Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

System Engineers and Decisions: It?s All about Knowledge

In order to guarantee that a system meets adequate levels of reliability and availability, system performances are continuously monitored and analyzed thanks to the technological advancements driving the Industry 4.0 revolution. An Industry 4.0 approach is typically based on advanced statistical, big data mining, machine learning, and internet-of-things methods designed to detect anomalies in the behavior of system, detect the most likely failure modes, and provide indications to system engineers on when maintenance activities should be performed before system performance are deemed unacceptable (which can be generated by diagnostic and prognostic methods). However, these analyses, which are designed to automatize and increase the efficacy of the system maintenance program, require large amount of data which can come in various forms: numeric, textual, images, sounds etc. Such data constitutes the historic knowledge benchmark to track system performances and support system engineer decisions. Here we claim that data is not sufficient to support this kind of analyses when applied to systems characterized by complex architectures and behaviors. Robust system engineer decisions require the ability to understand the system operational context that lies behind the observed data elements. In this respect, system models are in fact necessary to “put data in context” and capture relationships between data elements. Industry 4.0 methods require in fact contextual knowledge as a basis upon which hypotheses can be generated and assumptions tested. In our view, for complex systems, model-based system engineering (MBSE) models can afford this contextual knowledge, as they are typically used to describe systems architecture and dynamic behaviors. System knowledge is here intended as the blending of collected data and system architecture which takes the form of a “knowledge graph”. A knowledge graph is a database which consists of a large set of nodes (in our case an entity can be either a data or an MBSE element) which are linked to each other. The types of nodes and links follow a pre-defined topology, sometimes also refers as an ontology, that is designed to fit the actual decisions that needs to be performed. We show here how a knowledge graph can be defined to support system engineer maintenance decisions and how the same graph can be built based on system MBSE models and pre-processed data from numeric (through anomaly detections and diagnostic methods) and textual elements (through technical language processing TLP).

97 - MATHEMATICS AND COMPUTING↗

Feeder Voltage Regulation with High-Penetration PV Using Advanced Inverters and a Distribution Management System: A Duke Energy Case Study

Duke Energy, Alstom Grid, and the National Renewable Energy Laboratory teamed up to better understand the impacts of solar photovoltaics (PV) on distribution system operations. The core goal of the project is to compare the operational - specifically, voltage regulation - impacts of three classes of PV inverter operations: 1.) Active power only (Baseline); 2.) Local inverter control (e.g., PF...not equal...1, Q(V), etc.); and 3.) Integrated volt-VAR control (centralized through the distribution management system). These comparisons were made using multiple approaches, each of which represents an important research-and-development effort on its own: a) Quasi-steady-state time-series modeling for approximately 1 year of operations using the Alstom eTerra (DOTS) system as a simulation engine, augmented by Python scripting for scenario and time-series control and using external models for an advanced inverter; b) Power-hardware-in-the-loop (PHIL) testing of a 500-kVA-class advanced inverter and traditional voltage regulating equipment. This PHIL testing used cosimulation to link full-scale feeder simulation using DOTS in real time to hardware testing; c) Advanced visualization to provide improved insights into time-series results and other PV operational impacts; and d) Cost-benefit analysis to compare the financial and business-model impacts of each integration approach.

14 SOLAR ENERGY↗

Integrated Dispatching and Charging Management of an Autonomous Electric Vehicle Ride-Hailing Fleet

