Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Theoretical Studies of Spectral Properties of Plutonium

By combining the local density approximation (LDA) with dynamical mean field theory (DMFT), we report a systematic analysis of the spectral properties of {delta}-plutonium with varying 5f occupancy. The LDA Hamiltonian is extracted from a tight-binding (TB) fit to full-potential linearized augmented plane-wave (FP-LAPW) calculations. The DMFT equations are solved by the exact quantum Monte Carlo (QMC) method and the Hubbard-I approximation. We show the strong sensitivity of the spectral properties to the 5f occupancy, which suggests using this occupancy as a fitting parameter in addition to the Hubbard U. By comparing with PES data, we conclude that the 'open shell' 5f{sup 5} configuration gives the best agreement, resolving the controversy over 5f 'open shell' versus 'close shell' atomic configurations in {delta}-Pu. (authors)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Freewheeling: What Six Locations, 61,000 Trips, and 242,000 Miles in Colorado Reveal about How E-Bikes Improve Mobility Options

Personal micromobility modes such as bicycles, e-bikes and scooters offer low- or zero-emission transportation alternatives to single occupancy vehicles (SOVs). However, the lack of supporting data has led to a dearth of data-driven research on the usage of personally owned e-bikes, including variations due to weather, geography and demographics. In this paper, we present an overview of the longitudinal findings from the CanBikeCO program, focused on e-bike adoption and use rates across different demographics, trip characteristics, and geographies. The CanBikeCO program recorded travel survey data from late July 2021 to December 31, 2022, from low-income Colorado households who were provided with e-bikes for personal use by the Colorado Energy Office (CEO). This data was collected in six different communities across Colorado following the mini-pilot program that was conducted in Fall 2020. To collect data for the survey, the program used the NREL OpenPATH application, which combines passive data collection with semantic information such as trip mode and purpose labels. To the best of our knowledge, there is no prior travel survey data on personally owned e-bikes with this range and scope. This unique dataset yielded several insights. One is that commute trips among participants had nearly 17% higher shares of e-bikes than all trips combined. E-bikes were stated to most often replace cars (34% of e-bike trips) and personal micromobility (22%). Participants favored walking for trips less than 1 mile, e-bikes for trips 1-3 miles, and e-bikes, cars or shared rides for trips 3-20 miles. Seasonality accounted for a 10% decrease and subsequent recovery in e-bike mileage on a per user basis. E-bikes are also appealing across age groups, even among older individuals, and see decreased utilization similar to regular bikes or walking during winter months. We also find that e-bike use may be related to characteristics of land use and urban form, occupation and income as well as household car ownership. We conclude that, for this population, who are mainly part of low-income households, the emissions added by the use of e-bikes (in the case of replacement of non-motorized modes) are outweighed by the strong single occupancy vehicle (SOV) travel replacement. As a whole, our findings suggest a considerable potential for energy savings and emissions reductions from personal e-bike ownership.

ADVANCED PROPULSION SYSTEMS↗

An Open-Source Framework for Characterizing Urban Energy Models: Integrating Top-Down and Bottom-Up Methods to Predict Residential Buildings Characteristics: Preprint

Bottom-up urban energy models are crucial for understanding current energy use patterns and informing design strategies. However, accurately characterizing these models to represent different communities remains a challenge due to the extensive data needed for simulating existing energy use behavior. This data includes information related to human activities and building characteristics, all of which correlate with socioeconomic factors. To overcome this challenge, we developed an automated framework that utilizes both top-down and bottom-up data, to predict unknown building and occupant characteristics that are needed for more accurate and equitable modeling and analytics. Our framework, integrated into the URBANopt district energy modeling platform, uses statistical data models from ResStock. URBANopt models co-located buildings and neighborhoods. At this scale there are data gaps in building characteristic data, such as materials, insulation, occupancy, income, and energy usage of the buildings. To address this data gap, we use ResStock data, representative at the census tract scale, and develop machine-learning and deeplearning techniques to disaggregate it to individual buildings. By mapping unique occupant, building and economic properties to URBANopt energy models, we gain detailed insights into the variability of building energy use across different neighborhoods. This insight helps deploy technologies for co-located buildings and supports targeted upgrades for communities with unique economic and demographic characteristics, ensuring energy equity. Accurate characterization of energy models allows us to develop equitable strategies tailored to diverse neighborhoods, whether underserved or affluent. Our automated framework streamlines energy modeling and provides a reliable tool for building energy characterization.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Impact analysis of personalized thermostat demand response

Demand response (DR) aims to curtail peak electric load to avoid running inefficient power plants, reduce costly transmission capacity increases, and improve grid reliability. One method of DR for residential settings involves the utility or third part remotely adjusting thermostat temperatures. Cooling setpoints may be increased 2°F – 6°F for hours, irrespective of occupant comfort. To maintain their comfort, occupants override these setpoint changes impacting the reliability of DR services provided to the grid. This paper presents a preliminary impact analysis of replacing the current DR approach of uniform thermostat setbacks for an entire population with personalized and context aware DR based on a dynamic model of occupant thermal comfort behavior. Over 151k interactions with ecobee thermostats are analyzed to predict the impact of such personalized DR on overrides, energy curtailment magnitude, and reliability.

