Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Dust streaks on Mars: Colors and photometry

Photometric studies of crater related bright and dark streaks have strongly supported the hypothesis that the bright streaks are excess dust deposits and dark streaks are erosional windows in a partial dust cover. Red-blue (and red-violet) plots show that bright streaks are consistent with mosaics of bright red dust and background material. Here the plains are also consistent with a partial dust cover; the dark streak is the least covered area. Bright and dark streaks both reverse contrast relative to surrounding plains at phase angles over 100 deg in violet filter images. The similar phase behavior of both bright and dark streaks supports the idea that they are both changes in the amount of dust cover. Red-violet plots of bright streaks are most easily explained by mosaics of optically thick dust and plains material. Lengths of bright streaks are independent of their contrasts. This suggests the streak deposition, if in the mosaic patterns indicated above, is a function of available sites of deposition, rather than atmospheric dust loading. Contrasts of dark streaks with plains indicate the plains have fractional dust covers nealy as great as the maximum additional cover in bright streaks. The bright streaks thus store little of the global supply of dust.

Thomas, P.↗

Wavelength dependence of limb-darkening of Mars from visible and near-IR telescopic spectral imaging

We are investigating the photometric properties of Mars using Earthbased telescopic spectral imaging obtained during 1988. Each spatial pixel consists of 300 spectral channels from 0.44 to 1.02 microns, calibrated to radiance factor (r(sub F)) through a careful procedure involving standard star observations in 1988 and 1990. Calibrated data include 3 spectral images with solar phase angle (g) of 12 degrees and 4 images with g of 4 degrees. Pixels near the sub-Earth point have a spatial footprint of about 280 x 150 km. Preliminary work using Hapke photometric function reveals a dependence of both single-scattering albedo and roughness parameter on wavelength. The former is in agreement with observed spectra of the martian surface, but the latter is unexpected.

Pierazzo, E.↗

Online monitoring of oil film using electrical capacitance tomography and level set method

In the application of oil-air lubrication system, electrical capacitance tomography (ECT) provides a promising way for monitoring oil film in the pipelines by reconstructing cross sectional oil distributions in real time. While in the case of small diameter pipe and thin oil film, the thickness of the oil film is hard to be observed visually since the interface of oil and air is not obvious in the reconstructed images. And the existence of artifacts in the reconstructions has seriously influenced the effectiveness of image segmentation techniques such as level set method. Besides, level set method is also unavailable for online monitoring due to its low computation speed. To address these problems, a modified level set method is developed: a distance regularized level set evolution formulation is extended to image two-phase flow online using an ECT system, a narrowband image filter is defined to eliminate the influence of artifacts, and considering the continuity of the oil distribution variation, the detected oil-air interface of a former image can be used as the initial contour for the detection of the subsequent frame; thus, the propagation from the initial contour to the boundary can be greatly accelerated, making it possible for real time tracking. To testify the feasibility of the proposed method, an oil-air lubrication facility with 4 mm inner diameter pipe is measured in normal operation using an 8-electrode ECT system. Both simulation and experiment results indicate that the modified level set method is capable of visualizing the oil-air interface accurately online.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NIAC Phase II Orbiting Rainbows: Future Space Imaging with Granular Systems

