Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Commissioning a CT-compatible LDR tandem and ovoid applicator using Monte Carlo calculation and 3D dosimetry

Purpose: To determine the geometric and dose attenuation characteristics of a new commercially available CT-compatible LDR tandem and ovoid (T and O) applicator using Monte Carlo calculation and 3D dosimetry. Methods: For geometric characterization, we quantified physical dimensions and investigated a systematic difference found to exist between nominal ovoid angle and the angle at which the afterloading buckets fall within the ovoid. For dosimetric characterization, we determined source attenuation through asymmetric gold shielding in the buckets using Monte Carlo simulations and 3D dosimetry. Monte Carlo code MCNP5 was used to simulate 1.5 Multiplication-Sign 10{sup 9} photon histories from a {sup 137}Cs source placed in the bucket to achieve statistical uncertainty of 1% at a 6 cm distance. For 3D dosimetry, the distribution about an unshielded source was first measured to evaluate the system for {sup 137}Cs, after which the distribution was measured about sources placed in each bucket. Cylindrical PRESAGE{sup Registered-Sign} dosimeters (9.5 cm diameter, 9.2 cm height) with a central channel bored for source placement were supplied by Heuris Inc. The dosimeters were scanned with the Duke Large field of view Optical CT-Scanner before and after delivering a nominal dose at 1 cm of 5-8 Gy. During irradiation the dosimeter was placed in a water phantom to provide backscatter. Optical CT scan time lasted 15 min during which 720 projections were acquired at 0.5 Degree-Sign increments, and a 3D distribution was reconstructed with a (0.05 cm){sup 3} isotropic voxel size. The distributions about the buckets were used to calculate a 3D distribution of transmission rate through the bucket, which was applied to a clinical CT-based T and O implant plan. Results: The systematic difference in bucket angle relative to the nominal ovoid angle (105 Degree-Sign ) was 3.1 Degree-Sign -4.7 Degree-Sign . A systematic difference in bucket angle of 1 Degree-Sign , 5 Degree-Sign , and 10 Degree-Sign caused a 1%{+-} 0.1%, 1.7%{+-} 0.4%, and 2.6%{+-} 0.7% increase in rectal dose, respectively, with smaller effect to dose to Point A, bladder, sigmoid, and bowel. For 3D dosimetry, 90.6% of voxels had a 3D {gamma}-index (criteria = 0.1 cm, 3% local signal) below 1.0 when comparing measured and expected dose about the unshielded source. Dose transmission through the gold shielding at a radial distance of 1 cm was 85.9%{+-} 0.2%, 83.4%{+-} 0.7%, and 82.5%{+-} 2.2% for Monte Carlo, and measurement for left and right buckets, respectively. Dose transmission was lowest at oblique angles from the bucket with a minimum of 56.7%{+-} 0.8%, 65.6%{+-} 1.7%, and 57.5%{+-} 1.6%, respectively. For a clinical T and O plan, attenuation from the buckets leads to a decrease in average Point A dose of {approx}3.2% and decrease in D{sub 2cc} to bladder, rectum, bowel, and sigmoid of 5%, 18%, 6%, and 12%, respectively. Conclusions: Differences between dummy and afterloading bucket position in the ovoids is minor compared to effects from asymmetric ovoid shielding, for which rectal dose is most affected. 3D dosimetry can fulfill a novel role in verifying Monte Carlo calculations of complex dose distributions as are common about brachytherapy sources and applicators.

