Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

SU-F-T-489: 4-Years Experience of QA in TomoTherapy MVCT: What Do We Look Out For?

Purpose: To evaluate the QA results of TomoTherapy MVCT from March 2012 to February 2016, and to identify issues that may affect consistency in HU numbers and reconstructed treatment dose in MVCT. Methods: Monthly QA was performed on our TomoHD system. Phantom with rod inserts of various mass densities was imaged in MVCT and compared to baseline to evaluate HU number consistency. To evaluate treatment dose reconstructed by delivered sinogram and MVCT, a treatment plan was designed on a humanoid skull phantom. The phantom was imaged with MVCT and treatment plan was delivered to obtain the sinogram. The dose reconstructed with the Planned Adaptive software was compared to the dose in the original plan. The QA tolerance for HU numbers was ±30 HU, and ±2% for discrepancy between original plan dose and reconstructed dose. Tolerances were referenced to AAPM TG148. Results: Several technical modifications or maintenance activities to the system have been identified which affected QA Results: 1) Upgrade in console system software which added a weekly HU calibration procedure; 2) Linac or MLC replacement leading to change in Accelerator Output Machine (AOM) parameters; 3) Upgrade in planning system algorithm affecting MVCT dose reconstruction. These events caused abrupt changes in QA results especially for the reconstructed dose. In the past 9 months, when no such modifications were done to the system, reconstructed dose was consistent with maximum deviation from baseline less than 0.6%. The HU number deviated less than 5HU. Conclusion: Routine QA is essential for MVCT, especially if the MVCT is used for daily dose reconstruction to monitor delivered dose to patients. Several technical events which may affect consistency of this are software changes, linac or MLC replacement. QA results reflected changes which justify re-calibration or system adjustment. In normal circumstances, the system should be relatively stable and quarterly QA may be sufficient.

60 APPLIED LIFE SCIENCES↗

Hydrodynamic and Radiographic Toolbox (HART)

With a multi-lab and university team, we propose to develop new methods for a Hydrodynamic and Radiographic Toolbox (HART) that will enable a fuller and more extensive use of experimental radiographic data towards better characterizing and reducing uncertainties in predictive modeling of weapons performance. We will achieve this by leveraging recent developments in areas of computational imaging, statistical and machine learning, and reduced order modeling of hydrodynamics. In terms of software practices, by partnering with XCP (RISTRA Project) we will conform to recent XCP standards that are inline with modern software practices and standards and ensure compatibility and ease of inter-operability with existing codes. Three new activities under this proposal include (a) the development and use of deep learning-based surrogates to accelerate reconstruction and variational inference of density fields from radiographs of hydrotests, (b) a model-data fusion strategy that couples deep learning-based density reconstructions with fast hydrodynamics simulators to better constrain the reconstruction, and (c) a method for treating asymmetries using techniques adopted from limited view tomography. All three new activities will be based on improved treatment of scatter, noise, beam spot movement, detector blur, and flat fielding in the forward model, and a use of sophisticated priors to aid in the re construction. The improvements to the forward model and improved algorithmic design of the reconstruction when complete will be contained in the iterative reconstruction code SHIVA—a code project that we have recently initiated. The many ways in which machine learning can be used in the reconstruction work will be contained in a code HERMES that has been initiated with DTRA support. For example, the significant levels of acceleration that will likely be achieved by the use of machine learning techniques will permit us (and are required) to quantify uncertainties in density retrievals. Next, the two-way coupling between density reconstruction and model-based simulation of the hydrodynamics will be contained in code EREBUS, and will permit a fuller realization of the potential of the data to constrain the hydrodynamic model and better address issues related to asymmetries in the problem. Finally, we anticipate that the better consistency with physics achieved in our reconstructions will allow them to be used by X-Division more so than today.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Nondestructive Evaluation of Concrete: Elastic Property Imaging Through Full-Waveform Inversion

