Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard deviation modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Inclusive search for a highly boosted Higgs boson decaying to a bottom quark-antiquark pair

An inclusive search for the standard model Higgs boson (H) produced with large transverse momentum (pT) and decaying to a bottom quark-antiquark pair (bb¯) is performed using a data set of pp collisions at s=13 TeV collected with the CMS experiment at the LHC. The data sample corresponds to an integrated luminosity of 35.9 fb-1. A highly Lorentz-boosted Higgs boson decaying to bb¯ is reconstructed as a single, large radius jet, and it is identified using jet substructure and dedicated b tagging techniques. The method is validated with Z→bb¯ decays. The Z→bb¯ process is observed for the first time in the single-jet topology with a local significance of 5.1 standard deviations (5.8 expected). For a Higgs boson mass of 125 GeV, an excess of events above the expected background is observed (expected) with a local significance of 1.5 (0.7) standard deviations. The measured cross section times branching fraction for production via gluon fusion of H→bb¯ with reconstructed pT>450 GeV and in the pseudorapidity range -2.5<η<2.5 is 74±48(stat)-10+17(syst) fb, which is consistent within uncertainties with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Standard Model Higgs Searches at the Tevatron

We present results from the search for a standard model Higgs boson using data corresponding up to 10 fb{sup -1} of proton-antiproton collision data produced by the Fermilab Tevatron at a center-of-mass energy of 1.96 TeV. The data were recorded by the CDF and D0 detectors between March 2001 and September of 2011. A broad excess is observed between 105 < m{sub H} < 145 GeV/c{sup 2} with a global significance of 2.2 standard deviations relative to the background-only hypothesis.

43 PARTICLE ACCELERATORS↗

A versatile machine learning workflow for high-throughput analysis of supported metal catalyst particles

Accurate and efficient characterization of nanoparticles (NPs), particularly regarding particle size distribution, is essential for advancing our understanding of their structure-property relationship and facilitating their design for various applications. In this study, we introduce a novel two-stage artificial intelligence (AI)-driven workflow for NP analysis that leverages prompt engineering techniques from state-of-the-art single-stage object detection and large-scale vision transformer (ViT) architectures. This methodology is applied to transmission electron microscopy (TEM) and scanning TEM (STEM) images of heterogeneous catalysts, enabling high-resolution, high-throughput analysis of particle size distributions for supported metal catalyst NPs. The model's performance in detecting and segmenting NPs is validated across diverse heterogeneous catalyst systems, including various metals (Ru, Cu, PtCo, and Pt), supports (silica (SiO 2 ), γ-alumina (γ-Al 2 O 3 ), and carbon black), and particle diameter size distributions with mean and standard deviations ranging from 1.6 ± 0.2 nm to 9.7 ± 4.6 nm. The proposed machine learning (ML) methodology achieved an average F1 overlap score of 0.91 ± 0.01 and demonstrated the ability to disentangle overlapping NPs anchored on catalytic support materials. The segmentation accuracy is further validated using the Hausdorff distance and robust Hausdorff distance metrics, with the 90th percent of the robust Hausdorff distance showing errors within 0.4 ± 0.1 nm to 1.4 ± 0.6 nm. In conclusion, our AI-assisted NP analysis workflow demonstrates robust generalization across diverse datasets and can be readily applied to similar NP segmentation tasks without requiring costly model retraining.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Changes in Distal Tibial Microarchitecture During Eight Weeks of U.S. Army Basic Combat Training Differ by Sex and Race