61 RADIATION PROTECTION AND DOSIMETRY↗

Upsampling Monte Carlo reactor simulation tallies in depleted LWR assemblies fueled with LEU and HALEU using a convolutional neural network

Simulating nuclear reactor cores at the highest achievable spatial and energy resolution is critical in modeling these systems accurately. Increasing the resolution, however, can dramatically increase the memory and central processing unit time required to run simulations. A convolutional neural network was shown previously to accurately upsample tally results of simulated light water reactor assemblies fueled with fresh, low enriched uranium. Here, we show that a convolutional neural network can be used to upsample tally results in assemblies containing fresh and depleted fuel enriched from 1.6 to 19.9 atom percent. The network was trained using neutron flux tallies from simulations of light water reactor assemblies with a range of fuel and coolant temperatures and a diverse selection of geometries. Accurate predictions of flux tallies are possible even on test assemblies with geometries and burnup levels well outside the range of those present in the training and validation data. The network improves the data density by a factor of 8 over a broad range of light water reactor assemblies while incurring insignificant additional computational cost to a Monte Carlo simulation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte Carlo calculation of monitor unit for electron arc therapy

Purpose: Monitor unit (MU) calculations for electron arc therapy were carried out using Monte Carlo simulations and verified by measurements. Variations in the dwell factor (DF), source-to-surface distance (SSD), and treatment arc angle ({alpha}) were studied. Moreover, the possibility of measuring the DF, which requires gantry rotation, using a solid water rectangular, instead of cylindrical, phantom was investigated. Methods: A phase space file based on the 9 MeV electron beam with rectangular cutout (physical size=2.6x21 cm{sup 2}) attached to the block tray holder of a Varian 21 EX linear accelerator (linac) was generated using the EGSnrc-based Monte Carlo code and verified by measurement. The relative output factor (ROF), SSD offset, and DF, needed in the MU calculation, were determined using measurements and Monte Carlo simulations. An ionization chamber, a radiographic film, a solid water rectangular phantom, and a cylindrical phantom made of polystyrene were used in dosimetry measurements. Results: Percentage deviations of ROF, SSD offset, and DF between measured and Monte Carlo results were 1.2%, 0.18%, and 1.5%, respectively. It was found that the DF decreased with an increase in {alpha}, and such a decrease in DF was more significant in the {alpha} range of 0 deg. - 60 deg. than 60 deg. - 120 deg. Moreover, for a fixed {alpha}, the DF increased with an increase in SSD. Comparing the DF determined using the rectangular and cylindrical phantom through measurements and Monte Carlo simulations, it was found that the DF determined by the rectangular phantom agreed well with that by the cylindrical one within {+-}1.2%. It shows that a simple setup of a solid water rectangular phantom was sufficient to replace the cylindrical phantom using our specific cutout to determine the DF associated with the electron arc. Conclusions: By verifying using dosimetry measurements, Monte Carlo simulations proved to be an alternative way to perform MU calculations effectively for electron arc therapy. Since Monte Carlo simulations can generate a precalculated database of ROF, SSD offset, and DF for the MU calculation, with a reduction in human effort and linac beam-on time, it is recommended that Monte Carlo simulations be partially or completely integrated into the commissioning of electron arc therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-E-BRE-06: Challenges in the Dosimetry of Flattening Filter Free Beams

Purpose: In current dosimetry protocols [AAPM TG51, IAEA TRS-389] the beam quality correction factor kQ and the water-to-air restricted mass collision stopping-power ratio SPR are related to beam quality specifiers %dd(10){sub x} respectively TPR{sub 20,10} Determining kQ and SPR using these regular beam quality specifiers for conventional accelerators (WFF) and flattening filter free accelerators (FFF) similarly could lead to systemic bias.The influence of the flattening filter on the relationship between various beam quality specifiers and SPR respectively k{sub Q} was studied using Monte Carlo simulations with realistic beam sources. Methods: All Monte Carlo simulations were performed using the BEAMnrc/EGSnrc code system. Radiation transport through nine linear accelerator heads modeled according to technical drawings given by the manufactures and a {sup 60} Co therapy source was simulated with BEAMnrc and then used as a radiation source for further simulations. FFF beam sources were implemented by removing the fattening filter from the WFF model. SPR was calculated applying the user code SPRRZnrc. The mean photon energy below the accelerator head and the mean energies of photons and electrons at the measuring point within the water phantom were calculated using FLURZnrc. Dose calculations within a small water voxel and the thimble ionization chamber PTW-31010 in a water depth of 10 cm were made using the egs-chamber code. Results: SPR and k{sub Q} as a function of fluence spectra based beam quality specifiers as well as conventional beam quality specifiers differ systematically between FFF and WFF beams. According to the results the specifier %dd(10){sub x} revealed the smallest deviation (max. 0.4%) between FFF and WFF beams. Conclusion: The results show that %dd(10){sub x} is an acceptable beam quality specifier for FFF beams. Nevertheless the results confirm the expected bias between FFF and WFF beams which must by further investigated.

