear star formation. Unfortunately, most of the gas in maser discs is currently not being probed; large maser gains favor paths that are characterized by a small velocity gradient and require rare edge-on orientations of the disc. Here we propose a method for mapping the atomic hydrogen distribution in nuclear discs through its 21 cm absorption against the radio continuum glow around the central black hole. In NGC 4258, the 21 cm optical depth may approach unity for high angular resolution (VLBI) imaging of coherent clumps which are dominated by thermal broadening and have the column density inferred from x-ray absorption data, {approx}10{sup 23} cm{sup -2}. Spreading the 21 cm absorption over the full rotation velocity width of the material in front of the narrow radio jets gives a mean optical depth of {approx}0.1. Spectroscopic searches for the 21 cm absorption feature in other galaxies can be used to identify the large population of inclined gaseous discs which are not masing in our direction. Follow-up imaging of 21 cm silhouettes of accelerating clumps within these discs can in turn be used to measure cosmological distances.

79 ASTRONOMY AND ASTROPHYSICS↗

High power conditioning and benchmarking of planar nitrogen-incorporated ultrananocrystalline diamond field emission electron source

Planar nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] has emerged as a unique field emission source attractive for accelerator applications because of its capability to generate a high charge beam and handle moderate vacuum conditions. Most importantly, (N)UNCD sources are simple to produce: Conventional high aspect ratio isolated emitters are not required to be formed on the surface, and the actual emitter surface roughness is on the order of only 10–100 nm. A careful reliability assessment of (N)UNCD is required before it may find routine application in accelerator systems. In the present study using an L-band normal conducting single-cell rf gun, a (N)UNCD cathode has been conditioned to ~ 42 MV / m in a well-controlled manner. It reached a maximum output charge of 15 nC corresponding to an average current of 6 mA during an emission period of 2.5 $μ$s . Imaging of the emission current revealed a large number of isolated emitters (density over 100/cm 2 ) distributed on the cathode, which is consistent with previous tests in dc environments. The performance metrics, the emission imaging, and the systematic study of emission properties during rf conditioning in a wide gradient range assert (N)UNCD as an enabling electron source for rf injector designs serving industrial and scientific applications. These studies also improve the fundamental knowledge of the practical conditioning procedure via a better understanding of the emission mechanisms.

43 PARTICLE ACCELERATORS↗

Status of 22 GeV CEBAF Upgrade Using FFA Arcs

Jefferson Lab is exploring an upgrade to extend CEBAF’s energy to ~22 GeV within the existing tunnel by incorporating Fixed-Field Alternating-Gradient (FFA) arcs. In this scheme, the two lowest-energy electromagnetic arcs are removed, the remaining arcs are reassigned to lower energies, and a new pair of high-energy FFA arcs enables six additional recirculations using the existing SRF linacs. The non-scaling FFA lattice employs Halbach-derived permanent magnets with provisions for dipole, quadrupole, and higher-order components, offering large momentum acceptance and reduced operating cost. Implementing this concept requires updated linac optics, modifications to the remaining arcs, and a redesigned electromagnetic switchyard. Ongoing beam-dynamics studies address synchrotron-radiation–induced energy loss and emittance growth, along with strategies for their mitigation.

Ogur, S. [Thomas Jefferson National Accelerator Fa↗

Mo-100 Disk Structural Integrity Tests II

This report is a continuation of the work performed in the report, Mo-100 Disk Structural Integrity Tests I [1]. The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in-beam during production. These large temperature gradients cause high stress and deformation within the disks that could prove detrimental to the target assembly’s cooling performance. Disk fracture is also a possibility that must be understood. Therefore, disk structural integrity tests were performed to understand the thermal induced behavior of these disks. In order to replicate the in-beam conditions, the Mo-100 disks were subjected to large temperature gradients using a 30kW induction heater and coil. A series of transient tests were conducted in a similar fashion as the previous work, as well as an attempt to create steady state conditions for more accurate temperature gradients. The transient thermal test setup and results are described in this report.

36 MATERIALS SCIENCE↗

Modelling the development of capillary pressure in freshly 3D-printed concrete elements

3D concrete printing is a promising technology recently developed to automate construction. Since no formwork is used in this technology to support and protect fresh concrete, there are two aspects which considerably accelerate the development of capillary pressure in 3D-printed concrete in comparison to conventionally placed concrete: i) high stiffness of 3D-printed needed to provide sufficient buildability, and ii) very early and fast evaporation of pore water. Accelerated development of capillary pressure may lead to severe plastic shrinkage cracking in 3D-printed elements and, hence, need to be mitigated. This investigation aims at providing a poromechanical model for capillary pressure development in 3D-printed elements. To simulate the development of capillary pressure and plastic shrinkage, environmental factors, material properties, and element geometry need to be considered as a whole. The model inputs – coefficient of permeability, static bulk modulus, air entry pressure and chemical shrinkage rate – were determined experimentally. The model was validated for two fine-grained concretes. Both 3D-printed materials yielded faster capillary pressure increase in comparison to cast concrete, while partial substitution of cement with silica fume further accelerated the capillary pressure development. Furthermore, due to the lower permeability of the mixture containing silica fume, the gradient of capillary pressure between 3D-printed layers increased, as did the gradient of plastic shrinkage.

36 MATERIALS SCIENCE↗

The correction of linear lattice gradient errors using an AC dipole

Precise measurement of optics from coherent betatron oscillations driven by ac dipoles have been demonstrated at RHIC and the Tevatron. For RHIC, the observed rms beta-beat is about 10%. Reduction of beta-beating is an essential component of performance optimization at high energy colliders. A scheme of optics correction was developed and tested in the RHIC 2008 run, using ac dipole optics for measurement and a few adjustable trim quadruples for correction. In this scheme, we first calculate the phase response matrix from the. measured phase advance, and then apply singular value decomposition (SVD) algorithm to the phase response matrix to find correction quadruple strengths. We present both simulation and some preliminary experimental results of this correction.