ABSTRACT Basic combat training (BCT) is a physically rigorous period at the beginning of a soldier's career that induces bone formation in the tibia. Race and sex are determinants of bone properties in young adults but their influences on changes in bone microarchitecture during BCT are unknown. The purpose of this work was to determine the influence of sex and race on changes in bone microarchitecture during BCT. Bone microarchitecture was assessed at the distal tibia via high‐resolution peripheral quantitative computed tomography at the beginning and end of 8 weeks of BCT in a multiracial cohort of trainees (552 female, 1053 male; mean ± standard deviation [SD] age = 20.7 ± 3.7 years) of which 25.4% self‐identified as black, 19.5% as race other than black or white (other races combined), and 55.1% as white. We used linear regression models to determine whether changes in bone microarchitecture due to BCT differed by race or sex, after adjusting for age, height, weight, physical activity, and tobacco use. We found that trabecular bone density (Tb.BMD), thickness (Tb.Th), and volume (Tb.BV/TV), as well as cortical BMD (Ct.BMD) and thickness (Ct.Th) increased following BCT in both sexes and across racial groups (+0.32% to +1.87%, all p < 0.01). Compared to males, females had greater increases in Tb.BMD (+1.87% versus +1.40%; p = 0.01) and Tb.Th (+0.87% versus +0.58%; p = 0.02), but smaller increases in Ct.BMD (+0.35% versus +0.61%; p < 0.01). Compared to black trainees, white trainees had greater increases in Tb.Th (+0.82% versus +0.61%; p = 0.03). Other races combined and white trainees had greater increases in Ct.BMD than black trainees (+0.56% and + 0.55% versus +0.32%; both p ≤ 0.01). Changes in distal tibial microarchitecture, consistent with adaptive bone formation, occur in trainees of all races and sexes, with modest differences by sex and race. Published 2023. This article is a U.S. Government work and is in the public domain in the USA. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

Hughes, Julie M.↗

Chemical evolution of local post-starburst galaxies: implications for the mass–metallicity relation

ABSTRACT We use the stellar fossil record to constrain the stellar metallicity evolution and star-formation histories of the post-starburst (PSB) regions within 45 local PSB galaxies from the MaNGA survey. The direct measurement of the regions’ stellar metallicity evolution is achieved by a new two-step metallicity model that allows for stellar metallicity to change at the peak of the starburst. We also employ a Gaussian process noise model that accounts for correlated errors introduced by the observational data reduction or inaccuracies in the models. We find that a majority of PSB regions (69 per cent at >1σ significance) increased in stellar metallicity during the recent starburst, with an average increase of 0.8 dex and a standard deviation of 0.4 dex. A much smaller fraction of PSBs are found to have remained constant (22 per cent) or declined in metallicity (9 per cent, average decrease 0.4 dex, standard deviation 0.3 dex). The pre-burst metallicities of the PSB galaxies are in good agreement with the mass–metallicity (MZ) relation of local star-forming galaxies. These results are consistent with hydrodynamic simulations, which suggest that mergers between gas-rich galaxies are the primary formation mechanism of local PSBs, and rapid metal recycling during the starburst outweighs the impact of dilution by any gas inflows. The final mass-weighted metallicities of the PSB galaxies are consistent with the MZ relation of local passive galaxies. Our results suggest that rapid quenching following a merger-driven starburst is entirely consistent with the observed gap between the stellar mass–metallicity relations of local star-forming and passive galaxies.

Leung, Ho-Hin (ORCID:0000000304865178)↗

Measurement of 𝑊⁢𝑊⁢𝑍 and 𝑍⁢𝐻 Production Cross Sections at $\sqrt{𝑠}$ = 13 and 13.6 TeV

A measurement is presented of the cross section in proton-proton collisions for the production of two 𝑊 bosons and one 𝑍 boson. It is based on data recorded by the CMS experiment at the CERN LHC at center-of-mass energies $\sqrt{𝑠}$ = 13 and 13.6 TeV, corresponding to an integrated luminosity of 200 fb −1 . Events with four charged leptons (electrons or muons) in the final state are selected. Both nonresonant 𝑊⁢𝑊⁢𝑍 production and 𝑍⁢𝐻 production, with the Higgs boson decaying into two 𝑊 bosons, are reported. For the first time, the two processes are measured separately in a simultaneous fit. Combining the two modes, signal strengths relative to the standard model (SM) predictions of 0.75$^{+0.34}_{−0.29}$ and 1.74$^{+0.71}_{−0.60}$ are measured for $\sqrt{𝑠}$ = 13 and 13.6 TeV, respectively. The observed (expected) significance for the triboson signal is 3.8 (2.5) standard deviations for $\sqrt{𝑠}$ = 13.6 TeV, thus providing the first evidence for triboson production at this center-of-mass energy. Combining the two modes and the two center-of-mass energies, the inclusive signal strength relative to the SM prediction is measured to be 1.03$^{+0.31}_{−0.28}$, with an observed (expected) significance of 4.5 (5.0) standard deviations.

