Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated circuits.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Finite Ground Coplanar (FGC) Waveguide: A Better Transmission Line for Microwave Circuits

A new version of coplanar waveguide (CPW) with electrically narrow ground strips 14 has been developed for microwave integrated circuits. This transmission line, referred to by Finite Ground Coplanar (FGC) waveguide, has several advantages over conventional coplanar waveguide. Since the ground strips are narrow, parasitic resonances that develop when the CPW is placed on a carrier or in a package are eliminated. In addition, the narrow ground strips permit the integration of lumped and distributed circuit elements in the ground strips as well as in the center strip to reduce the circuit size and improve its performance. Finally, the coupling between adjacent FGC transmission lines is lower than the coupling between CPW lines for the same spacing between the lines. All of these attributes of FGC are presented in this paper.

Ponchak, George E.↗

Microelectronics package design using experimentally-validated modeling and simulation.

Packaging high power radio frequency integrated circuits (RFICs) in low temperature cofired ceramic (LTCC) presents many challenges. Within the constraints of LTCC fabrication, the design must provide the usual electrical isolation and interconnections required to package the IC, with additional consideration given to RF isolation and thermal management. While iterative design and prototyping is an option for developing RFIC packaging, it would be expensive and most likely unsuccessful due to the complexity of the problem. To facilitate and optimize package design, thermal and mechanical simulations were used to understand and control the critical parameters in LTCC package design. The models were validated through comparisons to experimental results. This paper summarizes an experimentally-validated modeling approach to RFIC package design, and presents some results and key findings.

36 MATERIALS SCIENCE↗

Amplifier improvement circuit

Stable input stage was designed for the use with a integrated circuit operational amplifier to provide improved performance as an instrumentation-type amplifier. The circuit provides high input impedance, stable gain, good common mode rejection, very low drift, and low output impedance.

Sturman, J.↗

Integrated Power and Attitude Control System (IPACS)

Recent advances in materials, circuit integration and power switching have given the concept of dynamic energy and momentum storage important weight size, and operational advantages over the conventional momentum wheel-battery configuration. Simultaneous momentum and energy storage for a three axes stabilized spacecraft can be accomplished with a topology of at least four wheels where energy (a scalar) is stored or retrieved in such a manner as to keep the momentum vector invariant. This study, instead, considers the case of two counter-rotating wheels in one axis to more effectively portray the principles involved. General scalable system design equations are derived which demonstrate the role of momentum storage when combined with energy storage.

Michaelis, Theodore D.↗

Temperature-Adaptive Circuits on Reconfigurable Analog Arrays

Demonstration of a self-reconfigurable Integrated Circuit (IC) that would operate under extreme temperature (-180 C and 120 C) and radiation (300krad), without the protection of thermal controls and radiation shields. Self-Reconfigurable Electronics platform: a) Evolutionary Processor (EP) to run reconfiguration mechanism; b) Reconfigurable chip (FPGA, FPAA, etc).

self-recovery↗

Plasma-based method for delayering of circuits

The present invention relates to methods of delayering a semiconductor integrated circuit die or wafer. In at least one aspect, the method includes exposing a die or wafer to plasma of an etching gas and detecting exposure of one or more metal layers within the die. In one aspect of the invention, the plasma of the etching gas is non-selective and removes all materials in a layer at about the same rate. In another aspect of the invention, two different plasmas of corresponding etching gases are employed with each plasma of the etching gas being selective, thus necessitating the sequential use of both plasmas of corresponding etching gases to remove all materials in a layer.

Shul, Randy J.↗

Influences of carrier diffusion and radial mode field pattern on high speed characteristics for microring lasers

High-speed directly modulated microlasers are potential light sources for on-chip optical interconnection and photonic integrated circuits. In this Letter, dynamic characteristics are studied for microring lasers by rate equation analysis considering radial carrier hole burning and diffusion and experimentally. The coupled modes with a wide radial field pattern and the injection current focused in the edge area of microring resonator can greatly improve the high speed response curve due to the less carrier hole burning. The small-signal response curves of a microring laser connected with an output waveguide exhibit a larger 3 dB bandwidth and smaller roll-off at low frequency than that of the microdisk laser with the same radius of 15 μm, which accords with the simulation results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and performance of a suprathermal electron spectrometer to study auroral precipitations

The design, development, and performance of Medium-energy Electron SPectrometer (MESP), dedicated to the in situ observation of suprathermal electrons in the auroral ionosphere, are summarized in this paper. MESP employs a permanent magnet filter with a light tight structure to select electrons with proper energies guided to the detectors. A combination of two avalanche photodiodes and a large area solid-state detector (SSD) provided 46 total energy bins (1 keV resolution for 3−20 keV range for APDs, and 7 keV resolution for >20 keV range for SSDs). Multi-channel ultra-low power application-specific integrated circuits are also verified for the flight operation to read-out and analyze the detector signals. MESP was launched from Poker Flat Research Range on 3 March 2014 as a part of ground-to-rocket electrodynamics-electrons correlative experiment (GREECE) mission. MESP successfully measured the precipitating electrons from 3 to 120 keV in 120-ms time resolution and characterized the features of suprathermal distributions associated with auroral arcs throughout the flight. The measured electrons were showing the inverted-V type spectra, consistent with the past measurements. In addition, investigations of the suprathermal electron population indicated the existence of the energetic non-thermal distribution corresponding to the brightest aurora.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlation of the nanostructure with optoelectronic properties during rapid thermal annealing of Ga(NAsP) quantum wells grown on Si(001) substrates

