Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Gigawatt-year nuclear-geothermal energy storage for light-water and high-temperature reactors

Capital-intensive, low-operating cost nuclear plants are most economical when operated under base-load conditions. However, electricity demand varies on a daily, weekly, and seasonal basis. In deregulated utility markets this implies high prices for electricity at times of high electricity demand and low prices for electricity at times of low electricity demand. We examined coupling nuclear heat sources to geothermal heat storage systems to enable these power sources to meet hourly to seasonal variable electricity demand. At times of low electricity demand the reactor heats a fluid that is then injected a kilometer or more underground to heat rock to high temperatures. The fluid travels through the permeable-rock heat-storage zone, transfers heat to the rock, is returned to the surface to be reheated, and re-injected underground. At times of high electricity demand the cycle is reversed, heat is extracted, and the heat is used to power a geothermal power plant to produce intermediate or peak power. When coupling geothermal heat storage with light-water reactors (LWRs), pressurized water (<300 deg. C) is the preferred heat transfer fluid. When coupling geothermal heat storage with high temperature reactors at higher temperatures, supercritical carbon dioxide is the preferred heat transfer fluid. The non-ideal characteristics of supercritical carbon dioxide create the potential for efficient coupling with supercritical carbon dioxide power cycles. Underground rock cannot be insulated, thus small heat storage systems with high surface to volume ratios are not feasible because of excessive heat losses. The minimum heat storage capacity to enable seasonal storage is {approx}0.1 Gigawatt-year. Three technologies can create the required permeable rock: (1) hydro-fracture, (2) cave-block mining, and (3) selective rock dissolution. The economic assessments indicated a potentially competitive system for production of intermediate load electricity. The basis for a nuclear geothermal system with LWRs exists today; but, there is need for added research and development before deployment. There are significantly greater challenges for geothermal heat storage at higher temperatures. Such systems are strongly dependent upon the local geology. (authors)

15 GEOTHERMAL ENERGY↗

Voltage positioning using co-optimization of controllable grid assets in radial networks

With increasing penetration of solar PV, some distribution feeders are experiencing highly variable net-load flows and even reverse flows. To optimize distribution systems under such conditions, the scheduling of mechanical devices, such as OLTCs and capacitor banks, needs to take into account forecasted solar PV and actual grid conditions. However, these legacy switching assets are operated on a daily or hourly timescale, due to the wear and tear associated with mechanical switching, which makes them unsuitable for real-time control. Therefore, there is a natural timescale- separation between these slower mechanical assets and the responsive nature of inverter-based resources. In this paper, we present a network admissible convex formulation for holistically scheduling controllable grid assets to position voltage optimally against solar PV. An optimal hourly schedule is presented that utilizes mechanical resources to position the predicted voltages close to nominal values, while minimizing the use of inverter-based resources (i.e., DERs), making them available for control at a faster time-scale (after the uncertainty reveals itself). A convex, inner approximation of the OPF problem is adapted to a mixed-integer linear program that minimizes voltage deviations from nominal (i.e., maximizes voltage margins). Here, the resulting OPF solution respects all the network constraints and is, hence, robust against modeling simplifications. Simulation based analysis on IEEE distribution feeders validates the approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Relative Economic Merits of Storage and Combustion Turbines for Meeting Peak Capacity Requirements under Increased Penetration of Solar Photovoltaics

Batteries with several hours of capacity provide an alternative to combustion turbines for meeting peak capacity requirements. Even when compared to state-of-the-art highly flexible combustion turbines, batteries can provide a greater operational value, which is reflected in a lower system-wide production cost. By shifting load and providing operating reserves, batteries can reduce the cost of operating the power system to a traditional electric utility. This added value means that, depending on battery life, batteries can have a higher cost than a combustion turbine of equal capacity and still produce a system with equal or lower overall life-cycle cost. For a utility considering investing in new capacity, the cost premium for batteries is highly sensitive to a variety of factors, including lifetime, natural gas costs, PV penetration, and grid generation mix. In addition, as PV penetration increases, the net electricity demand profile changes, which may reduce the amount of battery energy capacity needed to reliably meet peak demand.