Concrete is a vital material in construction—especially in the nuclear industry, where it is used in critical structures such as containment vessels. Over time, concrete can degrade due to harsh operational and environmental conditions, necessitating that its elastic properties be accurately evaluated to ensure structural integrity and safety. Traditional nondestructive evaluation methods such as ultrasound-based techniques often rely on simplifying assumptions that may not hold true for concrete. This paper presents an advanced ultrasound-based method that uses elastic full-waveform inversion (EFWI) to create detailed images of concrete’s mechanical properties. By accurately modeling wave behaviors such as scattering and reflection, we aim to overcome the limitations of conventional ultrasonic-based methods. In this work, the imaging problem involved reconstructing the various elastic properties of a heterogenous concrete block with three steel rebars embedded in it. The ultrasonic measurements were synthetically generated from multiple sources and receivers, and the reconstruction process was performed using a gradient-based optimization algorithm. Our approach leveraged EFWI to reconstruct high-resolution images of the pressure wave speed, shear wave speed, and density. Multiple misfit functions—including L2-norm, cross-correlation (CC), and L1-norm—combined with total variation (TV) regularization and parameter constraints using a Sigmoid function—were explored for the reconstruction. The results demonstrated that using the L1-norm misfit function in conjunction with TV regularization and Sigmoid constraints significantly improved the reconstruction quality in comparison to traditional methods. This approach provided clearer images with fewer artifacts and better captured background heterogeneity. Our findings highlight that, when properly designed, EFWI carries great potential for providing comprehensive, more accurate, and more reliable assessments of concrete conditions, as is crucial for the maintenance and safety of nuclear power plant structures.

97 - MATHEMATICS AND COMPUTING↗

A Pattern Recognition Algorithm for Quantum Annealers

Abstract The reconstruction of charged particles will be a key computing challenge for the high-luminosity Large Hadron Collider (HL-LHC) where increased data rates lead to a large increase in running time for current pattern recognition algorithms. An alternative approach explored here expresses pattern recognition as a quadratic unconstrained binary optimization (QUBO), which allows algorithms to be run on classical and quantum annealers. While the overall timing of the proposed approach and its scaling has still to be measured and studied, we demonstrate that, in terms of efficiency and purity, the same physics performance of the LHC tracking algorithms can be achieved. More research will be needed to achieve comparable performance in HL-LHC conditions, as increasing track density decreases the purity of the QUBO track segment classifier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charged particle tracking with quantum annealing optimization

Abstract At the High Luminosity Large Hadron Collider (HL-LHC), traditional track reconstruction techniques that are critical for physics analysis will need to be upgraded to scale with track density. Quantum annealing has shown promise in its ability to solve combinatorial optimization problems amidst an ongoing effort to establish evidence of a quantum speedup. As a step towards exploiting such potential speedup, we investigate a track reconstruction approach by adapting the existing geometric Denby-Peterson (Hopfield) network method to the quantum annealing framework for HL-LHC conditions. We develop additional techniques to embed the problem onto existing and near-term quantum annealing hardware. Results using simulated annealing and quantum annealing with the D-Wave 2X system on the TrackML open dataset are presented, demonstrating the successful application of a quantum annealing algorithm to the track reconstruction challenge. We find that combinatorial optimization problems can effectively reconstruct tracks, suggesting possible applications for fast hardware-specific implementations at the HL-LHC while leaving open the possibility of a quantum speedup for tracking.

97 MATHEMATICS AND COMPUTING↗

Phase Space Reconstruction from Accelerator Beam Measurements Using Neural Networks and Differentiable Simulations

Characterizing the phase space distribution of particle beams in accelerators is a central part of accelerator understanding and performance optimization. However, conventional reconstruction-based techniques either use simplifying assumptions or require specialized diagnostics to infer high-dimensional (> $2D$) beam properties. In this Letter, we introduce a general-purpose algorithm that combines neural networks with differentiable particle tracking to efficiently reconstruct high-dimensional phase space distributions without using specialized beam diagnostics or beam manipulations. Furthermore, we demonstrate that our algorithm accurately reconstructs detailed 4D phase space distributions with corresponding confidence intervals in both simulation and experiment using a single focusing quadrupole and diagnostic screen. This technique allows for the measurement of multiple correlated phase spaces simultaneously, which will enable simplified 6D phase space distribution reconstructions in the future.

