Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Suggestions for improving the efficiency of ground-based neutron monitors for detecting solar neutrons

On the occasion of the June 3, 1982 intense gamma-ray solar flare a significant increase in counting rate due to solar neutrons was observed by the neutron monitors of Junsfraujoch and Lomnicky Stit located at middle latitudes and high altitudes. In spite of a larger detector employed and of the smaller solar zenith angle, the amplitude of the same event observed at Rome was much smaller and the statistical fluctuations of the salactic cosmic ray background higher than the ones registered at the two mountain stations, because of the greater atmospheric depth at which the Rome monitor is located. The effeciency for detecting a solar neutron event by a NM-64 monitor as a function of the Sun zenith angle, atmospheric depth and threshold rigidity of the station was studied.

Iucci, N.↗

X-ray spectroscopy with silicon pin and avalanche photo diodes

Results of an evaluation of silicon P-Intrinsic-N (PIN) photodiodes and Avalanche Photodiodes (APD) for the direct detection of soft x rays from 1 to 20 keV and for the detection of scintillation light output from CsI(TI) for higher x ray energies (30 to 1000 keV) are presented. About one keV resolution was achieved at room temperature for both the PIN and APD detectors for soft x rays (1 to 20 keV). Commercially available, low power (18 mV), low noise, hybrid preamplifiers, were used. These photodiodes were also coupled to CsI(TI) scintillator and obtained about 6 resolution at 662 keV. The photodiode frequency response matches well with the emission spectrum of the CsI(TI) scintillator providing good spectral resolution and a higher signal than NaI(TI) when viewed by conventional photomultipliers. A PIN-CsI(TI) combination provides a low energy threshold of around 60 keV while for the APD-CsI(TI) it is 15 keV.

Desai, U. D.↗

Measurement of fiducial and differential W + W − production cross-sections at s = 13 TeV with the ATLAS detector

A measurement of fiducial and differential cross-sections for W+W- production in proton-proton collisions at sqrt(s)=13 TeV with the ATLAS experiment at the Large Hadron Collider using an integrated luminosity of 36.1fb-1 is presented. Events with one electron and one muon are selected, corresponding to the decay of the diboson system as WW->e nu mu nu. To suppress top-quark background, events containing jets with a transverse momentum exceeding 35 GeV are not included in the measurement phase space. The fiducial cross-section, six differential distributions and the cross-section as a function of the jet-veto transverse momentum threshold are measured and compared with several theoretical predictions. Constraints on anomalous weak boson self-interactions are also presented in the framework of a dimension-six effective field theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nanocavity-Enhanced Giant Stimulated Raman Scattering in Si Nanowires in the Visible Light Region

Silicon photonics has been a very active area of research especially in the past two decades in order to meet the ever-increasing demand for more computational power and faster device speeds and their natural compatibility with complementary metal-oxide semiconductor. In order to develop Si as a useful photonics material, essential photonic components such as light sources, waveguides, wavelength convertors, modulators, and detectors need to be developed and integrated. However, due to the indirect electronic bandgap of Si, conventional light emission devices such as light-emitting diodes and lasers cannot be built. Therefore, there has been considerable interest in developing Si-based Raman lasers, which are nonlinear devices and require large stimulated Raman scattering (SRS) in an optical cavity. However, due to the low quantum yield of SRS in Si, Raman lasers have very large device footprints and high lasing threshold, making them unsuitable for faster, smaller, and energy-efficient devices. Here in this paper, we report strong SRS and extremely high Raman gain in Si nanowire optical cavities in the visible region with measured SRS threshold as low as 30 kW/cm 2 . At cavity mode resonance, light is confined into a low mode volume and high intensity electromagnetic mode inside the Si nanowire due to its high refractive index, which leads to strong SRS at low pump intensities. Electromagnetic calculations reveal greater than 6 orders of magnitude increase in Raman gain coefficient at 532 nm pump wavelength, compared to the gain value at 1.55 μm wavelength reported in literature, despite the 10 8 higher losses at 532 nm. Because of the high gain in such small structures, we believe that this is a significant first step in realizing a monolithically integrable nanoscale low-powered Si Raman laser.

