Search NASA⌕ Search

SEARCH · Search NASA

Results for “absorption coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Optically addressed spatial light modulators by MBE-grown nipi MQW structures

Promising approaches for achieving optically addressed spatial light modulators (O-SLMs) are investigated based on combining nipi and multiple quantum well structures. Theoretical aspects of photooptic effects achievable in such structures are treated. Test structures are grown by molecular beam epitaxy using two material systems. (In,Ga)As/GaAs and (Al,Ga)As/GaAs. Experiments show large optically controlled modulation of the absorption coefficient in the quantum well layers, a log power dependence on the control signal, millisecond and shorter time response, and generally predictable behavior. The results are encouraging for several different O-SLM device structures proposed.

Maserjian, Joseph↗

Mapping transformations for broadband atmospheric radiation calculations

Two methods of mapping the line-by-line absorption coefficient (k) spectrum onto a new variable to produce a set of k coefficients which can be used for accurate and efficient broadband radiative transfer calculations in vertically inhomogeneous, nongray scattering atmospheres are described. These methods are intended for applications for which the less accurate correlated-k method is inadequate. These methods are tested for model atmospheres containing CO2 and H2O, with pressure in the range 0.05-0.9 bar. The results obtained differed by no more than 1 or 2 percent from the line-by-line results if the number of k coefficients was about 100 times less than the number required for the line-by-line calculation. These algorithms can be used for gas mixtures and for a variety of pressure-temperature profiles.

West, Robert↗

The physical and infrared spectral properties of CO2 in astrophysical ice analogs

Results of measurements of the infrared spectroscopic and condensation-vaporization properties of CO2 in pure and mixed ices are presented. Detailed examination of five infrared CO2 bands, 2.20, 2.78, 4.27, 15.2, and 4.39 microns, shows that the peak position, FWHM, and profile of the bands provide important information about the composition, formation, and subsequent thermal history of the ices. Absorption coefficients and their temperature dependence for all five CO2 bands are determined. The temperature dependence variation is found to be less than 15 percent from 10 to 150 K, i.e., the temperature at which H2O ice sublimes. The number of parameters associated with the physical behavior of CO2 in CO2- and H2O-rich ices, including surface binding energies, and condensation and sublimation temperatures, are determined under experimental conditions. The implications of the data obtained for cometary models are considered.

Sandford, S. A.↗

Spectral albedo and emissivity of CO2 in Martian polar caps - Model results

In this paper, a snow albedo model previously developed for terrestrial snow is extended to the case of CO2 snow on Mars. Pure CO2 snow is calculated to have high albedo at visible wavelengths but not as high as that of water snow. At any given wavelength, the primary variable controlling albedo and emissivity is the snow grain size, with albedo decreasing and emissivity increasing as grain size increases. Observations that red albedo is much higher than blue albedo in the Martian south polar cap indicates that the snow or the atmosphere is contaminated with red dust. The absorption coefficient of CO2 ice in the thermal infrared is two to three orders of magnitude smaller than that measured for H2O ice. CO2 snow emissivity is therefore much lower than H2O snow, varying substantially with wavelength and quite sensitive to grain size and emission angle. Factors tending to increase emissivity are large grain size, small emission angle, and large concentrations of dust or water.

Warren, Stephen G.↗

Multi-spectral window radiance observations of Cirrus from satellite and aircraft, November 2, 1986 Project FIRE