47 OTHER INSTRUMENTATION↗

Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT - a preliminary study

This work is to demonstrate that high quality cone beam CT images can be generated for a volume of interest (VOI) and to investigate the exposure reduction effect, dose saving, and scatter reduction with the VOI scanning technique. The VOI scanning technique involves inserting a filtering mask between the x-ray source and the breast during image acquisition. The mask has an opening to allow full x-ray exposure to be delivered to a preselected VOI and a lower, filtered exposure to the region outside the VOI. To investigate the effects of increased noise due to reduced exposure outside the VOI on the reconstructed VOI image, we directly extracted the projection data inside the VOI from the full-field projection data and added additional data to the projection outside the VOI to simulate the relative noise increase due to reduced exposure. The nonuniform reference images were simulated in an identical manner to normalize the projection images and measure the x-ray attenuation factor for the object. Regular Feldkamp-Davis-Kress filtered backprojection algorithm was used to reconstruct the 3D images. The noise level inside the VOI was evaluated and compared with that of the full-field higher exposure image. Calcifications phantom and low contrast phantom were imaged. Dose reduction was investigated by estimating the dose distribution in a cylindrical water phantom using Monte Carlo simulation based Geant4 package. Scatter reduction at the detector input was also studied. Our results show that with the exposure level reduced by the VOI mask, the dose levels were significantly reduced both inside and outside the VOI without compromising the accuracy of image reconstruction, allowing for the VOI to be imaged with more clarity and helping to reduce the breast dose. The contrast-to-noise ratio inside the VOI was improved. The VOI images were not adversely affected by noisier projection data outside the VOI. Scatter intensities at the detector input were also shown to decrease significantly both inside and outside the VOI in the projection images, indicating potential improvement of image quality inside the VOI and contribution to dose reduction both inside and outside the VOI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A fast reconstruction method of the dense point-cloud model for cultural heritage artifacts based on compressed sensing and sparse auto-encoder

Since the point cloud data of cultural heritage artifacts obtained by the laser scanner is enormous and dense, these lead to a large quantity of network resource for storing, processing, and transmission. This paper provided a fast reconstruction method of the dense point cloud model for cultural relics based on sparse auto-encoder and compressed sensing. Firstly, the octree method based on the hash function was utilized to extract local features and remove redundant points. Secondly, the point cloud, which can be seen as the 3D geometric signal, is projected to the discrete Laplacian sparse basis via the point cloud adjacency matrix. Then, aiming at the bottleneck of slow recovery caused by tremendous scale of inverse problem based on compressed sensing theory, the sparse auto-encoder was applied to reduce the dimension and speed up the recovery. Finally, the OMP algorithm was applied to reconstruct 3D point cloud model based on the stochastic Gauss matrix. In order to test the performance of our methods, the 3D point cloud model of terracotta warriors and horses head were used. And the experimental results demonstrated that our approach can obviously accelerate the process of reconstruction of the dense point cloud model for the cultural heritage artifacts and ensure the recovery accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Description and Performance of Track and Primary-Vertex Reconstruction with the CMS Tracker

A description is provided of the software algorithms developed for the CMS tracker both for reconstructing charged-particle trajectories in proton-proton interactions and for using the resulting tracks to estimate the positions of the LHC luminous region and individual primary-interaction vertices. Despite the very hostile environment at the LHC, the performance obtained with these algorithms is found to be excellent. For tbar t events under typical 2011 pileup conditions, the average track-reconstruction efficiency for promptly-produced charged particles with transverse momenta of p(T) > 0.9GeV is 94% for pseudorapidities of |η| < 0.9 and 85% for 0.9 < |η| < 2.5. The inefficiency is caused mainly by hadrons that undergo nuclear interactions in the tracker material. For isolated muons, the corresponding efficiencies are essentially 100%. For isolated muons of p(T) = 100GeV emitted at |η| < 1.4, the resolutions are approximately 2.8% in p(T), and respectively, 10μm and 30μm in the transverse and longitudinal impact parameters. The position resolution achieved for reconstructed primary vertices that correspond to interesting pp collisions is 10–12μm in each of the three spatial dimensions. The tracking and vertexing software is fast and flexible, and easily adaptable to other functions, such as fast tracking for the trigger, or dedicated tracking for electrons that takes into account bremsstrahlung.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating End-to-End Deep Learning for Particle Reconstruction using CMS open data

