Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Study on coalescence dynamics of unequal-sized microbubbles captive on solid substrate

The dynamics of bubble coalescence are of importance for a number of industrial processes, in which the size inequality of the parent bubbles plays a significant role in mass transport, topological change and overall motion. In this study, coalescence of unequal-sized microbubbles captive on a solid substrate was observed from cross-section view using synchrotron high-speed imaging technique and a microfluidic gas generation device. The bridging neck growth and surface wave propagation at the early stage of coalescence were investigated by experimental and numerical methods. The results show that theoretical half-power-law of neck growth rate is still valid when viscous effect is neglected. However, the inertial-capillary time scale is associated with the initial radius of the smaller parent microbubble. Furthermore the surface wave propagation rate on the larger parent microbubble is proportional to the inertial-capillary time scale.

42 ENGINEERING↗

Microstructural characterization of SiO2/Ni nanocomposites electrodeposited from a sulphate bath modified by PEI

Highlights: • SiO{sub 2}/Ni + PEI nanocomposites are deposited from the sulphate bath containing PEI. • PEI allows incorporation of higher SiO{sub 2} vol% in SiO{sub 2}/Ni + PEI nanocomposites. • PEI in the form of a thin layer surrounds spherical Ni nanograins and SiO{sub 2} clusters. • PEI action ensures high hardness, tribological properties and corrosion resistance. - Abstract: SiO{sub 2}/Ni nanocomposite coatings containing well-dispersed SiO{sub 2} nanoparticles were electrodeposited from a sulphate bath with and without the addition of polyethylenimine (PEI) as a cationic surfactant. The surface morphology and microstructure in the cross-sections of the deposited nanocomposites were examined by scanning electron microscopy. More detailed microstructure characterization was performed using transmission, scanning-transmission and high resolution transmission electron microscopy. It was determined that the addition of 0.05 g/L and 0.1 g/L of PEI allows the incorporation of SiO{sub 2} nanoparticles in the nickel matrix to be increased in comparison with the nanocomposite deposited without a surfactant. Based on high spatial resolution microanalysis, performed using high count rate energy dispersive spectroscopy of characteristic X-rays in the scanning-transmission mode, the distribution of SiO{sub 2} nanoparticles in the nanocomposite was visualized on elemental maps. Image analysis of the electron microscopy images enabled the mean equivalent circle diameters of grains in the nickel matrix to be determined, together with the volume fraction of SiO{sub 2} nanoparticles in the nanocomposites. The volume fraction of SiO{sub 2} clusters in the SiO{sub 2}/Ni + PEI nanocomposites with the addition of 0.05 g/L and 0.1 g/L of PEI is equal to 18.4% and 13.3%, respectively. Furthermore, the PEI addition allows the nickel grain size in the matrix to be reduced. The combination of different imaging techniques confirmed that PEI is not only present as a surfactant in the electrolytic bath, but also incorporates into the microstructure of the nanocomposite. Nanocomposites electrodeposited in the presence of 0.05 g/L of PEI exhibit higher hardness, good tribological properties and improved corrosion resistance. Although increasing the PEI concentration in the bath up to 0.1 g/L strongly promotes grain size reduction and increase of the SiO{sub 2} volume fraction, it also causes an increase in the PEI fraction embedded in the microstructure, which results in deterioration of the properties of the SiO{sub 2}/Ni + PEI nanocomposites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations from the expected phantom result when scanning at low mAs and low kVp in terms of quantitative metrics (Injected Mass Error 15.4%), goodness of fit (R{sup 2}) of 0.91, and ROI sensitivity (increase in minimum input function ROI radius by 146 ± 86%). These tests also confirmed that the ASIR reconstruction process was beneficial in reducing noise without substantially increasing partial volume effects and that vendor specific modes (e.g., axial shuttle) did not significantly affect the phantom results. The phantom and QA protocol were finally able to quickly (<90 min) and successfully validate the DCE-CT imaging protocol utilized at the three separate institutions of a multicenter clinical trial; thereby enhancing the confidence in the patient data collected.Conclusions: A DCE QA protocol was developed that, in combination with a dynamic multimodality flow phantom, allows the intrascanner variability to be separated from other sources of variability such as the impact of injection protocol and ROI selection. This provides a valuable resource that can be utilized at various clinical trial institutions to test conformance with imaging protocols and accuracy requirements as well as ensure that the scanners are performing as expected for dynamic scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging the presence of silane coatings in concrete with micro X-ray fluorescence

