Search NASA⌕ Search

SEARCH · Search NASA

Results for “PENETRATION DEPTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Analysis of light scattering by two-dimensional inhomogeneities in paper using general radiative transfer theory

Lateral light scattering simulations of printed dots are analyzed using general radiative transfer theory. We investigated the appearance of a printed paper in relation to the medium parameters like thickness of the paper sample, its optical properties, and the asymmetry factor. It was found that the appearance of a print greatly depends on these factors making it either brighter or darker. A thicker substrate with higher single scattering albedo backed with an absorbing surface makes the dots brighter due to increased number of scattering events. Additionally, it is shown that the optical effects of print also depend on illuminating and viewing angles along with the depth of ink penetration. A larger single scattering angle implies less intensity and the dots appear much blurred due to the shadowing effect prominent when viewed from sides. A fully penetrated dot of the same extinction coefficient as a partial penetrated one is darker due to increased absorption. These results can be used in applications dealing with lateral light scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computational stochastic model of ions implantation

Implantation flux ions into crystal leads to phase transition /PT/ 1-st kind. Damaging lattice is associated with processes clustering vacancies and gaseous bubbles as well their brownian motion. System of stochastic differential equations /SDEs/ Ito for evolution stochastic dynamical variables corresponds to the superposition Wiener processes. The kinetic equations in partial derivatives /KE/, Kolmogorov-Feller and Einstein-Smolukhovskii, were formulated for nucleation into lattice of weakly soluble gases. According theory, coefficients of stochastic and kinetic equations uniquely related. Radiation stimulated phase transition are characterized by kinetic distribution functions /DFs/ of implanted clusters versus their sizes and depth of gas penetration into lattice. Macroscopic parameters of kinetics such as the porosity and stress calculated in thin layers metal/dielectric due to Xe{sup ++} irradiation are attracted as example. Predictions of porosity, important for validation accumulation stresses in surfaces, can be applied at restoring of objects the cultural heritage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric field dynamics in nitride structures containing quaternary alloy (Al, In, Ga)N

Molecular beam epitaxy growth and basic physical properties of quaternary AlInGaN layers, sufficiently thick for construction of electron blocking layers (EBL), embedded in ternary InGaN layers are presented. Transmission electron microscopy (TEM) measurement revealed good crystallographic structure and compositional uniformity of the quaternary layers contained in other nitride layers, which are typical for construction of nitride based devices. The AlInGaN layer was epitaxially compatible to InGaN matrix, strained, and no strain related dislocation creation was observed. The strain penetrated for limited depth, below 3 nm, even for relatively high content of indium (7%). For lower indium content (0.6%), the strain was below the detection limit by TEM strain analysis. The structures containing quaternary AlInGaN layers were studied by time dependent photoluminescence (PL) at different temperatures and excitation powers. It was shown that PL spectra contain three peaks: high energy donor bound exciton peak from the bulk GaN (DX GaN) and the two peaks (A and B) from InGaN layers. No emission from quaternary AlInGaN layers was observed. An accumulation of electrons on the EBL interface in high-In sample and formation of 2D electron gas (2DEG) was detected. The dynamics of 2DEG was studied by time resolved luminescence revealing strong dependence of emission energy on the 2DEG concentration. Theoretical calculations as well as power-dependence and temperature-dependence analysis showed the importance of electric field inside the structure. At the interface, the field was screened by carriers and could be changed by illumination. From these measurements, the dynamics of electric field was described as the discharge of carriers accumulated on the EBL.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics of picosecond pulse laser ablation

This study investigates the physical processes involved in picosecond pulse (20-28 ps FWHM) laser ablation of Al 6061, 316L stainless steel, and undoped crystalline Si ($\langle$100$\rangle$) over a range of laser wavelength (355 nm and 1064 nm) and fluence (0.1-40 J/cm 2 ). Experimental measurements of material ablation rate show enhanced removal at the 355 nm wavelength, primarily due to laser-plasma interaction (LPI) within the ablative plume that approaches an order of magnitude increase over the measured removal at 1064 nm. A transition in the ablation rate at 355 nm is identified around ~10 J/cm 2 above which the removal efficiency increases by a factor of two to three. Multi-physics radiation hydrodynamic simulations, considering LPI effects and utilizing a novel mixed-phase equation of state model, show that the transition in ablation efficiency is due to the onset of melt ejection through cavitation, where laser-driven shock heating sets the depth of melt penetration and the ensuing release wave from the ablation surface drives cavitation through the imposition of tensile strain within the melt. High-speed pump-probe imaging of the ejecta and ejecta collection studies, as well as scanning electron microscopy of the ablation craters, support the proposed cavitation mechanism in the higher fluence range. The ablation process is vitally influenced by LPI effects and the thermophysical properties of the material.