14 SOLAR ENERGY↗

Examination of the Extreme Cold Weather Event Affecting the Power System in Texas - February 2021 [Slides]

This presentation examines the extreme cold weather event that affected the power system in Texas in February 2021. The Texas load-shedding events were caused by a combination of record-high demand and cold weather issues that reduced the output from all types of generation. While some wind turbines were shutting down due to cold temperatures and icing and a lack of cold-weather packages, hourly wind output was accurately predicted. Extreme weather events historically drive grid reliability. Additional examination of more extreme events is needed to understand their impacts on the power system. As a national lab, NREL has the capabilities and facilities to help the industry address these types of challenges. NREL also has significant simulation and analysis capabilities (such as NAERM) that can help understand the impacts of extreme events. NREL also developed the Advanced Research on Integrated Energy Systems (ARIES) Research Platform, which enables evaluation of technologies that smooth grid operations during events like this.

17 WIND ENERGY↗

Results of the 1973 NASA/JPL balloon flight solar cell calibration program

High altitude balloon flights carried 37 standard solar cells for calibration above 99.5 percent of the earth's atmosphere. The cells were assembled into standard modules with appropriate resistors to load each cell at short circuit current. Each standardized module was mounted at the apex of the balloon on a sun tracker which automatically maintained normal incidence to the sun within 1.0 deg. The balloons were launched to reach a float altitude of approximately 36.6 km two hours before solar noon and remain at float altitude for two hours beyond solar noon. Telemetered calibration data on each standard solar cell was collected and recorded on magnetic tape. At the end of each float period the solar cell payload was separated from the balloon by radio command and descended via parachute to a ground recovery crew. Standard solar cells calibrated and recovered in this manner are used as primary intensity reference standards in solar simulators and in terrestrial sunlight for evaluating the performance of other solar cells and solar arrays with similar spectral response characteristics.

Yasui, R. K.↗

A mechanism for the reduction in risk of decompression sickness in microgravity environment

There is an apparent reduction in the incidence of decompression sickness reported by astronauts (from both the USA and the USSR) during extravehicular activity (EVA). The expected incidence, based on studies conducted under unit gravity conditions in Earth-based laboratories, is greater than that encountered during EVA. A biophysical explanation has been proposed for this difference based upon the mechanism of stress-assisted nucleation. Since the partial pressure ratio at which this gas phase forms is considerably smaller in living systems that in quiescent in vitro models, it was proposed that mechanical forces are involved. In that the lower extremities of astronautics are not gravitationally loaded in microgravity, it is possible that tissue gas micronuclei are but minimally regenerated. Most likely, gas micronuclei formed on Earth (by ambulation under 1 g conditions) would be eventually depleted. In a crossover study, 20 individuals were decompressed--from 1 ATA to 0.43 ATA for 3 hours--following either being fully ambulatory at unit gravity or following being hypokinetic and adynamic (simulated microgravity of 3-day bed rest). The subjects were monitored for gas phase formation by means of precordial Doppler monitoring. The results indicate a reduction in whole body gas phase formation in individuals who were bed rested as compared with themselves when fully ambulatory (p = 0.02). In hypokinetic individuals, the protection conferred was equivalent to an extra 175 minutes of oxygen prebreathe. These results are compatible with a hypothesis relating stress-assisted nucleation to the continual formation of tissue gas micronuclei and their gradual depletion with hypokinesia.

Powell, Michael R.↗

Alkaline phosphatase in osteoblasts is down-regulated by pulsatile fluid flow

It is our hypothesis that interstitial fluid flow plays a role in the bone remodeling response to mechanical loading. The fluid flow-induced expression of three proteins (collagen, osteopontin, and alkaline phosphatase) involved in bone remodeling was investigated. Rat calvarial osteoblasts subjected to pulsatile fluid flow at an average shear stress of 5 dyne/cm2 showed decreased alkaline phosphatase (AP) mRNA expression after only 1 hour of flow. After 3 hours of flow, AP mRNA levels had decreased to 30% of stationary control levels and remained at this level for an additional 5 hours of flow. Steady flow (4 dyne/cm2 fluid shear stress), in contrast, resulted in a delayed and less dramatic decrease in AP mRNA expression to 63% of control levels after 8 hours of flow. The reduced AP mRNA expression under pulsatile flow conditions was followed by reduced AP enzyme activity after 24 hours. No changes in collagen or osteopontin mRNA expression were detected over 8 hours of pulsatile flow. This is the first time fluid flow has been shown to affect gene expression in osteoblasts.

