Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

RFI-SIM: RFI Simulation Package

RFI-SIM simulates the RFI environment to estimate the interference from terrestrial emitters into spacecraft, or vice versa. A high-fidelity simulation of the RFI environment has been developed by employing all antenna- related and radar system-related parameters of multiple emitters, as well as that of the desired spacecraft. In the simulation, the real-time analysis of the interference and its effects on error budgets of a desired radar system is taken into account. This provides a reliable tool for radar system design to deal with RFI issues and to evaluate the sensitivity of various parts of a radar system including antenna pattern, RF front-end and digital processing to RFI signals.

Ghaemi, Hirad↗

Overview of NASA GRCs Green Propellant Infusion Mission Thruster Testing and Plume Diagnostics

The Green Propellant Infusion Mission (GPIM) is sponsored by NASA's Space Technology Mission Directorate (STMD) Technology Demonstration Mission (TDM) office. The goal of GPIM is to advance the technology readiness level of a green propulsion system, specifically, one using the monopropellant, AF-M315E, by demonstrating ground handling, spacecraft processing, and on-orbit operations. One of the risks identified for GPIM is potential contamination of sensitive spacecraft surfaces from the effluents in the plumes of AF-M315E thrusters. NASA Glenn Research Center (GRC) is conducting activities to characterize the effects of AF-M315E plume impingement and deposition. GRC has established individual plume models of the 22-N and 1-N thrusters that will be used on the GPIM spacecraft. The models describe the pressure, temperature, density, Mach number, and species concentration of the AF-M315E thruster exhaust plumes. The models are being used to assess the impingement effects of the AF-M315E thrusters on the GPIM spacecraft. The model simulations will be correlated with plume measurement data from Laboratory and Engineering Model 22-N, AF-M315E thrusters. The thrusters will be tested in a small rocket, altitude facility at NASA GRC. The GRC thruster testing will be conducted at duty cycles representatives of the planned GPIM maneuvers. A suite of laser-based diagnostics, including Raman spectroscopy, Rayleigh spectroscopy, Schlieren imaging, and physical probes will be used to acquire plume measurements of AFM315E thrusters. Plume data will include temperature, velocity, relative density, and species concentration. The plume measurement data will be compared to the corresponding simulations of the plume model. The GRC effort will establish a data set of AF-M315E plume measurements and a plume model that can be used for future AF-M315E applications.

green Propellants↗

The Green Propellant Infusion Mission Thruster Performance Testing for Plume Diagnostics

The Green Propellant Infusion Mission (GPIM) is sponsored by NASA's Space Technology Mission Directorate (STMD) Technology Demonstration Mission (TDM) office. The goal of GPIM is to advance the technology readiness level of a green propulsion system, specifically, one using the monopropellant, AF-M315E, by demonstrating ground handling, spacecraft processing, and on-orbit operations. One of the risks identified for GPIM is potential contamination of sensitive spacecraft surfaces from the effluents in the plumes of AF-M315E thrusters. NASA Glenn Research Center (GRC) is conducting activities to characterize the effects of AF-M315E plume impingement and deposition. GRC has established individual plume models of the 22-N and 1-N thrusters that will be used on the GPIM spacecraft. The model simulations will be correlated with plume measurement data from Laboratory and Engineering Model 22-N, AF-M315E thrusters. The thrusters are currently being tested in a small rocket, altitude facility at NASA GRC. A suite of diagnostics, including Raman spectroscopy, Rayleigh spectroscopy, and Schlieren imaging are being used to acquire plume measurements of AF-M315E thrusters. Plume data will include temperature, velocity, relative density, and species concentration. The plume measurement data will be compared to the corresponding simulations of the plume model. The GRC effort will establish a data set of AF-M315E plume measurements and a plume model that can be used for future AF-M315E applications.