Ga(NAsP) quantum wells grown pseudomorphically on Si substrate are promising candidates for optically active light sources in future optoelectronically integrated circuits on Si substrates. As the material is typically grown at low temperatures, it has to be thermally annealed after growth to remove defects and optimize optoelectronic properties. Here we show by quantitative transmission electron microscopy that two different kinds of structural development are associated with the annealing. First of all, the quantum well homogeneity improves with increasing annealing temperature. For annealing temperatures above 925 °C the composition becomes less homogeneous again. Second, voids form in the quantum well for annealing temperatures above 850 °C. Their density and size increase continuously with increasing annealing temperature. These results are correlated to the optical properties of the samples, where we find from temperature-dependent photoluminescence measurements two scales of disorder, which show the same temperature dependence as the structural properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heavy ion radiation effects studies with ion photon emission microscopy.

The development of a new radiation effects microscopy (REM) technique is crucial as emerging semiconductor technologies demonstrate smaller feature sizes and thicker back end of line (BEOL) layers. To penetrate these materials and still deposit sufficient energy into the device to induce single event effects, high energy heavy ions are required. Ion photon emission microscopy (IPEM) is a technique that utilizes coincident photons, which are emitted from the location of each ion impact to map out regions of radiation sensitivity in integrated circuits and devices, circumventing the obstacle of focusing high-energy heavy ions. Several versions of the IPEM have been developed and implemented at Sandia National Laboratories (SNL). One such instrument has been utilized on the microbeam line of the 6 MV tandem accelerator at SNL. Another IPEM was designed for ex-vacu use at the 88 cyclotron at Lawrence Berkeley National Laboratory (LBNL). Extensive engineering is involved in the development of these IPEM systems, including resolving issues with electronics, event timing, optics, phosphor selection, and mechanics. The various versions of the IPEM and the obstacles, as well as benefits associated with each will be presented. In addition, the current stage of IPEM development as a user instrument will be discussed in the context of recent results.

43 PARTICLE ACCELERATORS↗

Critical Vacancy-Driven Phenomena in High-Energy Ion-Implanted Silicon

High-energy (MeV) ion implantation is now being rapidly introduced into integrated circuit manufacturing because it promises process simplification and improved device performance. However, high-energy implantation introduces an imbalance of excess vacancies and vacancy-cluster defects in the near-surface region of a silicon crystal. These defects interact with dopants affecting diffusion and electrical activation during subsequent processing. The objective of this project was to develop sufficient understanding of the physical mechanisms underlying the evolution of these defects and interactions with dopant atoms to enable accurate prediction and control of dopant diffusion and defect configurations during processing. This project supported the DOE mission in science and technology by extending ongoing Basic Energy Sciences programs in ion-solid physics and x-ray scattering at ORNL into new areas. It also strengthened the national capability for advanced processing of electronic materials, an enabling technology for DOE programs in energy conversion, use, and defense.

36 MATERIALS SCIENCE↗

Focal depth measurement of scanning helium ion microscope

When facing the challenges of critical dimension measurement of complicated nanostructures, such as of the three dimension integrated circuit, characterization of the focal depth of microscopes is important. In this Letter, we developed a method for characterizing the focal depth of a scanning helium ion microscope (HIM) by using an atomic force microscope tip characterizer (ATC). The ATC was tilted in a sample chamber at an angle to the scanning plan. Secondary electron images (SEIs) were obtained at different positions of the ATC. The edge resolution of the SEIs shows the nominal diameters of the helium ion beam at different focal levels. With this method, the nominal shapes of the helium ion beams were obtained with different apertures. Our results show that a small aperture is necessary to get a high spatial resolution and high depth of field images with HIM. This work provides a method for characterizing and improving the performance of HIM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TARGET: A multi-channel digitizer chip for very-high-energy gamma-ray telescopes

The next-generation very-high-energy (VHE) gamma-ray observatory, the Cherenkov Telescope Array, will feature dozens of imaging atmospheric Cherenkov telescopes (IACTs), each with thousands of pixels of photosensors. To be affordable and reliable, reading out such a mega-channel array requires event recording technology that is highly integrated and modular, with a low cost per channel. We present the design and performance of a chip targeted to this application: the TeV Array Readout with GSa/s sampling and Event Trigger (TARGET). This application-specific integrated circuit (ASIC) has 16 parallel input channels, a 4096-sample buffer for each channel, adjustable input termination, self-trigger functionality, and tight window-selected readout. We report the performance of TARGET in terms of sampling frequency, power consumption, dynamic range, current-mode gain, analog bandwidth, and cross talk. The large number of channels per chip allows a low cost per channel ($10 to $20 including front-end and back-end electronics but not including photosensors) to be achieved with a TARGET-based IACT readout system. In addition to basic performance parameters of the TARGET chip itself, we present a camera module prototype as well as a second-generation chip (TARGET 2), both of which have been produced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Juvenile Salmon Acoustic Telemetry System Transmitter Downsize Assessment

