Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sequential design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Heterogenous Acceleration for Linear Algebra in Multi-coprocessor Environments

We present an efficient and scalable programming model for the development of linear algebra in heterogeneous multi-coprocessor environments. The model incorporates some of the current best design and implementation practices for the heterogeneous acceleration of dense linear algebra (DLA). Examples are given as the basis for solving linear systems' algorithms - the LU, QR, and Cholesky factorizations. To generate the extreme level of parallelism needed for the efficient use of coprocessors, algorithms of interest are redesigned and then split into well-chosen computational tasks. The tasks execution is scheduled over the computational components of a hybrid system of multi-core CPUs and coprocessors using a light-weight runtime system. The use of lightweight runtime systems keeps scheduling overhead low, while enabling the expression of parallelism through otherwise sequential code. This simplifies the development efforts and allows the exploration of the unique strengths of the various hardware components.

Luszczek, Piotr R↗

Evolution of LIBS technology to mobile instrumentation for expediting firearm-related investigations at the laboratory and the crime scene

Gunshot residue (GSR) is one of the few forensic disciplines that lack accurate screening techniques. This study proposes using a mobile LIBS instrument to detect inorganic GSR and compares performance to a previously validated laboratory instrument. The mobile LIBS is designed with advanced configurations specifically for on-site GSR analysis, including a CMOS detector and a sampling chamber that holds up to six typical GSR collection devices with separate gas flow ports to prevent cross-contamination. A significant novelty of the portable instrument is its image magnification, which allows quick searching and visualization of GSR particle morphology. The single-particle imaging and elemental composition capability is one of a kind and offers superior confirmatory features for GSR. The mobile LIBS performance was evaluated for residues collected from the hands of shooters (100 samples) and non-shooters (200 background samples), analyzed sequentially by the mobile instrument and then the laboratory instrument. Accuracies better than 98.8% were obtained by both instruments, demonstrating their suitability for trace IGSR detection from skin specimens. Implementation of this methodology is anticipated to drastically speed up response times (i.e., from several hours per sample by standard SEM-EDS practice to a few minutes by LIBS). The screening methods can be easily incorporated into workflows to improve decision-making processes at the crime scene and laboratory settings, reduce backlogs, and improve case management.

47 OTHER INSTRUMENTATION↗

Development of Carbon Molecular Sieves Hollow Fiber Membranes based on Polybenzimidazole Doped with Polyprotic Acids with Superior H 2 /CO 2 Separation Properties (Final Report)