Silane is a commonly used surface treatment to reduce fluid entry into the concrete matrix. This work uses micro X-ray fluorescence (μXRF) to image the presence of silane coatings in field samples and the changes made to the paste chemistry. There are many advantages that μXRF has over other imaging techniques due to the large spot size and the high energy levels. Because of this, μXRF can rapidly investigate large areas and requires minimal sample preparation. Quantitative measurements are made to show that there is a reduction in the amount of sulfur and an increase in potassium in the hydrophobic regions formed by silane coatings. These measurements provide important insights into modifications made to the concrete matrix when silane sealers are used. The mechanisms for the observed chemistry changes are discussed and a simple field or laboratory test method is presented that uses a dye to detect silane coatings.

36 MATERIALS SCIENCE↗

Experimental investigation of fuel temperature effects on transient needle motion and injection velocity of solenoid type diesel injector

Real driving emission (RDE) test conducted in sub-zero temperature conditions has been acting as a severe emission regulation over the existing test methods for diesel engines. In order to cope with this tightened regulation, many studies have been conducted to interpret the factors causing the deteriorated diesel engine combustion in cold operation conditions. The deteriorated fuel injection performance has been regarded as one of the key contributing factors but the governing mechanisms are not thoroughly understood so far. This study aims to provide a comprehensive understanding of the effects of fuel temperature including sub-zero conditions on fuel injection performance by measuring the transient needle motion and injection velocity of a diesel injector using synchrotron X-ray imaging techniques. Here, the factors causing the deteriorated injector performance and their contributions are discussed thoroughly based on the results. The results showed that the injection duration was shortened as the fuel temperature decreased as a result of decreased needle opening speed and increased needle closing speed. The increase of fuel viscosity and bulk modulus was discussed as the main factors associated with these results. The total injection mass was reduced by lowering the fuel temperature not only by the shortened injection duration but also by the decreased injection velocity. These factors exerted near equivalent contribution to the reduced injection mass at low fuel temperatures.

42 ENGINEERING↗

Importance of one- and two-photon transitions in the strong-field dissociation of NO 2+

Employing a coincidence three-dimensional momentum imaging technique, we investigate the ultrafast, intense laser-induced dissociation of a metastable NO 2+ ion beam into N + + O + . Based on the kinetic energy release and angular distributions, measured using both 774-nm and second-order-harmonic 387-nm pulses, we show that the main processes driving dissociation in pulses of about 10 14 W/cm 2 peak intensity are one- and two-photon transitions from the X 2 Σ + ground state to the A 2 Π first-excited state. First-order perturbation theory calculations also corroborate these findings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In-situ L-TEM observations of dynamics of nanometric skyrmions and antiskyrmions

Nanometer-scale magnetic skyrmions and antiskyrmions exhibit unique dynamical behaviors in response to external stimuli, which are critical for their applications in low-power-consumption spintronic devices. This review discusses recent advancements in in-situ Lorentz transmission electron microscopy (L-TEM) observations of skyrmion and antiskyrmion dynamics, and demonstrates the manipulation and evolution of these textures in various magnetic materials under electric, magnetic, and thermal stimuli. Specifically, the motion tracking of single skyrmions and their clusters, and the deformation and transformation of skyrmions has been demonstrated in chiral helimagnets FeGe, Co 9 Zn 9 Mn 2 , and Co 10 Zn 10 with precise application of electric currents. Skyrmions can undergo dynamic transitions in current-driven skyrmion motions, from pinned states to linear flows, and even exhibit deformation into elliptical shapes, underscoring their topological robustness and dynamic flexibility. In addition, the manipulation of single antiskyrmions and antiskyrmion-lattice phases in (Fe 0.63 Ni 0.3 Pd 0.07 ) 3 P with S 4 symmetry is discussed, highlighting their high mobility and unique sliding capabilities along stripe domains at room temperature, facilitated by nanosecond pulsed electric currents. Finally, the temperature gradient-driven motion and topological transformation of elliptical skyrmions and antiskyrmions in this same material are investigated. In conclusion, the comprehensive insights gained from the L-TEM imaging technique are pivotal in advancing the design and functionality of next-generation skyrmion/antiskyrmion-based spintronic devices.