Machine learning algorithms are gaining ground in high energy physics for applications in particle and event identification, physics analysis, detector reconstruction, simulation and trigger. Currently, most data-analysis tasks at LHC experiments benefit from the use of machine learning. Incorporating these computational tools in the experimental framework presents new challenges. This paper reports on the implementation of the end-to-end deep learning with the CMS software framework and the scaling of the end-to-end deep learning with multiple GPUs. The end-to-end deep learning technique combines deep learning algorithms and low-level detector representation for particle and event identification. We demonstrate the end-to-end implementation on a top quark benchmark and perform studies with various hardware architectures including single and multiple GPUs and Google TPU.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of Aluminum Plate Initial Residual Stress on Machined-Part Distortion

Dimensional tolerances for high-speed-machined aluminum products continue to tighten due to the demand for automated assembly of complex monolithic parts in aerospace and other industries. Understanding the contribution of inherent residual stress in wrought Al 7050-T7451 plate, common in aircraft manufacture, to distortion of high-aspect-ratio machined parts is critical but remains problematic due to the alloy's low residual stress magnitude over large geometries. Prior investigations into residual stress effects on machined part distortion suffer inadequate characterizations of the wrought material stress field, either because of low fidelity due to “slitting” methods, confounding effects in machined-layer removal methods, or small sample size when using neutron diffraction (ND). In this work, inherent residual stress is measured via ND at 860 locations in a 90.5 mm thick Al 7050-T7451 plate having dimensions 399 mm in the rolling direction and 335 mm in the transverse direction. Unlike prior studies, the ND residual stress is reconstructed using an iterative algorithm to ensure fully compatible, equilibrated 3D field prior to examining its effect on distortion. Further, the findings from simulations and experiments show that inherent residual stress alone could distort a high-aspect-ratio part beyond aerospace industry requirements, that slitting measurements may not sufficiently characterize residual stress for predicted distortion, and that parts machined from different plate thickness locations could exhibit reversed distortion patterns. Thus, research into distortion prediction that considers machining should carefully characterize and reconstruct inherent residual stress so that the coupled machining effects are accurately modeled.

36 MATERIALS SCIENCE↗

Demodulation of a single complex fringe interferogram with a path-independent regularized phase-tracking technique

The two-dimensional regularized phase-tracking (RPT) technique is one of the most powerful approaches to demodulate a single interferogram with either open or closed fringes. However, it often fails in the cases of complex interferograms and needs well-defined scanning strategies. An improved algorithm based on the RPT is presented in this paper. We use a paraboloid phase model to approximate the phase function and modify the cost functional to search the smoothest phase solutions in the function space C{sup 2}. With these modifications, the phase tracker preserves the robustness of the RPT while at the same time it is no more sensitive to stationary points and is capable of demodulating complex interferograms with arbitrary scanning schemes. Moreover, the phase reconstructed by the proposed algorithm is normally more accurate than that of the RPT both for noiseless and noisy interferograms under the same conditions. Computer simulations and experimental results are both presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Full Detector Simulation with Unprecedented Background Occupancy at a Muon Collider

In recent years, a Muon collider has attracted a lot of interest in the high-energy physics community, thanks to its ability of achieving clean interaction signatures at multi-TeV collision energies in the most cost-effective way. Estimation of the physics potential of such an experiment must take into account the impact of beam-induced background on the detector performance, which has to be carefully evaluated using full detector simulation. Tracing of all the background particles entering the detector region in a single bunch crossing is out of reach for any realistic computing facility due to the unprecedented number of such particles. To make it feasible a number of optimisations have been applied to the detector simulation workflow. This contribution presents an overview of the main characteristics of the beam-induced background at a Muon collider, the detector technologies considered for the experiment and how they are taken into account to strongly reduce the number of irrelevant computations performed during the detector simulation. Special attention is dedicated to the optimisation of track reconstruction with the conformal tracking algorithm in this high-occupancy environment, which is the most computationally demanding part of event reconstruction.