36 MATERIALS SCIENCE↗

Influence of skin surface roughness degree on energy characteristics of light scattered by a biological tissue

We present the results of modelling of photometric characteristics of light in soft tissues illuminated by a parallel beam along the normal to the surface, obtained with allowance for the skin roughness parameters and the angular structure of radiation approaching the surface from within the tissue. The depth structure of the fluence rate and the spectra of the diffuse reflection of light by the tissue in the interval of wavelengths 300 – 1000 nm are considered. We discuss the influence of the tilt angle variance of rough surface microelements and light refraction on the studied characteristics. It is shown that these factors lead to the reduction of the radiation flux only in the near-surface tissue layer and practically do not affect the depth of light penetration into the tissue. On the other hand, the degree of the surface roughness and the conditions of its illumination from within the tissue essentially affect the coefficient of diffuse reflection of light and lead to its considerable growth compared to the cases of a smooth interface and completely diffuse illumination, often considered to simplify the theoretical problem solution. The role of the roughness of skin surface is assessed in application to the solution of different direct and inverse problems of biomedical optics. (paper)

60 APPLIED LIFE SCIENCES↗

Injected mass deposition thresholds for lithium granule instigated triggering of edge localized modes on EAST

The ability of an injected lithium granule to promptly trigger an edge localized mode (ELM) has been established in multiple experiments. By horizontally injecting granules ranging in diameter from 200 microns to 1mm in diameter into the low field side of EAST H-mode discharges we have determined that granules with diameter > 600 microns are successful in triggering ELMs more than 95% of the time. Granules were radially injected from the outer midplane with velocities ~ 80 m/s into EAST upper-single null discharges with an ITER like tungsten monoblock divertor. ELM triggering was a prompt response to granule injection, and for granules of a sufficient size there was no evidence of a "trigger lag" phenomenon as observed in full metal machines. We also demonstrated that the triggering efficiency decreased with granule size during dynamic size scans. These granules were individually tracked throughout their injection cycle in order to determine their efficacy at triggering an ELM. Furthermore, by simulating the granule injection with an experimentally benchmarked neutral gas shielding (NGS) model, the ablatant mass deposition required to promptly trigger an ELM is calculated and the fractional mass deposition is determined. Simulated 900 micron granules capable of triggering an ELM show a peaked mass deposition of 3.9 x 10 17 atoms per mm of penetration at a depth of approximately 5 cm past the separatrix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wide-Bandwidth, Wide-Beamwidth, High-Resolution, Millimeter-Wave Imaging for Concealed Weapon Detection

Active millimeter-wave imaging is currently being used for personnel screening at airports and other high-security facilities. The lateral resolution, depth resolution, clothing penetration, and image illumination quality obtained from next-generation systems can be significantly enhanced through the selection the aperture size, antenna beamwidth, center frequency, and bandwidth. In this paper, the results of an extensive imaging trade study are presented using both planar and cylindrical three-dimensional imaging techniques at frequency ranges of 10-20 GHz, 10 – 40 GHz, 40 – 60 GHz, and 75 – 105 GHz

Concealed-Weapon Detection↗

SU-D-BRB-04: Plan Quality Comparison of Intracranial Stereotactic Radiosurgery (SRS) for Gamma Knife and VMAT Treatments