At the request of the U.S. Army Corps of Engineers, Portland District, researchers from Pacific Northwest National Laboratory investigated the use of an application-specific integrated circuit (ASIC) to reduce the weight and volume of Juvenile Salmon Acoustic Telemetry System (JSATS) transmitters while retaining current functionality. Review of the design of current JSATS transmitters identified components that could be replaced by an ASIC while retaining the function of the current transmitter and offering opportunities to extend function if desired. ASIC design alternatives were identified that could meet transmitter weight and volume targets of 200 mg and 100 mm3. If alternatives to the cylindrical batteries used in current JSATS transmitters can be identified, it could be possible to implant ASIC-based JSATS transmitters by injection rather than surgery. Using criteria for the size of fish suitable for surgical implantation of current JSATS transmitters, it was concluded that fish as small as 70 mm in length could be implanted with an ASIC-based transmitter, particularly if implantation by injection became feasible.

47 OTHER INSTRUMENTATION↗

Controlling Nickel Sillicide Phase by Si Implantation Damage

In the context of fabrication process of contacts in CMOS integrated circuits, we studied the effect of implantation-induced damage on the Ni silicide phase formation sequence. The device layers of Silicon-on-insulator samples were implanted with 30 or 60 keV Si ions at several fluences up to amorphization. Next, 10 or 30 nm Ni layers were deposited. The monitoring of annealing treatments was achieved with time-resolved X-ray diffraction (XRD) technique. Rutherford Backscattering Spectrometry and pole figure XRD were also used to characterize some intermediate phase formations. We show the existence of an implantation threshold (1 ions/nm{sup 2}) from where the silicidation behaviour changes significantly, the formation temperature of the disilicide namely shifting abruptly from 800 to 450 C. It is also found that the monosilicide formation onset temperature for the thinner Ni deposits increases linearly by about 30 C with the amount of damage.

36 MATERIALS SCIENCE↗

Fault localization and analysis in semiconductor devices with optical-feedback infrared confocal microscopy

We report on a cost-effective optical setup for characterizing light-emitting semiconductor devices with optical-feedback confocal infrared microscopy and optical beam-induced resistance change.We utilize the focused beam from an infrared laser diode to induce local thermal resistance changes across the surface of a biased integrated circuit (IC) sample. Variations in the multiple current paths are mapped by scanning the IC across the focused beam. The high-contrast current maps allow accurate differentiation of the functional and defective sites, or the isolation of the surface-emittingp-i-n devices in the IC. Optical beam-induced current (OBIC) is not generated since the incident beam energy is lower than the bandgap energy of the p-i-n device. Inhomogeneous current distributions in the IC become apparent without the strong OBIC background. They are located at a diffraction-limited resolution by referencing the current maps against the confocal reflectance image that is simultaneously acquired via optical-feedback detection. Our technique permits the accurate identification of metal and semiconductor sites as well as the classification of different metallic structures according to thickness, composition, or spatial inhomogeneity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Approaches to USJ Formation Beyond Molecular Implantation

As junction depth requirements approach sub 10 nm and the sensitivity to residual implant damage continues to increase, the capability to produce abrupt, shallow profiles while maintaining low residual damage becomes a difficult challenge. Implantation induced amorphization has been widely applied to reduce channeling tails of implanted dopant profiles for integrated circuit manufacturing. This has been required to meet aggressive junction depth targets. The problem, however, is that pre-amorphization creates high defect densities that remain near the former amorphous-crystalline interface post anneal. These end of range (EOR) defects become of greater concern as the industry begins to move towards millisecond anneal technologies. Millisecond anneal, while capable of close to diffusionless activation and abrupt junctions, has caused concern for its inability to fully repair these EOR defects. There has been a recent focus on removing traditional PAI through molecular implantation with limited success. Towards this end we have investigated alternative techniques to reduce EOR damage while maintaining the junction depth, sheet resistance and abruptness. Here we describe the results of two of these techniques. The subsequent reduction in EOR through the use of each process and the resultant Rs, junction depth and abruptness are detailed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High quality single crystal Ge nano-membranes for opto-electronic integrated circuitry

A thin, flat, and single crystal germanium membrane would be an ideal platform on which to mount sensors or integrate photonic and electronic devices, using standard silicon processing technology. We present a fabrication technique compatible with integrated-circuit wafer scale processing to produce membranes of thickness between 60 nm and 800 nm, with large areas of up to 3.5 mm{sup 2}. We show how the optical properties change with thickness, including appearance of Fabry-Pérot type interference in thin membranes. The membranes have low Q-factors, which allow the platforms to counteract distortion during agitation and movement. Finally, we report on the physical characteristics showing sub-nm roughness and a homogenous strain profile throughout the freestanding layer, making the single crystal Ge membrane an excellent platform for further epitaxial growth or deposition of materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