97 MATHEMATICS AND COMPUTING↗

Deep-Learning Electron Diffractive Imaging

Here, we report the development of deep-learning coherent electron diffractive imaging at subangstrom resolution using convolutional neural networks (CNNs) trained with only simulated data. We experimentally demonstrate this method by applying the trained CNNs to recover the phase images from electron diffraction patterns of twisted hexagonal boron nitride, monolayer graphene, and a gold nanoparticle with comparable quality to those reconstructed by a conventional ptychographic algorithm. Fourier ring correlation between the CNN and ptychographic images indicates the achievement of a resolution in the range of 0.70 and 0.55 Å. We further develop CNNs to recover the probe function from the experimental data. The ability to replace iterative algorithms with CNNs and perform real-time atomic imaging from coherent diffraction patterns is expected to find applications in the physical and biological sciences.

47 OTHER INSTRUMENTATION↗

The nanostructure problem

Diffraction techniques are making progress in tackling the difficult problem of solving the structures of nanoparticles and nanoscale materials. The great gift of x-ray crystallography has made us almost complacent in our ability to locate the three-dimensional coordinates of atoms in a crystal with a precision of around 10{sup -4} nm. However, the powerful methods of crystallography break down for structures in which order only extends over a few nanometers. In fact, as we near the one hundred year mark since the birth of crystallography, we face a resilient frontier in condensed matter physics: our inability to routinely and robustly determine the structure of complex nanostructured and amorphous materials. Knowing the structure and arrangement of atoms in a solid is so fundamental to understanding its properties that the topic routinely occupies the early chapters of every solid-state physics textbook. Yet what has become clear with the emergence of nanotechnology is that diffraction data alone may not be enough to uniquely solve the structure of nanomaterials. As part of a growing effort to incorporate the results of other techniques to constrain x-ray refinements - a method called 'complex modeling' which is a simple but elegant approach for combining information from spectroscopy with diffraction data to solve the structure of several amorphous and nanostructured materials. Crystallography just works, so we rarely question how and why this is so, yet understanding the physics of diffraction can be very helpful as we consider the nanostructure problem. The relationship between the electron density distribution in three dimensions (i.e., the crystal structure) and an x-ray diffraction pattern is well established: the measured intensity distribution in reciprocal space is the square of the Fourier transform of the autocorrelation function <{rho}(r){rho}(r+r')> of the electron density distribution {rho}(r). The fact that we get the autocorrelation function (rather than just the density distribution) by Fourier transforming the measured intensity leaves us with a very tricky inverse problem: we have to extract the density from its autocorrelation function. The direct problem of predicting the diffraction intensity given a particular density distribution is trivial, but the inverse, unraveling from the intensity distribution the density that gives rise to it, is a highly nontrivial problem in global optimization. In crystallography, this challenging, nontrivial task is sometimes referred to as the 'phase problem.' The diffraction pattern is a wave-interference pattern, but we measure only the intensities (the squares of the waves) not the wave amplitudes. To get the amplitude, you take the square root of the intensity I, but in so doing you lose any knowledge of the phase of the wave {phi}, and half the information needed to reconstruct the density is lost. When solving such inverse problems, you hope you can start with a uniqueness theorem that reassures you that, under ideal conditions, there is only one solution: one density distribution that corresponds to the measured intensity. Then you have to establish that your data set contains sufficient information to constrain that unique solution. This is a problem from information theory that originated with Reverend Thomas Bayes work in the 18th century, and the work of Nyquist and Shannon in the 20 th century, and describes the fact that the degrees of freedom in the model must not exceed the number of pieces of independent information in the data. Finally, you need an efficient algorithm for doing the reconstruction. This is exactly how crystallography works. The information is in the form of Bragg peak intensities and the degrees of freedom are the atomic coordinates. Crystal symmetry lets us confine the model to the contents of a unit cell, rather than all of the atoms in the crystal, keeping the degrees of freedom admirably small in number. A measurement yields a multitude of Bragg peak intensities, providing ample redundant intensity information to make up for the lost phases. Finally, there are highly efficient algorithms, such as 'direct methods,' that make excellent use of the available information and constraints to find the solution quickly from a horrendously large search space. The problem is often so overconstrained that we can cavalierly throw away lots of directional information. In particular, even though Bragg peaks are orientationally averaged to a 1D function in a powder diffraction measurement, we still can get a 3D structural solution. Now it becomes easy to understand the enormous challenge of solving nanostructures: the information content in the data is degraded while the complexity of the model is much greater.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-G-207-03: Mask Guided Image Reconstruction (MGIR): A Novel Method for Ultra-Low-Dose 3D and Enhanced 4D Cone-Beam Computer-Tomography

