Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrum Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Characterization of DESI fiber assignment incompleteness effect on 2-point clustering and mitigation methods for DR1 analysis

We present an in-depth analysis of the fiber assignment incompleteness in the Dark Energy Spectroscopic Instrument (DESI) Data Release 1 (DR1). This incompleteness is caused by the restricted mobility of the robotic fiber positioner in the DESI focal plane, which limits the number of galaxies that can be observed at the same time, especially at small angular separations. As a result, the observed clustering amplitude is suppressed in a scale-dependent manner, which, if not addressed, can severely impact the inference of cosmological parameters. We discuss the methods adopted for simulating fiber assignment on mocks and data. In particular, we introduce the fast fiber assignment (FFA) emulator, which was employed to obtain the power spectrum covariance adopted for the DR1 full-shape analysis. We present the mitigation techniques, organised in two classes: measurement stage and model stage. We then use high fidelity mocks as a reference to quantify both the accuracy of the FFA emulator and the effectiveness of the different measurement-stage mitigation techniques. This complements the studies conducted in a parallel paper for the model-stage techniques, namely the θ-cut approach. We find that pairwise inverse probability (PIP) weights with angular upweighting recover the “true” clustering in all the cases considered, in both Fourier and configuration space. Notably, we present the first ever power spectrum measurement with PIP weights from real data.

cosmological simulations↗

Theory for time-resolved resonant inelastic x-ray scattering

Time-resolved measurements of materials provide a wealth of information on quasiparticle dynamics, and have been the focus of optical studies for decades. In this paper, we develop a theory for explicitly evaluating time-resolved resonant inelastic x-ray scattering (tr-RIXS). We apply the theory to a noninteracting electronic system and reveal the particle-hole spectrum and its evolution during the pump pulse. With a high-frequency pump, the frequency and amplitude dependence analysis of the spectra agrees well with the steady-state assumptions and Floquet excitations. When the pump frequency is low, the spectrum extracts real-time dynamics of the particle-hole continuum in momentum space. These results verify the correctness of our theory and demonstrate the breadth of physical problems that tr-RIXS could shed light on.

36 MATERIALS SCIENCE↗

Delving into the depths of NGC 3783 with XRISM

We present our study of the X-Ray Imaging and Spectroscopy Mission (XRISM) observation of the Seyfert-1 galaxy NGC 3783. XRISM’s Resolve microcalorimeter has enabled, for the first time, a detailed characterization of the highly ionized outflows in this active galactic nucleus. Our analysis constrains their outflow and turbulent velocities, along with their ionization parameter (ξ) and column density (N H ). The high-resolution Resolve spectrum reveals a distinct series of Fe absorption lines between 6.4 and 7.8 keV, ranging from Fe XVIII to Fe XXVI. At lower energies (1.8−3.3 keV), absorption features from Si, S, and Ar are also detected. Our spectroscopy and photoionization modeling of the time-averaged Resolve spectrum uncovers six outflow components, five of which exhibit relatively narrow absorption lines with outflow velocities ranging from 560 to 1170 km s −1 . In addition, a broad absorption feature is detected, which is consistent with Fe XXVI outflowing at 14 300 km s −1 (0.05 c). The kinetic luminosity of this component is 0.8−3% of the bolometric luminosity. Our analysis of the Resolve spectrum shows that more highly ionized absorption lines are intrinsically broader than those of lower-ionization species, indicating that the turbulent velocity of the six outflow components (ranging from 0 to 3500 km s −1 ) increases with ξ. Furthermore, we find that the column density (N H ) of the outflows generally declines with the ionization parameter up to log ξ = 3.2 but rises beyond this point, suggesting a complex ionization structure. The absorption profile of the Fe XXV resonance line is intriguingly similar to UV absorption lines (Lyα and C IV) observed by the Hubble Space Telescope, from which we infer that the outflows are clumpy in nature. Our XRISM/Resolve results from lower- and higher-ionization regimes support a “hybrid wind” scenario in which the observed outflows have multiple origins and driving mechanisms. We explore various interpretations of our findings within active galactic nucleus wind models.