07 ISOTOPE AND RADIATION SOURCES↗

Small field in-air output factors: The role of miniphantom design and dosimeter type

Purpose: The commissioning of treatment planning systems and beam modeling requires measured input parameters. The measurement of relative output in-air, S{sub c} is particularly difficult for small fields. The purpose of this study was to investigate the influence of miniphantom design and detector selection on measured S{sub c} values for small fields and to validate the measurements against Monte Carlo simulations. Methods: Measurements were performed using brass caps (with sidewalls) or tops (no sidewalls) of varying heights and widths. The performance of two unshielded diodes (60012 and SFD), EBT2 radiochromic film, and a fiber optic dosimeter (FOD) were compared for fields defined by MLCs (5–100 mm) and SRS cones (4–30 mm) on a Varian Novalis linear accelerator. Monte Carlo simulations were performed to theoretically predict S{sub c} as measured by the FOD. Results: For all detectors, S{sub c} agreed to within 1% for fields larger than 10 mm and to within 2.3% for smaller fields. Monte Carlo simulation matched the FOD measurements for all size of cone defined fields to within 0.5%. Conclusions: Miniphantom design is the most important variable for reproducible and accurate measurements of the in-air output ratio, S{sub c}, in small photon fields (less than 30 mm). Sidewalls are not required for fields ≤ 30 mm and tops are therefore preferred over the larger caps. Unlike output measurements in water, S{sub cp,} the selection of detector type for S{sub c} is not critical, provided the active dosimeter volume is small relative to the field size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uncertainties in greenhouse gas emission factors: A comprehensive analysis of switchgrass‐based biofuel production

Abstract This study investigates uncertainties in greenhouse gas (GHG) emission factors related to switchgrass‐based biofuel production in Michigan. Using three life cycle assessment (LCA) databases—US lifecycle inventory (USLCI) database, GREET, and Ecoinvent—each with multiple versions, we recalculated the global warming intensity (GWI) and GHG mitigation potential in a static calculation. Employing Monte Carlo simulations along with local and global sensitivity analyses, we assess uncertainties and pinpoint key parameters influencing GWI. The convergence of results across our previous study, static calculations, and Monte Carlo simulations enhances the credibility of estimated GWI values. Static calculations, validated by Monte Carlo simulations, offer reasonable central tendencies, providing a robust foundation for policy considerations. However, the wider range observed in Monte Carlo simulations underscores the importance of potential variations and uncertainties in real‐world applications. Sensitivity analyses identify biofuel yield, GHG emissions of electricity, and soil organic carbon (SOC) change as pivotal parameters influencing GWI. Decreasing uncertainties in GWI may be achieved by making greater efforts to acquire more precise data on these parameters. Our study emphasizes the significance of considering diverse GHG factors and databases in GWI assessments and stresses the need for accurate electricity fuel mixes, crucial information for refining GWI assessments and informing strategies for sustainable biofuel production.