Green Propellants↗

Orion Versus Poseidon: Understanding How Nasa's Crewed Capsule Survives Nature's Fury

This presentation summarizes the Marshall Space Flight Center Natural Environments Terrestrial and Planetary Environments (TPE) Team support to the NASA Orion space vehicle. The Orion vehicle, part of the Multi-Purpose Crew Vehicle Program, is designed to carry astronauts beyond low-Earth orbit and is currently undergoing a series of tests including Exploration Flight Test (EFT)-1. This design must address the natural environment to which the capsule and launch vehicle are exposed during all mission phases. In addition, the design must, to the best extent possible, implement the same process and data to be utilized on launch day. The TPE utilizes meteorological data to assess the sensitivities of the vehicle due to the terrestrial environment. The presentation describes examples of TPE support for vehicle design and several tests, as well as support for EFT-1 and planning for upcoming Exploration Missions while emphasizing the importance of accounting for the natural environment's impact to the vehicle early in the vehicle's program.

Barbre, Robert E., Jr.↗

Dual Extended Kalman Filter for the Identification of Time-Varying Human Manual Control Behavior

A Dual Extended Kalman Filter was implemented for the identification of time-varying human manual control behavior. Two filters that run concurrently were used, a state filter that estimates the equalization dynamics, and a parameter filter that estimates the neuromuscular parameters and time delay. Time-varying parameters were modeled as a random walk. The filter successfully estimated time-varying human control behavior in both simulated and experimental data. Simple guidelines are proposed for the tuning of the process and measurement covariance matrices and the initial parameter estimates. The tuning was performed on simulation data, and when applied on experimental data, only an increase in measurement process noise power was required in order for the filter to converge and estimate all parameters. A sensitivity analysis to initial parameter estimates showed that the filter is more sensitive to poor initial choices of neuromuscular parameters than equalization parameters, and bad choices for initial parameters can result in divergence, slow convergence, or parameter estimates that do not have a real physical interpretation. The promising results when applied to experimental data, together with its simple tuning and low dimension of the state-space, make the use of the Dual Extended Kalman Filter a viable option for identifying time-varying human control parameters in manual tracking tasks, which could be used in real-time human state monitoring and adaptive human-vehicle haptic interfaces.

manual control↗

Photoacoustic Chemical Detector

A laser vibrometer for measurement of ambient chemical species includes a laser that produces a beam that is split into a reference readout beam and a signal readout beam. A probe laser beam is tuned to an absorption feature of a molecular transition, and generates acoustic signals when incident on a gaseous species via the photo acoustic effect. The scattered acoustic signals are incident on a thin membrane that vibrates. The readout laser beam reflected from the vibrating membrane is mixed with the reference beam at the surface of a photo-EMF detector. Interferrometric fringes are generated at the surface of the photo-EMF detector. Electric current is generated in the photo-EMF detector when the fringes are in motion due to undulations in the signal readout beam imparted by the vibrating membrane. A highly sensitive photo-EMF detector is capable of detecting picoJoules or less laser energy generated by vibrating processes.

Prasad, Narasimha S.↗

Further Development of an Electromagnetic Position Sensor for a Wind Tunnel MSBS

An Electromagnetic Position Sensor (EPS) was successfully developed in the 1960’s for the MIT “6-inch” Magnetic Suspension and Balance System. An updated version remains in use today, based on analog electronics. This paper will review the hardware revisions made to successfully adapt the system for use in sensing 3 degrees-of-freedom motion of small spherical or near-spherical suspended models. Practical challenges related to electrical noise sensitivity and stray coupling paths will be discussed. Preliminary analysis of alternative demodulation approaches, including digital signal processing, will be reviewed.

Britcher, Colin↗

Assembly of the IXPE Mirror Modules

Expected to launch in December 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Astrophysics Small Explorer Mission with significant contributions from the Italian space agency (ASI). Three identical x-ray telescopes combine to form the IXPE Observatory. Each is comprised of a 4-m-focal length mirror module assembly (MMA, provided by Marshall Space Flight Center) that focuses x-rays onto a polarization-sensitive, imaging detector (contributed by ASI-funded institutions). This paper describes the now-completed assembly process for the 3 flight and one spare mirror modules, and compares as-tested calibrated performance with as-built metrology data. Unexpected challenges and lessons-learned are also discussed.