X-rays: galaxies↗

Fuel Cycle Research & Development: Technical Monthly – June 2012

Topics are: (1) MPACT Campaign - (a) Management and Integration • Coordination meetings between NE and NA-22, NA-24, and NA-82 were conducted the week of June 11th. Preparations are being made for the next MPACT working group meeting, scheduled for Aug 28-30 at Idaho Falls. In addition to covering accomplishments and discussing future plans, a site tour of INL facilities (MFC, EBR, ATR, INTEC) is being organized. (2) Accounting and Control Technologies - (a) Microcalorimetry • Now operating 256-pixel array at LANL. We are in the process of tuning detector parameters to improve and optimize performance. Preliminary measurements show approximate number of live pixels is similar to that observed previously at NIST. Continuing to study contribution to systematic error from uncertainties in tabulated gamma-ray energies. (b) Electrochemical Sensor • Testing of sensors fashioned from different precursor materials continued. SEM analysis of all used sensors has been or will be performed. (c) Lead Slowing Down Spectrometer • Ongoing perturbation calculations are providing information on the fundamental systematic error limits of LSDS. In order to achieve separating the contribution of Pu and 235U to the signal, there will need to be tight controls on systematic errors. Continuing to look into a He4 detector. Research into local construction of a He4 detector continued. We have started to apply the algorithm to test the LSDS using experimental data from previous RPI measurements. PNNL also developed a plan to address the lack of statistics in the MCNP modeling of the NGSI 64 assemblies. The ISU graduate student built and tested a fission chamber to gain experience with them. (d) Fast Neutron Imaging to Quantify Nuclear Materials • The imaging detector design was modified for each pixel to have an 8 x 8 pixel array. Quotations and purchasing process for components, including the new PSD scintillator are in progress. (e) Fast Neutron Multiplicity Analysis • The team submitted two papers to the upcoming INMM meeting that are related to the fast neutron multiplicity R&D effort. Progress was made on the project's main goal of designing a concept for a prototype fast-neutron multiplicity counter. We started laying out the outline for the final report. We have been working with our ORNL collaborators to develop a new digitizer system to support our experimental campaign planned for next year. (3) MPACT Analysis Tools - (a) Multi-isotope Process Monitor • Fuel characterization framework development continued during June. A report describing the methodologies is being completed. Kenneth Dayman, from University of Texas, spent a week at PNNL wrapping up his master's research and working on a journal submission covering that work. The target journal is the IEEE transactions on Nuclear Science; submission is planned for the end of July. A proposal to instrument H-Canyon is being prepared in conjunction with SRNL and the NNSA's NGSI program. The impact of gamma-ray spectrum counting statistics on the precision of relative radioisotope component intensities as reconstructed via Principal Component Regression (PCR) continued in June with Monte Carlo simulations of a two-component (i.e., two radioisotope) system. This work generalizes earlier studies in FY12 in which Poisson counting variations of only a single spectrum component were simulated. (b) Modeling and Simulation for Analysis of Safeguards Performance (Electrochemical) • Preliminary insights into safeguards challenges and the initial design for an electrochemical plant have been written up into an INMM paper and will be presented at the INMM Summer Meeting. Work is currently adding a new visualization capability for integrating materials accountancy with physical protection. (c) Material Control including Process Monitoring (Pattern Recognition, Sensors) • Fabrication of quartz chips continued at an external foundry. Awaiting delivery of the heat exchange manifold and chip holder. (d) MPACT System Integration and Technical Support • The initial report on cost-basis metrics for nuclear material security risk and proliferation risk was completed as scheduled. (4) Safeguards and Security by Design - (a) Used fuels storage security analysis, guidance and best practices • RFP was finalized and sent out. Awaiting response from World Institute for Nuclear Security. Coordinated with Scott Demuth on joint report • LANL milestone on best practices. Attended Nuclear Energy Institute National Nuclear Security Conference. Developed plan for soliciting input on prioritized issues for used fuel storage security. Worked on setting up a meeting with the Nuclear Regulatory Commission. Worked on FY2013 work package planning.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Image Analysis for Rapid Assessment and Quality-Based Sorting of Corn Stover

Imaging in the visible spectrum is a low-cost tool that can be readily deployed for in-field or over-belt monitoring of biomass quality for bio-refining operations. Rapid image analysis coupled with innovative preprocessing may reduce the impacts of feedstock variability through identification of contaminants or other material attributes to guide selective sorting and quality management. Image analysis was employed to evaluate the quality of corn stover in red-green-blue (RGB) chromatic space. This study used controlled, bench-scale imaging as a proof-of-concept for rapid quality assessment of corn stover based on variations in material attributes, including chemical and physical attributes, that relate to biological degradation and soil contamination. Additionally, logistic regression-based classification algorithms were used to develop a method for biomass screening as a function of biological degradation or soil contamination. This study demonstrated the use of image analysis to extract features from RGB color space to investigate variations in critical material attributes from chemical composition of corn stover. Fourier transform infrared (FT-IR) suggested a correlation between red band intensity and biological degradation, while detailed surface texture analysis was found to distinguish among variations in ash. These insights offer promise for development of a rapid screening tool that could be deployed by farmers for in-field assessment of biomass quality or biorefinery operators for in-line sorting and process optimization.