Kim, Seungdo↗

SU-E-T-565: RAdiation Resistance of Cancer CElls Using GEANT4 DNA: RACE

Purpose: The objective of the RACE project is to develop a comparison between Monte Carlo simulation using the Geant4-DNA toolkit and measurements of radiation damage on 3D melanoma and chondrosarcoma culture cells coupled with gadolinium nanoparticles. We currently expose the status of the developments regarding simulations. Methods: Monte Carlo studies are driven using the Geant4 toolkit and the Geant4-DNA extension. In order to model the geometry of a cell population, the opensource CPOP++ program is being developed for the geometrical representation of 3D cell populations including a specific cell mesh coupled with a multi-agent system. Each cell includes cytoplasm and nucleus. The correct modeling of the cell population has been validated with confocal microscopy images of spheroids. The Geant4 Livermore physics models are used to simulate the interactions of a 250 keV X-ray beam and the production of secondaries from gadolinium nanoparticles supposed to be fixed on the cell membranes. Geant4-DNA processes are used to simulate the interactions of charged particles with the cells. An atomistic description of the DNA molecule, from PDB (Protein Data Bank) files, is provided by the so-called PDB4DNA Geant4 user application we developed to score energy depositions in DNA base pairs and sugar-phosphate groups. Results: At the microscopic level, our simulations enable assessing microscopic energy distribution in each cell compartment of a realistic 3D cell population. Dose enhancement factors due to the presence of gadolinium nanoparticles can be estimated. At the nanometer scale, direct damages on nuclear DNA are also estimated. Conclusion: We successfully simulated the impact of direct radiations on a realistic 3D cell population model compatible with microdosimetry calculations using the Geant4-DNA toolkit. Upcoming validation and the future integration of the radiochemistry module of Geant4-DNA will propose to correlate clusters of ionizations with in vitro experiments. All those developments will be released publicly. This work was supported by grants from Plan Cancer 2009-2013 French national initiative managed by INSERM (Institut National de la Sante et de la Recherche Medicale)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-BRB-02: Towards Quantitative Clinical Decision On Deep Inspiration Breath Hold (DIBH) Or Prone for Left-Sided Breast Irradiation

Purpose: To develop quantitative clinical guidelines between supine Deep Inspiratory Breath Hold (DIBH) and prone free breathing treatments for breast patients, we applied 3D deformable phantoms to perform Monte Carlo simulation to predict corresponding Dose to the Organs at Risk (OARs). Methods: The RPI-adult female phantom (two selected cup sizes: A and D) was used to represent the female patient, and it was simulated using the MCNP6 Monte Carlo code. Doses to OARs were investigated for supine DIBH and prone treatments, considering two breast sizes. The fluence maps of the 6-MV opposed tangential fields were exported. In the Monte Carlo simulation, the fluence maps allow each simulated photon particle to be weighed in the final dose calculation. The relative error of all dose calculations was kept below 5% by simulating 3*10{sup 7} photons for each projection. Results: In terms of dosimetric accuracy, the RPI Adult Female phantom with cup size D in DIBH positioning matched with a DIBH treatment plan of the patient. Based on the simulation results, for cup size D phantom, prone positioning reduced the cardiac dose and the dose to other OARs, while cup size A phantom benefits more from DIBH positioning. Comparing simulation results for cup size A and D phantom, dose to OARs was generally higher for the large breast size due to increased scattering arising from a larger portion of the body in the primary beam. The lower dose that was registered for the heart in the large breast phantom in prone positioning was due to the increase of the distance between the heart and the primary beam when the breast was pendulous. Conclusion: Our 3D deformable phantom appears an excellent tool to predict dose to the OARs for the supine DIBH and prone positions, which might help quantitative clinical decisions. Further investigation will be conducted. National Institutes of Health R01EB015478.

60 APPLIED LIFE SCIENCES↗

Nonequilibrium gas flows. I - A detailed validation of Monte Carlo direct simulation for monatomic gases

One-dimensional shock wave properties in helium and argon are predicted using Monte Carlo direct simulation. The collision model is based directly on the interatomic potential taking angular scattering into account. The potential is assumed to be of the Maitland-Smith n(r)-6 form. The detailed validity of the simulation is studied by comparing the predicted macroscopic and miroscopic flow properties in shock waves to a wide range of available data.