Gauge bosons↗

Implications for primordial non-Gaussianity (f{sub NL}) from weak lensing masses of high-z galaxy clusters

The recent weak-lensing measurement of the dark matter mass of the high-redshift galaxy cluster XMMUJ2235.3-2557 of (8.5{+-}1.7)x10{sup 14}M{sub {center_dot}} at z=1.4, indicates that, if the cluster is assumed to be the result of the collapse of dark matter in a primordial Gaussian field in the standard lambda cold dark matter model, then its abundance should be <2x10{sup -3} clusters in the observed area. Here we investigate how to boost the probability of XMMUJ2235.3-2557, in particular, resorting to deviations from Gaussian initial conditions. We show that this abundance can be boosted by factors >3-10 if the non-Gaussianity parameter f{sub NL}{sup local} is in the range 150-200. This value is comparable to the limit for f{sub NL} obtained by current constraints from the cosmic microwave background. We conclude that mass determination of high-redshift, massive clusters can offer a complementary probe of primordial non-Gaussianity.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-667: Development and Validation of Dose Calculation for An Open-Source KV Treatment Planning System for Small Animal Radiotherapy

Purpose: An open-source, convolution/superposition based kV-treatment planning system(TPS) was developed for small animal radiotherapy from previously existed in-house MV-TPS. It is flexible and applicable to both step and shoot and helical tomotherapy treatment delivery. For initial commissioning process, the dose calculation from kV-TPS was compared with measurements and Monte Carlo(MC) simulations. Methods: High resolution, low energy kernels were simulated using EGSnrc user code EDKnrc, which was used as an input in kV-TPS together with MC-simulated x-ray beam spectrum. The Blue Water™ homogeneous phantom (with film inserts) and heterogeneous phantom (with film and TLD inserts) were fabricated. Phantom was placed at 100cm SSD, and was irradiated with 250 kVp beam for 10mins with 1.1cm × 1.1cm open field (at 100cm) created by newly designed binary micro-MLC assembly positioned at 90cm SSD. Gafchromic™ EBT3 film was calibrated in-phantom following AAPM TG-61 guidelines, and were used for measurement at 5 different depths in phantom. Calibrated TLD-100s were obtained from ADCL. EGS and MNCP5 simulation were used to model experimental irradiation set up calculation of dose in phantom. Results: Using the homogeneous phantom, dose difference between film and kV-TPS was calculated: mean(x)=0.9%; maximum difference(MD)=3.1%; standard deviation(σ)=1.1%. Dose difference between MCNP5 and kV-TPS was: x=1.5%; MD=4.6%; σ=1.9%. Dose difference between EGS and kV-TPS was: x=0.8%; MD=1.9%; σ=0.8%. Using the heterogeneous phantom, dose difference between film and kV-TPS was: x=2.6%; MD=3%; σ=1.1%; and dose difference between TLD and kV-TPS was: x=2.9%; MD=6.4%; σ=2.5%. Conclusion: The inhouse, open-source kV-TPS dose calculation system was comparable within 5% of measurements and MC simulations in both homogeneous and heterogeneous phantoms. The dose calculation system of the kV-TPS is validated as a part of initial commissioning process for small animal radiotherapy. The kV-TPS has the potential for accurate dose calculation for any kV treatment or imaging modalities.