The goal of this project was to develop a highly efficient membrane-based process to capture CO 2 from coal-derived syngas with 95% CO 2 purity, achieving the cost of electricity (COE) 30% below the baseline capture approaches (i.e., Selexol process) when coupled with the advancement in other areas of the power generation facility. Our core approach is based on high-permeance hollow fiber membranes (HFMs) with superior H 2 /CO 2 separation properties at the syngas process conditions, which can then be further utilized to design membrane reactors for process intensification of H 2 production and purification and CO 2 capture. Three organizations with complementary skills collaborated to achieve the goal, including the University at Buffalo (UB), Los Alamos National Laboratory (LANL), and Trimeric Corporation (Trimeric). We formulated logical steps to bring the membrane technology from Technology Readiness Level (TRL) 3 (Experimental proof of concept) to TRL 4 (Laboratory scale validation in relevant environment). During the budget period (BP) 1, we screened various polymeric materials and identified polybenzimidazole doped with inorganic polyprotic acids as the desirable platform. The acid doping increases the H 2 /CO 2 selectivity, and the sequential carbonization increases H 2 permeability while retaining the high selectivity. By manipulating the acid type and doping level and the carbonization temperature, we demonstrated advanced carbon molecular sieving (CMS) materials with H 2 permeability of above 200 Barrer (1 Barrer = 10 -10 cm 3 (STP) cm cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of above 40 at 200-300°C with simulated syngas containing CO and water vapor. For example, the PBI-(H 3 PO 4 ) 0.11 carbonized at 700 °C exhibits H 2 permeability of 200 Barrer and H 2 /CO 2 selectivity of 60 at 200 °C, and H 2 permeability of 240 Barrer and H 2 /CO 2 selectivity of 54 at 225 °C, which meets the targeted properties and surpasses Robeson’s upper bound. During the BP2, we focused on the conversion of the advanced CMS materials to stable HFMs. Membranes with H 2 permeance of 1,090 GPU (1 GPU = 10 -6 cm 3 (STP) cm -2 s -2 cmHg -1 ) and H 2 /CO 2 selectivity of 57 at 300 °C were successfully fabricated. The effects of temperature, gas compositions, pressure, and time on the separation properties were systematically investigated. Pencil modules were continuously evaluated for 219 h (dry pure gas) and 669 h (dry simulated syngas) and showed initial decline in permeance and increased H 2 /CO 2 selectivity over time, ultimately achieving a steady state stable value, indicating that the ageing phenomena in the nanoporous structures of the membranes during the test. Membrane reactors were fabricated based on the CMS membranes and evaluated for water-gas shift (WGS) reaction. The use of membranes slightly improves the conversion of the CO. However, parametric tests of the membrane reactors at various temperatures and flow rates need to be conducted, as well as the membranes with improved separation performance. We performed a sensitivity analysis on the impact of H 2 /CO 2 selectivity on the COE based on a hybrid process of a membrane unit and cryogenic unit developed by Membrane Technology and Research, Inc. (MTR). Three H 2 /CO 2 selectivity (40, 60, and 15) cases were developed and compared with the baseline capture process (Case B5B) provided by the DOE report. Increasing the membrane H 2 /CO 2 selectivity reduces COE, but the rate of the decrease of COE also diminishes. The COE values for H 2 /CO 2 selectivities of 40 and 60 were nearly the same. As the H 2 /CO 2 selectivity increases, the inert recycling decreases, leading to smaller equipment, less auxiliary power requirements, and less heating, cooling, and refrigeration duty. The refrigeration system used to liquefy the CO 2 is the most expensive piece of equipment and consumes the most electricity within the CO 2 capture process. Increasing the CO 2 concentration in the recycle stream would improve the economics of the process by reducing the refrigeration duty requirement of the unit and also allow for higher liquefaction temperatures. The high H 2 -selective membrane developed by our team may be applicable in other separation processes where lower pressure H 2 retains value. Typically, hydrogen retains its pressure when it is separated from syngas components. Residual components may be used as low-quality fuel and then vented to the atmosphere. Applications might include control of H 2 /CO ratios or mitigation of the water gas shift reaction by CO 2 recycling to the feed of a gasifier or steam methane reformer. To summarize, we have developed industrial HFMs with the best H 2 /CO 2 separation performance reported in the literature. The membranes demonstrate stability with simulated syngas and show great potential for membrane reactors for WGS reactions, lowering the cost of blue H 2 production.

20 FOSSIL-FUELED POWER PLANTS↗

Comparative Evaluation of Different Optimization Algorithms for Structural Design Applications

Non-linear programming algorithms play an important role in structural design optimization. Fortunately, several algorithms with computer codes are available. At NASA Lewis Research Centre, a project was initiated to assess the performance of eight different optimizers through the development of a computer code CometBoards. This paper summarizes the conclusions of that research. CometBoards was employed to solve sets of small, medium and large structural problems, using the eight different optimizers on a Cray-YMP8E/8128 computer. The reliability and efficiency of the optimizers were determined from the performance of these problems. For small problems, the performance of most of the optimizers could be considered adequate. For large problems, however, three optimizers (two sequential quadratic programming routines, DNCONG of IMSL and SQP of IDESIGN, along with Sequential Unconstrained Minimizations Technique SUMT) outperformed others. At optimum, most optimizers captured an identical number of active displacement and frequency constraints but the number of active stress constraints differed among the optimizers. This discrepancy can be attributed to singularity conditions in the optimization and the alleviation of this discrepancy can improve the efficiency of optimizers.