Electrification and autonomous driving are two important trends in transportation systems. The convergence of these two technologies will introduce opportunities to improve transportation systems' operation and energy efficiency. One potential application is the commercial ride-hailing fleet with autonomous electric vehicles (AEVs). In order to harvest promising benefits from introducing AEVs into ride-hailing fleets, some unavoidable challenges will need to be resolved to ensure the fleets operates functionally and efficiently. This paper discusses the challenges of dispatching AEVs and their interactions with charging infrastructure. An integrated decision making framework for dispatching and charging has been designed using a system optimization approach to study the AEVs' management within the period when they drop off passengers and pick up the next passengers. Its potential fleet-wide benefits have been illustrated by comparing operations under a heuristic approach. A simulation platform has been designed to test different decision making strategies for the ride-hailing AEV fleets operational performance. Using this platform, detailed case studies have been performed with different fleet sizes, dispatching strategies, and charging infrastructure network settings. Comprehensive analyses from various aspects have been conducted to understand the AEVs' fleet operation performance, (e.g., zero occupancy vehicle miles traveled, successfully served ratio of ride-hailing requests, fleet vehicle charging downtime, and charging infrastructure utilization). Results have provided a deep understandings on operation's dynamics under various fleet system configurations and also have demonstrated advantages of the optimization-based approach for the AEV fleet management. Studies in this paper inform better designs on the future of sophisticated management strategies and charging infrastructure to support ride-hailing AEV fleet operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Processing Unit Services Module

The Data Processing Services Module (DPUSM) provides the ability to perform pluggable compression, erasure coding, checksuming and other important file system operations within the Linux kernel. The pluggable provider interface allows for the use of hardware acceleration of those services. In-kernel file systems are then able to use these functions to use these accelerators to perform operations that are normally run on the processor, resulting in improved file system performance. Third parties will register "providers" with the DPUSM to communicate with their respective accelerators. Providers will implement functions with DPUSM API signatures so that the DPUSM can translate the data inputted by users of the DPUSM into data that providers recognize.

Lee, Jason↗

Bipolar Membrane Electrodialyzers as Flexible Demand Response Resources: Co-Optimization of Cost Savings and Product Formation

Bipolar membrane electro dialyzers (BPMED) are widely used for chemical production and processing, including in the emerging ocean alkalinity enhancement (OAE) industry. In this paper, we explore the potential of BPMED devices as flexible electrochemical loads within power system operations. Using a multi-objective optimization framework, we evaluate BPMED operation across 24-hour and monthly horizons to examine how dispatch strategies respond to electricity price and grid conditions. Simulation results show that altering the relative weights of the choices in the objective function strongly shape the operating patterns, with cost-focused strategies that suppress the operation during peak prices. Furthermore, we propose alternative formulations that optimize operations to achieve both cost savings and alignment with periods of lower grid-side carbon intensity (CI), as low grid-side CI is key to maximize OAE efficiency. Additionally, a detailed sensitivity analysis highlights the importance of device properties, where low area-specific resistance (ASR) of membrane and high current efficiency (CE) are observed to jointly unlock cost-effective operation. However, even modest shunt efficiency losses are observed to erode performance and decrease system value. Importantly, the analysis demonstrates that BPMED can serve as a controllable and flexible demand response resource, shifting load to support multiple grid-side objectives, including (but not limited to) renewable integration, alleviate peak demand, and provide co-benefits for system reliability. These findings underscore BPMED’s dual role as a process technology and a grid-supporting asset, pointing to promising pathways for operational optimization of multiple objectives.

Bhattacharya, Saptarshi (ORCID:0000000308902060)↗

Life-Cycle Analysis of Potentially Longer Life Expectancy CdTe PV Modules

Research on PV module longevity shows that with lower degradation rates and better encapsulation, PV modules can significantly outlast their current life expectancy of 25-30 years. The focus of this study is on alternative CdTe PV module back-contact and encapsulation materials that show the potential of increasing module operation lives from 30 to 40 and 50 years. Life-cycle-analyis shows that some alternative materials may slightly increase cradle-to-gate environmental impacts per m2 of module, but increased operational life more than counterbalances such impacts. The life-cycle carbn footprint of systems operating under average US insolation conditions of 1800 kWh/m2/yr is reduced from 10 gCO2eq/kWh to 6 gCO2eq/kWh when the operation life increases from 30 to 50 yrs. Similar reductions are noted for all life-cycle impact indicators, whereas the EROI of the considered system increases from 67 to 177 as life increases from 30 to 50 yrs.