Non-NASA Center↗

The VGOS High Road: From Inception and Prototyping to Operations to Maturation and Beyond

Legacy S/X has been the production system of the IVS since the inception of the service. VGOS was declared operational in 2020 after a visionary journey that involved designing, prototyping, and demonstrating the feasibility of the new observing system to generate high-quality geodetic products. And a fledgling VGOS network of between 8 and 10 stations has been contributing IVS products operationally ever since. That VGOS network had further increased by the end of 2022 to 12 stations, and counting. Currently, the VGOS observing program encompasses the 24-hour VGOS-OPS and VGOS-RD session series; further, a weekdaily VGOS Intensive series has been established (with other VGOS Intensives being set up). In addition to the network, VGOS correlation capabilities have also expanded to try to keep pace with the increased VGOS correlation load, morphing into a multi-center distributed correlator. In this poster, we will provide a status overview of the infrastructure realization efforts of the VGOS station network and the correlation centers as well as plans for a bright VGOS future.

VLBI↗

Demand Response Opportunities in Industrial Refrigerated Warehouses in California

Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of film morphology on oxygen and water interaction with copper phthalocyanine

Copper phthalocyanine (CuPc) films of thickness 25 nm and 100 nm were grown by thermal sublimation at 25 C, 150 C, and 250 C in order to vary morphology. Using a source-measure unit and a quartz crystal microbalance (QCM), we measured changes in electrical resistance and film mass in situ during exposure to controlled pulses of O2 and H2O vapor. Mass loading by O2 was enhanced by a factor of 5 in films deposited at 250 C, possibly due to the ~200 C CuPc transition which allows higher O2 mobility between stacked molecules. While gas/vapor sorption occurred over timescales of < 10 minutes, resistance change occurred over timescales > 1 hour, suggesting that mass change occurs by rapid adsorption at active surface sites, whereas resistive response is dominated by slow diffusion of adsorbates into the film bulk. Resistive response generally increases with film deposition temperature due to increased porosity associated with larger crystalline domains. The 25 nm thick films exhibit higher resistive response than 100 nm thick films after an hour of O2/H2O exposure due to the smaller analyte diffusion length required for reaching the film/electrode interface. We found evidence of decoupling of CuPc from the gold-coated QCM crystal due to preferential adsorption of O2/H2O molecules on gold, which is consistent with findings of other studies.

Miller, Nicholas↗

Complete Phase Transformation of Ir Nanowire Network into Defect-Rich Oxide Catalyst for High-Performance PEM Water Electrolysis

Iridium-based catalysts remain the most reliable option for the oxygen evolution reaction (OER) in proton exchange membrane water electrolyzers (PEMWEs). However, their high cost and limited performance represent critical barriers to the commercialization of this green hydrogen production technology. Herein, we report the creation of a metallic Ir nanowire network (IrNWN), which exhibits superior OER performance through its in-situ transition into an oxide structure with high intrinsic activity. At a low loading of 0.25 mgIr/cm2 in PEMWEs, IrNWN achieved a current density of 3.13 A/cm2 at a cell voltage of 1.8 V, outperforming the commercial Ir-based catalyst and surpassing the Department of Energy (DOE) 2026 technical target. Moreover, the high activity of IrNWN was maintained for 900 hours in a durability test at 2 A/cm2, showing a low degradation rate of 0.042 mV/hour. Structural analysis of the electrochemically oxidized IrNWN revealed the presence of mixed Ir oxidation states and a high density of surface terminal oxygen groups (μ1-O), which contributed to a reduced energy barrier for the rate-determining O-O coupling step.

oxygen evolution reaction↗

Evaluation of drilled-ball bearings at DN values to three million. 2: Experimental skid study and endurance tests

Both drilled-and solid-ball 120-mm-bore bearings were tested at speeds up to 24,000 rpm to determine skid characteristics. The thrust loads were varied from 5000 lb down to 370 lb. No gross skidding occurred, and the behavior of the two bearing types was generally similar; however, two drilled-ball bearing failures occurred during the skid tests. In the endurance tests, 25 cycles of start, run (for one hour), and stop were completed before a drilled-ball bearing failed. In all three cases, the ball had failed in flexure fatigue.