Purpose: To compare treatment plan quality of intracranial stereotactic radiosurgery (SRS) for VMAT (RapidArc) and Gamma Knife (GK) systems. Methods: Ten patients with 24 tumors (seven with 1–2 and three with 4–6 lesions), previously treated with GK 4C (prescription doses ranging from 14–23 Gy) were re-planned for RapidArc. Identical contour sets were kept on MRI images for both plans with tissues assigned a CT number of zero. RapidArc plans were performed using 6 MV flattening-filter-free (FFF) beams with dose rate of 1400 MU/minute using two to eight arcs with the following combinations: 2 full coplanar arcs and the rest non-coplanar half arcs. Beam selection was based on target depth. Areas that penetrated more than 10 cm of tissue were avoided by creating smaller arcs or using avoidance sectors in optimization. Plans were optimized with jaw tracking and a high weighting to the normal-brain-tissue and Normal-Tissue-Objective without compromising PTV coverage. Plans were calculated on a 1 mm grid size using AAA algorithm and then normalized so that 99% of each target volume received the prescription dose. Plan quality was assessed by target coverage using Paddick Conformity Index (PCI), sparing of normal-brain-tissue through analysis of V4, V8, and V12 Gy, and integral dose. Results: In all cases critical structure dose criteria were met. RapidArc had a higher PCI than GK plans for 23 out of 24 lesions. The average PCI was 0.76±0.21 for RapidArc and 0.46±0.20 for GK plans (p≤0.001), respectively. Integral dose and normal-brain-tissue doses for all criteria were lower for RapidArc in nearly all patients. The average ratio of GK to RapidArc plans was 1.28±0.27 (p=0.018), 1.31±0.25 (p=0.017), 1.81±0.43 (p=0.005), and 1.50±0.61 (p=0.006) for V4, V8, and V12 Gy, and integral dose, respectively. Conclusion: VMAT was capable of producing higher quality treatment plans than GK when using optimal beam geometries and proper optimization techniques.

60 APPLIED LIFE SCIENCES↗

Edge Vibrations of Graphane Nanoribbons

Using the COMPASS force field, natural linear vibrations of graphane (graphene hydrogenated on both sides) nanoribbons are simulated. The frequency spectrum of a graphane sheet consists of three continuous intervals (low-frequency, mid-frequency, and narrow high-frequency) and two gaps between them. The construction of dispersion curves for nanoribbons with a zigzag and chair structure of the edges show that the frequencies of edge vibrations (edge phonons) can be present in the gaps of the frequency spectrum. In the first type of nanoribbons, two dispersion curves are in the low-frequency gap of the spectrum and four dispersion curves in the second gap. These curves correspond to phonons moving only along the nanoribbon edges (the mean depth of their penetration toward the nanoribbon center does not exceed 0.15 nm).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fraunhofer line-dept sensing applied to water

An experimental Fraunhofer line discriminator is basically an airborne fluorometer, capable of quantitatively measuring the concentration of fluorescent substances dissolved in water. It must be calibrated against standards and supplemented by ground-truth data on turbidity and on approximate vertical distribution of the fluorescent substance. Quantitative use requires that it be known in advance what substance is the source of the luminescence emission; qualitative sensing, or detection of luminescence is also possible. The two approaches are fundamentally different, having different purposes, different applications, and different instruments. When used for sensing of Rhodamine WT dye in coastal waters and estuaries, the FLD is sensing in the spectral region permitting nearly maximum depth of light penetration.

Stoertz, G. E.↗

Analysis of the theory of high energy ion transport

Procedures for the approximation of the transport of high-energy ions are discussed on the basis of available data on ion nuclear reactions. A straightahead approximation appears appropriate for space applications. The assumption that the secondary-ion-fragment velocity is equal to that of the fragmenting nucleus is inferior to straightahead theory but is of sufficient accuracy if the primary ions display a broad energy spectrum. An iterative scheme for the solution of the inhomogenous integral transport equations holds promise for practical calculation. A model calculation shows that multiple charged ion fragments penetrate to greater depths in comparison with the free path of a primary heavy ion.

Wilson, J. W.↗

Imaging of X-ray aurorae from Spacelab

The Atmospheric X-ray Emission Telescope (AXET) is designed to image and measure the spatial, temporal, and spectral distributions of X-ray aurorae produced in the upper atmosphere by precipitating energetic electrons. The bremsstrahlung-produced X radiation penetrates to stratospheric depths where it can modify ozone, conductivity, and other critical atmospheric parameters. Remote sensing of this radiation from topside will provide vital data on solar-terrestrial relationships and mechanisms that could help trigger tropospheric response to solar activity. The X rays also provide direct information concerning the dynamics of radiation-belt processes within the magnetosphere. AXET is designed to detect sources up to 50 keV and to image them below 25 keV by means of directionally sensitive proportional counters with passive collimators. It will be mounted in the Space Shuttle on a single fixed platform designed to optimize viewing conditions for the anticipated orbits and aspects of early Spacelab missions.

Goldberg, R. A.↗

Wire stripper

An insulation stripper is described which is especially useful for shielded wire, the stripper including a first pair of jaws with blades extending substantially perpendicular to the axis of the wire, and a second pair of jaws with blades extending substantially parallel to the axis of the wire. The first pair of jaws is pressed against the wire so the blades cut into the insulation, and the device is turned to form circumferential cuts in the insulation. Then the second pair of jaws is pressed against the wire so the blades cut into the insulation, and the wire is moved through the device to form longitudinal cuts that permit easy removal of the insulation. Each of the blades is located within the concave face of a V-block, to center the blades on the wire and to limit the depth of blade penetration.