14 SOLAR ENERGY↗

Resilient Grid Operational Strategies

Extreme weather-related disturbances, such as hurricanes, are a leading cause of grid outages historically. Although physical asset hardening is perhaps the most common way to mitigate the impacts of severe weather, operational strategies may be deployed to limit the extent of societal and economic losses associated with weather-related physical damage.1 The purpose of this study is to examine bulk power-system operational strategies that can be deployed to mitigate the impact of severe weather disruptions caused by hurricanes, thereby increasing grid resilience to maintain continuity of critical infrastructure during extreme weather. To estimate the impacts of resilient grid operational strategies, Los Alamos National Laboratory (LANL) developed a framework for hurricane probabilistic risk analysis (PRA). The probabilistic nature of this framework allows us to estimate the probability distribution of likely impacts, as opposed to the worst-case impacts. The project scope does not include strategies that are not operations related, such as transmission system hardening (e.g., undergrounding, transmission tower reinforcement and substation flood protection) and solutions in the distribution network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, implementation and migration of security systems as an extreme project.

Decision Trees, algorithms, software code, risk management, reports, plans, drawings, change control, presentations, and analysis - all useful tools and efforts but time consuming, resource intensive, and potentially costly for projects that have absolute schedule and budget constraints. What are necessary and prudent efforts when a customer calls with a major security problem that needs to be fixed with a proven, off-the-approval-list, multi-layered integrated system with high visibility and limited funding and expires at the end of the Fiscal Year? Whether driven by budget cycles, safety, or by management decree, many such projects begin with generic scopes and funding allocated based on a rapid management 'guestimate.' Then a Project Manager (PM) is assigned a project with a predefined and potentially limited scope, compressed schedule, and potentially insufficient funding. The PM is tasked to rapidly and cost effectively coordinate a requirements-based design, implementation, test, and turnover of a fully operational system to the customer, all while the customer is operating and maintaining an existing security system. Many project management manuals call this an impossible project that should not be attempted. However, security is serious business and the reality is that rapid deployment of proven systems via an 'Extreme Project' is sometimes necessary. Extreme Projects can be wildly successful but require a dedicated team of security professionals lead by an experienced project manager using a highly-tailored and agile project management process with management support at all levels, all combined with significant interface with the customer. This paper does not advocate such projects or condone eliminating the valuable analysis and project management techniques. Indeed, having worked on a well-planned project provides the basis for experienced team members to complete Extreme Projects. This paper does, however, provide insight into what it takes for projects to be successfully implemented and accepted when completed under extreme conditions.

99 GENERAL AND MISCELLANEOUS↗

Design implementation and migration of security systems as an extreme project.

Decision Trees, algorithms, software code, risk management, reports, plans, drawings, change control, presentations, and analysis - all useful tools and efforts but time consuming, resource intensive, and potentially costly for projects that have absolute schedule and budget constraints. What are necessary and prudent efforts when a customer calls with a major security problem that needs to be fixed with a proven, off-the-approval-list, multi-layered integrated system with high visibility and limited funding and expires at the end of the Fiscal Year? Whether driven by budget cycles, safety, or by management decree, many such projects begin with generic scopes and funding allocated based on a rapid management 'guestimate.' Then a Project Manager (PM) is assigned a project with a predefined and potentially limited scope, compressed schedule, and potentially insufficient funding. The PM is tasked to rapidly and cost effectively coordinate a requirements-based design, implementation, test, and turnover of a fully operational system to the customer, all while the customer is operating and maintaining an existing security system. Many project management manuals call this an impossible project that should not be attempted. However, security is serious business and the reality is that rapid deployment of proven systems via an 'Extreme Project' is sometimes necessary. Extreme Projects can be wildly successful but require a dedicated team of security professionals lead by an experienced project manager using a highly-tailored and agile project management process with management support at all levels, all combined with significant interface with the customer. This paper does not advocate such projects or condone eliminating the valuable analysis and project management techniques. Indeed, having worked on a well-planned project provides the basis for experienced team members to complete Extreme Projects. This paper does, however, provide insight into what it takes for projects to be successfully implemented and accepted when completed under extreme conditions.