Purpose: Recently, compressed sensing (CS) based iterative reconstruction (IR) method is receiving attentions to reconstruct high quality cone beam computed tomography (CBCT) images using sparsely sampled or noisy projections. The aim of this study is to develop a novel baseline algorithm called Mask Guided Image Reconstruction (MGIR), which can provide superior image quality for both low-dose 3DCBCT and 4DCBCT under single mathematical framework. Methods: In MGIR, the unknown CBCT volume was mathematically modeled as a combination of two regions where anatomical structures are 1) within the priori-defined mask and 2) outside the mask. Then we update each part of images alternatively thorough solving minimization problems based on CS type IR. For low-dose 3DCBCT, the former region is defined as the anatomically complex region where it is focused to preserve edge information while latter region is defined as contrast uniform, and hence aggressively updated to remove noise/artifact. In 4DCBCT, the regions are separated as the common static part and moving part. Then, static volume and moving volumes were updated with global and phase sorted projection respectively, to optimize the image quality of both moving and static part simultaneously. Results: Examination of MGIR algorithm showed that high quality of both low-dose 3DCBCT and 4DCBCT images can be reconstructed without compromising the image resolution and imaging dose or scanning time respectively. For low-dose 3DCBCT, a clinical viable and high resolution head-and-neck image can be obtained while cutting the dose by 83%. In 4DCBCT, excellent quality 4DCBCT images could be reconstructed while requiring no more projection data and imaging dose than a typical clinical 3DCBCT scan. Conclusion: The results shown that the image quality of MGIR was superior compared to other published CS based IR algorithms for both 4DCBCT and low-dose 3DCBCT. This makes our MGIR algorithm potentially useful in various on-line clinical applications. Provisional Patent: UF#15476; WGS Ref. No. U1198.70067US00.

60 APPLIED LIFE SCIENCES↗

Measurement of inclusive and leading subjet fragmentation in pp and Pb–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

This article presents new measurements of the fragmentation properties of jets in both proton–proton (pp) and heavy-ion collisions with the ALICE experiment at the Large Hadron Collider (LHC). We report distributions of the fraction $z_r$ of transverse momentum carried by subjets of radius $r$ within jets of radius $R$. Charged-particle jets are reconstructed at midrapidity using the anti-$k_T$ algorithm with jet radius $R$ = 0.4, and subjets are reconstructed by reclustering the jet constituents using the anti-$k_T$ algorithm with radii $r$ = 0.1 and $r$ = 0.2. In proton–proton collisions, we measure both the inclusive and leading subjet distributions. We compare these measurements to perturbative calculations at next-to-leading logarithmic accuracy, which suggest a large impact of threshold resummation and hadronization effects on the $z_r$ distribution. In heavy-ion collisions, we measure the leading subjet distributions, which allow access to a region of harder jet frag- mentation than has been probed by previous measurements of jet quenching via hadron fragmentation distributions. The $z_r$ distributions enable extraction of the parton-to-subjet fragmentation function and allow for tests of the universality of jet fragmentation functions in the quark–gluon plasma (QGP). We find no significant modification of $z_r$ distributions in Pb–Pb compared to pp collisions. However, the distributions are also consistent with a hardening trend for $z_r$ < 0.95, as predicted by several jet quenching models. As $z_r$ → 1 our results indicate that any such hardening effects cease, exposing qualitatively new possibilities to disentangle competing jet quenching mechanisms. By comparing our results to theoretical calculations based on an independent extraction of the parton-to-jet fragmentation function, we find consistency with the universality of jet fragmentation and no indication of factorization breaking in the QGP.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