Inspired by the light scattering and focusing properties of distributed optical assemblies in Nature, such as rainbows and aerosols, and by recent laboratory successes in optical trapping and manipulation, we propose a unique combination of space optics and autonomous robotic system technology, to enable a new vision of space system architecture with applications to ultra-lightweight space optics and, ultimately, in-situ space system fabrication. Typically, the cost of an optical system is driven by the size and mass of the primary aperture. The ideal system is a cloud of spatially disordered dust-like objects that can be optically manipulated: it is highly reconfigurable, fault-tolerant, and allows very large aperture sizes at low cost. This new concept is based on recent understandings in the physics of optical manipulation of small particles in the laboratory and the engineering of distributed ensembles of spacecraft swarms to shape an orbiting cloud of micron-sized objects. In the same way that optical tweezers have revolutionized micro- and nano-manipulation of objects, our breakthrough concept will enable new large scale NASA mission applications and develop new technology in the areas of Astrophysical Imaging Systems and Remote Sensing because the cloud can operate as an adaptive optical imaging sensor. While achieving the feasibility of constructing one single aperture out of the cloud is the main topic of this work, it is clear that multiple orbiting aerosol lenses could also combine their power to synthesize a much larger aperture in space to enable challenging goals such as exo-planet detection. Furthermore, this effort could establish feasibility of key issues related to material properties, remote manipulation, and autonomy characteristics of cloud in orbit. There are several types of endeavors (science missions) that could be enabled by this type of approach, i.e. it can enable new astrophysical imaging systems, exo-planet search, large apertures allow for unprecedented high resolution to discern continents and important features of other planets, hyperspectral imaging, adaptive systems, spectroscopy imaging through limb, and stable optical systems from Lagrange-points. Furthermore, future micro-miniaturization might hold promise of a further extension of our dust aperture concept to other more exciting smart dust concepts with other associated capabilities. Our objective in Phase II was to experimentally and numerically investigate how to optically manipulate and maintain the shape of an orbiting cloud of dust-like matter so that it can function as an adaptable ultra-lightweight surface. Our solution is based on the aperture being an engineered granular medium, instead of a conventional monolithic aperture. This allows building of apertures at a reduced cost, enables extremely fault-tolerant apertures that cannot otherwise be made, and directly enables classes of missions for exoplanet detection based on Fourier spectroscopy with tight angular resolution and innovative radar systems for remote sensing. In this task, we have examined the advanced feasibility of a crosscutting concept that contributes new technological approaches for space imaging systems, autonomous systems, and space applications of optical manipulation. The proposed investigation has matured the concept that we started in Phase I to TRL 3, identifying technology gaps and candidate system architectures for the space-borne cloud as an aperture.

Quadrelli, Marco B.↗

Ice Growth Measurements from Image Data to Support Ice-Crystal and Mixed-Phase Accretion Testing

This paper describes the imaging techniques as well as the analysis methods used to measure the ice thickness and growth rate in support of ice-crystal icing tests performed at the National Research Council of Canada (NRC) Research Altitude Test Facility (RATFac). A detailed description of the camera setup, which involves both still and video cameras, as well as the analysis methods using the NASA Spotlight software, are presented. Two cases, one from two different test entries, showing significant ice growth are analyzed in detail describing the ice thickness and growth rate which is generally linear. Estimates of the bias uncertainty are presented for all measurements. Finally some of the challenges related to the imaging and analysis methods are discussed as well as methods used to overcome them.

Struk, Peter, M↗

Propagation-based phase-contrast tomography for high-resolution lung imaging with laboratory sources

We have performed high-resolution phase-contrast tomography on whole mice with a laboratory setup. Enabled by a high-brilliance liquid-metal-jet source, we show the feasibility of propagation-based phase contrast in local tomography even in the presence of strongly absorbing surrounding tissue as it is the case in small animal imaging of the lung. We demonstrate the technique by reconstructions of the mouse lung for two different fields of view, covering the whole organ, and a zoom to the local finer structure of terminal airways and alveoli. With a resolution of a few micrometers and the wide availability of the technique, studies of larger biological samples at the cellular level become possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dissociative electron attachment studies of gas-phase acetic acid using a velocity map imaging technique

Abstract Advancing instrumentation to explore dissociative electron attachment (DEA) studies allows previously unattainable information to be acquired. Using a newly constructed velocity map imaging spectrometer, we revisited a study on DEA to gas-phase acetic acid. We discuss possible fragmentation channels and compared the corresponding ion yields with previous high electron-energy resolution results. We focus on the channels occurring at higher energies, particularly near 10 eV, and calculate their thermodynamic thresholds. Moreover, we expand previous studies and perform time-sliced imaging near the 10 eV resonance to obtain the kinetic energy distribution of the fragment ions.

Optics↗

Automated Recognition Of Melt Lines In Phase-Change Paints

Technique developed to reduce data quickly and objectively in images of phase-change paints. Involves use of three-tube color-camera system. Camera modified so separate red (R), green (G), and blue (B) video outputs contain complete framing information recorded and digitized by use of standard video format. Proven very simple and repeatable. Used wherever rapid and accurate remote temperature-profile measurements desired; for example, for test objects in inaccessible, toxic, or other hostile areas.