High resolution infrared radiance spectra achieved from the NASA ER2 airborne HIS experiment are used to analyze the spectral emissivity properties of cirrus clouds within the 8 to 12 micron atmospheric window region. Observations show that the cirrus emissivity generally decreases with increasing wavenumber (i.e., decreasing wavelength) within this band. A very abrupt decrease in emissivity (increase in brightness temperature) exists between 930/cm (10.8 microns) and 1000/cm (10.0 microns), the magnitude of the change being associated with the cirrus optical thickness as observed by lidar. The HIS observations are consistent with theoretical calculations of the spectral absorption coefficient for ice. The HIS observations imply that cirrus clouds can be detected unambiguously from the difference in brightness temperatures observed within the 8.2 and 11.0 micron window regions of the HIRS sounding radiometer flying on the operational NOAA satellites. This ability is demonstrated using simultaneous 25 km resolution HIRS observations and 1 km resolution AVHRR imagery achieved from the NOAA-9 satellite. Finally, the cirrus cloud location estimates combined with the 6.7 micron channel moisture imagery portray the boundaries of the ice/vapor phase of the upper troposphere moisture. This phase distinction is crucial for infrared radiative transfer considerations for weather and climate models, since upper tropospheric water vapor has little effect on the Earth's outgoing radiation whereas cirrus clouds have a very large attenuating effect.

Smith, William L.↗

Possibilities for LWIR detectors using MBE-grown Si(/Si(1-x)Ge(x) structures

Traditionally, long wavelength infrared (LWIR) detection in Si-based structures has involved either extrinsic Si or Si/metal Schottky barrier devices. Molecular beam epitaxially (MBE) grown Si and Si/Si(1-x)Ge(x) heterostructures offer new possibilities for LWIR detection, including sensors based on intersubband transitions as well as improved conventional devices. The improvement in doping profile control of MBE in comparison with conventional chemical vapor deposited (CVD) Si films has resulted in the successful growth of extrinsic Si:Ga, blocked impurity-band conduction detectors. These structures exhibit a highly abrupt step change in dopant profile between detecting and blocking layers which is extremely difficult or impossible to achieve through conventional epitaxial growth techniques. Through alloying Si with Ge, Schottky barrier infrared detectors are possible, with barrier height values between those involving pure Si or Ge semiconducting materials alone. For both n-type and p-type structures, strain effects can split the band edges, thereby splitting the Schottky threshold and altering the spectral response. Measurements of photoresponse of n-type Au/Si(1-x)Ge(x) Schottky barriers demonstrate this effect. For intersubband multiquntum well (MQW) LWIR detection, Si(1-x)Ge(x)/Si detectors grown on Si substrates promise comparable absorption coefficients to that of the Ga(Al)As system while in addition offering the fundamental advantage of response to normally incident light as well as the practical advantage of Si-compatibility. Researchers grew Si(1-x)Ge(x)/Si MQW structures aimed at sensitivity to IR in the 8 to 12 micron region and longer, guided by recent theoretical work. Preliminary measurements of n- and p-type Si(1-x)Ge(x)/Si MQW structures are given.

Hauenstein, Robert J.↗

MBE HgCdTe heterostructure detectors

HgCdTe has been the mainstay for medium (3 to 5 micron) and long (10 to 14 micron) wavelength infrared detectors in recent years. Conventional growth and processing techniques are continuing to improve the material. However, the additional ability to tailor composition and placement of doped layers on the tens of angstroms scale using molecular beam epitaxy (MBE) provides the opportunity for new device physics and concepts to be utilized. MBE-based device structures to be discussed here can be grouped into two categories: tailored conventional structures and quantum structures. The tailored conventional structures are improvements on familiar devices, but make use of the ability to create layers of varying composition, and thus band gap, at will. The heterostructure junction can be positioned independently of doping p-n junctions. This allows the small band gap region in which the absorption occurs to be separated from a larger band gap region in which the electric field is large and where unwanted tunneling can occur. Data from hybrid MBE/liquid phase epitaxy (LPE)/bulk structures are given. Quantum structures include the HgTe-CdTe superlattice, in which the band gap and transport can be controlled by alternating thin layers (tens of angstroms thick) of HgTe and CdTe. The superlattice has been shown to exhibit behavior which is non-alloy like, including very high hole mobilities, two-dimensional structure in the absorption coefficient, resonant tunneling, and anisotropic transport.