Erwin, Daniel A.↗

Extension of the quantum-kinetic model to lunar and Mars return physics

The ability to compute rarefied, ionized hypersonic flows is becoming more important as missions such as Earth reentry, landing high-mass payloads on Mars, and the exploration of the outer planets and their satellites are being considered. A recently introduced molecular-level chemistry model, the quantum-kinetic, or Q-K, model that predicts reaction rates for gases in thermal equilibrium and non-equilibrium using only kinetic theory and fundamental molecular properties, is extended in the current work to include electronic energy level transitions and reactions involving charged particles. Like the Q-K procedures for neutral species chemical reactions, these new models are phenomenological procedures that aim to reproduce the reaction/transition rates but do not necessarily capture the exact physics. These engineering models are necessarily efficient due to the requirement to compute billions of simulated collisions in direct simulation Monte Carlo (DSMC) simulations. The new models are shown to generally agree within the spread of reported transition and reaction rates from the literature for near equilibrium conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical analysis for finite-range multitype stochastic contact financial market dynamic systems

In an attempt to reproduce and study the dynamics of financial markets, a random agent-based financial price model is developed and investigated by the finite-range multitype contact dynamic system, in which the interaction and dispersal of different types of investment attitudes in a stock market are imitated by viruses spreading. With different parameters of birth rates and finite-range, the normalized return series are simulated by Monte Carlo simulation method and numerical studied by power-law distribution analysis and autocorrelation analysis. To better understand the nonlinear dynamics of the return series, a q-order autocorrelation function and a multi-autocorrelation function are also defined in this work. The comparisons of statistical behaviors of return series from the agent-based model and the daily historical market returns of Shanghai Composite Index and Shenzhen Component Index indicate that the proposed model is a reasonable qualitative explanation for the price formation process of stock market systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Elucidating grain boundary energy minimization mechanisms in textured Ca-doped alumina with inclination-dependent Monte Carlo Potts simulations

The grain growth behavior of textured Ca-doped alumina is compared to Monte Carlo Potts (MCP) simulations to investigate the effect of anisotropic grain boundary (GB) properties on local boundary migration. Experimentally, the growth of textured Ca-doped alumina results in highly elongated grains. The relative GB energy distribution is measured using the thermal groove method before and after heat treating at 1600°C, finding that high energy GBs are eliminated during grain growth. No significant difference in the GB energy distributions is found between the long and short axes of the elongated grains, suggesting that anisotropic mobility may be responsible for the grain shape. However, MCP simulations with anisotropic mobility as a function of plane inclination do not result in grains with distinct morphologies, regardless of the degree of anisotropy introduced. The final grain shape after grain growth of textured Ca-doped alumina resembles that of the MCP simulations using an anisotropic GB energy as a cosine function of plane inclination. Several energy functions are tested and only those that mathematically impose a torque (second derivative of energy with respect to the plane inclination angle) result in elongated grains. Although area reduction is the dominant energy minimization mechanism, these results suggest that local GB migration is affected by anisotropic GB energy and torque and alternative mechanisms like GB replacement and reorientation.

36 MATERIALS SCIENCE↗

A hybrid approach to the neutron transport K-eigenvalue problem using NDA-based algorithms

In order to provide more physically accurate solutions to the neutron transport equation it has become increasingly popular to use Monte Carlo simulation to model nuclear reactor dynamics. These Monte Carlo methods can be extremely expensive, so we turn to a class of methods known as hybrid methods, which combine known deterministic and stochastic techniques to solve the transport equation. In our work, we show that we can simulate the action of a transport sweep using a Monte Carlo simulation in order to solve the k-eigenvalue problem. We'll accelerate the solution using nonlinear diffusion acceleration (NDA) as in [1,2]. Our work extends the results in [1] to use Monte Carlo simulation as the high-order solver. (authors)