(Anti)skyrmion↗

Progression of soot cake layer properties during the systematic regeneration of diesel particulate filters measured with neutron tomography

Although particulate filters (PFs) have been a key component of the emission control system for modern diesel engines, there remain significant questions about the basic regeneration behavior of the filters and how it changes with accumulation of increasing soot layers. This effort describes a systematic deposition and regeneration of particulate matter in 25-mm diameter × 76-mm long wall-flow PFs composed of silicon carbide (SiC) material. The initial soot distributions were analyzed for soot cake thickness using a nondestructive neutron imaging technique. With the PFs intact, it was then possible to sequentially regenerate the samples and reanalyze them, which was performed after nominal 20, 50, and 70 % regenerations. The loaded samples show a relatively uniform distribution of particulate with an increasing soot cake thickness and nearly identical initial density of 70 mg/cm 3 . Throughout regeneration, the soot cake thickness initially decreases significantly while the density increases to 80–90 mg/cm 3 . After ~50 % regeneration, the soot cake thickness stays relatively constant, but instead, the density decreases as pores open up in the layer (~35 mg/cm 3 at 70 % regeneration). Here, complete regeneration initially occurs at the rear of the PF channels. With this information, a conceptual model of the regeneration is proposed.

54 ENVIRONMENTAL SCIENCES↗

Ion-coincidence momentum imaging of three-body Coulomb explosion of formaldehyde in ultrashort intense laser fields

Three-body Coulomb explosion of formaldehyde (H{sub 2}CO) in intense 7- and 35-fs laser fields (1.3 × 10{sup 15} W/cm{sup 2}) has been investigated by using ion-coincidence momentum imaging technique. Two types of explosion pathways from the triply charged state, H{sub 2}CO{sup 3+} → (i) H{sup +} + H{sup +} + CO{sup +} and (ii) H{sup +} + CH{sup +} + O{sup +}, have been identified. It is shown from the momentum correlation of the fragment ions of pathway (i), that the geometrical structure of the molecule is essentially frozen along the H-C-H bending coordinate for the 7-fs case. On the other hand, for a longer pulse duration (35 fs), structural deformation along the C-H stretching and H-C-H bending coordinates is identified, which is ascribed to the nuclear dynamics in the dication states populated within the laser pulse duration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intra-Grain Local Luminescence Properties of CdSe0.1Te0.9 Thin Films

We report on the local photoluminescence properties of grains and grain boundaries of CdSe 0.1 Te 0.9 thin film deposited by the colossal grain growth method using a wide-field hyperspectral imaging technique. We observed significant variations in the photoluminescence intensity of both individual grains and also that of grain boundaries. Multiple sub-bandgap defect peaks were captured in the luminescence spectra in the energy range 1.2 eV to 1.6 eV. The intensity and peak positions of these sub-gap emissions were slightly different among various grains and at the grain boundaries, revealing intra- and inter-grain variations in these polycrystalline thin films. A recently-developed density-of-states based photoluminescence model was extended to include multiple peaks and was fitted to the data. We observed that at a fixed temperature, the quasi-Fermi level splitting energy and a disordered energy parameter can be extracted locally by use of this model.

data models↗

Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributable risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional radiogenic lethal cancer incidents. According to the decision model calculations, the use of CT is more favorable over the use of radiography alone or radiography with CT by a factor of 13, for low risk 20 yr old patients, to a factor of 23, for high risk patients younger than 80 yr old. The radiography/CT imaging strategy slightly outperforms plain radiography for high and moderate risk patients. Regardless of the patient age, sex, and fracture risk, the higher diagnostic accuracy obtained by the CT examination counterbalances the increase in dose compared to plain radiography or radiography followed by CT only for positive radiographs and renders CT utilization justified and the radiographic screening redundant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Differences in the hemodynamic response to event-related motor and visual paradigms as measured by near-infrared spectroscopy

Several current brain imaging techniques rest on the assumption of a tight coupling between neural activity and hemodynamic response. The nature of this neurovascular coupling, however, is not completely understood. There is some evidence for a decoupling of these processes at the onset of neural activity, which manifests itself as a momentary increase in the relative concentration of deoxyhemoglobin (HbR). The existence of this early component of the hemodynamic response function, however, is controversial, as it is inconsistently found. Near infrared spectroscopy (NIRS) allows quantification of levels of oxyhemoglobin (HbO(2)) and HbR during task performance in humans. We acquired NIRS data during performance of simple motor and visual tasks, using rapid-presentation event-related paradigms. Our results demonstrate that rapid, event-related NIRS can provide robust estimates of the hemodynamic response without artifacts due to low-frequency signal components, unlike data from blocked designs. In both the motor and visual data the onset of the increase in HbO(2) occurs before HbR decreases, and there is a poststimulus undershoot. Our results also show that total blood volume (HbT) drops before HbO(2) and undershoots baseline, raising a new issue for neurovascular models. We did not find early deoxygenation in the motor data using physiologically plausible values for the differential pathlength factor, but did find one in the visual data. We suggest that this difference, which is consistent with functional magnetic resonance imaging (fMRI) data, may be attributable to different capillary transit times in these cortices.