36 MATERIALS SCIENCE↗

Search for new phenomena in different-flavour high-mass dilepton final states in $pp$ collisions at $\sqrt{s}=13$ Tev with the ATLAS detector

A search is performed for a heavy particle decaying into different flavour dilepton pairs (eμ, eτ or μτ), using 3.2 fb -1 of proton–proton collision data at $\sqrt{s}=13$ TeV collected in 2015 by the ATLAS detector at the Large Hadron Collider. No excess over the Standard Model prediction is observed. Limits at the 95 % credibility level are set on the mass of a Z' boson with lepton-flavour-violating couplings at 3.0, 2.7 and 2.6 TeV, and on the mass of a supersymmetric τ sneutrino with R-parity-violating couplings at 2.3, 2.2 and 1.9 TeV, for eμ, eτ and μτ final states, respectively. The results are also interpreted as limits on the threshold mass for quantum black hole production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Formation Control of the MAXIM L2 Libration Orbit Mission

The Micro-Arcsecond X-ray Imaging Mission (MAXIM), a proposed concept for the Structure and Evolution of the Universe (SEU) Black Hole Imager mission, is designed to make a ten million-fold improvement in X-ray image clarity of celestial objects by providing better than 0.1 micro-arcsecond imaging. Currently the mission architecture comprises 25 spacecraft, 24 as optics modules and one as the detector, which will form sparse sub-apertures of a grazing incidence X-ray interferometer covering the 0.3-10 keV bandpass. This formation must allow for long duration continuous science observations and also for reconfiguration that permits re-pointing of the formation. To achieve these mission goals, the formation is required to cooperatively point at desired targets. Once pointed, the individual elements of the MAXIM formation must remain stable, maintaining their relative positions and attitudes below a critical threshold. These pointing and formation stability requirements impact the control and design of the formation. In this paper, we provide analysis of control efforts that are dependent upon the stability and the configuration and dimensions of the MAXIM formation. We emphasize the utilization of natural motions in the Lagrangian regions to minimize the control efforts and we address continuous control via input feedback linearization (IFL). Results provide control cost, configuration options, and capabilities as guidelines for the development of this complex mission.

Folta, David↗

Measurement of the generalized form factors near pion threshold via gamma*p --> npi^+ in CLAS

We extracted the multipoles near pion threshold for the first time at high momentum transfers (Q2) in the nπ+ final state channel. The dominance of the S-wave transverse multipole (E0+) is expected in this region, which allows us to access the new generalized form factors G1, G2 within the Light-Cone-Sum-Rule (LCSR) framework. In this analysis, we used one of the recent CLAS experimental data sets which utilized the high-energy polarized electron beam on unpolarized proton target using the 4π detector coverage. We measured the differential cross sections and extracted the multipoles using two methods, LCSR and multipole fit. Both methods show consistent results, which are almost Q2 independent.

43 PARTICLE ACCELERATORS↗

Advancing the Search for Dark Matter: from CDMS II to SuperCDMS

An overwhelming proportion of the universe (83% by mass) is composed of particles we know next to nothing about. Detecting these dark matter particles directly, through hypothesized weak-force-mediated recoils with nuclear targets here on earth, could shed light on what these particles are, how they relate to the standard model, and how the standard model ts within a more fundamental understanding. This thesis describes two such experimental eorts: CDMS II (2007-2009) and SuperCDMS Soudan (ongoing). The general abilities and sensitivities of both experiments are laid out, placing a special emphasis on the detector technology, and how this technology has evolved from the rst to the second experiment. Some topics on which I spent signicant eorts are described here only in overview (in particular the details of the CDMS II analysis, which has been laid out many times before), and some topics which are not described elsewhere are given a somewhat deeper treatment. In particular, this thesis is hopefully a good reference for those interested in the annual modulation limits placed on the low-energy portion of the CDMS II exposure, the design of the detectors for SuperCDMS Soudan, and an overview of the extremely informative data these detectors produce. It is an exciting time. The technology I've had the honor to work on the past few years provides a wealth of information about each event, more so than any other direct detection experiment, and we are still learning how to optimally use all this information. Initial tests from the surface and now underground suggest this technology has the background rejection abilities necessary for a planned 200kg experiment or even ton-scale experiment, putting us on the threshold of probing parameter space orders of magnitude from where the eld currently stands.

