Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAOS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Femtosecond laser induced breakdown spectroscopy of Cu at the micron/sub-micron scale

While femtosecond Laser Induced Breakdown Spectroscopy has been studied in the macro-scale (i.e. ablation crater sizes of tens to hundreds of micrometers), the spectral emission mechanisms at the micron/sub-micron scale remain largely unknown, mainly because of the challenges associated with spectral emission acquisition from the limited amounts of ablated mass at these small lengthscales. In this work we study the limits of detection, the laser-induced plasma properties and spectral emission efficiency of Cu at the micron/submicron scale. Although the corresponding number electron densities and temperatures are similar to those reported for macroscale laser ablation, our findings suggest less efficient luminous spectral emission per ablated volume as we scale down in laser energy and crater sizes. Furthermore, these results provide a first insight into fs laser-induced plasma properties at the micron/sub-micron scale regime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond filament-laser ablation molecular isotopic spectrometry

A new remote sensing technology for real-time isotopic analysis is introduced: Femtosecond Filament-Induced Laser Ablation Molecular Isotopic Spectrometry (F 2 -LAMIS). The technique combines femtosecond (fs) laser filamentation and ablation-based molecular isotopic spectroscopy, thereby enabling isotopic analysis of samples at a distance, in ambient air and at ambient pressure conditions. Isotopic analysis of zirconium (Zr) samples by F 2 -LAMIS is demonstrated, and the molecular and atomic emission intensity, and properties of the filament-induced plasma generated at different filament propagation distances were investigated. Spectral fitting of F 2 -LAMIS spectra enabled semi-quantitative isotopic analysis without the use of calibration standards, which was independent of the filament propagation distance for the studied range. As a result, this technology provides new capabilities for direct isotopic ratio measurements at remote distances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reduction of spectral interferences and noise effects in laser ablation molecular isotopic spectrometry with partial least square regression – a computer simulation study

The fundamental analytical accuracies and precisions attainable by laser ablation molecular isotopic spectrometry (LAMIS), with emphasis on the impacts from spectral interferences and measurement noise, were investigated by means of computer simulation. The study focused on the analysis of a minor isotope at sub- to single-percentage abundance level. With a natural abundance about 1.1% for 13 C, the C 2 Swan band (d 3 II g - a 3 II u ) with Δν = + 1 was selected as a representative system. The characteristics (e.g., noise amplitude and distribution, signal strength, and signal-to-background ratio) of the simulated spectra were experimentally characterized. Partial least square (PLS) regression was used to extract isotopic information from the simulated molecular spectra. In the absence of any spectral interference and with the use of a calibration set consisting of eleven isotopic standards, the theoretical accuracies and precisions with signal accumulation from 100 laser shots are about 0.002% and 0.001%, respectively, in absolute percentage abundance of 13 C. The theoretical analytical accuracies slightly degrade, but are adequate for many applications, to 0.004% and 0.008% respectively, for calibrations involving only three and two isotopic standards. It was found that PLS regression is not only immune to both source-flicker and photon-shot noise, but is also effective in differentiating the spectral patterns from the analyte against those from spectral interferences. The influences of spectral interference from single or multiple atomic emission lines were simulated, and new ways to minimize their impacts were formulated and demonstrated. It was found that the wavelength range selected for the computation of the normalization factor should not contain any spectral-interfering peak, and a properly chosen wavelength range increases the tolerance of spectral interference by at least one order of magnitude. With matrix-matched calibration standards, the precisions (expressed as RSDs of the determined 13 C isotopic abundances) degrade from ~ 1% in the absence of spectral interference, to ~ 3&#8240, 10&#8240 and 20&#8240 with multiple spectral-interfering peaks that are 10 ×, 100 × and 1000 ×, respectively, stronger than the molecular bandhead of the analyte. The study concluded that PLS regression is a powerful and indispensable tool for extraction of isotopic information from LAMIS spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotopic determination of uranium in soil by laser induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) operated under ambient pressure has been evaluated for isotopic analysis of uranium in real-world samples such as soil, with U concentrations in the single digit percentage levels. The study addresses the requirements for spectral decomposition of 235 U and 238 U atomic emission peaks that are only partially resolved. Although non-linear least-square fitting algorithms are typically able to locate the optimal combination of fitting parameters that best describes the experimental spectrum even when all fitting parameters are treated as free independent variables, the analytical results of such an unconstrained free-parameter approach are ambiguous. In this work, five spectral decomposition algorithms were examined, with different known physical properties (e.g., isotopic splitting, hyperfine structure) of the spectral lines sequentially incorporated into the candidate algorithms as constraints. It was found that incorporation of such spectral-line constraints into the decomposition algorithm is essential for the best isotopic analysis. The isotopic abundance of 235 U was determined from a simple two-component Lorentzian fit on the U II 424.437 nm spectral profile. For six replicate measurements, each with only fifteen laser shots, on a soil sample with U concentration at 1.1% w/w, the determined 235 U isotopic abundance was (64.6 ± 4.8)%, and agreed well with the certified value of 64.4%. Another studied U line - U I 682.691 nm possesses hyperfine structure that is comparatively broad and at a significant fraction as the isotopic shift. Thus, 235 U isotopic analysis with this U I line was performed with spectral decomposition involving individual hyperfine components. For the soil sample with 1.1% w/w U, the determined 235 U isotopic abundance was (60.9 ± 2.0)%, which exhibited a relative bias about 6% from the certified value. The bias was attributed to the spectral resolution of our measurement system - the measured line width for this U I line was larger than its isotopic splitting. In conclusion, although not the best emission line for isotopic analysis, this U I emission line is sensitive for element analysis with a detection limit of 500 ppm U in the soil matrix; the detection limit for the U II 424.437 nm line was 2000 ppm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Internal mixing dynamics of Cu/Sn-Pb plasmas produced by femtosecond laser ablation

