Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERMANENT MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Modelling a Motor Cooling System with Stator Lamination Fins

This work investigates the potential for cooling a radial permanent magnet motor by means of stator lamination fins. To form the fins, certain stator laminations have a larger external diameter. The optimal number of fins, as well as fm thickness, was determined to reach the maximal heat transfer between the motor stator and the coolant. Finite element and computational fluid dynamics modelling were used to calculate the thermal performance of the motor.

ENGINEERING↗

A Fully Adaptive Electromagnetic Suspension System for Vehicles

Recently, electromagnetic suspension systems have become more popular in passenger vehicles. They are superior alternatives to existing conventional passive hydraulic suspension systems. The objective in this paper is to design a new adaptive, not reactive, electromagnetic suspension system. This is performed through two fixed permanent magnets and one electromagnet system packaged as a bolt solution for vehicles. Once combined with other sensors in the vehicle, the proposed electromagnetic system can provide the first fully adaptive suspension system in vehicles.

Davis, Dakota↗

Implementation of a Metamodel-Based Optimization for the Design of a High Power Density Wound Field Traction Motor

Traction motors onboard electric vehicles (EVs) are faced with ever-increasing power density requirements and cost reduction challenges. Although permanent magnet (PM) traction motors have been favored for their potential of higher power densities, the price and supply volatility of PM materials are the major drawbacks. Instead of a single load point, the performance of a traction motor needs to be optimized over various combinations of torque and speed to represent real-world vehicular driving scenarios, which tends to be a time-consuming task with direct optimizations. In this study, as a PM-free solution, a wound field synchronous motor (WFSM) is designed and optimized using a metamodel-based approach to maximize its efficiency over a custom set of load points, while utilizing a fully per-unitized geometry template. The workflow has proven to be timesaving and the optimal design is prototyped and tested.

33 ADVANCED PROPULSION SYSTEMS↗

Development of Solid Synchronous Reluctance Rotors With Multi-Material Additive Manufacturing

Synchronous reluctance (SynR) machines are promising rare-earth material-free alternatives to permanent magnet machines. However, structural challenges limit their operating speed and power density. This paper proposes and investigates multi-material additive manufacturing (MMAM) as a key-enabler to realize power-dense and high-speed SynR machines. It does so by proposing designs that guide magnetic flux through solid rotors realized by selective placement of magnetic and non-magnetic materials. To explore this concept, first, material samples are additively manufactured and experimentally characterized to assess the structural and magnetic properties that can be expected for the proposed rotors. Second, the design space of each rotor type is explored using these measured properties within finite element analysis. The results reveal that MMAM can enable fabrication of SynR motors with power density levels that are at the leading edge of all conventional electric machine topologies. It is shown that tip speeds in excess of 300 m/s can be achieved, resulting in 3-4x improvement in power density over conventional SynR motors. A solid SynR rotor is printed in an experimental MMAM laser powder bed fusion system. The rotor is paired with an existing stator to create a functional SynR motor with a saliency ratio of 2.59 and torque rating of 4.15 Nm. This is the first publication of a SynR rotor prototype constructed via MMAM.

36 MATERIALS SCIENCE↗

Dynamic Characteristics and Test Results of a Wave Power Take-off System with Mechanical Motion Rectification and Transmission

An innovative ocean wave power takeoff (PTO) system is presented here to enhance electrical energy generation from oscillating wave motions. This PTO system, mainly consisting of dual ball screws, gearbox with mechanical motion rectification (MMR) and a permanent magnet synchronous generator (PMSG), can convert bidirectional irregular motions from a floating wave buoy into unidirectional regular generator rotations. Systematical operating principles, design and prototyping details of the PTO system are presented and analyzed. A hydrodynamics-mechanical-electrical model of the system is established by reasonably representing power switches attached to the PMSG as an equivalent external resistance. The overall dynamics of the system are then analyzed in the frequency-domain. Three power control strategies are proposed to maximize the wave power absorption by changing the equivalent external resistance. The effectiveness and relatively high energy conversion efficiency of the PTO system have been demonstrated based on lab bench test results. The levelized cost of energy of a full scale wave energy converter system is also calculated based on the proposed PTO system.

16 TIDAL AND WAVE POWER↗

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

Postfault Operation of Three-Level Inverter Driven Six-Phase PMSM With Enhanced Torque–Speed Region

This article presents an open-switch postfault operational technique with enhanced torque–speed region for three-level (3L) active neutral point clamped (ANPC) inverter-driven symmetrical six-phase (SSP) permanent magnet synchronous machines (PMSMs). Maximum torque (MT), minimum loss (ML), and single three-phase (STP) operations are commonly used for the postfault operations of six-phase drives. The maximum possible torque and speed in these operations are generally limited by voltage, current ratings, and the neutral point configuration of the motor. To enhance the postfault torque and speed operating region, the torque and speed limits in different postfault operational techniques are determined based on the voltage, current constraints, and neutral point configuration of the SSP-PMSM. In this work, a unified postfault operation is proposed that increases the postfault operational limits by combining MT, ML, and STP operations and modifying the neutral point configuration of the SSP-PMSM. In addition, a technique is also presented that modifies the pulsewidth modulation technique to enable full torque operation below 0.5 p.u. speed. The proposed postfault operational technique enables full-speed (1 p.u.) operation by operating in STP mode and full torque operation (1 p.u.) below 0.5 p.u. speed. Furthermore, the postfault operational technique is experimentally validated using a Gallium Nitride (GaN) device-based3L-ANPC inverter-driven SSP-PMSM.