NASA Program Biomedical Research and Countermeasur↗

Eccentric needle motion effect on near-nozzle dynamics of diesel spray

Here, the eccentric needle motion has been regarded as an important cause of in-nozzle flow disturbances and hole-to-hole spray variations of modern fuel injectors. However, the experimental investigations on this subject have rarely been reported due to great difficulties in the direct measurements of eccentric needle motion and the flow characteristics of individual holes in an injection nozzle. In this study, the axial and eccentric needle motion and the ear-nozzle spray dynamics of 3-hole, 5-hole and 8-hole diesel injection nozzles were investigated in varied injection pressure conditions using an xray phase-contrast imaging technique. The eccentric needle motion and near-nozzle spray axial velocity showed temporal oscillations during the injection with different oscillation frequencies. The frequencies of these two oscillations were independent to the nozzle and injection pressure. To discuss the mutual dependency of these two oscillations, the time traces of the spray axial velocity were measured for individual holes. The results showed that the oscillation phase, frequency and amplitude of the spray axial velocity were almost identical for all holes, which indicated that the sac pressure variation rather than hole-to-hole flow variation can be the primary cause of the spray axial velocity oscillation by the eccentric needle motion. The adequacy of this consideration was thoroughly discussed using a mass balance model in the nozzle sac that predicted the sac pressure variation during an injection event.

42 ENGINEERING↗

Investigation of Needle Motion Profile Effect on Diesel Spray in Near-Nozzle Field

A variety of needle-motion profiles are used in diesel injectors. However, it is unclear what the underlying mechanism is to determine the needle-motion profiles and how they affect the spray dynamics. It has been of significant interest to examine how the spray dynamics will change if only altering the needle valve opening speed or closing speed while all other parameters are kept the same. The different needle-motion profiles were obtained using a piezo nozzle (Nozzle #P) and a solenoid nozzle (Nozzle #S), which have identical nozzle geometry. By utilizing the X-ray imaging technique, it was observed that the average needle valve speed of Nozzle #P was 51% higher at the opening stage but 17% lower at the closing stage than Nozzle #S. When the needle valve lift is low (approximately 200 μm), the needle valve opening speed has a crucial effect on spray dynamics. The faster needle valve opening of Nozzle #P results in a 42% larger spray spreading angle and 34% lower spray velocity at the downstream field. The spray dynamics may be controllable by properly designing the needle-motion profiles in the scenarios of the low needle lifts. However, when the needle valve is sufficiently open (approximately over 200 μm), almost identical spray characteristics were observed regardless of the needle-motion profiles.

47 OTHER INSTRUMENTATION↗

Observation of yttrium oxide nanoparticles in cabbage (Brassica oleracea) through dual energy K-edge subtraction imaging

Background: The potential transfer of engineered nanoparticles (ENPs) from plants into the food chain has raised widespread concerns. In order to investigate the effects of ENPs on plants, young cabbage plants (Brassica oleracea) were exposed to a hydroponic system containing yttrium oxide (yttria) ENPs. The objective of this study was to reveal the impacts of NPs on plants by using K-edge subtraction imaging technique. Results: Using synchrotron dual-e nergy X-ray micro-tomography with K-edge subtraction technique, we studied the uptake, accumulation, distribution and concentration mapping of yttria ENPs in cabbage plants. It was found that yttria ENPs were uptaken by the cabbage roots but did not effectively transferred and mobilized through the cabbage stem and leaves. This could be due to the accumulation of yttria ENPs blocked at primary-lateral-root junction. Instead, non-yttria minerals were found in the xylem vessels of roots and stem. Conclusions: Synchrotron dual-energy X-ray micro-tomography is an effective method to observe yttria NPs inside the cabbage plants in both whole body and microscale level. Furthermore, the blockage of a plant's roots by nanoparticles is likely the first and potentially fatal environmental effect of such type of nanoparticles.