Kane, Michael↗

Individual Data Sparsity in Smart Thermostat Big Data: Impacts on Modeling Thermostat Use Behavior Dynamics

This study explores the impacts of the sparsity of individual thermostat interaction data on modeling thermostat use behavior dynamics using a dataset of over 100,000 smart thermostats. In developing a data-driven model of Thermal Frustration Theory (TFT), we investigate the challenges and trade-offs in clustering occupant data to enhance predictive accuracy. Our findings reveal that a single, aggregated model fails to capture the diversity of occupant behaviors, resulting in extremely poor prediction performance. Conversely, excessive clustering exacerbates data sparsity, undermining model reliability. By identifying an optimal clustering strategy, we achieve a balance that significantly improves the prediction of manual setpoint changes during demand response (DR) events, enhancing energy management and occupant comfort

Fannon, David↗

Evaluating Thermostats’ Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Thermostats play a crucial role in energy consumption, user control, and occupant comfort by serving as the interface between the heating, ventilation, and air conditioning (HVAC) system and the building's occupants. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on or off. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different thermostats, tested with a residential heat pump, aiming to identify variations in their deadband settings and implications for energy usage and management. The experimental study was conducted using a HVAC hardware-in-the-loop (HIL) system that allows thermostats to be connected with physical HVAC equipment, driven by conditions in a simulated residential building. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats cycle differently based on their deadband settings. The findings offer valuable insights into how thermostat deadband affects comfort and energy use, as well as the cycling frequency of a heat pump.

Ramaraj, Sugirdhalakshmi [National Renewable Energ↗

Mortality of older construction and craft workers employed at Department of Energy (DOE) nuclear sites: Follow‐up through 2021

Background To determine if construction and trades workers formerly employed at US Department of Energy (DOE) nuclear weapons sites are at significant risk for occupational diseases, we studied the mortality experience of participants in the Building Trades National Medical Screening Program (BTMed). Methods The cohort included 26,922 participants enrolled between 1998 and 2021 and 8367 deaths. Standardized mortality ratios were calculated based on US death rates. Cox models compared construction workers (n = 22,747; 7487 deaths) to two nonconstruction subpopulations: administrative, scientific and security workers (n = 1894; 330 deaths), and all other nonconstruction workers (n = 2218; 550 deaths). Results Mortality was elevated for all causes, all cancers, cancers of the trachea, bronchus, lung, kidneys, and lymphatic and hematopoietic system, mesothelioma, chronic obstructive pulmonary disease (COPD), asbestosis, transportation injuries, and other injuries, particularly accidental poisonings. There were 167 deaths from coronavirus disease 2019 (COVID-19), which was lower than expected using US death rates. Overall cause-specific mortality was significantly higher among construction workers than for internal comparison groups. Conclusions Construction workers employed at DOE sites have a significantly increased risk for occupational illnesses. Apart from COVID-19 deaths, this update: (1) found that mortality among construction workers is significantly elevated compared to the US population and significantly higher than in the internal comparison populations, and (2) confirmed excess risk for these workers for first employment after 1990. Cancer mortality risks are similar to the cancers identified for DOE compensation from radiation exposures. In conclusion, the high lung cancer risk supports the value of early lung cancer detection. Continued medical surveillance is important.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Respirator Cartridge Performance on Mixed Vapors from Hanford Tank Headspaces and Exhausters - 20427

Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A case-control study of airways obstruction among construction workers: Airways Obstruction Among Construction Workers

Background: While smoking is the major cause of chronic obstructive pulmonary disease (COPD), occupational exposures to vapors, gases, dusts, and fumes (VGDF) increase COPD risk. This case-control study estimated the risk of COPD attributable to occupational exposures among construction workers. Methods: The study population included 834 cases and 1243 controls participating in a national medical screening program for older construction workers between 1997 and 2013. Qualitative exposure indices were developed based on lifetime work and exposure histories. Results: Approximately 18% (95%CI=2–24%) of COPD risk can be attributed to construction-related exposures, which are additive to the risk contributed by smoking. A measure of all VGDF exposures combined was a strong predictor of COPD risk. Conclusions: Construction workers are at increased risk of COPD as a result of broad and complex effects of many exposures acting independently or interactively. Control methods should be implemented to prevent worker exposures, and smoking cessation should be promoted

60 APPLIED LIFE SCIENCES↗

Mortality of older construction and craft workers employed at department of energy nuclear sites: Follow‐up through 2016

Abstract Background To determine if construction and trades workers employed at U.S. Department of Energy (DOE) nuclear sites facilities are at significant risk for diseases associated with occupational exposures, we compared the mortality experience of participants in the Building Trades National Medical Screening Program (BTMed) to that of the US population. Methods The cohort includes 24,086 BTMed participants enrolled between 1998 and 2016 and 5203 deaths. Cause‐specific standardized mortality ratios were calculated based on US death rates. Results Mortality was elevated for all causes, all cancers, cancers of the trachea, bronchus, and lung and lymphatic and hematopoietic system, mesothelioma, chronic obstructive pulmonary disease, asbestosis, transportation injuries, and other injuries, particularly those caused by accidental poisoning, suggesting a possible effect of the opioid epidemic. Conclusions Apart from other injuries, mortality patterns were very similar to those reported in the past in this population. Construction workers employed at DOE sites have a significantly increased risk for occupational illnesses. Risks are associated with employment during all time periods covered including possibly after 1990. The cancer risks closely match the cancers identified for DOE compensation from radiation exposures. The high risk of lung cancer supports the value of early lung cancer detection. Continued medical surveillance is important.