Buck, Gregory M.↗

Analytical Model of the Nonlinear Dynamics of Cantilever Tip-Sample Surface Interactions for Various Acoustic-Atomic Force Microscopies

A comprehensive analytical model of the interaction of the cantilever tip of the atomic force microscope (AFM) with the sample surface is developed that accounts for the nonlinearity of the tip-surface interaction force. The interaction is modeled as a nonlinear spring coupled at opposite ends to linear springs representing cantilever and sample surface oscillators. The model leads to a pair of coupled nonlinear differential equations that are solved analytically using a standard iteration procedure. Solutions are obtained for the phase and amplitude signals generated by various acoustic-atomic force microscope (A-AFM) techniques including force modulation microscopy, atomic force acoustic microscopy, ultrasonic force microscopy, heterodyne force microscopy, resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), and the commonly used intermittent contact mode (TappingMode) generally available on AFMs. The solutions are used to obtain a quantitative measure of image contrast resulting from variations in the Young modulus of the sample for the amplitude and phase images generated by the A-AFM techniques. Application of the model to RDF-AFUM and intermittent soft contact phase images of LaRC-cp2 polyimide polymer is discussed. The model predicts variations in the Young modulus of the material of 24 percent from the RDF-AFUM image and 18 percent from the intermittent soft contact image. Both predictions are in good agreement with the literature value of 21 percent obtained from independent, macroscopic measurements of sheet polymer material.

Cantrell, John H., Jr.↗

Inverse Normalization Method for Cross-Sectional Imaging and Velocimetry of Two-Phase Flows Based on Electrical Capacitance Tomography

Proper normalization of the measured capacitance data is a prerequisite in electrical capacitance tomography (ECT). Conventional methods, such as parallel and series normalization, assume a higher permittivity perturbation in a homogeneous (lower) permittivity background. Although this is applicable to a number of cases, some two-phase flows are better modeled instead as a lower permittivity perturbation in a homogeneous (higher) permittivity background. A different normalization method is proposed for such cases, which provides similar image quality as conventional, but is particularly beneficial for velocimetry applications based on sensitivity gradient of ECT sensor. Furthermore, simulation and experimental results are provided to illustrate the advantages for the proposed normalization technique.

47 OTHER INSTRUMENTATION↗

Differential phase acoustic microscope for micro-NDE

A differential phase scanning acoustic microscope (DP-SAM) was developed, fabricated, and tested in this project. This includes the acoustic lens and transducers, driving and receiving electronics, scanning stage, scanning software, and display software. This DP-SAM can produce mechanically raster-scanned acoustic microscopic images of differential phase, differential amplitude, or amplitude of the time gated returned echoes of the samples. The differential phase and differential amplitude images provide better image contrast over the conventional amplitude images. A specially designed miniature dual beam lens was used to form two foci to obtain the differential phase and amplitude information of the echoes. High image resolution (1 micron) was achieved by applying high frequency (around 1 GHz) acoustic signals to the samples and placing two foci close to each other (1 micron). Tone burst was used in this system to obtain a good estimation of the phase differences between echoes from the two adjacent foci. The system can also be used to extract the V(z) acoustic signature. Since two acoustic beams and four receiving modes are available, there are 12 possible combinations to produce an image or a V(z) scan. This provides a unique feature of this system that none of the existing acoustic microscopic systems can provide for the micro-nondestructive evaluation applications. The entire system, including the lens, electronics, and scanning control software, has made a competitive industrial product for nondestructive material inspection and evaluation and has attracted interest from existing acoustic microscope manufacturers.

Waters, David D.↗

Probing the meta-stability of oxide core/shell nanoparticle systems at atomic resolution

Hybrid nanoparticles allow exploiting the interplay of confinement, proximity between different materials and interfacial effects. However, to harness their properties an in-depth understanding of their (meta)stability and interfacial characteristics is crucial. This is especially the case of nanosystems based on functional oxides working under reducing conditions, which may severely impact their properties. Here, the in-situ electron-induced selective reduction of Mn 3 O 4 to MnO is studied in magnetic Fe 3 O 4 /Mn 3 O 4 and Mn 3 O 4 /Fe 3 O 4 core/shell nanoparticles by means of high-resolution scanning transmission electron microscopy combined with electron energy-loss spectroscopy. Such in-situ transformation allows mimicking the actual processes in operando environments. A multi-stage image analysis using geometric phase analysis combined with particle image velocity enables direct monitoring of the relationship between structure, chemical composition and strain relaxation during the Mn 3 O 4 reduction. In the case of Fe 3 O 4 /Mn 3 O 4 core/shell the transformation occurs smoothly without the formation of defects. However, for the inverse Mn 3 O 4 /Fe 3 O 4 core/shell configuration the electron beam-induced transformation occurs in different stages that include redox reactions and void formation followed by strain field relaxation via formation of defects. This study highlights the relevance of understanding the local dynamics responsible for changes in the particle composition in order to control stability and, ultimately, macroscopic functionality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-428: Feasibility Study of 4D Image Reconstruction by Organ Motion Vector Extension Based On Portal Images