09 BIOMASS FUELS↗

SPECTRAL POLARIZATION OF THE REDSHIFTED 21 cm ABSORPTION LINE TOWARD 3C 286

A reanalysis of the Stokes-parameter spectra obtained of the z = 0.692 21 cm absorption line toward 3C 286 shows that our original claimed detection of Zeeman splitting by a line-of-sight magnetic field, B{sub los} = 87 {mu}G, is incorrect. Because of an insidious software error, what we reported as Stokes V is actually Stokes U: the revised Stokes V spectrum indicates a 3{sigma} upper limit of B{sub los}< 17 {mu}G. The correct analysis reveals an absorption feature in fractional polarization that is offset in velocity from the Stokes I spectrum by -1.9 km s{sup -1}. The polarization position-angle spectrum shows a dip that is also significantly offset from the Stokes I feature, but at a velocity that differs slightly from the absorption feature in fractional polarization. We model the absorption feature with three velocity components against the core-jet structure of 3C 286. Our {chi}{sup 2} minimization fitting results in components with differing (1) ratios of H I column density to spin temperature, (2) velocity centroids, and (3) velocity dispersions. The change in polarization position angle with frequency implies incomplete coverage of the background jet source by the absorber. It also implies a spatial variation of the polarization position angle across the jet source, which is observed at frequencies higher than the 839.4 MHz absorption frequency. The multi-component structure of the gas is best understood in terms of components with spatial scales of {approx}100 pc comprised of hundreds of low-temperature (T {<=} 200 K) clouds with linear dimensions of <<100 pc. We conclude that previous attempts to model the foreground gas with a single uniform cloud are incorrect.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of artificial neural network to prompt gamma neutron activation analysis for chemical warfare agents identification

The Portable Isotopic Neutron Spectroscopy (PINS) is a commercialized system developed by Idaho National Laboratory (INL) to examine chemical warfare agents (CWA) non-destructively, utilizing Prompt Gamma Neutron Activation Analysis (PGNAA) techniques. The PINS system takes advantage of a high-resolution gamma-ray spectrum from a mechanically-cooled high-purity germanium (HPGe) detector, and gamma-ray peak analysis provides input to its chemical identification logic with a probabilistic decision tree (PDT). The effectiveness of the chemical identification algorithm is determined by the availability of a wide range of data to train the algorithm to identify chemical-fills with accuracy. INL has a collection of gamma-ray spectra of various chemical-fills from the field-deployed PINS systems over the years, and it was envisaged to leverage such a database with the Artificial Neural Network (ANN) technique. Therefore, an ANN-based chemical identification algorithm was developed as an independent verification of the current algorithm. The ANN-based algorithm’s performance was evaluated against the U.S. Army blind test data, and results were presented and discussed in this study.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cascaded systems analysis of photon counting detectors

Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. Conclusions: The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.