Patnaik, Surya N.↗

Large-Scale Spacecraft Fire Safety Tests

An international collaborative program is underway to address open issues in spacecraft fire safety. Because of limited access to long-term low-gravity conditions and the small volume generally allotted for these experiments, there have been relatively few experiments that directly study spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample sizes and environment conditions typical of those expected in a spacecraft fire. The major constraint has been the size of the sample, with prior experiments limited to samples of the order of 10 cm in length and width or smaller. This lack of experimental data forces spacecraft designers to base their designs and safety precautions on 1-g understanding of flame spread, fire detection, and suppression. However, low-gravity combustion research has demonstrated substantial differences in flame behavior in low-gravity. This, combined with the differences caused by the confined spacecraft environment, necessitates practical scale spacecraft fire safety research to mitigate risks for future space missions. To address this issue, a large-scale spacecraft fire experiment is under development by NASA and an international team of investigators. This poster presents the objectives, status, and concept of this collaborative international project (Saffire). The project plan is to conduct fire safety experiments on three sequential flights of an unmanned ISS re-supply spacecraft (the Orbital Cygnus vehicle) after they have completed their delivery of cargo to the ISS and have begun their return journeys to earth. On two flights (Saffire-1 and Saffire-3), the experiment will consist of a flame spread test involving a meter-scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. On one of the flights (Saffire-2), 9 smaller (5 x 30 cm) samples will be tested to evaluate NASAs material flammability screening tests. The first flight (Saffire-1) is scheduled for July 2015 with the other two following at six-month intervals. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the first examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation.

Combustion↗

SU-C-9A-05: A Medical Physics Approach to the Evaluation of a New Anti-Reflux Catheter

Purpose: The Surefire Infusion System (SIS) is a coaxial microcatheter system with a pliant expanding tip designed to limit retrograde flow of administered intra-arterial embolic agents and resultant non-target embolization (NTE). A recent study suggests that the SIS may achieve relative arterial hypotension downstream to the catheter tip when compared to an end-hole catheter, potentially altering microsphere distribution. We have used a physics based approach to evaluate particulate distribution using both the SIS and standard end-hole microcatheter via a two-step same-day injection of Tc-99m MAA as a microsphere surrogate. Methods: Informed patient consent and IRB approval were obtained. Four patients with primary or secondary liver cancer underwent two sequential low-particulate infusions of Tc-99m MAA on the same day using both the SIS and a conventional end-hole catheter. Radiopharmaceutical dosages of approximately 1:8 were utilized in the first infusion relative to the second to eliminate the effect of residual activity on the images acquired after each step. SPECT imaging was obtained following each infusion, and MAA distribution was analyzed and compared. Archived fluoroscopic images confirmed near-identical catheter position for both infusions. Results: SPECT images from all four patients demonstrate qualitatively increased penetration of MAA distal to the site of infusion using the SIS when compared to a standard end-hole catheter. Quantitative evaluations corroborate these findings with some distal regions receiving between 33% to more than 200% greater relative activity when SIS was used. No appreciable NTE was identified in either patient subset. Conclusion: These preliminary data demonstrate the validity of this dual-infusion technique. Both qualitative and quantitative assessment of SPECT images and comparison with baseline contrast enhanced CT and PET/CT images indicate an improvement in MAA penetration into the target lesion with the SIS. However, the degree of improvement is highly dependent on tumor type and size. Financial support provided by Surefire Medical.

60 APPLIED LIFE SCIENCES↗

Fast-Acquisition/Weak-Signal-Tracking GPS Receiver for HEO

A report discusses the technical background and design of the Navigator Global Positioning System (GPS) receiver -- . a radiation-hardened receiver intended for use aboard spacecraft. Navigator is capable of weak signal acquisition and tracking as well as much faster acquisition of strong or weak signals with no a priori knowledge or external aiding. Weak-signal acquisition and tracking enables GPS use in high Earth orbits (HEO), and fast acquisition allows for the receiver to remain without power until needed in any orbit. Signal acquisition and signal tracking are, respectively, the processes of finding and demodulating a signal. Acquisition is the more computationally difficult process. Previous GPS receivers employ the method of sequentially searching the two-dimensional signal parameter space (code phase and Doppler). Navigator exploits properties of the Fourier transform in a massively parallel search for the GPS signal. This method results in far faster acquisition times [in the lab, 12 GPS satellites have been acquired with no a priori knowledge in a Low-Earth-Orbit (LEO) scenario in less than one second]. Modeling has shown that Navigator will be capable of acquiring signals down to 25 dB-Hz, appropriate for HEO missions. Navigator is built using the radiation-hardened ColdFire microprocessor and housing the most computationally intense functions in dedicated field-programmable gate arrays. The high performance of the algorithm and of the receiver as a whole are made possible by optimizing computational efficiency and carefully weighing tradeoffs among the sampling rate, data format, and data-path bit width.