Purpose: To develop and to test a method to generate a new 4D CT images of the treatment day from the old 4D CT and the portal images of the day when the motion extent exceeded from that represented by plan CTs. Methods: A motion vector of a moving tumor in a patient may be extended to reconstruct the tumor position when the motion extent exceeded from that represented by plan CTs. To test this, 1. a phantom that consists of a polystyrene cylinder (tumor) embedded in cork (lung) was placed on a moving platform with 4 sec/cycle and amplitudes of 1 cm and 2 cm, and was 4D-scanned. 2. A 6MV photon beam was irradiated on the moving phantoms and cineEPID images were obtained. 3. A motion vector of the tumor was acquired from 4D CT images of the phantom with 1 cm amplitude. 4. From cine EPID images of the phantom with the 2 cm amplitude, various motion extents (0.3 cm, 0.5 cm, etc) were acquired and programmed into the motion vector, producing CT images at each position. 5. The reconstructed CT images were then compared with pre-acquired “reference” 4D CT images at each position (i.e. phase). Results: The CT image was reconstructed and compared with the reference image, showing a slight mismatch in the transition direction limited by voxel size (slice thickness) in CT image. Due to the rigid nature of the phantom studied, the modeling the displacement of the center of object was sufficient. When deformable tumors are to be modeled, more complex scheme is necessary, which utilize cine EPID and 4D CT images. Conclusion: The new idea of CT image reconstruction was demonstrated. Deformable tumor movements need to be considered in the future.

60 APPLIED LIFE SCIENCES↗

Laboratory Demonstration of Phase Induced Amplitude Apodization (PIAA) Coronagraph with Better than 10(exp -9) Contrast

We present coronagraphic images from the Phase Induced Amplitude Apodization (PIAA) coronagraph on NASA's High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Lab, showing contrasts of 5x10(exp -1) averaged from 2-4 lambda/D, in monochromatic light at 808 nm. In parallel with the coronagraph and its deformable mirror and coronagraphic wavefront control, we also demonstrate a low-order wavefront control system, giving 100 x rms suppression of introduced tip/tilt disturbances down to residual levels of 10(exp -3) lambda/D. Current limitations, as well as broadband (10% fractional bandpass) preliminary results are discussed.

deformable mirror (DM)↗

Phase II Trial of Hypofractionated Image-Guided Intensity-Modulated Radiotherapy for Localized Prostate Adenocarcinoma

Purpose: To assess in a prospective trial the feasibility and late toxicity of hypofractionated radiotherapy (RT) for prostate cancer. Methods and Materials: Eligible patients had clinical stage T1c-2cNXM0 disease. They received 60 Gy in 20 fractions over 4 weeks with intensity-modulated radiotherapy including daily on-line image guidance with intraprostatic fiducial markers. Results: Between June 2001 and March 2004, 92 patients were treated with hypofractionated RT. The cohort had a median prostate-specific antigen value of 7.06 ng/mL. The majority had Gleason grade 5-6 (38%) or 7 (59%) disease, and 82 patients had T1c-T2a clinical staging. Overall, 29 patients had low-risk, 56 intermediate-risk, and 7 high-risk disease. Severe acute toxicity (Grade 3-4) was rare, occurring in only 1 patient. Median follow-up was 38 months. According to the Phoenix definition for biochemical failure, the rate of biochemical control at 14 months was 97%. According to the previous American Society for Therapeutic Radiology and Oncology definition, biochemical control at 3 years was 76%. The incidence of late toxicity was low, with no severe (Grade {>=}3) toxicity at the most recent assessment. Conclusions: Hypofractionated RT using 60 Gy in 20 fractions over 4 weeks with image guidance is feasible and is associated with low rates of late bladder and rectal toxicity. At early follow-up, biochemical outcome is comparable to that reported for conventionally fractionated controls. The findings are being tested in an ongoing, multicenter, Phase III trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlocal Talbot self-imaging with incoherent light

We report a demonstration of nonlocal second-order correlation Talbot effects with incoherent thermal light in a lensless setup containing two optical paths. Self-images of the periodic object, including fractional and phase-reversal Talbot images, are observed at specific distances, in agreement with the theoretical analysis. It is also found that the image quality can be greatly enhanced when higher-order correlations are taken.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