Holmes, P. W.↗

Bearing endurance tests in vacuum for sputtered molybdenum disulfide films

Angular-contact, 440C stainless steel, ball bearings with sputtered MoS2 films 0.0000006 x 10-7m (6000 A) thick were evaluated in a vacuum bearing chamber (1750 rpm, 137.9-N- (31-lbf-) thrust load) for endurance. Two types of sputtered films were evaluated: (1) MOS2 sputtered directly onto bearing components, and (2) a thin 0.0000001 x 10-7m (1000 A) underlayer of Cr3Si2 subsequently sputtered with MoS2. Bearing test evaluations in vacuum showed that endurance lives of more than 1000 hours (105,000,000 cycles) were obtained with bearings (cage, races, and balls) directly sputtered with MoS2. The same endurance lives were also obtained when only the races and cage were sputtered with an underlayer of Cr3Si2 and subsequently with MoS2.

Spalvins, T.↗

Vertical Aerosol Backscatter Variability from an Airborne Focused Continuous Wave CO2 Lidar

Atmospheric aerosol backscatter measurements using a continuous wave focused Doppler lidar at 9.1 micron wavelength were obtained over western North America and the Pacific Ocean during 13 - 26 September, 1995 as part of National Aeronautics and Space Administration's (NASA) Multi-center Airborne Coherent Atmospheric Wind Sensor (MACAWS) mission on board the NASA DC8 aircraft. Backscatter variability was measured for approximately 52 flight hours, covering equivalent horizontal distance of approximately 25,000 km in the troposphere. Quasi-vertical backscatter profiles were also obtained during various ascents and descents which ranged between approximately 0.1 to 12.0 km altitude. Aerosol haze layers were encountered at different altitudes. Similarities and differences for aerosol loading over land and over ocean were observed. A mid-tropospheric aerosol backscatter background mode was found with modal value approximately 1O(exp -10)/m/sr, consistent with previous airborne and ground-based datasets.

Jarzembski, Maurice A.↗

Exploring the Effect of EBC Composition on CMAS Wetting Behavior

Rare-earth disilicate (REDS) materials are existing materials used in environmental barrier coating (EBC) for the protection of structural materials in the hot-section of turbine engines. REDS interactions with molten calcium-magnesium-aluminosilicate (CMAS) debris are of interest to understand molten CMAS attack and improve CMAS mitigation strategies. This work assesses the effect of REDS composition on CMAS wetting by investigating wetting angle, spreading, and reactivity. Freestanding atmospheric plasma spray (APS) REDS coatings (for RE = Y, La, Nd, Gd, Yb, Lu) were exposed to 10 mg of CMAS (Ca33-Mg9-Al13-Si45 in single cation mol%) in stagnant lab air at 1250C. APS YbDS was compared to a dense spark plasma sintered (SPS) phase-pure Yb2Si2O7 and a nominal 20 vol% phase-mixture of Yb 2 SiO 5 in Yb 2 Si 2 O 7 (20YbMS/YbDS). CMAS mass was held constant but specimen surface areas varied, yielding a range of loading between ~6 and 10 mg/cm2. CMAS was loaded as a cylindrical rod atop the specimen surface, polished to 4000 grit, and heated to temperature in a Linseis L74/HS/1700 heating microscope. The heating microscope measured the evolution of molten CMAS diameter, height, and contact angle. Molten CMAS diameter at 1150C and contact angle measurements after two hours of exposure at 1250C yielded a positive trend with rare-earth cation size. There was no statistically significant difference in CMAS wetting behavior between SPS YbDS and 20YbMS/YbDS. Post-exposure specimens were examined in plan view and cross-section with XRD, SEM, and EDS. CMAS spreading was cross-examined using plan view SEM, while reactivity utilized plan view XRD and cross-sectional SEM/EDS.