79 ASTRONOMY AND ASTROPHYSICS↗

Observations of barium ion jets in the magnetosphere using Doppler imaging systems and very sensitive imaging systems using imaging photon detectors

Observations of four shaped charge releases from rockets launched from Alaska are described. Results demonstrate that imaging and Doppler imaging instruments, based on exploiting the imaging photon detector, provide additional insight into the motion and development of low intensity targets such as the fast ion jets produced by shaped charge releases. It is possible to trace the motion of fast ion jets to very great distances, of the order of 50,000 km, outward along the Earth's magnetic field, when the conditions are suitable for the outward (upward) motion and/or acceleration of such ion jets. It is shown that ion jets, which fade below the lower sensitivity threshold of previous instruments, do not always disappear. There is no evidence of an abrupt field-aligned shear-type acceleration.

Rees, D.↗

Investigation of statistical iterative reconstruction for dedicated breast CT

Purpose: Dedicated breast CT has great potential for improving the detection and diagnosis of breast cancer. Statistical iterative reconstruction (SIR) in dedicated breast CT is a promising alternative to traditional filtered backprojection (FBP). One of the difficulties in using SIR is the presence of free parameters in the algorithm that control the appearance of the resulting image. These parameters require tuning in order to achieve high quality reconstructions. In this study, the authors investigated the penalized maximum likelihood (PML) method with two commonly used types of roughness penalty functions: hyperbolic potential and anisotropic total variation (TV) norm. Reconstructed images were compared with images obtained using standard FBP. Optimal parameters for PML with the hyperbolic prior are reported for the task of detecting microcalcifications embedded in breast tissue.Methods: Computer simulations were used to acquire projections in a half-cone beam geometry. The modeled setup describes a realistic breast CT benchtop system, with an x-ray spectra produced by a point source and an a-Si, CsI:Tl flat-panel detector. A voxelized anthropomorphic breast phantom with 280 μm microcalcification spheres embedded in it was used to model attenuation properties of the uncompressed woman's breast in a pendant position. The reconstruction of 3D images was performed using the separable paraboloidal surrogates algorithm with ordered subsets. Task performance was assessed with the ideal observer detectability index to determine optimal PML parameters.Results: The authors' findings suggest that there is a preferred range of values of the roughness penalty weight and the edge preservation threshold in the penalized objective function with the hyperbolic potential, which resulted in low noise images with high contrast microcalcifications preserved. In terms of numerical observer detectability index, the PML method with optimal parameters yielded substantially improved performance (by a factor of greater than 10) compared to FBP. The hyperbolic prior was also observed to be superior to the TV norm. A few of the best-performing parameter pairs for the PML method also demonstrated superior performance for various radiation doses. In fact, using PML with certain parameter values results in better images, acquired using 2 mGy dose, than FBP-reconstructed images acquired using 6 mGy dose.Conclusions: A range of optimal free parameters for the PML algorithm with hyperbolic and TV norm-based potentials is presented for the microcalcification detection task, in dedicated breast CT. The reported values can be used as starting values of the free parameters, when SIR techniques are used for image reconstruction. Significant improvement in image quality can be achieved by using PML with optimal combination of parameters, as compared to FBP. Importantly, these results suggest improved detection of microcalcifications can be obtained by using PML with lower radiation dose to the patient, than using FBP with higher dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Chandra X-Ray Observatory Radiation Environmental Model Update

CRMFLX (Chandra Radiation Model of ion FLUX) is a radiation environment risk mitigation tool for use as a decision aid in planning the operation times for Chandra's Advanced CCD Imaging Spectrometer (ACIS) detector. The accurate prediction of the proton flux environment with energies of 100 - 200 keV is needed in order to protect the ACIS detector against proton degradation. Unfortunately, protons of this energy are abundant in the region of space where Chandra must operate. In addition, on-board particle detectors do not measure proton flux levels of the required energy range. CRMFLX is an engineering environment model developed to predict the proton flux in the solar wind, magnetosheath, and magnetosphere phenomenological regions of geospace. This paper describes the upgrades to the ion flux databases for the magnetosphere, magnetosheath, and solar wind regions. These data files were created by using Geotail and Polar spacecraft flux measurements only when the Advanced Composition Explorer (ACE) spacecraft's 0.14 MeV particle flux was below a threshold value. This new database allows for CRMFLX output to be correlated with both the geomagnetic activity level, as represented by the Kp index, as well as with solar proton events. Also, reported in this paper are results of analysis leading to a change in Chandra operations that successfully mitigates the false trigger rate for autonomous radiation events caused by relativistic electron flux contamination of proton channels.