X-ray optics IXPE polarimetry↗

Comparison of SAR and CYNSS surface water extent metrics over the Yucatan Lake wetland site

Wetlands have a major role in the carbon cycle, outgassing large quantities of carbon dioxide and methane through processes that are directly and strongly influenced by the duration and timing of inundation. Therefore, understanding the seasonal pattern of inundation can be a component for regional to global scale carbon models. Measurement of inundation extent also establishes a benchmark for the current status of wetland areas, useful in assessing the future impacts of climate change. The incorporation of frequent measurements of inundation extent into large-scale hydrological models would permit the evaluation of more detailed seasonal and longer-term floodplain dynamics and their associated management implications.The Cyclone GNSS (CYGNSS) constellation of satellites launched in 2016, and carries receivers capable of receiving data from L-band GNSS reflections. Delay Doppler maps (DDM) are generated on board and telemetered to the ground, along with a small number of raw data takes that can be used for special processing on the ground for evaluation purposes. It has been previously shown that these data can be sensitive to inundation.The NASA ISRO Synthetic Aperture Radar, currently planned for launch in January 2023, has both an L-band and S-band SAR for earth imaging. The L-band SAR, which will image the Earth's land mass twice every 12 days, has a requirement for measuring wetland inundation extent at the 1 ha scale. One of the sites that will be used to validate this requirement is Yucatan Lake, Louisiana. This oxbow lake and surrounding area located adjacent to the Mississippi river experiences periodic and extensive flooding in the surrounding forest areas.In 2019, NASA's UAVSAR fully polarimetric airborne L-band SAR conducted a flight campaign to image a dozen sites in the SE USA at approximately 12-day intervals and both in the morning and evening, to simulate the type of data NISAR will obtain. One site imaged during this campaign was the Yucatan Lake area, spanning water stages from low to high flood conditions.It has been demonstrated previously that GNSS reflectometry such as that measured by CYGNSS may be used to characterize surface inundation. It has also been known for decades that L-band SAR may be used to characterize not only the presence of open water, but also the presence of subcanopy inundation in forested areas. In this paper we will present results comparing data from these two types of instruments.

Lavalle, Marco↗

The Electrostatic Levitation Facility at NASA's Marshall Space Flight Center

Containerless processing is an important area of research in materials science. Electrostatic levitation (ESL) represents an emerging technology which permits containerless processing in a vacuum environment. NASA's Marshall Space Flight Center (MSFC) established a levitation facility to provide a critical resource to the microgravity materials science research community to continue and enhance ground-based research in the support of the development of flight experiments during the transition to Space Station. During ESL processing, charged specimens are levitated in the electrostatic field produced by the system's electrodes. Three sets of positioning electrodes represent the heart of the MSFC system. Two dual-axis position sensitive detectors provide input for the PID control-loop computer. Sample position is maintained by adjusting the control voltages for the power supplies of the positioning electrodes. A UV source refreshes the charge on specimens during processing via the photoelectric effect. Lasers permit sample heating independent of positioning. The processing chamber typically operates under vacuum condition approximately = 10(exp -7) Torr. Electrostatic levitation provides a materials science research tool for investigations of refractory solids and melts. Topics of investigation include thermophysical properties, phase equilibria, metastable phase formation, undercooling and nucleation, time-temperature-transformation diagrams and other aspects of materials processing. Current capabilities and recent results of processing studies for metals, alloys and oxides will be reviewed.