Clark Luckhardt↗

Lithium sulfur batteries and electrolytes and sulfur cathodes thereof

Lithium sulfur battery cells that use water as an electrolyte solvent provide significant cost reductions. Electrolytes for the battery cells may include water solvent for maintaining electroactive sulfur species in solution during cell discharge and a sufficient amount of a cycle life-enhancing compound that facilitates charging at the cathode. The combination of these two components enhances one or more of the following cell attributes: energy density, power density and cycle life. For instance, in applications where cost per Watt-Hour (Wh) is paramount, such as grid storage and traction applications, the use of an aqueous electrolyte in combination with inexpensive sulfur as the cathode active material can be a key enabler for the utility and automotive industries, for example, providing a cost effective and compact solution for load leveling, electric vehicles and renewable energy storage. Sulfur cathodes, and methods of fabricating lithium sulfur cells, in particular for loading lithium sulfide into the cathode structures, provide further advantages.

25 ENERGY STORAGE↗

Dose Modeling for Harborview Research and Training Facility

The Harborview Research and Training (R&T) Facility at the University of Washington (UW) was accidently contaminated from a breached sealed source of Cesium-137. The release occurred during removal of the sealed source from its holder within a portable hot cell in the loading dock area near room 220. The loading dock and northeast corner of the building above the ground floor were impacted by the release, whereas the remaining portions of the R&T Facility were minimally affected. Detailed descriptions of the R&T Facility and the affected area/rooms are included in Section 2. The RESRAD Team in the Environmental Science Division of Argonne National Laboratory visited the site on August 12, 2019, and interviewed the R&T Facility building manager and staff working in the building at that time. Site- and building-specific data were collected including building floor plan CAD drawings, building occupants’ working hours, contaminated rooms photos and their dimensions, building air exchange rates, building materials and “curtain wall” details, and so forth. These data are being used in the dose modeling for potential occupants of the building after it is remediated. The dose modeling was performed using the RESRAD-BUILD computer code, which is designed for the evaluation of radiologically contaminated buildings (Yu et al. 2003). Two hypothetical building occupants of the Harborview R&T Facility were evaluated: a researcher occupying room 726 (a research laboratory on the seventh floor) and a custodian occupying room 220 (loading dock and trash compactor room with a rollup door). A maintenance worker that will be spending less time in impacted areas was not modeled because it will be bounded by other two hypothetical building occupants modeled. A summary description of the RESRAD-BUILD is provided in Appendix A, and the modeling of potential doses to a researcher and a custodian is described in detail in Section 3. A summary and a discussion of the dose modeling results are included in Section 4. The parameters used in the RESRAD-BUILD modeling are included in Appendix B. This report documents the dose modeling results; it does not describe measurements of the actual radioactivity levels at the Harborview R&T Facility, nor does it set any expectation for the actual final radioactivity levels. The radiation doses presented are modeling results based on the generic screening values of Cs-137 and several conservative assumptions and are meant only to assist in decision making regarding decontamination of the Harborview R&T Facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental workflow to estimate model parameters for evaluating long term viscoelastic response of CO2 storage caprocks

Understanding the time-dependent behavior of reservoir and sealing formations is critical to assessing risks associated with geological carbon storage since time-dependent deformation strongly influences mechanical responses of some rock types. Many studies have evaluated the risk of CO2 leakage and induced seismicity by assuming poroelastic rheology in sealing formations. Few have considered viscoelastic or other time-dependent responses, where the existing literature adopts 1D models to represent long-term time-dependent responses. This is primarily because to date, the general form of a reasonable 3D time-dependent model for rocks remains unclear. In this paper, we address this unclear issue by proposing a new workflow to select constitutive modeling parameters to evaluate if a 3D viscoelastic model is reasonable using several-hour-long experimental data and a power-law response to extrapolate to the decades-long time frames of interest in geologic carbon storage. To provide experimental data, we conducted multi-level loading/unloading triaxial relaxation tests with four rock types. The experimental results showed that the maximum load relaxation observed is approximately 49%, with some rock types showing as little as 1.4%. Using a simple linear viscoelastic model, parameters were chosen such that a maximum deviation of 1.5 MPa in axial stress and 7 MPa in radial stress was attained with the extrapolated 30-year data. We found that a reasonable parameter range for the normalized elastic modulus is 0.1~2 for rocks with significant time-dependent responses and 0.01~0.06 for those with small time-dependent responses. No matter how significant time-dependent responses are for rocks considered, our results showed that the relaxation time has a general range of 1~10^10 s, whose time scale can be one or two orders higher than a time frame typically envisioned for CO2 injection projects.

Stress relaxation, 3D time-dependent model, viscoe↗