59 BASIC BIOLOGICAL SCIENCES↗

Accurate determination of electronic transport properties of silicon wafers by nonlinear photocarrier radiometry with multiple pump beam sizes

In this paper, photocarrier radiometry (PCR) technique with multiple pump beam sizes is employed to determine simultaneously the electronic transport parameters (the carrier lifetime, the carrier diffusion coefficient, and the front surface recombination velocity) of silicon wafers. By employing the multiple pump beam sizes, the influence of instrumental frequency response on the multi-parameter estimation is totally eliminated. A nonlinear PCR model is developed to interpret the PCR signal. Theoretical simulations are performed to investigate the uncertainties of the estimated parameter values by investigating the dependence of a mean square variance on the corresponding transport parameters and compared to that obtained by the conventional frequency-scan method, in which only the frequency dependences of the PCR amplitude and phase are recorded at single pump beam size. Simulation results show that the proposed multiple-pump-beam-size method can improve significantly the accuracy of the determination of the electronic transport parameters. Comparative experiments with a p-type silicon wafer with resistivity 0.1–0.2 Ω·cm are performed, and the electronic transport properties are determined simultaneously. The estimated uncertainties of the carrier lifetime, diffusion coefficient, and front surface recombination velocity are approximately ±10.7%, ±8.6%, and ±35.4% by the proposed multiple-pump-beam-size method, which is much improved than ±15.9%, ±29.1%, and >±50% by the conventional frequency-scan method. The transport parameters determined by the proposed multiple-pump-beam-size PCR method are in good agreement with that obtained by a steady-state PCR imaging technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photodissociation dynamics of propionyl chloride in the ultraviolet region

Velocity imaging technique combined with (2+1) resonance-enhanced multiphoton ionization (REMPI) is used to detect primary photodissociation of propionyl chloride. In one-color experiments at 235 nm, the Cl and Cl* fragments are produced rapidly, leading to a fraction of translational energy release of 0.37 and 0.35, anisotropy parameters of 1.1 and 0.8, and quantum yield of 0.67 and 0.33, respectively, when initial excitation of the {sup 1}(n, {pi}*){sub CO} band is coupled to the {sup 1}(n{sub Cl}, {sigma}{sub C-Cl}*) repulsive configuration. The resulting propionyl radical with sufficient internal energy may undergo secondary dissociation to yield CO that is characteristic of an isotropic distribution. The REMPI spectra of the CO (0,0) and (1,1) bands are measured, giving rise to a Boltzmann rotational temperature of 1200 and 770 K, respectively, and a Boltzmann vibrational temperature of 2800 K. A minor channel of HCl elimination is not detected, probably because of predissociation in two-photon absorption at 235 nm. In two-color experiments comprising an additional 248 nm photolyzing laser, Cl and Cl* are produced with a fraction of translational energy release of 0.43 and 0.40 and anisotropy parameters of 1.0 and 0.6, respectively. The secondary production of CO is not observed although the internal energy partitioned in the propionyl radical is in the proximity of the dissociation barrier. In either experimental scheme, a small component appearing in the center of the Cl and Cl* images is proposed to stem from ground state dissociation via internal conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-molecule imaging at high fluorophore concentrations by local activation of dye

Single-molecule fluorescence microscopy is a powerful approach to observe biomolecular interactions with high spatial and temporal resolution. Detecting fluorescent signals from individual, labeled proteins above high levels of background fluorescence remains challenging, however. For this reason, the concentrations of labeled proteins in in vitro assays are often kept low compared to their in vivo concentrations. Here, we present a new fluorescence imaging technique by which single fluorescent molecules can be observed in real time at high, physiologically relevant concentrations. The technique requires a protein and its macromolecular substrate to be labeled each with a different fluorophore. Then, making use of short-distance energy-transfer mechanisms, the fluorescence from only those proteins bound to their substrate are selectively activated. This approach is demonstrated by labeling a DNA substrate with an intercalating stain, exciting the stain, and using energy transfer from the stain to activate the fluorescence of only those labeled DNA-binding proteins bound to the DNA. Such an experimental design allowed us to observe the sequence-independent interaction of Cy5-labeled interferon-inducible protein 16 (IFI16) with DNA and the sliding via one-dimensional diffusion of Cy5-labeled adenovirus protease (pVIc-AVP) on DNA in the presence of a background of hundreds of nM Cy5 fluorophore.

59 BASIC BIOLOGICAL SCIENCES↗