99 GENERAL AND MISCELLANEOUS↗

Resilient Control Systems Practical Metrics Basis for Defining Mission Impact

"Resilience” describes how systems operate at an acceptable level of normalcy despite disturbances or threats. In this paper we first consider the cognitive, cyber-physical interdependencies inherent in critical infrastructure systems and how resilience differs from reliability to mitigate these risks. Terminology and metrics basis are provided to integrate the cognitive, cyber-physical aspects that should be considered when defining solutions for resilience. A practical approach is taken to roll this metrics basis up to system integrity and business case metrics that establish “proper operation” and “impact.” A notional chemical processing plant is the use case for demonstrating how the system integrity metrics can be applied to establish performance, and

42 ENGINEERING↗

Overgeneration from Solar Energy in California. A Field Guide to the Duck Chart

In 2013, the California Independent System Operator published the 'duck chart,' which shows a significant drop in mid-day net load on a spring day as solar photovoltaics (PV) are added to the system. The chart raises concerns that the conventional power system will be unable to accommodate the ramp rate and range needed to fully utilize solar energy, particularly on days characterized by the duck shape. This could result in 'overgeneration' and curtailed renewable energy, increasing its costs and reducing its environmental benefits. This paper explores the duck chart in detail, examining how much PV might need to be curtailed if additional grid flexibility measures are not taken, and how curtailment rates can be decreased by changing grid operational practices. It finds that under "business-as-usual"" types of assumptions and corresponding levels of grid flexibility in California, solar penetrations as low as 20% of annual energy could lead to marginal curtailment rates that exceed 30%. However, by allowing (or requiring) distributed PV and storage (including new installations that are part of the California storage mandate) to provide grid services, system flexibility could be greatly enhanced. Doing so could significantly reduce curtailment and allow much greater penetration of variable generation resources. Overall, the work described in this paper points to the need to fully integrate distributed resources into grid system planning and operations to allow maximum use of the solar resource.

14 SOLAR ENERGY↗

Overgeneration from Solar Energy in California - A Field Guide to the Duck Chart

In 2013, the California Independent System Operator published the "duck chart,"" which shows a significant drop in mid-day net load on a spring day as solar photovoltaics (PV) are added to the system. The chart raises concerns that the conventional power system will be unable to accommodate the ramp rate and range needed to fully utilize solar energy, particularly on days characterized by the duck shape. This could result in "overgeneration"" and curtailed renewable energy, increasing its costs and reducing its environmental benefits. This paper explores the duck chart in detail, examining how much PV might need to be curtailed if additional grid flexibility measures are not taken, and how curtailment rates can be decreased by changing grid operational practices. It finds that under business-as-usual types of assumptions and corresponding levels of grid flexibility in California, solar penetrations as low as 20 percent of annual energy could lead to marginal curtailment rates that exceed 30 percent. However, by allowing (or requiring) distributed PV and storage (including new installations that are part of the California storage mandate) to provide grid services, system flexibility could be greatly enhanced. Doing so could significantly reduce curtailment and allow much greater penetration of variable generation resources in achieving a 50 percent renewable portfolio standard. Overall, the work described in this paper points to the need to fully integrate distributed resources into grid system planning and operations to allow maximum use of the solar resource.