60 APPLIED LIFE SCIENCES↗

On approaches to analyze the sensitivity of simulated hydrologic fluxes to model parameters in the community land model

Here, effective sensitivity analysis approaches are needed to identify important parameters or factors and their uncertainties in complex Earth system models composed of multi-phase multi-component phenomena and multiple biogeophysical-biogeochemical processes. In this study, the impacts of 10 hydrologic parameters in the Community Land Model on simulations of runoff and latent heat flux are evaluated using data from a watershed. Different metrics, including residual statistics, the Nash-Sutcliffe coefficient, and log mean square error, are used as alternative measures of the deviations between the simulated and field observed values. Four sensitivity analysis (SA) approaches, including analysis of variance based on the generalized linear model, generalized cross validation based on the multivariate adaptive regression splines model, standardized regression coefficients based on a linear regression model, and analysis of variance based on support vector machine, are investigated. Results suggest that these approaches show consistent measurement of the impacts of major hydrologic parameters on response variables, but with differences in the relative contributions, particularly for the secondary parameters. The convergence behaviors of the SA with respect to the number of sampling points are also examined with different combinations of input parameter sets and output response variables and their alternative metrics. This study helps identify the optimal SA approach, provides guidance for the calibration of the Community Land Model parameters to improve the model simulations of land surface fluxes, and approximates the magnitudes to be adjusted in the parameter values during parametric model optimization.

58 GEOSCIENCES↗

Safeguards Modeling for Advanced Nuclear Facility Design.

Future nuclear fuel cycle facilities will see a significant benefit from considering materials accountancy requirements early in the design process. The Material Protection, Accounting, and Control Technologies (MPACT) working group is demonstrating Safeguards and Security by Design (SSBD) for a notional electrochemical reprocessing facility as part of a 2020 Milestone. The idea behind SSBD is to consider regulatory requirements early in the design process to provide more optimized systems and avoid costly retrofits later in the design process. Safeguards modeling, using single analyst tools, allows the designer to efficiently consider materials accountancy approaches that meet regulatory requirements. However, safeguards modeling also allows the facility designer to go beyond current regulations and work toward accountancy designs with rapid response and lower thresholds for detection of anomalies. This type of modeling enables new safeguards approaches and may inform future regulatory changes. The Separation and Safeguards Performance Model (SSPM) has been used for materials accountancy system design and analysis. This paper steps through the process of designing a Material Control and Accountancy (MC&A) system, presents the baseline system design for an electrochemical reprocessing facility, and provides performance metrics from the modeling analysis. The most critical measurements in the electrochemical facility are the spent fuel input, electrorefiner salt, and U/TRU product output measurements. Finally, material loss scenario analysis found that measurement uncertainties (relative standard deviations) for Pu would need to be at 1% (random and systematic error components) or better in order to meet domestic detection goals or as high as 3% in order to meet international detection goals, based on a 100 metric ton per year plant size.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Search for a heavy resonance decaying to a pair of vector bosons in the lepton plus merged jet final state at $ \sqrt{s}=13 $ TeV

A search for a new heavy particle decaying to a pair of vector bosons (WW or WZ) is presented using data from the CMS detector corresponding to an integrated luminosity of 35.9 fb$^{−1}$ collected in proton-proton collisions at a centre-of-mass energy of 13 TeV in 2016. One of the bosons is required to be a W boson decaying to eν or μν, while the other boson is required to be reconstructed as a single massive jet with substructure compatible with that of a highly-energetic quark pair from a W or Z boson decay. The search is performed in the resonance mass range between 1.0 and 4.4 TeV. The largest deviation from the background-only hypothesis is observed for a mass near 1.4 TeV and corresponds to a local significance of 2.5 standard deviations. The result is interpreted as an upper bound on the resonance production cross section. Comparing the excluded cross section values and the expectations from theoretical calculations in the bulk graviton and heavy vector triplet models, spin-2 WW resonances with mass smaller than 1.07 TeV and spin-1 WZ resonances lighter than 3.05 TeV, respectively, are excluded at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Size exclusion deep bed filtration: Experimental and modelling uncertainties