Economu, M. A.↗

Silicon solar cell fabrication technology

The laser cell scanner was used to characterize a number of solar cells made in various materials. An electron beam-induced current (EBIC) study was performed using a stereoscan scanning electron microscope. Planar p-n junctions were analyzed. A theory for the EBIC based on the analytical solution of the ambipolar diffusion equation under the influence of electron beam excitation parameter z (which is related to beam penetration), the junction depth Z sub j, the beam current and the surface recombination, was formulated and tested. The effect of a grain boundary was studied.

Stafsudd, O. M.↗

Impactor control of central peak and peak-ring formation

The relation between the depth and diameter of excavation for impacts typically is assumed to be proportional. Such an assumption is consistent with the constant aspect ratio (diameter:depth) observed for simple craters found in a wide range of planetary settings and crater-scaling laws derived from laboratory experiments. Although complex craters exhibit evidence for floor uplift and rim collapse of a transient profile, they are typically thought to resemble initially smaller, simple craters. At large scales, however, early-time processes consume a greater fraction of crater growth and the assumption of late-time equivalence of energy release as a point source becomes inappropriate. The authors propose instead that crater diameter, depth, and impactor penetration represent separable dependent variables that underscore the fundamental difference between impact and point-source explosion excavation processes. An important consequence of this perspective is that central pits, peaks, and rings may represent contrasting target responses to impactor penetration and could provide an important indicator of impactor dimensions.

Schultz, Peter H.↗

The Mars Microprobe Mission: Advanced Micro-Avionics for Exploration Surface

The Mars Microprobe Mission is the second spacecraft developed as part of the New Millennium Program deep space missions. The objective of the Microprobe Project is to demonstrate the applicability of key technologies for future planetary missions by developing two probes for deployment on Mars. The probes are designed with a single stage entry, descent, and landing system and impact the Martian surface at speeds of approximately 200 meters per second. The microprobes are composed of two main sections, a forebody section that penetrates to a depth below the Martian surface of 0.5 to 2 meters, and an aftbody section that remains on the surface. Each probe system consists of a number of advanced technology components developed specifically for this mission. These include a non-erosive aeroshell for entry into. the atmosphere, a set of low temperature batteries to supply probe power, an advanced microcontroller to execute the mission sequence, collect the science data, and react to possible system fault conditions, a telecommunications subsystem implemented on a set of custom integrated circuits, and instruments designed to provide science measurements from above and below the Martian surface. All of the electronic components have been designed and fabricated to withstand the severe impact shock environment and to operate correctly at predicted temperatures below -100 C.

Blue, Randel↗

Lunar and Planetary Science XXXV: Mars: Radar, Gamma Ray Spectrometer, and Cratering Mineralogy

The session "Mars: Radar, Gamma Ray Spectrometer, and Cratering Mineralogy" contained the following reports:The Dielectric Properties of Martian Soil Simulant JSC Mars-1 in the Range from 20Hz to 10kHz; Eastern Sahara Geology from Orbital Radar: Potential Analog to Mars On the Dielectric Properties of the Martian-like Surface Sediments; Radar Observations of Recent Mars Landing Sites; Sounding of Subsurface Water Through Conductive Media in Mars Analog Environments Using Transient Electromagnetics and Low Frequency Ground-penetrating Radar; Burial Depth of the Reservoirs of Hydrogen at the Equatorial Latitudes on Mars; Elemental Composition Variations for Large Dusty and Rocky Regions on Mars Using Gamma-Ray Data from the Mars Odyssey Gamma-Ray Spectrometer; The Distribution of Non-Volatile Elements on Mars: Mars Odyssey GRS Results; Using Mars Odyssey GRS Data to Assess Models for the Bulk Composition of Mars; Mars: The Terra Arabia Low Epithermal Neutron Flux Anomaly; The Isidis Basin of Mars: New Results from MOLA, MOC, and THEMIS; Remote Sensing of the Haughton Impact Structure (HIS): A Terrestrial Proof of Concept for Using the Remote Sensing of Martian Craters as a Probe of Subsurface Composition;and Thermal Emission Spectra of Impact Glass and Shocked Deccan Basalt from Lonar Crater, India and Implications for Remote Sensing of Mars.

Source record↗