Schulman, Joel N.↗

Synthesis and structures of metal chalcogenide precursors

The reactivity of early transition metal sandwich complexes with sulfur-rich molecules such as dithiocarboxylic acids was studied. Researchers recently initiated work on precursors to CuInSe2 and related chalcopyrite semiconductors. Th every high radiation tolerance and the high absorption coefficient of CuInSe2 makes this material extremely attractive for lightweight space solar cells. Their general approach in early transition metal chemistry, the reaction of low-valent metal complexes or metal powders with sulfur and selenium rich compounds, was extended to the synthesis of chalcopyrite precursors. Here, the researchers describe synthesis, structures, and and routes to single molecule precursors to metal chalcogenides.

Hepp, Aloysius F.↗

Study of activation of metal samples from LDEF-1 and Spacelab-2

The activation of metal samples and other material orbited onboard the Long Duration Exposure Facility (LDEF) and Spacelab-2 were studied. Measurements of the radioactivities of spacecraft materials were made, and corrections for self-absorption and efficiency were calculated. Activation cross sections for specific metal samples were updated while cross sections for other materials were tabulated from the scientific literature. Activation cross sections for 200 MeV neutrons were experimentally determined. Linear absorption coefficients, half lives, branching ratios and other pertinent technical data needed for LDEF sample analyses were tabulated. The status of the sample counting at low background facilities at national laboratories is reported.

Laird, C. E.↗

The coupling of radiative transfer to quasi 1-D flows with thermochemical nonequilibrium

Quasi-one-dimensional nonequilibrium nozzle flows with coupled radiative transfer are considered. The strongly coupled formulation of radiation and flowfield leads to a governing set of integro-differential equations. A fully implicit numerical method using the full matrix inversion or block iteration methods is presented to solve these equations. The nonequilibrium gas model consists of two chemical species, molecular and atomic nitrogen. The thermodynamic state of the gas is described by two temperatures, translational-rotational and vibrational, and the thermal radiation is assumed to be governed by the vibrational temperature. In radiative transfer, gases are assumed to be absorbing and emitting, and a detailed spectral dependency of the absorption coefficient is prescribed for a non-gray gas. The numerical solutions of strongly radiating nonequilibrium flows are presented for both gray and non-gray gases.

Gokcen, Tahir↗

Properties of scatterers in the troposphere and lower stratosphere of Uranus based on Voyager imaging data

Scalar and vector radiative transfer and microphysical models are presently constructed from photometrically and geometrically corrected Voyager images of Uranus defining spatially-resolved intensities over a range of phase angles for two latitude bands. The methane ice cloud occupying 1.2-1.3 bar is of 0.7 optical depth at 22.5 deg S, rising to 2.4 at 65 deg S; the volume absorption coefficient of the cloud particles is 50 percent greater at the low latitude than at the high, assuming constant mean cloud particle size. The scattering model also includes photochemically-produced stratospheric hydrocarbon ices in the upper troposphere and stratosphere, as well as an optically thick hydrogen sulfide cloud.

Rages, Kathy↗

IRAS detection of very cold dust in the Lynds 134 cloud complex

IRAS maps at 60 and 100 microns of the complex of dark clouds containing L1345, L183, and L1780 are presented and discussed. Extended regions are apparent where the 60 micron emission is very low compared to the 100 micron emission. The 60-100 micron flux ratio has a constant value of 0.2 in the outer diffuse parts of the clouds but suddenly drops to less than 0.03 in the opaque cloud centers. A geometrical model is used to show that the drop occurs in a narrow transition layer that has not been resolved by IRAS. The observations provide direct evidence for dust temperatures colder than 15 K in dark clouds. A number of 60 micron-deficient regions are defined using the quantity Delta I(100) = I(60)/Theta, where Theta is the ratio I(60)/I(100) in the diffuse parts of the complex. Delta I(100) is highly proportional to extinction and (C-13)O column density. The relationships indicate that the dust temperature must be constant over a large fraction of the volume sampled by Delta I(100). An upper limit of 4.8 g/sq cm is obtained for the mass absorption coefficient of dust at 100 microns.