A detailed uncertainty analysis associated with carboxyl-modified latex particle capture in glass bead-formed porous media enabled verification of the two theoretical stochastic models for prediction of particle retention due to size exclusion. At the beginning of this analysis it is established that size exclusion is a dominant particle capture mechanism in the present study: calculated significant repulsive Derjaguin-Landau-Verwey-Overbeek potential between latex particles and glass beads is an indication of their mutual repulsion, thus, fulfilling the necessary condition for size exclusion. Applying linear uncertainty propagation method in the form of truncated Taylor's series expansion, combined standard uncertainties (CSUs) in normalised suspended particle concentrations are calculated using CSUs in experimentally determined parameters such as: an inlet volumetric flowrate of suspension, particle number in suspensions, particle concentrations in inlet and outlet streams, particle and pore throat size distributions. Weathering of glass beads in high alkaline solutions does not appreciably change particle size distribution, and, therefore, is not considered as an additional contributor to the weighted mean particle radius and corresponded weighted mean standard deviation. Weighted mean particle radius and LogNormal mean pore throat radius are characterised by the highest CSUs among all experimental parameters translating to high CSU in the jamming ratio factor (dimensionless particle size). Normalised suspended particle concentrations calculated via two theoretical models are characterised by higher CSUs than those for experimental data. The model accounting the fraction of inaccessible flow as a function of latex particle radius excellently predicts normalised suspended particle concentrations for the whole range of jamming ratios. The presented uncertainty analysis can be also used for comparison of intra- and inter-laboratory particle size exclusion data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A metric for evaluating conformance robustness during geologic CO 2 sequestration operations

A metric for quantifying the robustness of a designation of conformance of a geologic CO 2 sequestration (GCS) project during its operational phase is developed and demonstrated. Conformance in this context is a measure of the degree to which the sequestration system is understood and can be accurately modeled along with the degree to which the storage system is performing as designed. The robustness of conformance quantifies the degree to which parameter values can deviate from their current nominal estimates and still produce model forecasts that meet the performance criteria for the GCS operation. We develop and demonstrate the approach on a simplified scenario to illustrate the concept using a single uncertain parameter (homogeneous reservoir permeability) and a single performance criterion (critical pressure at a monitoring well in the reservoir; i.e., one that may displace brine from the reservoir to an overlying drinking water aquifer for example). Increased confidence in conformance assessment as more monitoring data are obtained is incorporated through the standard error of the coefficient (reservoir permeability in the case presented here), which we designate as the concordance metric. As more monitoring data become available during the course of the GCS operation, the standard error of the coefficient decreases (in general), thereby leading to increased conformance robustness as a larger deviation from nominal is required to fail to meet performance criteria. Increasing conformance robustness over time builds confidence that a GCS project will continue to meet performance criteria during the life-span of the project, thereby supporting designations of conformance. Furthermore a lack of conformance robustness provides a critical warning that the performance criteria of the GCS operation are not robust against probabilistic and non-probabilistic uncertainty in model conceptualization and/or model parameters.

58 GEOSCIENCES↗

A novel approach to assess the treatment response using Gaussian random field in PET