42 ENGINEERING↗

Grid Forming Fast Frequency Response for PMSG-Based Wind Turbines

Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. Further, the results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.

17 WIND ENERGY↗

Common Mode Voltage Compensation for Capacitor Voltage Ripple Reduction of 7-kV SiC-based Modular Multilevel Converter

Abstract -Modular multilevel converters (MMCs), with the filterless and transformer-less features, are considered as a promising topology for high-efficiency medium voltage (MV) high voltage (HV) drive systems. However, a large current ripple flowing through the capacitors of each submodule will cause significant capacitor voltage fluctuation. This paper proposes a new compensation method in common mode voltage injection to further reduce the magnitude of the fundamental component in capacitor voltages. The capacitor voltage ripples are reduced significantly by using the proposed control method, which means that smaller size of capacitors can be used for same voltage ripple requirements. Simulation and experimental test results verify the proposed compensation method using a three-phase permanent magnet synchronous machine (PMSM).

Common mode voltage injection↗

Hybrid-Electric Turbocharger and High-Speed SiC Variable-Frequency Drive Using Sensorless Control Algorithm

Electrically assisted engine boosting systems lend themselves to better throttle response, wider effective operating ranges, and can provide the ability to extract excess energy during deceleration and high-load events (and store it in a vehicle's onboard batteries). This can lead to better overall vehicle performance, emissions, and efficiency while allowing for further engine downsizing and increased power density. In this research effort, a hybrid-electric turbocharger, variable-frequency drive (VFD), and novel sensorless control algorithm were developed. An 11 kW permanent-magnet (PM) machine was coupled to a commercial turbocharger via an in-line, bolt-on housing attached to the compressor inlet. A high-efficiency, high-temperature VFD, consisting of custom control and power electronics, was also developed. The VFD uses SiC MOSFETS to achieve high-switching frequency and can be cooled using an existing engine coolant loop operating at up to 105 °C at an efficiency greater than 98%. A digital sliding mode-observer sensorless speed control algorithm was created to command and regulate speed and achieved ramp rates of over 68,000 rpm/s. A two-machine benchtop motor/generator test stand was constructed for initial testing and tuning of the VFD and sensorless control algorithm. A gas blow-down test stand was constructed to test the mechanical operation of the hybrid-electric turbocharger and speed control using the VFD. In addition, a liquid-pump cart was assembled for high-temperature testing of the VFD. Initial on-engine testing is planned for later this year. This paper intends to present a design overview of the in-line, hybrid-electric device, VFD, and performance characterization of the electronics and sensorless control algorithm.

Engineering↗

Thermal Management System of an Outer-Rotor-Motor-Based Traction Drive With Integrated Power Electronics in its Central Cavity

Increasing power densities of electric vehicle traction drive systems necessitates combining the electric motor and the power electronics into one unit. A compact, integrated traction drive unit with fewer components also drives production costs down, enabling wider adoption of electric vehicles. However, the integration of power electronics in the electric machine is associated with challenges of designing an effective thermal management solution for the combined traction drive system. This paper focuses on the thermal management approach selected for Oak Ridge National Laboratory’s outer-rotor-motor-based integrated traction drive and evaluates its potential performance. The outer-rotor-motor configuration provided an opportunity for integration of the six-phase inverter in the available space in the central cavity of the internal stator. A cylindrical inverter enclosure with integrated coolant (water-ethylene glycol) channels in its walls was designed to enable heat removal from the power electronics. Numerical thermal-fluid modeling and initial channel/fin optimization results for the cylindrical heat sink are presented here. As permanent magnets are integrated in a high-speed (20 000 RPM) outer rotor, forced air convection provides cooling for the magnets. The magnets were segmented axially to mitigate the eddy current losses. Heat generated in the stator windings and laminations is removed by water-ethylene glycol coolant circulating in interpolar T-shape ceramic heat exchangers inserted between windings. General design concepts and numerical thermal-fluid simulations illustrating the electric motor thermal management solution are also presented.

Kekelia, Bidzina↗

Simulation of the CBETA 4-pass FFAG ERL using field maps — exclusively

The Cornell-BNL Electron Test Accelerator (CBETA), a four-pass, 150 MeV energy recovery linac (ERL), is now in construction at Cornell. Commissioning commenced on March 2019. A particularity of CBETA is that a single channel loop recirculates the four energies (42, 78, 114 and 150 MeV). The return loop arcs are based on fixed-field alternating gradient (FFAG) optics. The loop is comprised of 107 quadrupole-doublet cells, built using Halbach permanent magnet technology. Spreader and combiner sections (4 independent beam lines each) connect the 36 MeV linac to the FFAG arcs. We introduce here a start-to-end simulation of the 4-pass ERL, based entirely, and exclusively, on the use of magnetic field maps to model the optical components.