Rogers, Jan R.↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of the scaled model in the wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise, which is associated with the quantum processes both in the generation of the photons by the luminescent uPSP and in the conversion of the photons into electrons within the camera, is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed as an area-weighted average of the uPSP measured pressures on the grid nodes of a user-defined patch. The effect of the shot noise is reduced in the integrated pressure; however, the measurement of the aerodynamic pressure is also attenuated. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF is defined as the ratio of the auto or cross Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average auto PSD of the aerodynamic pressure on the grid nodes of the patch. Under the assumption that the cross spectrum of the aerodynamic pressure can be described with the Corcos model, the closed-form formula of the JAAF is derived for the integrated pressure on rectangular patches via the summation of uPSP measurements on discrete grid nodes. The closed-form formula is verified via the integration of the pressure field of Corcos model over continuous areas. The properties of the JAAF with different parameters are presented and the applications in the comparison of the spectrum of the pressure transducers and uPSP measurements, which were collected in the NASA Space Launch System (SLS) tests with the 11-by-11-foot transonic wind tunnel at NASA Ames Research Center in December 2017 and September 2019 respectively, are also discussed. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities(AETC) Portfolio Office.

Unsteady Pressure-Sensitive Paint↗

Diagnosis of Middle Atmosphere Climate Sensitivity by the Climate Feedback Response Analysis Method

We present a new method to diagnose the middle atmosphere climate sensitivity by extending the Climate Feedback-Response Analysis Method (CFRAM) for the coupled atmosphere-surface system to the middle atmosphere. The Middle atmosphere CFRAM (MCFRAM) is built on the atmospheric energy equation per unit mass with radiative heating and cooling rates as its major thermal energy sources. MCFRAM preserves the CFRAM unique feature of an additive property for which the sum of all partial temperature changes due to variations in external forcing and feedback processes equals the observed temperature change. In addition, MCFRAM establishes a physical relationship of radiative damping between the energy perturbations associated with various feedback processes and temperature perturbations associated with thermal responses. MCFRAM is applied to both measurements and model output fields to diagnose the middle atmosphere climate sensitivity. It is found that the largest component of the middle atmosphere temperature response to the 11-year solar cycle (solar maximum vs. solar minimum) is directly from the partial temperature change due to the variation of the input solar flux. Increasing CO2 always cools the middle atmosphere with time whereas partial temperature change due to O3 variation could be either positive or negative. The partial temperature changes due to different feedbacks show distinctly different spatial patterns. The thermally driven globally averaged partial temperature change due to all radiative processes is approximately equal to the observed temperature change, ranging from 0.5 K near 70 km from the near solar maximum to the solar minimum.

MCFRAM↗

Performance of High-Resolution Mo/Cu Transition Edge Sensors Fabricated Using a Lift-Off Process

The soft X-ray band below ≈0.5 keV is expected to provide rich information on metallicity, temperature, and distribution of hot gas in our galaxy and the intergalactic medium. Resolving these densely spaced emission lines requires energy resolution on the order of 1--2 eV. The low count rates from diffuse astrophysical sources also necessitate large collection areas, particularly for a sounding rocket instrument with short exposure times and limited resources. This translates to large pixel sizes (about 1 mm 2 ) for a reasonable number of read-out channels. To achieve the required energy resolution with 200 nm thin Au absorbers (heat capacity C about 1 pJ/K), we are developing TES microcalorimeters with very high temperature sensitivity (αI), low enough current sensitivity (βI), and minimal excess noise (M). Out of the various fabrication approaches for the TES bilayer we have explored, the lift-off approach (as pioneered for Mo/Au TES by Joel Weber at NIST) so far is the simplest to execute. The simple square TES geometries we have tested to date show promising results for αI and βI. Measured complex impedance and noise for bare devices without absorbers are well described by two-body thermal models and their excess noise is found to be consistent with predictions for mixed-down Johnson noise by Wessels et al. More sensitive measurements with larger heat capacity are planned to accurately determine excess noise. In this paper, we give an overview of the process and summarize results of our detailed characterization measurements for thermal conductance G, αI, βI, and noise for several devices across a range of bias points.