60 APPLIED LIFE SCIENCES↗

CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions

Purpose: To measure radiation absorbed dose and its distribution in an anthropomorphic head phantom under clinically representative scan conditions in three widely used computed tomography (CT) scanners, and to relate those dose values to metrics such as high-contrast resolution, noise, and contrast-to-noise ratio (CNR) in the American College of Radiology CT accreditation phantom.Methods: By inserting optically stimulated luminescence dosimeters (OSLDs) in the head of an anthropomorphic phantom specially developed for CT dosimetry (University of Florida, Gainesville), we measured dose with three commonly used scanners (GE Discovery CT750 HD, Siemens Definition, Philips Brilliance 64) at two different clinical sites (Walter Reed National Military Medical Center, National Institutes of Health). The scanners were set to operate with the same data-acquisition and image-reconstruction protocols as used clinically for typical head scans, respective of the practices of each facility for each scanner. We also analyzed images of the ACR CT accreditation phantom with the corresponding protocols. While the Siemens Definition and the Philips Brilliance protocols utilized only conventional, filtered back-projection (FBP) image-reconstruction methods, the GE Discovery also employed its particular version of an adaptive statistical iterative reconstruction (ASIR) algorithm that can be blended in desired proportions with the FBP algorithm. We did an objective image-metrics analysis evaluating the modulation transfer function (MTF), noise power spectrum (NPS), and CNR for images reconstructed with FBP. For images reconstructed with ASIR, we only analyzed the CNR, since MTF and NPS results are expected to depend on the object for iterative reconstruction algorithms.Results: The OSLD measurements showed that the Siemens Definition and the Philips Brilliance scanners (located at two different clinical facilities) yield average absorbed doses in tissue of 42.6 and 43.1 mGy, respectively. The GE Discovery delivers about the same amount of dose (43.7 mGy) when run under similar operating and image-reconstruction conditions, i.e., without tube current modulation and ASIR. The image-metrics analysis likewise showed that the MTF, NPS, and CNR associated with the reconstructed images are mutually comparable when the three scanners are run with similar settings, and differences can be attributed to different edge-enhancement properties of the applied reconstruction filters. Moreover, when the GE scanner was operated with the facility's scanner settings for routine head exams, which apply 50% ASIR and use only approximately half of the 100%-FBP dose, the CNR of the images showed no significant change. Even though the CNR alone is not sufficient to characterize the image quality and justify any dose reduction claims, it can be useful as a constancy test metric.Conclusions: This work presents a straightforward method to connect direct measurements of CT dose with objective image metrics such as high-contrast resolution, noise, and CNR. It demonstrates that OSLD measurements in an anthropomorphic head phantom allow a realistic and locally precise estimation of magnitude and spatial distribution of dose in tissue delivered during a typical CT head scan. Additional objective analysis of the images of the ACR accreditation phantom can be used to relate the measured doses to high contrast resolution, noise, and CNR.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modeling the Echelle Spectra Continuum with Alpha Shapes and Local Regression Fitting

Continuum normalization of echelle spectra is an important data analysis step that is difficult to automate. Polynomial fitting requires a reasonably high-order model to follow the steep slope of the blaze function. However, in the presence of deep spectral lines, a high-order polynomial fit can result in ripples in the normalized continuum that increase errors in spectral analysis. Here, we present two algorithms for flattening the spectrum continuum. The Alpha-shape Fitting to Spectrum algorithm is completely data driven, using an alpha shape to obtain an initial estimate of the blaze function. The Alpha-shape and Lab Source Fitting to Spectrum algorithm incorporates a continuum constraint from a laboratory source reference spectrum for the blaze function estimation. These algorithms are tested on a simulated spectrum, where we demonstrate improved normalization compared to polynomial regression for continuum fitting. We show an additional application, using the algorithms for mitigation of spatially correlated quantum efficiency variations and fringing in the charge-coupled device detector of the EXtreme PREcision Spectrometer.

79 ASTRONOMY AND ASTROPHYSICS↗

Fermi large area telescope detection of a break in the gamma-ray spectrum of the supernova remnant Cassiopeia A

We report on observations of the supernova remnant Cassiopeia A in the energy range from 100 MeV to 100 GeV using 44 months of observations from the Large Area Telescope on board the Fermi Gamma-Ray Space Telescope. We perform a detailed spectral analysis of this source and report on a low-energy break in the spectrum at 1.72{sub −0.89}{sup +1.35} GeV. By comparing the results with models for the gamma-ray emission, we find that hadronic emission is preferred for the GeV energy range.

79 ASTRONOMY AND ASTROPHYSICS↗

SEARCHING FOR FAR-ULTRAVIOLET AURORAL/DAYGLOW EMISSION FROM HD 209458b

We present recent observations from the Hubble Space Telescope-Cosmic Origins Spectrograph aimed at characterizing the auroral emission from the extrasolar planet HD 209458b. We obtained medium-resolution (R {approx} 20,000) far-ultraviolet (1150-1700 A) spectra at both the Phase 0.25 and Phase 0.75 quadrature positions as well as a stellar baseline measurement at secondary eclipse. This analysis includes a catalog of stellar emission lines and a star-subtracted spectrum of the planet. We present an emission model for planetary H{sub 2} emission, and compare this model to the planetary spectrum. No unambiguously identifiable atomic or molecular features are detected, and upper limits are presented for auroral/dayglow line strengths. An orbital velocity cross-correlation analysis finds a statistically significant (3.8sigma) feature at +15(+- 20) km s{sup -1} in the rest frame of the planet, at lambda1582 A. This feature is consistent with emission from H{sub 2} B-X (2-9) P(4) (lambda{sub rest} = 1581.11 A); however, the physical mechanism required to excite this transition is unclear. We compare limits on relative line strengths seen in the exoplanet spectrum with models of ultraviolet fluorescence to constrain the atmospheric column density of neutral hydrogen between the star and the planetary surface. These results support models of short-period extrasolar giant planets with weak magnetic fields and extended atomic atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