Ringen, Knut↗

Problems in Determination of Skeletal Lead Burden in Archaeological Samples: An Example From the First African Baptist Church Population

ABSTRACT Human bone lead content has been demonstrated to be related to socioeconomic status, occupation and other social and environmental correlates. Skeletal tissue samples from 135 individuals from an early nineteenth century Philadelphia cemetery (First African Baptist Church) were studied by electrothermal atomic absorption spectrometry and x-ray fluorescence for lead content. High bone lead levels led to investigation of possible diagenetic effects. These were investigated by several different approaches including distribution of lead within bone by x-ray fluorescence, histological preservation, soil lead concentration and acidity as well as location and depth of burial. Bone lead levels were very high in children, exceeding those of the adult population that were buried in the cemetery, and also those of present day adults. The antemortem age-related increase in bone lead, reported in other studies, was not evidenced in this population. Lead was even deposited in areas of taphonomic bone destruction. Synchrotron x-ray fluorescence studies revealed no consistent pattern of lead microdistribution within the bone. Our conclusions are that postmortem diagenesis of lead ion has penetrated these archaeological bones to a degree that makes their original bone lead content irretrievable by any known method. Increased bone porosity is most likely responsible for the very high levels of lead found in bones of newborns and children.

43 PARTICLE ACCELERATORS↗

Cytogenetic monitoring of coal workers and patients with coal workers' pneumoconiosis in Turkey

Occupational exposure to coal dust causes coal workers' pneumoconiosis (CWP), which is a chronic inflammatory and fibrotic lung disease. Recently, chronic inflammation has been accepted as a crucial factor in the pathogenesis of neoplasia. The chronic inflammation provides dynamic setting for oxidative stress and formation of free radicals. Interaction of reactive oxygen species (ROS) with DNA augments the likelihood of DNA structural and transcriptional errors. The purpose of this study was to investigate the genotoxic risk in pneumoconiotic patients and in those with occupational exposure to coal dust. Therefore, sister chromatid exchange (SCE) and micronucleus (MN) tests were performed in Turkish CWP patients, coal workers, and an unexposed control group. Both SCE and MN frequencies in CWP patients were found significantly higher than in coal worker and unexposed groups. There were no differences between SCE and MN frequencies of coal worker and unexposed groups. On the other hand, no correlation between SCE frequency, duration of exposure, and age was observed in all three groups. There was also no effect of smoking on the frequencies of SCE and MN in the groups. Based on these results, it might be suggested that development of CWP leads to a significant induction of cytogenetic damage in peripheral lymphocytes of CWP patients. This is the first report on CWP patients with elevated cytogenetic endpoints. Further, a larger follow-up study is warranted.

01 COAL, LIGNITE, AND PEAT↗

Staff Radiation Doses in a Real-Time Display Inside the Angiography Room

MethodsThe evaluation of a new occupational Dose Aware System (DAS) showing staff radiation doses in real time has been carried out in several angiography rooms in our hospital. The system uses electronic solid-state detectors with high-capacity memory storage. Every second, it archives the dose and dose rate measured and is wirelessly linked to a base-station screen mounted close to the diagnostic monitors. An easy transfer of the values to a data sheet permits further analysis of the scatter dose profile measured during the procedure, compares it with patient doses, and seeks to find the most effective actions to reduce operator exposure to radiation.ResultsThe cumulative occupational doses measured per procedure (shoulder-over lead apron) ranged from 0.6 to 350 {mu}Sv when the ceiling-suspended screen was used, and DSA (Digital Subtraction Acquisition) runs were acquired while the personnel left the angiography room. When the suspended screen was not used and radiologists remained inside the angiography room during DSA acquisitions, the dose rates registered at the operator's position reached up to 1-5 mSv/h during fluoroscopy and 12-235 mSv/h during DSA acquisitions. In such case, the cumulative scatter dose could be more than 3 mSv per procedure.ConclusionReal-time display of doses to staff members warns interventionists whenever the scatter dose rates are too high or the radiation protection tools are not being properly used, providing an opportunity to improve personal protection accordingly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring

PurposeRadiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions.Materials and MethodsMedical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1–5th months: Staff did not receive feedback (n = 701) and (2) 6–8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose.ResultsPersonalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04–0.50) µSv/Gy cm{sup 2} versus (phase 2) 0.08 (0.02–0.24) µSv/Gy cm{sup 2}, p = 0.002].ConclusionPersonalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

61 RADIATION PROTECTION AND DOSIMETRY↗