Felix T Jaeckel↗

Numerical studies of the thermal design sensitivity calculation for a reaction-diffusion system with discontinuous derivatives

The aim of this study is to find a reliable numerical algorithm to calculate thermal design sensitivities of a transient problem with discontinuous derivatives. The thermal system of interest is a transient heat conduction problem related to the curing process of a composite laminate. A logical function which can smoothly approximate the discontinuity is introduced to modify the system equation. Two commonly used methods, the adjoint variable method and the direct differentiation method, are then applied to find the design derivatives of the modified system. The comparisons of numerical results obtained by these two methods demonstrate that the direct differentiation method is a better choice to be used in calculating thermal design sensitivity.

Hou, Jean W.↗

X-ray sensitive oblique imaging device

Instrument employs light reflecting surface (evaporated aluminum coating or minor substrate) behind phosphor screen to improve effective quantum efficiency in dual process: fraction of incoming X-rays are converted to photoelectrons at photocathode; and X-rays that pass through photocathode and thin X-ray transparent membrane enter phosphor screen.

Hallam, K. L.↗

Processing of Signals from Fiber Bragg Gratings Using Unbalanced Interferometers

Fiber Bragg gratings (FBG) have become preferred sensory structures in fiber optic sensing system. High sensitivity, embedability, and multiplexing capabilities make FBGs superior to other sensor configurations. The main feature of FBGs is that they respond in the wavelength domain with the wavelength of the returned signal as the indicator of the measured parameter. The wavelength is then converted to optical intensity by a photodetector to detect corresponding changes in intensity. This wavelength-to-intensity conversion is a crucial part in any FBG-based sensing system. Among the various types of wavelength-to-intensity converters, unbalanced interferometers are especially attractive because of their small weight and volume, lack of moving parts, easy integration, and good stability. In this paper we investigate the applicability of unbalanced interferometers to analyze signals reflected from Bragg gratings. Analytical and experimental data are presented.

Adamovsky, Grigory↗

Uncertainty in Heart Rate Complexity Metrics Caused by R-Peak Perturbations

Heart rate complexity (HRC) is a proven metric for gaining insight into human stress and physiological deterioration. To calculate HRC, the detection of the exact instance of when the heart beats, the R-peak, is necessary. Electrocardiogram (ECG) signals can often be corrupted by environmental noise (e.g., from electromagnetic interference, movement artifacts), which can potentially alter the HRC measurement, producing erroneous inputs which feed into decision support models. Current literature has only investigated how HRC is affected by noise when R-peak detection errors occur (false positives and false negatives). However, the numerical methods used to calculate HRC are also sensitive to the specific location of the fiducial point of the R-peak. This raises many questions regarding how this fiducial point is altered by noise, the resulting impact on the measured HRC, and how we can account for noisy HRC measures as inputs into our decision models. This work uses Monte Carlo simulations to systematically add white and pink noise at different permutations of signal-to-noise ratios (SNRs), time segments, sampling rates, and HRC measurements to characterize the influence of noise on the HRC measure by altering the fiducial point of the R-peak. Using the generated information from these simulations provides improved decision processes for system design which address key concerns such as permutation entropy being a more precise, reliable, less biased, and more sensitive measurement for HRC than sample and approximate entropy.

Napoli, Nicholas J.↗

Preparation of large-particle-size monodisperse latexes in space - Polymerization kinetics and process development

Monodisperse polystyrene latexes are prepared by seeded emulsion polymerization; however, sizes larger than 2 microns are difficult to prepare because of the creaming and settling of the particles and their sensitivity to mechanical shear. Preparation in space would obviate the creaming and settling, and allow agitation just sufficient for good heat transfer and mixing. Three polymerizations yielding 3-5 micron size particles were carried out successfully on the third flight of the 'Columbia' launched Mar. 22, 1982; however, four polymerizations yielding sizes up to 10 microns on the fourth flight launched June 27, 1982 were incomplete owing to apparatus malfunction. The results of these polymerizations and the prospects of developing a preparative space process are reviewed.

Vanderhoff, J. W.↗