CMB anisotropy power spectrum using linear combinations of WMAP maps

In recent years the goal of estimating different cosmological parameters precisely has set new challenges in the effort to accurately measure the angular power spectrum of the CMB. This has required removal of foreground contamination as well as detector noise bias with reliability and precision. Recently, a novel, model-independent method for the estimation of the CMB angular power spectrum solely from multifrequency observations has been proposed and implemented on the first year WMAP data by Saha et al. 2006. All previous estimates of the power spectrum of the CMB are based upon foreground templates using data sets from different experiments. However, our methodology demonstrates that the CMB angular spectrum can be reliably estimated with precision from a self-contained analysis of the WMAP data. In this work we provide a detailed description of this method. We also study and identify the biases present in our power spectrum estimate. We apply our methodology to extract the power spectrum from the WMAP data.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy spectrum and transport in narrow HgTe quantum wells

The results of an experimental study of the transport phenomena and the hole energy spectrum of two-dimensional systems in the quantum well of HgTe zero-gap semiconductor with normal arrangement of quantum-confinement subbands are presented. An analysis of the experimental data allows us to reconstruct the carrier energy spectrum near the hole subband extrema. The results are interpreted using the standard kP model.

36 MATERIALS SCIENCE↗

An Analysis of Muon Neutrino Disappearance from the NuMI Beam Using an Optimal Track Fitter

The NOvA experiment is a long-baseline neutrino oscillation experiment based out of Fermilab National Accelerator Laboratory that uses two liquid scintillator detectors, one at Fermilab (the \near" detector) and a second 14 kton detector in northern Minnesota (the \far" detector.) The primary physics goals of the NOvA experiment are to measure neutrino mixing parameters through both the v μ disappearance and v e appearance channels using neutrinos from the newly upgraded NuMI beam line. The NOvA v μ disappearance analysis can significantly improve the world's best measurement of sin 2 θ 23 . This analysis proceeds by using the measured v μ charged-current energy spectrum in the near detector to predict the spectrum in the far detector, and comparing this to the measured spectrum to obtain a best fit for the oscillation parameters sin 2 θ 23 and Δm 2 32 . Since this fit is governed by the shape of the energy spectrum, the best fit will be maximized by obtaining the best possible energy resolution for the individual neutrino events. This dissertation describes an alternate v μ disappearance analysis technique for the NOvA experiment, based on the idea that estimating the energy resolution of the individual events will allow them to be separated into different energy resolution samples in order to improve the final fit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of states in {sup 13}C populated in {sup 9}Be + {sup 4}He resonant scattering

Measurements of {sup 9}Be + {alpha} resonant scattering have been performed using the thick-target approach with a {sup 4}He gas volume and a large-area silicon strip detector. {sup 9}Be beam energies in the range 12 to 21.4 MeV were used to measure the {sup 13}C excitation energy spectrum between 13.2 and 16.2 MeV. An R-matrix analysis has been performed to characterize the spins and widths of {sup 13}C resonances, some of which have been proposed to be associated with a 3{alpha}+n molecular band.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intense radiative heat transport across a nano-scale gap

In this paper, we analyze the radiative heat transport in layered structures. The analysis is based on our prior description of the spectrum of thermally excited waves in systems with a heat flux. The developed method correctly predicts results for all known special cases for both large and closing gaps. Numerical examples demonstrate the applicability of our approach to the calculation of the radiative heat transport coefficient across various layered structures.

42 ENGINEERING↗

Quantization effects in radiation spectroscopy based on digital pulse processing

Radiation spectra represent inherently quantization data in the form of stacked channels of equal width. The spectrum is an experimental measurement of the discrete probability density function (PDF) of the detector pulse heights. The quantization granularity of the spectra depends on the total number of channels covering the full range of pulse heights. In analog pulse processing the total number of channels is equal to the total digital values produced by a spectroscopy analog-to-digital converter (ADC). In digital pulse processing each detector pulse is sampled and quantized by a fast ADC producing certain number of quantized numerical values. These digital values are linearly processed to obtain a digital quantity representing the peak of the digitally shaped pulse. Using digital pulse processing it is possible to acquire a spectrum with the total number of channels greater than the number of ADC values. Noise and sample averaging are important in the transformation of ADC quantized data into spectral quantized data. Analysis of this transformation is performed using an area sampling model of quantization. Spectrum differential nonlinearity (DNL) is shown to be related to the quantization at low noise levels and small number of averaged samples. Theoretical analysis and experimental measurements are used to obtain the condition to minimize the DNL due to quantization. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