Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings

An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the ‘direct-DC house’ with respect to today’s typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly influenced by climate. While direct-DC for residential applications will most likely arise as a spin-off of developments in the commercial sector—because of lower barriers to market entry and larger energy benefits resulting from the higher coincidence between load and insolation—this paper demonstrates that there are substantial benefits in the residential sector as well. Among residential applications, space cooling derives the largest energy savings from being delivered by a direct-DC system. It is the largest load for the average residence on a national basis and is particularly so in high-load regions. It is also the load with highest solar coincidence.

14 SOLAR ENERGY↗

Field evaluation of performance of HVAC optimization system in commercial buildings

Smart new building technologies that offer continuous dynamic optimization of Heating, Ventilation, and Air Conditioning (HVAC) control hold promise to advance building operations for efficiency and grid response. These technologies use data from the control system to determine the analytically optimal setpoints, and then write back the optimal setpoints into the control system to minimize system energy consumption or costs. There are limited studies documenting field validations of these technologies. This paper presents the results from a long-term field evaluation of a model-predictive HVAC optimization system that installed in four commercial buildings. Energy savings analysis was conducted based on pre/post submetered energy use. Across the cohort of evaluation sites, HVAC savings following the implementation of the optimization system were mixed, ranging from 0–9%. Analysis of site operational data showed that occupant comfort was neither positively nor negatively impacted. Key technology adoption considerations and recommendations are summarized in the paper. The technology performs best when HVAC systems are in good working condition, and can be exercised to achieve the full range of its optimized setpoints–however it may not provide extensive additional savings over cases where best practice sequences of operation and reset strategies are already comprehensively implemented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photoactivated p-Doping of Organic Interlayer Enables Efficient Perovskite/Silicon Tandem Solar Cells

Solution-processed organic semiconductor layers on rough surfaces tend to vary widely in thickness, significantly hindering charge extraction in relevant optoelectronic devices. Herein, we report the photoactivated p-doping of hole-transporting material (HTM) to enhance hole extraction for (textured) perovskite/silicon tandem solar cells, making the device performance less sensitive to the variation of hole transport layer thickness. We used the ionic compound 4-isopropyl-4'-methyldiphenyliodonium tetrakis(penta-fluorophenyl-borate) (DPI-TPFB) as a p-type dopant in poly(triaryl amine) (PTAA), which we used as the HTM. We observed that light soaking DPI-TPFB-doped PTAA shows approximately 22 times higher conductivity compared with an undoped PTAA film, which translated into an improved fill factor (FF) for tandem solar cells. Our tandem solar cells achieved an ~80% FF and 27.8% efficiency and operated at their maximum power point for 200 h without loss of performance, in addition to retaining ~83% of initial performance over a month of operation in an outdoor environment.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,S↗

Optimizing Energy Use in Pulp & Paper with DOE’s Energy Intensive Industries Resources

The U.S. pulp and paper industry is the third-largest energy consumer in manufacturing, accounting for roughly 10% of sector energy use. Improving energy efficiency reduces operating costs and strengthens competitiveness. To support this effort, the U.S. Department of Energy (DOE), through Oak Ridge National Laboratory (ORNL), launched the Energy Intensive Industries (EII) Initiative. A two-year pilot across 45 industrial sites identified more than 4 trillion Btu/year in potential energy savings. This presentation outlines plans for a follow-up technical assistance program tailored to pulp and paper mills. Available resources include a cost-savings scoping tool, implementation planning guidance, and technical support for applying advanced methods such as Pinch Analysis for integrated process-utilities optimization. The session introduces key Pinch Analysis principles and highlights case studies demonstrating measurable improvements. ORNL also seeks industry feedback on barriers to efficiency improvements, including technology gaps and resource needs. DOE’s broader objective is to accelerate productivity and economic competitiveness across U.S. energy-intensive industries.

Kamath, Dipti [ORNL] (ORCID:0000000278739994)↗

Evaluation of a deuterated detector for gamma-ray beam intensity measurements

Laser-Compton scattering sources of quasi-monochromatic γ-ray beams have been in operation for over 30 years, with new facilities being under construction or proposed. To sustain a high-quality experimental physics program, continuous monitoring of these beams is essential by measuring the spectral, temporal, and spatial characteristics. In this work, we introduce a new method for determining the γ-ray beam intensity by using photodisintegration of deuterons in an active target detector approach. Measurements were performed using deuterated liquid scintillator detectors at several incident gamma energies between 4 and 13 MeV at the High Intensity γ-ray Source, Durham, USA. The results demonstrate that an instrument based on a deuterated active detector can be used to monitor the intensity of the γ-ray beam with high efficiency and operational simplicity.