14 SOLAR ENERGY↗

Microcontroller-based aerosol jet printer control software

This software is used with a microcontroller to control an aerosol jet printing system. It was written for a 32-bit ARM microcontroller, providing greater processing speed and complexity relative to more conventional low-cost printer controllers. The microcontroller software was written using a real-time operating system (FreeRTOS), which simplifies parallel operation of multiple functions and further customization. It supports simultaneous motion planning, pulse generation for stepper motors, reading encoder feedback, communicating with multiple mass flow controllers, controlling solid state relays, handling a software-based emergency stop, and sending data to the client PC. The program is written in C and communicates with the client PC via USB connection. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-0436 O

Secor, EthanBenjamin↗

Summary of a Workshop on Integrating Energy Equity into Power System Planning and Operation

On November 29 and 30, 2023, the Energy Systems Integration Group convened a one-and-a-half-day workshop in Arlington, Virginia, to improve knowledge and practices for integrating energy equity considerations into power system planning and operation. Workshop participants were invited to discuss approaches for integrating energy equity aspects into models and tools and to explore possible pathways for enhanced technical practices. Participants included utility planning and modeling practitioners, social science and energy justice academics, representatives from energy and environmental justice nongovernmental organizations, non-profits, consumer advocates, and representatives from the U.S. Department of Energy, national labs, and other government agencies. This report summarizes the discussion points and outcomes of the workshop, which prioritized the technical aspects of incorporating the challenges and solutions identified by electricity-futures stakeholders and communities. These technical activities include the fundamental grid structure and hardware, detailed modeling approaches that benchmark energy system performance and justify future investments, and engineering designs and limitations for potential solutions to meet energy equity goals in communities.

energy equity↗

Systems Analysis Programs for Hands-On Integrated Reliability Evaluations (SAPHIRE) Technical Reference

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer (PC) running the Microsoft Windows? operating system. Herein information is provided on the principles used in the construction and operation of Version 6.0 and 7.0 of the SAPHIRE system. This report summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms used to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that apply for various assumptions concerning reparability and mission time. It defines the measures of basic event importance that SAPHIRE can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by this program to generate random basic event probabilities from various distributions. Also covered are enhance capabilities such as seismic analysis, cut set "recovery," end state manipulation, and use of "compound events."

99 GENERAL AND MISCELLANEOUS↗

Failure diagnosis and trend‐based performance losses routines for the detection and classification of incidents in large‐scale photovoltaic systems

Abstract Fault detection and classification in photovoltaic (PV) systems through real‐time monitoring is a fundamental task that ensures quality of operation and significantly improves the performance and reliability of operating systems. Different statistical and comparative approaches have already been proposed in the literature for fault detection; however, accurate classification of fault and loss incidents based on PV performance time series remains a key challenge. Failure diagnosis and trend‐based performance loss routines were developed in this work for detecting PV underperformance and accurately identifying the different fault types and loss mechanisms. The proposed routines focus mainly on the differentiation of failures (e.g., inverter faults) from irreversible (e.g., degradation) and reversible (e.g., snow and soiling) performance loss factors based on statistical analysis. The proposed routines were benchmarked using historical inverter data obtained from a 1.8 MWp PV power plant. The results demonstrated the effectiveness of the routines for detecting failures and loss mechanisms and the capability of the pipeline for distinguishing underperformance issues using anomaly detection and change‐point (CP) models. Finally, a CP model was used to extract significant changes in time series data, to detect soiling and cleaning events and to estimate both the performance loss and degradation rates of fielded PV systems.

14 SOLAR ENERGY↗

Adjustable and distributionally robust chance-constrained economic dispatch considering wind power uncertainty

This paper proposes an adjustable and distributionally robust chance-constrained (ADRCC) optimal power flow (OPF) model for economic dispatch considering wind power forecasting uncertainty. The proposed ADRCC-OPF model is distributionally robust because the uncertainties of the wind power forecasting are represented only by their first- and second-order moments instead of a specific distribution assumption. The proposed model is adjustable because it is formulated as a second-order cone programming (SOCP) model with an adjustable coefficient. This coefficient can control the robustness of the chance constraints, which may be set up for the Gaussian distribution, symmetrically distributional robustness, or distributionally robust cases considering wind forecasting uncertainty. The conservativeness of the ADRCC-OPF model is analyzed and compared with the actual distribution data of wind forecasting error. The system operators can choose an appropriate adjustable coefficient to tradeoff between the economics and system security.

17 WIND ENERGY↗