At least 1,081 records · Page 60

Modelling and control coordination scheme of a wind‐to‐hydrogen set for future renewable‐based power systems

New challenges regarding system stability and efficiency arise when power systems operate with a high penetration level of inverter‐based renewable sources (IBRSs) and few synchronous generators. Since IBRSs have been on the rise, to secure the stable operation of future power systems, IBRSs will be required to support systems without having to rely on remaining synchronous generators. Also, to efficiently manage the uncertainty of renewable production, power‐to‐gas technology can provide the required flexibility. This study proposes modelling and a control coordination scheme (CCS) of a wind‐to‐hydrogen (W2H) set to optimise electricity production from a variable‐speed wind turbine generator (WTG) while helping balance between supply and demand in a system. To achieve this, a grid‐forming (GFM) inverter‐based WTG is modelled and a set of electrolyser and fuel cell is integrated at the DC circuit of a GFM‐WTG to be coordinated. Furthermore, the CCS offers an opportunity to reduce the investment cost for deploying a W2H set by utilising the control capabilities of a WTG and reducing the need for an additional device. The performance of the proposed W2H set with the CCS was verified considering the variations in system load and wind speed by using Power System Computer Aided Design (PSCAD)/ElectroMagnetic Transients including Direct Current (EMTDC).

Kim, Jinho↗

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗

Machine Learning for Dynamical Modeling of a Flexible Inverted Pendulum System

The inverted pendulum system, a canonical example of an unstable mechanical system, is often used to model the control problems encountered in the flight of rockets in the initial stages of launch, when the airspeed is too small for aerodynamic stability. A system with a flexible pendulum is a variant that more accurately simulates rocket flight nonlinearities (particularly, the flex modes of the rocket). To increase NASA capability of modeling dynamical systems for which closed form solutions are not clear or easily developed, this project aims to provide a machine learning approach that produces a learned dynamical model of the PENNY robot (a rover with a flexible inverted pendulum) from operational data. The developed approach can then be generalized to other complex dynamical systems, including but not limited to rockets and other robotic systems.

M. A. DuPuis↗

Self-learning fuzzy controllers based on temporal back propagation

This paper presents a generalized control strategy that enhances fuzzy controllers with self-learning capability for achieving prescribed control objectives in a near-optimal manner. This methodology, termed temporal back propagation, is model-insensitive in the sense that it can deal with plants that can be represented in a piecewise-differentiable format, such as difference equations, neural networks, GMDH structures, and fuzzy models. Regardless of the numbers of inputs and outputs of the plants under consideration, the proposed approach can either refine the fuzzy if-then rules if human experts, or automatically derive the fuzzy if-then rules obtained from human experts are not available. The inverted pendulum system is employed as a test-bed to demonstrate the effectiveness of the proposed control scheme and the robustness of the acquired fuzzy controller.

Jang, Jyh-Shing R.↗

Power-Hardware-in-the-Loop Experiments of a Microgrid With a Grid-Forming Battery Inverter: Preprint

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sequence Impedance Measurement of Utility-Scale Wind Turbines and Inverters – Reference Frame, Frequency Coupling, and MIMO/SISO Forms

Sequence impedance responses with or without considering frequency coupling in both MIMO and SISO forms are increasingly used for the stability analysis of three-phase power electronic systems; however, many aspects of sequence impedance measurement are not fully explored. It is not clear if the sequence impedance has a reference frame similar to the dq impedance. If so, the role of the grid voltage angle estimation in aligning the sequence impedance reference frame has not been discussed. Additionally, existing methods for measuring the sequence impedance with frequency coupling are complicated, are not feasible for large wind turbines and inverters, and provide the sequence impedance responses in only either MIMO or SISO form. This paper presents a sequence impedance measurement method that considers the frequency coupling, performs reference frame alignment, demonstrates the impact of the grid voltage angle estimation, and obtains the sequence impedance response in both MIMO and SISO forms. This paper demonstrates the proposed method and practical problems associated with the sequence impedance measurement of utility-scale wind turbines and inverters on a 1.9-MW Type III wind turbine and a 2.2-MVA inverter using an impedance measurement system built around a 7-MW/13.8-kV grid simulator and a 5-MW dynamometer.

17 WIND ENERGY↗

Generic Photovoltaic Inverter Model in an Electromagnetic Transients Simulator for Transmission Connected Plants

This report proposes a generic model specification of a photovoltaic inverter applied in transmission-connected plants for implementation in an electromagnetic transients simulator. The model specification contains the necessary control loops to meet the fault ride-through performance requirements in the IEEE 2800-2022 standard. The report details the implementation and example parameterization of the model in PSCAD™. Simulation results verify the model meets the performance requirements. Comparisons of the model’s response to laboratory test measurements of a commercial 2.2 MVA storage inverter show the model can reasonably predict the response of commercial equipment.

14 SOLAR ENERGY↗

Flight effects on the aerodynamic and acoustic characteristics of inverted profile coannular nozzles

The effect of forward flight on the jet noise of coannular exhaust nozzles, suitable for Variable Stream Control Engines (VSCE), was investigated in a series of wind tunnel tests. The primary stream properties were maintained constant at 300 mps and 394 K. A total of 230 acoustic data points was obtained. Force measurement tests using an unheated air supply covered the same range of tunnel speeds and nozzle pressure ratios on each of the nozzle configurations. A total of 80 points was taken. The coannular nozzle OASPL and PNL noise reductions observed statically relative to synthesized values were basically retained under simulated flight conditions. The effect of fan to primary stream area ratio on flight effects was minor. At take-off speed, the peak jet noise for a VSCE was estimated to be over 6 PNdB lower than the static noise level. High static thrust coefficients were obtained for the basic coannular nozzles, with a decay of 0.75 percent at take-off speeds.