Compton scattering↗

A Multi-State Model for Catalyzing the National Home Energy Retrofit Market (Final Technical Report)

In the fall of 2010, the Alabama Department of Economic and Community Affairs (ADECA) launched the Multi-State Model for Catalyzing the National Home Energy Retrofit Market Project (Multi-State Project). This residential energy efficiency pilot program was a collaborative effort among the states of Alabama, Massachusetts, Virginia, and Washington, and was funded by competitive State Energy Program (SEP) awards through the U.S. Department of Energy (DOE). The objective of this project was to catalyze the home energy efficiency retrofit market in select areas within the state of Alabama. To achieve this goal, the project addressed a variety of marketplace elements that did not exist, or were underdeveloped, at the outset of the effort. These included establishing minimum standards and credentials for marketplace suppliers, educating and engaging homeowners on the benefits of energy efficiency and addressing real or perceived financial barriers to investments in whole-home energy efficiency, among others. The anticipated effect of the activities would be increased market demand for retrofits, improved audit to retrofit conversion rates and growth in overall community understanding of energy efficiency. The four-state collaborative was created with the intent of accelerating market transformation by allowing each state to learn from their peers, each of whom possessed different starting points, resources, and strategies for achieving the overall objective. The four partner states engaged the National Association of State Energy Officials (NASEO) to oversee a project steering committee and to manage the project evaluation for all four states. The steering committee, comprised of key program partners, met on a regular basis to provide overall project coordination, guidance, and progress assessment. While there were variances in program design among the states, there were several common elements: use of the Energy Performance Score (EPS) platform; an audit and home energy rating tool; emphasis on community based coordination and partnerships; marketing and outreach to increase homeowner participation; training for market actors; access to financing options including rebates, incentives, and loan products; and an in depth process evaluation to support continual program improvement and analysis. In Alabama, Nexus Energy Center operated energy efficiency retrofit programs in Huntsville and Birmingham. In the Huntsville community the AlabamaWISE program was available in five Alabama counties: Cullman, Lawrence, Limestone, Madison, and Morgan. In Birmingham, the program was available to residents in Jefferson and Shelby Counties. In both communities, the program was similar in terms of program design but tailored marketing and partnerships to address the unique local conditions and population of each community. ADECA and the Southeast Energy Efficiency Alliance (SEEA) provided overall project management services and common resources to the local program administrator Nexus Energy Center, including contracted services for contractor training, quality assurance testing, data collection and reporting, and compliance. The fundamental components of the AlabamaWISE program included a vertical contractor-based business model; comprehensive energy assessments; third-party quality assurance; rebates for installation of energy saving measures; accessible, low-interest financing; targeted and inbound marketing; Energy Performance Score (EPS) tool to engage and educate homeowners; training for auditors, contractors, and real estate professionals; and online resources for education and program enrollment. Program participants were eligible to receive rebates or financing toward the assessments and upgrades to their home provided they reached at least 20 percent deemed or modeled energy savings. The design of each program focused on addressing several known barriers including: limited homeowner knowledge on the benefits of energy efficiency, lack of financing options, lack of community support for energy efficiency programs, and lack of trained market actors including contractors and real estate professionals. The programs were able to make progress on addressing all of these barriers and were most successful in offering financing options and training market actors. The most challenging barriers proved to be the act of building a market for energy efficiency where none previously existed, convincing homeowners of the value in investing in energy efficiency (and therefore completing retrofits), engaging electric and natural gas utilities to partner on delivery, and achieving the overall project target of 1,365 completed retrofits. The components that proved to be the most valuable to program success were engaged contractor networks that could promote and endorse the program, partnerships with local business and organizations, and the access to rebates, incentives and financing mechanisms. The programs were successful in building relationships with a variety of community participants including: local contractors, Associations of REALTORS, home builders associations, universities, utilities, local and state governments, and other non-profit organizations. Throughout this program, 933 building audits and 795 building retrofits were completed making homes in Alabama more comfortable, less expensive to operate, more valuable to the marketplace, and safer and healthier for families. Continuing on this momentum, Nexus Energy Center plans to continue operating and expanding operations in Alabama as a Home Performance with ENERGY STAR sponsor and will continue to provide energy services and education to communities in Alabama.