Purpose: The assessment of early therapeutic response to anticancer therapy is vital for treatment planning and patient management in clinic. With the development of personal treatment plan, the early treatment response, especially before any anatomically apparent changes after treatment, becomes urgent need in clinic. Positron emission tomography (PET) imaging serves an important role in clinical oncology for tumor detection, staging, and therapy response assessment. Many studies on therapy response involve interpretation of differences between two PET images, usually in terms of standardized uptake values (SUVs). However, the quantitative accuracy of this measurement is limited. This work proposes a statistically robust approach for therapy response assessment based on Gaussian random field (GRF) to provide a statistically more meaningful scale to evaluate therapy effects. Methods: The authors propose a new criterion for therapeutic assessment by incorporating image noise into traditional SUV method. An analytical method based on the approximate expressions of the Fisher information matrix was applied to model the variance of individual pixels in reconstructed images. A zero mean unit variance GRF under the null hypothesis (no response to therapy) was obtained by normalizing each pixel of the post-therapy image with the mean and standard deviation of the pretherapy image. The performance of the proposed method was evaluated by Monte Carlo simulation, where XCAT phantoms (128{sup 2} pixels) with lesions of various diameters (2–6 mm), multiple tumor-to-background contrasts (3–10), and different changes in intensity (6.25%–30%) were used. The receiver operating characteristic curves and the corresponding areas under the curve were computed for both the proposed method and the traditional methods whose figure of merit is the percentage change of SUVs. The formula for the false positive rate (FPR) estimation was developed for the proposed therapy response assessment utilizing local average method based on random field. The accuracy of the estimation was validated in terms of Euler distance and correlation coefficient. Results: It is shown that the performance of therapy response assessment is significantly improved by the introduction of variance with a higher area under the curve (97.3%) than SUVmean (91.4%) and SUVmax (82.0%). In addition, the FPR estimation serves as a good prediction for the specificity of the proposed method, consistent with simulation outcome with ∼1 correlation coefficient. Conclusions: In this work, the authors developed a method to evaluate therapy response from PET images, which were modeled as Gaussian random field. The digital phantom simulations demonstrated that the proposed method achieved a large reduction in statistical variability through incorporating knowledge of the variance of the original Gaussian random field. The proposed method has the potential to enable prediction of early treatment response and shows promise for application to clinical practice. In future work, the authors will report on the robustness of the estimation theory for application to clinical practice of therapy response evaluation, which pertains to binary discrimination tasks at a fixed location in the image such as detection of small and weak lesion.

61 RADIATION PROTECTION AND DOSIMETRY↗

DISCOVERY OF HIGH-ENERGY AND VERY HIGH ENERGY {gamma}-RAY EMISSION FROM THE BLAZAR RBS 0413

We report on the discovery of high-energy (HE; E > 0.1 GeV) and very high energy (VHE; E > 100 GeV) {gamma}-ray emission from the high-frequency-peaked BL Lac object RBS 0413. VERITAS, a ground-based {gamma}-ray observatory, detected VHE {gamma} rays from RBS 0413 with a statistical significance of 5.5 standard deviations ({sigma}) and a {gamma}-ray flux of (1.5 {+-} 0.6{sub stat} {+-} 0.7{sub syst}) Multiplication-Sign 10{sup -8} photons m{sup -2} s{sup -1} ({approx}1% of the Crab Nebula flux) above 250 GeV. The observed spectrum can be described by a power law with a photon index of 3.18 {+-} 0.68{sub stat} {+-} 0.30{sub syst}. Contemporaneous observations with the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope detected HE {gamma} rays from RBS 0413 with a statistical significance of more than 9{sigma}, a power-law photon index of 1.57 {+-} 0.12{sub stat}+{sup 0.11}{sub -0.12sys}, and a {gamma}-ray flux between 300 MeV and 300 GeV of (1.64 {+-} 0.43{sub stat}{sup +0.31}{sub -0.22sys}) Multiplication-Sign 10{sup -5} photons m{sup -2} s{sup -1}. We present the results from Fermi-LAT and VERITAS, including a spectral energy distribution modeling of the {gamma}-ray, quasi-simultaneous X-ray (Swift-XRT), ultraviolet (Swift-UVOT), and R-band optical (MDM) data. We find that, if conditions close to equipartition are required, both the combined synchrotron self-Compton/external-Compton and the lepto-hadronic models are preferred over a pure synchrotron self-Compton model.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-202-11: Radiobiological Modeling of Tumor Response During Radiotherapy Based On Pre-Treatment Dynamic PET Imaging Data