Wintemitz, Luke↗

Kinetics of Nanoparticle Interactions in Battery Electrodes

Nanoparticles with a tendency to phase separate interact with each other during a process of either intraparticle phase separation (occurring inside the particle) or interparticle phase separation (occurring between particles). In this paper, we examine a halfcell consisting of two particles to systematically analyze the particle interactions and their resulting voltage response at different insertion currents. The kinetics of the interactions between nanoparticles is studied for cases in which particles undergo interparticle and intraparticle phase separation. Our results indicate that the interactions between particles in a cell containing only particles that undergo intraparticle phase separation are similar to those in a cell containing only particles that undergo interparticle phase separation. In both cases, sequential transformation occurs at low currents, whereas a simultaneous transformation occurs at high currents. Furthermore, such transformation dynamics changes in cases where the cell contains a mixture of particles that undergo interparticle and intraparticle phase separations, which exhibits more complex dynamics.

25 ENERGY STORAGE↗

An architecture for real-time vision processing

To study the feasibility of developing an architecture for real time vision processing, a task queue server and parallel algorithms for two vision operations were designed and implemented on an i860-based Mercury Computing System 860VS array processor. The proposed architecture treats each vision function as a task or set of tasks which may be recursively divided into subtasks and processed by multiple processors coordinated by a task queue server accessible by all processors. Each idle processor subsequently fetches a task and associated data from the task queue server for processing and posts the result to shared memory for later use. Load balancing can be carried out within the processing system without the requirement for a centralized controller. The author concludes that real time vision processing cannot be achieved without both sequential and parallel vision algorithms and a good parallel vision architecture.

Chien, Chiun-Hong↗

High-Throughput, Adaptive FFT Architecture for FPGA-Based Spaceborne Data Processors

Exponential growth in microelectronics technology such as field-programmable gate arrays (FPGAs) has enabled high-performance spaceborne instruments with increasing onboard data processing capabilities. As a commonly used digital signal processing (DSP) building block, fast Fourier transform (FFT) has been of great interest in onboard data processing applications, which needs to strike a reasonable balance between high-performance (throughput, block size, etc.) and low resource usage (power, silicon footprint, etc.). It is also desirable to be designed so that a single design can be reused and adapted into instruments with different requirements. The Multi-Pass Wide Kernel FFT (MPWK-FFT) architecture was developed, in which the high-throughput benefits of the parallel FFT structure and the low resource usage of Singleton s single butterfly method is exploited. The result is a wide-kernel, multipass, adaptive FFT architecture. The 32K-point MPWK-FFT architecture includes 32 radix-2 butterflies, 64 FIFOs to store the real inputs, 64 FIFOs to store the imaginary inputs, complex twiddle factor storage, and FIFO logic to route the outputs to the correct FIFO. The inputs are stored in sequential fashion into the FIFOs, and the outputs of each butterfly are sequentially written first into the even FIFO, then the odd FIFO. Because of the order of the outputs written into the FIFOs, the depth of the even FIFOs, which are 768 each, are 1.5 times larger than the odd FIFOs, which are 512 each. The total memory needed for data storage, assuming that each sample is 36 bits, is 2.95 Mbits. The twiddle factors are stored in internal ROM inside the FPGA for fast access time. The total memory size to store the twiddle factors is 589.9Kbits. This FFT structure combines the benefits of high throughput from the parallel FFT kernels and low resource usage from the multi-pass FFT kernels with desired adaptability. Space instrument missions that need onboard FFT capabilities such as the proposed DESDynl, SWOT (Surface Water Ocean Topography), and Europa sounding radar missions would greatly benefit from this technology with significant reductions in non-recurring cost and risk.

NguyenKobayashi, Kayla↗

Phosphor Thermometry Signal Analysis and Interpretation

Since the last International Temperature Symposium, phosphor thermometry has continued to mature with considerable attention given to combustion and turbine engine applications. More recently the utility to problems on the micro- and nano-scales has appreciated, particularly in regard to biological and biomedical situations. The method is therefore used for a wide range of situations. Signal interpretation is important and experience teaches that without sufficient care phosphor signals can be misleading. In order to advance the method, signal analysis investigations should prove fruitful. The specific aspect addressed here is the question of waveform sampling. A simple phenomenological approach is described that explores how the number of points digitized per waveform affects the measurement repeatability and accuracy. This is demonstrated for single shot signals and the average of 512 sequential waveforms. A bright temperature-independent luminescence signal from YVO4:Eu is sampled every 800 ps for a highly sampled condition and every 8 microseconds for a low sampled condition. When the average of 512 waveforms are compared for the two sampling conditions, they differ by only 0.4%. For the highly sampled case, a noisy single shot waveform compared to the averaged waveform differed by 1.8%. Future efforts on this subject will address intermediate and lower sampling rates. Also, variable window techniques should be explored that are especially important for non-log-linear signals. Investigations, such as this, give the developer the requisite information for designing analysis systems appropriate for the intended application in terms of precision, accuracy, and response time.