Grimes, Elizabeth M.↗

Better Buildings Workforce Accelerator – Technical Assistance Project: Northwest Energy Efficiency Council – A Replicable Analysis for Building Operator Certification Diversity, Equity, and Inclusion Objectives

The Northwest Energy Efficiency Council (NEEC) requested technical assistance through the U.S. Department of Energy (DOE) Better Buildings Workforce Accelerator (BBWA) program, with the objective of developing a replicable analytical approach to understanding Building Operator Certification (BOC) program participants and measure progress towards diversity, equity, and inclusion objectives. The technical assistance advances NEEC’s progress towards their goal of recruiting more diverse students to the BOC training and certification program. This report develops a replicable geospatial analysis of BOC program participants based on DEI indicators that can be applied at a national level, provides a step-by-step guide on repeating and updating the analysis, and presents recommendations for future data collection and analysis.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ON THE POLAR CAP CASCADE PAIR MULTIPLICITY OF YOUNG PULSARS

We study the efficiency of pair production in polar caps of young pulsars under a variety of conditions to estimate the maximum possible multiplicity of pair plasma in pulsar magnetospheres. We develop a semi-analytic model for calculation of cascade multiplicity which allows efficient exploration of the parameter space and corroborate it with direct numerical simulations. Pair creation processes are considered separately from particle acceleration in order to assess different factors affecting cascade efficiency, with acceleration of primary particles described by recent self-consistent non-stationary model of pair cascades. We argue that the most efficient cascades operate in the curvature radiation/synchrotron regime, the maximum multiplicity of pair plasma in pulsar magnetospheres is ∼few × 10{sup 5}. The multiplicity of pair plasma in magnetospheres of young energetic pulsars weakly depends on the strength of the magnetic field and the radius of curvature of magnetic field lines and has a stronger dependence on pulsar inclination angle. This result questions assumptions about very high pair plasma multiplicity in theories of pulsar wind nebulae.

79 ASTRONOMY AND ASTROPHYSICS↗

Chapter 7: Refrigerator Recycling Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures

Refrigerator recycling programs are designed to save energy by removing operable, albeit less efficient, refrigerators from service. By offering free pickup, providing incentives, and disseminating information about the operating cost of less efficient refrigerators, these programs are designed to encourage consumers to: - Limit the use of secondary refrigerators -Relinquish refrigerators previously used as primary units when they are replaced (rather than keeping the existing refrigerator as a secondary unit) -Prevent the continued use of less efficient refrigerators in another household through a direct transfer (giving it away or selling it) or indirect transfer (resale on the used appliance market). Commonly implemented by third-party contractors (who collect and decommission participating appliances), these programs generate energy savings through the retirement of inefficient appliances. The decommissioning process captures environmentally harmful refrigerants and foam, and enables recycling of the plastic, metal, and wiring components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategies for microgrid operation under real-world conditions

Microgrids are an increasingly relevant technology for integrating renewable energy sources into electricity systems. Based on a microgrid implementation in California, in this study we investigate microgrid operation under real-world conditions. These conditions have not yet been considered in combination and encompass energy charges, demand charges, export limits, as well as uncertainty about future electricity demand and generation in the microgrid. Under these conditions, we evaluate the performance of two frequently applied groups of strategies for microgrid operation. The first group is composed of proactive strategies that optimize decisions based on forecasts of future electricity generation and demand. The second group includes reactive strategies that make operational decisions based exclusively on the current state of the microgrid. We evaluate the performance of the strategies under varying operational parameters, forecast accuracies, and microgrid configurations—well beyond our Californian showcase. Our results confirm the expectation that proactive strategies outperform reactive ones in the majority of settings. Yet, reactive strategies can perform better under short control intervals or under moderate prediction errors of PV generation or demand. Furthermore, the interplay between real-world conditions and operational strategies reveals several additional insights for research on microgrid operation. First, we find that demand charges and export limits decisively affect microgrid performance. Second, the impact of forecast errors is highly non-linear and non-monotonous. Third, escalating negative interactions between forecast errors and demand charges make proactive strategies benefit from longer control intervals. This result is contrary to existing best practice, which promotes short control intervals to minimize the impact of uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physics and technology in the ion-cyclotron range of frequency on Tore Supra and TITAN test facility: implication for ITER