43 PARTICLE ACCELERATORS↗

Interplays In The Rare Earth Element Value Chain

An imbalance problem exists in the rare earth element (REE) market with cerium and lanthanum being more abundant and less valuable than REEs used in permanent magnets such as neodymium, praseodymium, and dysprosium. Research has been conducted on new applications for abundant REEs to improve mining economics. However, potential market impacts of these applications on individual REE commodities are unknown. A system dynamics model was built to investigate the impacts of a new aluminum-cerium (Al-Ce) alloy that can theoretically utilize three separate cerium forms: cerium carbonate, cerium oxide, or cerium metal. Cerium carbonate currently possesses the lowest price of the three available forms making it initially the most favorable choice. However, model results showed that cerium oxide could provide the best economics for future Al-Ce alloy deployment because its larger market size buffers major shocks to price.

Severson, Michael [Idaho National Laboratory (INL)↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

In-Situ Blade Strain Measurements of a Crossflow Turbine Operating in a Tidal Flow

This data was collected between October 25 and December 12 of 2022 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). The goal was to collect blade strain data from a crossflow turbine operating in a tidal flow. A table in ('Deployment Schedule.PNG') outlines the various dates when each instrument was operational, and more details can be found via literature listed in 'Related Publications'.txt. This dataset includes zipped folders for each instrument containing data in .csv files for the relevant duration specific to each instrument, along with separate README file for each measurement. Some instrument files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. All data contained in this submission is unfiltered/unprocessed data unless otherwise noted in the README file. Blade strain was measured using 8 foil-based strain gauges along the span of a single turbine blade. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) both upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal flow with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Chancey 2019. The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. A single blade of this turbine was further modified to accommodate 8 full-bridge strain gauges (Bharath et al 2023, Bichanich et al 2024). For power performance and other relevant details on the turbine and its characteristics, see O'Byrne 2022.

16 TIDAL AND WAVE POWER↗

Caloric effects in ferroic materials

The fundamentals and applications of ferroic materials$-$ferromagnetic, ferroelectric, and ferroelastic$-$are common subjects discussed in just about every graduate course related to functional materials. Looking beyond today’s traditional uses, such as in permanent magnets, capacitors, and shape-memory alloys, there are worthwhile and interesting questions common to the caloric properties of these ferroic materials. Can ferroic materials be used in a cooling cycle? Why are these materials susceptible to external fields? Which combination of properties is required to make some of them suitable for efficient cooling and heat pumping? We address these questions in this introduction to ferroic cooling, which comprises magnetocaloric, electrocaloric, elastocaloric and barocaloric approaches and combinations thereof (i.e., multicalorics). These are addressed in greater detail in the articles in this issue.

36 MATERIALS SCIENCE↗

Simulation of Bunch Formation for the Mu2e Experiment

The Fermilab Recycler is an 8 GeV storage ring composed of permanent magnets that was crucial to the success of the Fermilab Tevatron Collider program. It is currently being used to slip-stack protons for the high energy neutrino program and to re-bunch protons for use in the Muon g-2 and Mu2e experiments. For the latter applications, the Recycler re-bunches each 1.6 µs "batch" from the Fermilab Booster into four 2.5 MHz bunches. For the Mu2e experiment, it is crucial that beam more than 125 ns from the nominal bunch center be suppressed by at least a factor of 1E-5. While bunch formation is currently in operation for the g-2 experiment, this out of time requirement has not been met, and the reason is not understood. This work presents a simulation of bunch formation in the Recycler, in an effort to understand the reason for this excessive out of time beam and to search for a way to reduce it.

43 PARTICLE ACCELERATORS↗

CEBAF 22 GeV FFA energy upgrade

Extending the energy reach of CEBAF by increasing the number of recirculations, while using the existing linacs is explored. This energy upgrade is based on the multi-pass acceleration of electrons in a single non-scaling Fixed Field Alternating Gradient (FFA) beam line, using Halbach-style permanent magnets. Encouraged by the recent successful demonstration of CBETA, a proposal was formulated to nearly double the energy of CEBAF from 12 to 22~GeV by replacing the highest energy arcs with FFA transport. The new FFA arcs would support simultaneous transport of an additional 6 passes spanning roughly a factor of two in energy. One of the challenges of the multi-pass (11) linac optics is to assure uniform focusing over a wide range of energies. Here, we propose a triplet lattice that provides a stable periodic solution covering an energy ratio of 1:33. The current CEBAF injection at 123 MeV, makes optical matching in the first linac impossible due to the extremely high energy ratio (1:175). Replacement of the current injector with a 650 MeV recirculating injector will alleviate this issue. Orbital and optical matching from the FFA arcs to the linacs is implemented as a compact non-adiabatic insert. The design presented here is anticipated to deliver a 22 GeV beam with normalized emittance of 76 mm·mrad and a relative energy spread of 1×10\textsuperscript{-3}. Further recirculation beyond 22 GeV is limited by the large (974 MeV per electron) energy loss due to synchrotron radiation.

Benesch, J.↗