Blackwell, William C.↗

Identification and repair of intermittent cable faults in nuclear power plants - 131

The nuclear industry uses cable circuits as an integral part of a plant's reactor protection system (RPS), instrumentation and control (I and C) and power distribution systems. The reliability of these systems is critical for continued operation of the world's aging nuclear fleet, as well as for safe shutdown of the reactor. When intermittent faults occur in cable circuits, the symptom of the problem often appears and disappears in milliseconds while the aftereffects can result in spurious alarms and automatic actuation of safety systems. Problems are compounded when component degradation causes a cable circuit to transmit inaccurate information that does not represent actual plant operating conditions. The root cause of intermittent cable circuit operation can include degradation of cable and connectors from heat, humidity, radiation, and vibration. Unlike hard faults (which are constant open or short circuits), intermittent faults are defined as a temporary change in impedance that may only last for a few milliseconds. While less disruptive than hard faults, signal spiking from intermittent faults can often lead to alarm conditions and reactor trips. A soft fault is defined as a subtle variation the electrical characteristics of the circuit that still permit the continued operation of the circuit. A soft fault may be a precursor to a hard fault due to continued degradation of the fault over time. The focus of this paper is the description of a cable testing system that can be connected to an active, low frequency circuit and continuously monitor electrical characteristics using the time domain reflectometry (TDR) technique until an intermittent impedance change occurs. This technique uses the difference in frequency response of the circuit and the TDR to isolate the TDR signature from the active circuit data . When a momentary impedance change occurs that exceeds a preconfigured limit threshold, the distance to fault data is automatically overlaid with the healthy baseline reference and stored in a database for diagnosis and repair. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗

Characterization of the First Prototype of the L1K65n Differential-Output Charge-Sensitive Preamplifier ASIC for High-Performance, Low-Background HPGe Detector Readout

Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.

ASIC↗

Harnessing the Quantum Zeno Effect in superconducting qubits for particle detection

Superconducting qubits, originally developed for quantum computing, are emerging as a potentially powerful tool for detecting low-energy particle interactions, such as dark matter and neutrinos. These devices can register energy deposits as small as a few meV, dramatically lowering the detection threshold compared to conventional sensors. However, their deployment in rare-event searches is hampered by a critical and unresolved background: Two-Level Systems (TLSes). TLSes are material defects that can scramble qubit frequencies and coherence times in a way that resembles particle energy deposits. Such false signals can critically limit the sensitivity and extend experimental runtimes for qubit-based sensors by years. This talk introduces a novel method to eliminate TLSes as a background source in superconducting qubit-based detectors. By harnessing the Quantum Zeno Effect (QZE), a well-established quantum phenomenon where frequent observation inhibits system evolution, I will discuss the possibility of “freezing” these TLS defects in place. This effectively suppresses their interference, stabilizes qubit behavior, and opens the door to using TLSes themselves as auxiliary sensors. I have already identified target TLSes and observed early signs of QZE-like dynamics in Fermilab-fabricated devices. The method builds on my existing collaborations at Fermilab’s Quantum Information Testbed (QUIET), with access to low muon flux cryogenic facilities 100 meters underground, control electronics, and expert mentors across multiple institutions. By removing a key bottleneck to superconducting sensor deployment, this research targets advancing the development of a general-purpose technique to enhance sensitivity, reduce false positives, and accelerate discovery in searches for dark matter, neutrinos, and other rare phenomena.

Seidel, Olivia [Texas U., Arlington]↗

A direct test of Auger cascade induced nucleation from heavy element contamination in C 3 F 8 bubble chambers

Understanding and quantifying the gamma-induced bubble nucleation background in clean nuclear recoil detection bubble chambers is of utmost importance to bubble chamber based dark matter searches. Here, we present data confirming the hypothesis that large Auger cascades from high-Z elements such as iodine and xenon dramatically increase the response of C 3 F 8 bubble chambers to gamma rays. These tests, performed with a small calibration bubble chamber filled with C 3 F 8 +$\mathcal{O}$ (10) ppm xenon, show that the probability of bubble nucleation scales with the rate of xenon inner-shell vacancies, reaching values >10% per K-Shell vacancy for Seitz thresholds of interest to future dark matter searches in bubble chambers. We also place an upper limit on bubble nucleation probability for argon Auger events, relevant to large future bubble chambers which may contain some residual atmospheric argon after the active fluid fill.

47 OTHER INSTRUMENTATION↗