To support the design of an ITER ion-cyclotron range of frequency heating (ICRH) system and to mitigate risks of operation in ITER, CEA has initiated an ambitious Research & Development program accompanied by experiments on Tore Supra or test-bed facility together with a significant modelling effort. The paper summarizes the recent results in the following areas: Comprehensive characterization (experiments and modelling) of a new Faraday screen concept tested on the Tore Supra antenna. A new model is developed for calculating the ICRH sheath rectification at the antenna vicinity. The model is applied to calculate the local heat flux on Tore Supra and ITER ICRH antennas. Full-wave modelling of ITER ICRH heating and current drive scenarios with the EVE code. With 20 MW of power, a current of 400 kA could be driven on axis in the DT scenario. Comparison between DT and DT(3He) scenario is given for heating and current drive efficiencies. First operation of CW test-bed facility, TITAN, designed for ITER ICRH components testing and could host up to a quarter of an ITER antenna. R&D of high permittivity materials to improve load of test facilities to better simulate ITER plasma antenna loading conditions.

Litaudon, X↗

Advancing quantum simulations of the nuclear shell model with Gray-code–based resource-efficient protocols

Background: Some of the computational limitations in solving the nuclear many-body problem could be overcome by utilizing quantum computers. The nuclear shell-model calculations providing deeper insights into the properties of atomic nuclei are one such case with high demand for resources, as the size of the Hilbert space grows exponentially with the number of particles involved. Quantum algorithms are being developed to overcome these challenges and advance such calculations. Purpose: To develop quantum circuits for the nuclear shell-model, leveraging the capabilities of noisy intermediate-scale quantum (NISQ) devices. Here, we aim to minimize resource requirements (specifically in terms of qubits and gates) and strive to reduce the impact of noise by employing relevant mitigation techniques. Methods: We achieve noise resilience by designing an optimized Ansatz for the variational quantum eigensolver (VQE) based on Givens rotations and incorporating qubit-ADAPT-VQE in combination with variational quantum deflation (VQD) to compute ground and excited states, incorporating the zero-noise extrapolation mitigation technique. Furthermore, the qubit requirements are significantly reduced by mapping the basis states to qubits using Gray-code encoding and generalizing transformations of fermionic operators to efficiently represent many-body states. Results: By employing the resource-efficient protocols, we achieve the ground and excited state energy levels of 38 Ar and 6 Li with better accuracy. These energy levels are presented for noiseless simulations, noisy conditions, and after applying noise mitigation techniques. Results are compared for Jordan-Wigner and Gray-code encoding using VQE, qubit-ADAPT-VQE, and VQD. Conclusions: Our work highlights the potential of resource-efficient protocols to leverage the full potential of NISQ devices in scaling the nuclear shell model calculations, offering a pathway toward more complex quantum simulations in nuclear physics. This approach establishes a framework for studying other nuclear systems with improved quantum resource efficiency, marking a significant advancement in applying quantum computing to realistic nuclear physics applications.

Physics - Nuclear physics and radiation physics↗

Optimizing a low-energy electron diffraction spin-polarization analyzer for imaging of magnetic surface structures

A newly designed scanning electron microscope with polarization analysis (SEMPA or spin-SEM) for the acquisition of magnetic images is presented. Core component is the spin detector, based on the scattering of low-energy electrons at a W(100) surface in ultrahigh vacuum. The instrument has been optimized with respect to ease of handling and efficiency. The operation and performance of a general low-energy electron diffraction (LEED) detector for SEMPA have been modeled in order to find the optimum operating parameters and to predict the obtainable image asymmetry. Based on the energy dependence of the secondary electron polarization and intensity, the detector output is simulated. For our instrument with optimized performance we demonstrate experimentally 8.6% polarization asymmetry in the domain structure of an iron whisker. This corresponds to 17.2% image contrast, in excellent agreement with the predicted simulated value. A contrast to noise ratio of 27 is achieved at 5 ms acquisition time per pixel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Porting fragmentation methods to GPUs using an OpenMP API: Offloading the resolution-of-the-identity second-order Møller–Plesset perturbation method