Fluorescence thermometry↗

A mulitple cathode gun design for the eRHIC polarized electron source

The future electron-ion collider eRHIC requires a high average current ({approx}50 mA), short bunch ({approx}3 mm), low emittance ({approx}20 {micro}m) polarized electron source. The maximum average current of a polarized electron source so far is more than 1 mA, but much less than 50 mA, from a GaAs:Cs cathode. One possible approach to overcome the average current limit and to achieve the required 50 mA beam for eRHIC, is to combine beamlets from multiple cathodes to one beam. In this paper, we present the feasibility studies of this technique. The future eRHIC project, next upgrade of RHIC, will be the first electron-heavy ion collider in the world. It requires polarized electron source with a high average current ({approx}50 mA), short bunch ({approx}3 mm), emittance of about 20 {micro}m and energy spread of {approx}1% at 10 MeV. The state-of-art polarized electron cathode can generate average current of about more than 1 mA, but much less than 50 mA. The current is limited by the low quantum efficiency, space charge and ultra-high vacuum requirement of the polarized cathode. A possible approach to achieve the 50 mA beam is to employ multiple cathodes, such as 20 cathodes, and funnel the multiple bunched beams from cathodes to the same axis. Fig.1 illustrates schematically the concept of combining the multiple beams. We name it as 'Gatling gun' because it bears functional similarity to a Gatling gun. Laser beams strike the cathodes sequentially with revolution frequency of 700 kHz. Each beam bunch is focused by a solenoid and is bent toward the combiner. The combiner with rotating bending field bends all bunches arriving the combiner with a rotational pattern to the same axis. The energy of each bunch is modified by a bunching cavity (112MHz) and a 3rd harmonic cavity (336MHz). The bunch length is compressed ballistically in the drift space and is frozen after energy has been boosted to 10 MeV by the Booster linac. Each beam bunch contains 3.5 nC charge. The space charge is very strong at energy of 200 keV. A long bunch, {sigma} of 250 ps, is adopted to reduce the space charge on cathode. To compress the beam to final length of 3 mm (10 ps) can be achieved by ballistic compression with a 3rd harmonic cavity.

43 PARTICLE ACCELERATORS↗

Adaptive scapula bone remodeling computational simulation: Relevance to regenerative medicine

Shoulder arthroplasty success has been attributed to many factors including, bone quality, soft tissue balancing, surgeon experience, and implant design. Improved long-term success is primarily limited by glenoid implant loosening. Prosthesis design examines materials and shape and determines whether the design should withstand a lifetime of use. Finite element (FE) analyses have been extensively used to study stresses and strains produced in implants and bone. However, these static analyses only measure a moment in time and not the adaptive response to the altered environment produced by the therapeutic intervention. Computational analyses that integrate remodeling rules predict how bone will respond over time. Recent work has shown that subject-specific two- and three dimensional adaptive bone remodeling models are feasible and valid. Feasibility and validation were achieved computationally, simulating bone remodeling using an intact human scapula, initially resetting the scapular bone material properties to be uniform, numerically simulating sequential loading, and comparing the bone remodeling simulation results to the actual scapula’s material properties. Three-dimensional scapula FE bone model was created using volumetric computed tomography images. Muscle and joint load and boundary conditions were applied based on values reported in the literature. Internal bone remodeling was based on element strain-energy density. Initially, all bone elements were assigned a homogeneous density. All loads were applied for 10 iterations. After every iteration, each bone element’s remodeling stimulus was compared to its corresponding reference stimulus and its material properties modified. The simulation achieved convergence. At the end of the simulation the predicted and actual specimen bone apparent density were plotted and compared. Location of high and low predicted bone density was comparable to the actual specimen. High predicted bone density was greater than actual specimen. Low predicted bone density was lower than actual specimen. Differences were probably due to applied muscle and joint reaction loads, boundary conditions, and values of constants used. Work is underway to study this. Nonetheless, the results demonstrate three dimensional bone remodeling simulation validity and potential. Such adaptive predictions take physiological bone remodeling simulations one step closer to reality. Computational analyses are needed that integrate biological remodeling rules and predict how bone will respond over time. We expect the combination of computational static stress analyses together with adaptive bone remodeling simulations to become effective tools for regenerative medicine research.