97 MATHEMATICS AND COMPUTING↗

SU-E-J-201: Investigation of MRI Guided Proton Therapy

Purpose: Image-guided radiation therapy has been employed for cancer treatment to improve the tumor localization accuracy. Radiation therapy with proton beams requires more on this accuracy because the proton beam has larger uncertainty and dramatic dose variation along the beam direction. Among all the image modalities, magnetic-resonance image (MRI) is the best for soft tissue delineation and real time motion monitoring. In this work, we investigated the behavior of the proton beam in magnetic field with Monte Carlo simulations. Methods: A proton Monte Carlo platform, TOPAS, was used for this investigation. Dose calculations were performed with this platform in a 30cmx30cmx30cm water phantom for both pencil and broad proton beams with different energies (120, 150 and 180MeV) in different magnetic fields (0.5T, 1T and 3T). The isodose distributions, dose profiles in lateral and beam direction were evaluated. The shifts of the Bragg peak in different magnetic fields for different proton energies were compared and the magnetic field effects on the characters of the dose distribution were analyzed. Results: Significant effects of magnetic field have been observed on the proton beam dose distributions, especially for magnetic field of 1T and up. The effects are more significant for higher energy proton beam because higher energy protons travel longer distance in the magnetic field. The Bragg peak shift in the lateral direction is about 38mm for 180MeV and 11mm for 120MeV proton beams in 3T magnetic field. The peak positions are retracted back for 6mm and 2mm, respectively. The effect on the beam penumbra and dose falloff at the distal edge of the Bragg peak is negligible. Conclusion: Though significant magnetic effects on dose distribution have been observed for proton beams, MRI guided proton therapy is feasible because the magnetic effects on dose is predictable and can be considered in patient dose calculation.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-08: New Compact 10 MV S-Band Linear Accelerator: 3D Finite-Element Design and Monte Carlo Dose Simulations

Purpose: To design a new compact S-band linac waveguide capable of producing a 10 MV x-ray beam, while maintaining the length (27.5 cm) of current 6 MV waveguides. This will allow higher x-ray energies to be used in our linac-MRI systems with the same footprint. Methods: Finite element software COMSOL Multiphysics was used to design an accelerator cavity matching one published in an experiment breakdown study, to ensure that our modeled cavities do not exceed the threshold electric fields published. This cavity was used as the basis for designing an accelerator waveguide, where each cavity of the full waveguide was tuned to resonate at 2.997 GHz by adjusting the cavity diameter. The RF field solution within the waveguide was calculated, and together with an electron-gun phase space generated using Opera3D/SCALA, were input into electron tracking software PARMELA to compute the electron phase space striking the x-ray target. This target phase space was then used in BEAM Monte Carlo simulations to generate percent depth doses curves for this new linac, which were then used to re-optimize the waveguide geometry. Results: The shunt impedance, Q-factor, and peak-to-mean electric field ratio were matched to those published for the breakdown study to within 0.1% error. After tuning the full waveguide, the peak surface fields are calculated to be 207 MV/m, 13% below the breakdown threshold, and a d-max depth of 2.42 cm, a D10/20 value of 1.59, compared to 2.45 cm and 1.59, respectively, for the simulated Varian 10 MV linac and brehmsstrahlung production efficiency 20% lower than a simulated Varian 10 MV linac. Conclusion: This work demonstrates the design of a functional 27.5 cm waveguide producing 10 MV photons with characteristics similar to a Varian 10 MV linac.