Chemical imaging applications using Laser Induced Breakdown Spectroscopy (LIBS) involve laser ablation sampling at interfaces or boundaries between materials with different thermophysical and optical properties, leading to the formation of two initially isolated plasmas. The mechanisms of mixing in these plasmas and their direct implications on spectral emission and chemical imaging remain largely unknown. We investigate the mixing dynamics of isolated plasmas produced using femtosecond (fs) laser pulses at the interface between two different model Cu and Sn–Pb samples. Specifically, we study the spatial and temporal mixing dynamics and outer plasma expansion dynamics of the fs plasma components. The time-resolved degree of component mixing, horizontal and vertical expansion, mixing speed, and temperature and electron density of the heterogeneous plasma are characterized. Mixing processes are initiated early on, <100 ns after the laser pulse, and continue taking place until the end of plasma emission persistence at a constant velocity of 10 4 cm/s. In conclusion, these findings demonstrate that proper selection of detection timing parameters and signal collection position are critically important in precise LIBS measurements to ensure that full plasma mixing has taken place and that homogeneous spectral emission is properly detected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analytical characterization of laser induced plasmas towards uranium isotopic analysis in gaseous uranium hexafluoride

To perform direct enrichment assay on gaseous uranium hexafluoride (UF 6 ) with laser induced breakdown spectroscopy (LIBS), the dominant spectral-line features, evolution of the signal and background of the U II 424.437 nm line, and its Stark width and shift, were studied as a function of UF 6 gas pressure and pulse energy of a nanosecond Nd:YAG laser. In this work, vapor pressure of UF 6 was found to be the most important parameter for LIBS analysis of gaseous UF 6 . Spectral congestion with numerous U lines of high excitation potential was observed and signal-to-background ratio (SBR) was low for measurements with 80 Torr UF 6 . Only when both UF 6 vapor pressure and laser pulse energy were low, for example, less than 20 Torr pressure and 30 mJ pulse energy, the resultant LIBS spectra from gaseous UF 6 resembled those obtained from solid U samples. The experimental data also suggest that U and F atoms recombine back to UF 6 after the laser pulse. The U emission was found to decay fast with a persistent background signal, degrading SBR with delay time. Systematic positive biases were found for UF 6 enrichment assays performed with the 235 U– 238 U line pair at 424.412–424.437 nm, which was confirmed to be caused by self-absorption. Even with optimization of experimental parameters and incorporation of a self-absorption term into the spectral-fitting algorithm, to reduce and compensate for self-absorption, self-absorption is still a main factor limiting accurate UF 6 enrichment assay. The use of another spectral window which contains no resonance lines is a prospective solution for the self-absorption issue.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

Remote isotope detection and quantification using femtosecond filament-laser ablation molecular isotopic spectrometry

We demonstrate the detection and quantification of isotopes from solid samples remotely at a distance of 36 m. This was accomplished through the combination of femtosecond filaments and laser ablation molecular isotopic spectrometry (F 2 -LAMIS). Isotopically enriched graphite samples with varying 13 C concentration were used and the F 2 -LAMIS emission was measured remotely using a portable spectrometer system. A standardless quantification approach was used to determine the corresponding isotopic ratios. The use of F 2 -LAMIS for the detection and quantification of isotopes at atmospheric pressure without the use of calibration standards opens the possibility to implement this technology for remote sensing of isotopes in field applications