Here, using an OpenMP Application Programming Interface, the resolution-of-the-identity second-order Møller–Plesset perturbation (RI-MP2) method has been off-loaded onto graphical processing units (GPUs), both as a standalone method in the GAMESS electronic structure program and as an electron correlation energy component in the effective fragment molecular orbital (EFMO) framework. First, a new scheme has been proposed to maximize data digestion on GPUs that subsequently linearizes data transfer from central processing units (CPUs) to GPUs. Second, the GAMESS Fortran code has been interfaced with GPU numerical libraries (e.g., NVIDIA cuBLAS and cuSOLVER) for efficient matrix operations (e.g., matrix multiplication, matrix decomposition, and matrix inversion). The standalone GPU RI-MP2 code shows an increasing speedup of up to 7.5× using one NVIDIA V100 GPU with one IBM 42-core P9 CPU for calculations on fullerenes of increasing size from 40 to 260 carbon atoms using the 6-31G(d)/cc-pVDZ-RI basis sets. A single Summit node with six V100s can compute the RI-MP2 correlation energy of a cluster of 175 water molecules using the correlation consistent basis sets cc-pVDZ/cc-pVDZ-RI containing 4375 atomic orbitals and 14 700 auxiliary basis functions in ~0.85 h. In the EFMO framework, the GPU RI-MP2 component shows near linear scaling for a large number of V100s when computing the energy of an 1800-atom mesoporous silica nanoparticle in a bath of 4000 water molecules. The parallel efficiencies of the GPU RI-MP2 component with 2304 and 4608 V100s are 98.0% and 96.1%, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Virtual engineering for the design and operation of advanced energy plants

The goals and objectives of this presentation are: (1) Develop and apply dynamic simulation to pulverized coal (PC) plants with post- and oxy-combustion CO{sub 2} capture systems - (a) Improve operational flexibility, controllability, and efficiency, (b) Optimize transient operations including disturbances, startup, shutdown, fuel switching, and load following, (c) Enhance malfunction, safety, and environmental analysis; (2) Provide dynamic simulator-based training for design, process, and control engineers, as well as plant operators; and (3) Learn-by-operating to accelerate CO{sub 2} capture technology scale-up, risk reduction, and deployment.

97 MATHEMATICS AND COMPUTING↗

Factors reducing the efficiency of ytterbium fibre lasers and amplifiers operating near 0.98 μm

We have studied the factors that reduce the efficiency of cladding-pumped ytterbium fibre lasers and amplifiers operating in the spectral range around a wavelength of 0.98 μm. It has been shown that the core of the active fibre being not single-mode leads to accelerated development of amplified spontaneous luminescence around λ = 1.03 μm, which reduces the highest possible amplifier efficiency. We have examined the effect of spontaneous luminescence propagating in the first reflective cladding. It has been shown theoretically that the pump-to-signal conversion efficiency is highest when the ratio of the core and cladding diameters in a multimode active fibre lies in the range 0.7 – 1. We have fabricated and characterised an optical fibre with a core-to-cladding diameter ratio of 0.76 (core and cladding diameters of 95 and 125 μm, respectively), which allowed a pump conversion efficiency of 66 % to be reached, a record level for cladding-pumped ytterbium fibre laser systems emitting near 0.98 μm. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Impact of LPG Composition on Performance, Emissions, and Combustion Characteristics of a Pre-mixed Spark-Ignited CFR Engine

Research on alternative fuels has made significant progress as demands for cleaner and more efficient engine operation intensifies. Liquefied petroleum gas (LPG) can offer a potential alternative fuel route in the Diesel fuel dominated heavy-duty transportation sector due to its low cost, high anti-knock limit relative to gasoline, and reduced emission levels. In this work, experimental investigations are performed to study the effects of LPG compositions on performance, emissions, and combustion behavior of a spark-ignited (SI) cooperative fuel research (CFR) engine under stoichiometric conditions. Four LPG blends (chemically pure propane, a representative US blend, HD-5, and a representative European blend) representing the present LPG market are chosen. The impact of fuel composition is studied under different compression ratios (CR), ranging from 7:1 to 10:1 with one-unit increments, and at constant engine speed, intake manifold air pressure (IMAP) and 50% burn crank angle (CA50). The results show that fuel composition has minimal effect on engine efficiency over the CR range 7:1 to 10:1. Engine-out emissions are substantially affected by fuel compositions with the representative European blend indicating higher unburned hydrocarbon (UHC) emissions, particularly at higher CR. The representative US blend emits the lowest brake specific CO (bsCO) averaged over the tested CR range. With the increase of CR, end-gas autoignition intensifies for all blends and the representative European blend demonstrates the highest knock intensity of all tested blends, due to the presence of the more reactive fuel component, n-butane.

Fosudo, Toluwalase↗