07 ISOTOPE AND RADIATION SOURCES↗

Am-241 Nuclear Safety and Environmental Interactions

NASA’s supply of radioisotopes for Radioisotope Heat Units (RHU) and Radioisotope Thermoelectric Generator (RTG) power sources is facing a crisis due to shortages of Pu-238 for future missions. Am-241 is a possible replacement for Pu-238 since its stockpile from the nuclear weapons program has remained relatively intact. The purpose of this project was to assess the safety of Am-241 and the risks associated with it as compared with PU-238. The project has resulted in a journal article, F. De-La-Torre-Aguilar, N. White, M. Prelas, R. V. Tompson, and S. K. Loyalka "Space nuclear power system accidents: Doses from Pu-238 and Am- 241 inhalation," Progress in Nuclear Energy vol.100C (2017), pp.171-182, which showed that the radiation dosage resulting from Am-241 inhalation are about 1/2.5 of the dosage resulting from Pu-238 inhalation per KW of Pu-238 power. Considerable progress was also made on the Direct Simulation Monte Carlo Method (DSMC) for simulation of aerosol evolution during accidents resulting in three publications: 1.I. Saldivar, F. De-La-Torre-Aguilar, M. Boraas, and S. K. Loyalka “Benchmark problems in aerosol evolution: Comparison of some exact and DSMC results” in Annals of Nuclear Energy vol.117 (2018), pp.213-222. 2. I. Saldivar and S. K. Loyalka, “Evolution of Aerosols Coupled to Environments: Verification of Direct Simulation Monte Carlo (DSMC)”, Nuclear Technology 204 (2018), pp.172-183. 3. M. Boraas and S. K. Loyalka, “Mesh Free Simulation of Spatially Inhomogeneous aerosols in Arbitrary Geometries” Nuclear Science and Engineering (2018). Further, we have computations on Am-241/Pu-238 vapor and aerosol interactions, and found that the vapor condensation rate is relatively insensitive to the mass effects, confirming some previous results. We have also completed computations of charge effects on evolution of different species aerosols and a manuscript is in preparation. Additionally, we have compared atmospheric dispersion and deposition of Pu-238 and Am-241 using the HYSPLIT code. We have also used a real lung model and the CFD program FLUENT to compute PuO2 and AmO2 deposition to explore improvements upon the ICPR-66 model. We have found that the deposition efficiencies of PuO2 and AmO2 are similar. These results (four manuscripts) will be submitted for publication in the post project period. We have made progress using framework of Mars 2020 mission nuclear risk assessment model to integrate all results, but our progress has been limited as the improved consequence modeling itself has been quite involved and challenging. We will integrate and complete the more extensive risk modeling computations and publish the results in the post-project period. In addition to the above, the project has resulted in research training of four PhD students

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development and Validation of a Geant4 Radiation Shielding Simulation Framework

Geant4 (`Geometry and Tracking') is a C++ Monte- Carlo simulation toolkit developed by the Geant4 Collaboration under CERN and is used to describe inter- actions between particles and matter. It has been shown, through significant benchmarking against physical experiments and other software, to be remarkably accurate at simulating interactions between particles and matter. Currently, Geant4 is being used on world-wide projects such as ATLAS, CMS, Muon g-2, and ILC, largely due to being accurate, open-source, and written in a modern language. This openness and modernity is striking when compared to other Monte-Carlo simulation toolkits such as the Fortran toolkit MCNP (Monte-Carlo N-Particle code), which is restricted in acquisition and use by the US government. Despite barriers in the use of MCNP and having been written in an antiquated language, MCNP is still considered industry-standard for many fields, including radiation shielding. This paper details the development and validation of a radiation shielding simulation framework in Geant4 aimed at flexibility and ease of simulations with the goal of replacing MCNP scripts.

43 PARTICLE ACCELERATORS↗

THE DiskMass SURVEY. III. STELLAR KINEMATICS VIA CROSS-CORRELATION

We describe a new cross-correlation (CC) approach used by our survey to derive stellar kinematics from galaxy-continuum spectroscopy. This approach adopts the formal error analysis derived by Statler, but properly handles spectral masks. Thus, we address the primary concerns regarding application of the CC method to censored data, while maintaining its primary advantage by consolidating kinematic and template-mismatch information toward different regions of the CC function. We identify a systematic error in the nominal CC method of approximately 10% in velocity dispersion incurred by a mistreatment of detector-censored data, which is eliminated by our new method. We derive our approach from first principles, and we use Monte Carlo simulations to demonstrate its efficacy. An identical set of Monte Carlo simulations performed using the well-established penalized-pixel-fitting code of Cappellari and Emsellem compares favorably with the results from our newly implemented software. Finally, we provide a practical demonstration of this software by extracting stellar kinematics from SparsePak spectra of UGC 6918.

79 ASTRONOMY AND ASTROPHYSICS↗