60 APPLIED LIFE SCIENCES↗

Cyclic debonding of adhesive joints

Bonded lap joints were manufactured and tested under static and fatigue loading. Specimens were designed to fail in the bondline, and all fatigue tests included monitoring the crack growth to failure. Test specimens included aluminum details joined by two different adhesives. Specimens also included titanium and boron-epoxy details joined by an epoxy laminating resin. Additonal program variables included bondline thickness, adherend and spice plate thickness, specimen width, and specimen fabrication procedure. Adhesive aging was found to be generally detrimental to the lives of most of the specimens bonded with one adhesive system. Adhesive material was found to have a major influence on debond rate. Co-cured titanium/boron-epoxy specimens were found to resist debonding better than specimens fabricated with a sequential cure. Splice plate thickness and test section width were found to have little effect on debond rate. The data also suggested the existence of an optimum bondline thickness.

Hoffman, D. J.↗

A high resolution soil moisture radiometer

The design of an L-band high resolution soil moisture radiometer is described. The selected system is a planar slotted waveguide array at L-band frequencies. The square aperture is 74.75 m by 74.75 m subdivided into 8 tilted subarrays. The system has a 290 km circular orbit and provides a spatial resolution of 1 km. The aperture forms 230 simultaneous beams in a cross-track pattern which covers a swath 420 km wide. A revisit time of 6 days is provided for an orbit inclination of 50 deg. The 1 km resolution cell allows an integration time of 1/7 second and sharing this time period sequentially between two orthogonal polarization modes can provide a temperature resolution of 0.7 K.

Dod, L. R.↗

Computer architecture for efficient algorithmic executions in real-time systems: New technology for avionics systems and advanced space vehicles

Improvements and advances in the development of computer architecture now provide innovative technology for the recasting of traditional sequential solutions into high-performance, low-cost, parallel system to increase system performance. Research conducted in development of specialized computer architecture for the algorithmic execution of an avionics system, guidance and control problem in real time is described. A comprehensive treatment of both the hardware and software structures of a customized computer which performs real-time computation of guidance commands with updated estimates of target motion and time-to-go is presented. An optimal, real-time allocation algorithm was developed which maps the algorithmic tasks onto the processing elements. This allocation is based on the critical path analysis. The final stage is the design and development of the hardware structures suitable for the efficient execution of the allocated task graph. The processing element is designed for rapid execution of the allocated tasks. Fault tolerance is a key feature of the overall architecture. Parallel numerical integration techniques, tasks definitions, and allocation algorithms are discussed. The parallel implementation is analytically verified and the experimental results are presented. The design of the data-driven computer architecture, customized for the execution of the particular algorithm, is discussed.

Carroll, Chester C.↗

Validation of Hygrothermal Simulations with Wall Performance Experiments in an Environmental Chamber

Oak Ridge National Laboratory is developing a web tool, built on a rule-based expert system, that aids stakeholders in designing energy-efficient moisture-durable walls. Currently, the tool’s expert system database is mostly populated with expert opinion, but work is being done to incorporate durability assessment based on stochastic hygrothermal modeling. Chamber experiments have been conducted to validate the hygrothermal models. The measured temperature and humidity have been compared with those predicted by the hygrothermal model. Experiments and comparison to one-dimensional hygrothermal modeling results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The two walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The walls were sequentially exposed to different scenarios, including diffusion, wetting, air leakage and solar radiation. For the most part, the hygrothermal simulations can be successfully used to predict the performance of these wall systems for the moisture transport phenomenon. Errors between measured and simulated values decreased as measurements got closer to the interior side of the wall. The root mean square error was larger for relative humidity (up to 17.5%-RH for CMU) than for temperature (up to 4.5°C for CMU wall). The errors were larger for the CMU wall than the wood frame wall. The phenomenon, including liquid water, caused large discrepancies between measurement and simulation results, and simulated results showed slower drying of materials than measured results. The one-dimensional nature of the simulation model made simulating air leaks difficult but not impossible.

Salonvaara, Mikael↗