Kozlowski, H.↗

Synchronization in electric power networks with inherent heterogeneity up to 100% inverter-based renewable generation

The synchronized operation of power generators is the foundation of electric power network stability and a key to the prevention of undesired power outages and blackouts. Here, we derive the conditions that guarantee synchronization in power networks with inherent generator heterogeneity when subjected to small perturbations, and perform a parametric sensitivity analysis to understand synchronization with varied types of generators. As inverter-based resources, which are the primary interfacing technology for many renewable sources of energy, have supplanted synchronous generators in ever growing numbers, the center of attention on associated integration challenges have resided primarily on the role of declining system inertia. Our results instead highlight the critical role of generator damping in achieving a stable state of synchronization. Additionally, we report the feasibility of operating interconnected electric grids with up to 100% power contribution from inverter-based renewable generation technologies. Our study has important implications as it sets the basis for the development of advanced control architectures and grid optimization methods that ensure synchronization and further pave the path towards the decarbonization of the electric power sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverter Anti-Islanding with Advanced Grid Support in Single- and Multi-Inverter Islands

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1. In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2. The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness.

14 SOLAR ENERGY↗

Power-Hardware-in-the-Loop Experiments of a Microgrid with a Grid-Forming Battery Inverter

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Definition study for photovoltaic residential prototype system

A parametric sensitivity study and definition of the conceptual design is presented. A computer program containing the solar irradiance, solar array, and energy balance models was developed to determine the sensitivities of solar insolation and the corresponding solar array output at five sites selected for this study as well as the performance of several solar array/battery systems. A baseline electrical configuration was chosen, and three design options were recommended. The study indicates that the most sensitive parameters are the solar insolation and the inverter efficiency. The baseline PST selected is comprised of a 133 sg m solar array, 250 ampere hour battery, one to three inverters, and a full shunt regulator to limit the upper solar array voltage. A minicomputer controlled system is recommended to provide the overall control, display, and data acquisition requirements. Architectural renderings of two photovoltaic residential concepts, one above ground and the other underground, are presented. The institutional problems were defined in the areas of legal liabilities during and after installation of the PST, labor practices, building restrictions and architectural guides, and land use.

Imamura, M. S.↗

Summary of GFL Inverter Capability and Performance: Malawi [Slides]

This presentation provides a comprehensive comparison of inverter-based resource (IBR) technical requirements across multiple international grid codes - including IEEE 2800, ESO, EirGrid, and Malawi's evolving regulatory framework - to support capacity building for electricity-sector institutions in Malawi. It highlights key performance expectations for grid-following (GFL) inverters across critical domains such as primary and fast frequency response, ramping behavior, frequency and voltage ride-through capabilities, reactive power and voltage control, ROCOF withstand, phase jump tolerance, system strength considerations, protection schemes, and dynamic modeling requirements. Emphasizing a "Do no harm, do something, do more" philosophy, the document synthesizes best practices and operational benchmarks to guide the integration and stability of inverter-based resources within Malawi's power system. The presentation forms part of the SABESS Center of Excellence initiative supported by the Global Energy Alliance for People and the Planet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Frequency Control Method for Islanded Microgrids Using Energy Storage Systems

Islanded microgrids are vulnerable to frequency fluctuations due to the presence of low-inertia distributed energy resources (DERs). Moreover, implementation of both synchronous-based and inverter-based DERs with a significant difference in inertia leads to a power imbalance between generation and consumption during transients. This results in frequency variations which might have severe consequences such as blackouts. This paper develops a control scheme for battery energy storage systems (BESSs) to enhance the dynamic response of islanded microgrids by mitigating the frequency fluctuations. A piecewise linear-elliptic (PLE) droop characteristic is proposed and employed in BESS to achieve a faster power balance between generation and consumption during transients, resulting in enhanced frequency responses. Different case studies are carried out to validate the viability of the proposed approach in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗

Characterization, Mechanism and Control Measures of V Segregation in Continuous Casting Billet of C-Mn Steel

To eliminate V segregation, which significantly deteriorates the homogeneity of continuous casting steel billets, V segregation in the C-Mn steel billet was observed by microscope, SEM and EDS. The formation mechanism and control measures for V segregation were proposed. Results show that many slim V segregation strips are distributed on an inverted conical surface and that most segregation strips start from the vertex of the inverted conical surface. A series of inverted conical surfaces containing V segregation strips periodically appears along the longitudinal direction of the billet. The microstructures in the V segregation strip are fine granular structures, while the microstructures outside the V segregation strip are coarse Widmanstätten. The V segregation strip also contains many inclusions and porosities. The formation mechanism for V segregation, which is illuminated by a physical simulation of Al-5wt pctCu alloy, is attributed to the fissure in the equiaxed dendritic network torn by solidification contraction. By controlling the percentage and distribution of equiaxed grains, the V segregation in the billet of C-Mn steel is completely eliminated.

36 MATERIALS SCIENCE↗