07 ISOTOPE AND RADIATION SOURCES↗

Chemistry and P-V-T equation of state of FeO 2 H x at the base of Earth’s lower mantle and their geophysical implications

The hydrogen-absorbing ability of a mantle mineral in its structure determines the capacity of the water reservoirs hosted by the mineral. Water reservoirs at the base of Earth’s mantle directly influence the fate of water brought down by slab subduction and the seismic heterogeneity such as ultralow-velocity zones (ULVZs) at the core-mantle boundary. Pyrite-FeO 2 H x (0 ≤ x ≤ 1) presents a possibility of such reservoirs in the deep mantle. Ever since the discovery of this mineral phase, however, its chemistry at the lower mantle conditions has been debated. We conducted kinetics experiments of pyrite-FeO 2 H x dehydrogenation at 110 GPa/2100 K, 110 GPa/2300 K, and 120 GPa/2300 K and P-V-T equation of state analysis using in situ synchrotron X-ray diffraction. We found that x approaches 0.80, 0.75, and 0.79, respectively, at the above conditions. The collective P-V-T data yield K 0 = 241(13) GPa, K' = 4.2(4), dK/dT = –0.028(1) GPa/K, α 0 = 4.32(13) × 10 –5 K –1 , and α 1 = 0.31(10) × 10 –8 K –2 for the composition of x = 0.75 ± 0.04. Our first-principles calculations indicate that FeO 2 H 0.75 with a slightly distorted pyrite structure is stable at 100 GPa. These results indicate that this mineral is likely present in the deep mantle with rather a partially dehydrogenated composition than FeO 2 or FeOOH. Furthermore, the results also clarify the difference between the ULVZs originated from pyrite-FeO 2 H x and those from partial melting in terms of shear and compressional wave seismic velocity reduction ratio δlnV S /δlnV P .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The stability of FeH x and hydrogen transport at Earth’s core mantle boundary

Iron hydride in Earth’s interior can be formed by the reaction between hydrous minerals (water) and iron. Studying iron hydride improves our understanding of hydrogen transportation in Earth’s interior. Our high-pressure experiments found that face-centered cubic (fcc) FeH x (x≤1) is stable up to 165 GPa, and our ab initio molecular dynamics simulations predicted that fcc FeH x transforms to a superionic state under lower mantle conditions. In the superionic state, H-ions in fcc FeH become highly diffusive-like fluids with a high diffusion coefficient of ~3.7 × 10 -4 cm 2 s -1 , which is comparable to that in the liquid Fe-H phase. The densities and melting temperatures of fcc FeH x were systematically calculated. Similar to superionic ice, the extra entropy of diffusive H-ions increases the melting temperature of fcc FeH. Further, the wide stability field of fcc FeH enables hydrogen transport into the outer core to create a potential hydrogen reservoir in Earth’s interior, leaving oxygen-rich patches (ORP) above the core mantle boundary (CMB).

58 GEOSCIENCES↗

A comprehensive analysis of the crop effect on the urban-rural differences in land surface phenology

The response of land surface phenology (LSP) to the urban heat island effect (UHI) is a useful biological indicator for understanding how vegetated ecosystems will be affected by future climate warming. However, vegetation cover in rural areas is often dominated by cultivated land, whose phenological timing is considerably influenced by agricultural managements (e.g., timing of sowing and harvesting), leading to biased conclusions derived from the urban-rural LSP differences. To demonstrate this problem, we investigated the crop influence on the phenological response to a warmer environment resulting from the UHI effect. We partitioned cities in the United States into cultivated and non-cultivated categories according to the proportion of crops in rural areas. We then built continuous buffer zones starting from the urban boundary to explore the urban-rural LSP differences considering the UHI effect on them. In this work, the results suggest crop inclusion is likely to lead to >14 days of urban-rural differences at both the start of the season (SOS) and the end of the season (EOS) between cultivated and non-cultivated cities. The temperature sensitivity (ST) of SOS is overestimated by approximately 2.7 days/°C, whereas the EOS is underestimated by 3.6 days/°C. Removing crop-dominated pixels (i.e., above 50 %) can minimize the influence of crop planting/harvesting on LSP and derive reliable results. We, therefore, suggest explicit consideration of crop impacts in future studies of phenological differences between urban and rural areas and the UHI effect on LSP in urban domains, as presented by this comprehensive study.

54 ENVIRONMENTAL SCIENCES↗