Purpose: To evaluate the ability of a multiscale radiobiological model of tumor response to predict mid-treatment hypoxia images, based on pretreatment imaging of perfusion and hypoxia with [18-F]FMISO dynamic PET and glucose metabolism with [18-F]FDG PET. Methods: A mechanistic tumor control probability (TCP) radiobiological model describing the interplay between tumor cell proliferation and hypoxia (Jeong et al., PMB 2013) was extended to account for intra-tumor nutrient heterogeneity, dynamic cell migration due to nutrient gradients, and stromal cells. This extended model was tested on 10 head and neck cancer patients treated with chemoradiotherapy, randomly drawn from a larger MSKCC protocol involving baseline and mid-therapy dynamic PET scans. For each voxel, initial fractions of proliferative and hypoxic tumor cells were obtained by finding an approximate solution to a system of linear equations relating cell fractions to voxel-level FDG uptake, perfusion (FMISO K{sub 1}) and hypoxia (FMISO k{sub 3}). The TCP model then predicted their evolution over time up until the mid treatment scan. Finally, the linear model was reapplied to predict each lesion’s median hypoxia level (k{sub 3}[med,sim]) which in turn was compared to the FMISO k{sub 3}[med] measured at mid-therapy. Results: The average k3[med] of the tumors in pre-treatment scans was 0.0035 min{sup −1}, with an inter-tumor standard deviation of σ[pre]=0.0034 min{sup −1}. The initial simulated k{sub 3}[med,sim] of each tumor agreed with the corresponding measurements within 0.1σ[pre]. In 7 out of 10 lesions, the mid-treatment k{sub 3}[med,sim] prediction agreed with the data within 0.3σ[pre]. The remaining cases corresponded to the most extreme relative changes in k{sub 3}[med]. Conclusion: This work presents a method to personalize the prediction of a TCP model using pre-treatment kinetic imaging data, and validates the modeling of radiotherapy response by predicting changes in median hypoxia values during treatment. Variations from predicted response may be a useful biomarker, which should be further explored. Partially supported by NIH grant #1 R01 CA157770-01A1 and a grant from Varian Corporation.

60 APPLIED LIFE SCIENCES↗

Statistical analyses of reservoir and fracturing parameters for a multifractured shale oil reservoir in Mississippi

The use of multifractured horizontal wells has improved the efficiency of hydrocarbon extraction from shale gas and oil plays. It is highly desirable to estimate the characteristics of the reservoir and well fracturing through production data analysis. Production rate transient data from 16 wells in the Mississippi sections were analyzed to estimate local reservoir permeability and hydraulic fracture parameters. Key factors affecting well productivity have been identified for optimizing future well completion. Based on the theory of distance of investigation during transient linear flow, the reservoir matrix permeability of TMS was estimated to be between 53 nd and 210 nd, averaging at 116 nd. The matrix permeability follows the lognormal distribution and is considered homogeneous according to the coefficient of variation. The fracture half-length was estimated using the matrix permeability data from the rate transient analysis. The fracture half-length was found to have a mean value of 234 ft with a standard deviation of 66 ft in a normal distribution. The fracture conductivity was back-calculated by matching pseudosteady production rate data to Guo et al's (SPE Reserve Eval Eng.12, 2009, 879) productivity model for boundary-dominated flow. The fracture conductivity was estimated to range from 0.4 md-ft to 3.2 md-ft, averaging at 1.4 md-ft. Based on Guo et al's (SPE Reserve Eval Eng.12, 2009, 879) well productivity model applied to TMS condition, well productivity can be improved significantly by increasing fracture length and conductivity. Future TMS wells should be completed with conductivity values of greater than 10 md-ft.

04 OIL SHALES AND TAR SANDS↗

Observation of W + W – γ production in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector and constraints on anomalous quartic gauge-boson couplings

This Letter reports the observation of W + W – γ triboson production in 140 fb –1 of data collected by the ATLAS detector from proton–proton collisions at a centre-of-mass energy of $\sqrt{s}$ = 13 TeV at the LHC. Events with an opposite-charge eμ pair, a high transverse-momentum photon, and significant missing transverse momentum are considered. The observed (expected) significance of the signal is 5.9 (6.0) standard deviations. The measured fiducial cross-section, defined for the W + W – γ → e ± μ ∓ $ν\bar{ν}$γ final state is 6.2 ± 0.8 (stat.) ± 0.6 (sys.) fb, in good agreement with the Standard Model prediction of 6.1$^{+1.0}_{–0.7}$ fb. Constraints on the Wilson coefficients of 13 dimension-8 operators describing physics beyond the Standard Model through anomalous quartic gauge-boson couplings are derived using the effective field theory framework.

Anomalous quartic gauge couplings↗