Laureijs, R. J.↗

Thin-film power-density meter for millimeter wavelengths

A quasi-optical power density meter for millimeter and submillimeter wavelengths has been developed. The device is a 2-cm2 thin-film bismuth bolometer deposited on a mylar membrane. The resistance responsivity is 150 Ohms/W, and the time constant is 1 min. The meter is calibrated at DC. The bolometer is much thinner than a wavelength, and can thus be modeled as a lumped resistance in a transmission-line equivalent circuit. The absorption coefficient is 0.5 for 189-Ohms/square film. The power-density meter has been used to measure absolute power densities for millimeter-wave antenna efficiency measurements. Absolute power densities of 0.5 mW/sq cm have been measured to an estimated accuracy of 5 percent.

Lee, Karen A.↗

Electronic absorption spectroscopy of matrix-isolated polycyclic aromatic hydrocarbon cations. I - The naphthalene cation (C10H8/+/)

The ultraviolet, visible, and near-infrared absorption spectra of naphthalene (C10H8) and its radical ion (C10H8/+/), formed by vacuum ultraviolet irradiation, were measured in argon and neon matrices at 4.2 K. The associated vibronic band systems and their spectroscopic assignments are discussed together with the physical and chemical conditions governing ion production in the solid phase. The absorption coefficients were calculated for the ion and found lower than previous values, presumably due to the low polarizability of the neon matrix.

Salama, F.↗

ARCFLO analysis for high-enthalpy arc heaters

Feasibility, physical constraints, and preliminary design and operating envelope are calculated for a next-generation segmented arc heater with enthalpies of 70-90 MJ/kg, for simulation of fast lunar or Martian return trajectories. The ARCFLO computer program is modified for improved accuracy in high-enthalpy radiation-dominated flows. The ARCFLO band-radiation model is compared with the state-of-the-art spectral-radiation code NEQAIR. The band-radiation model is corrected, and band-absorption coefficients are reduced by up to 40 percent at high temperatures. Parametric studies show that, with conventional wall-heating limitations, high mass flow and high enthalpy are contradictory design goals owing to the increase of radiation losses with pressure, current density, and constrictor diameter. With existing hardware limitations, an enthalpy of 70 MJ/kg with a flow rate of 0.1 kg/s can be achieved in a constrictor with 5-6 cm diameter operating near 3-atm stagnation pressure. The total power is under 100 MW, but the current is very high: 14,000-18,000 amperes.

Milos, Frank S.↗

The effect of drop-size distribution variability on radiometric estimates of rainfall rates for frequencies from 3 to 10 GHz

An attempt is made to quantify and document the dependence of the strength and the linearity of the relation between the absorption coefficient of the rain k sub a and rainfall rates R for frequencies from 3 to 10 GHz. It is shown that the physical link between R and k sub a varies depending upon microwave frequency. The weaker the relation the more sensitive k sub a and R to variations in the drop-size distribution. The scatter in k sub a and R is found to be greatest at 8 GHz and smallest at 3 GHz in response to variations to drop-size distribution.

Jameson, A. R.↗

Laboratory scaled simulation of lidar cloud sounding experiments

The results of lidar measurements carried out on laboratory scale models of clouds are presented. Measurements on laboratory scale models are important since one has the knowledge of the relevant parameters of the diffusing medium, such as: scattering and absorption coefficients, phase function, homogeneity, shape, etc. Knowledge of these parameters enables one to use the results to test the reliability of theoretical and numerical investigations. To obtain a laboratory scaled model of a lidar system sounding a cloud, it is necessary to scale down all the geometrical quantities by the same factor to reduce distances of the order of kilometers to the order of meters, keeping the size and the optical depth of the diffusers unchanged. If a time resolution of the order of nanoseconds is necessary for a lidar sounding actual clouds, the corresponding time resolution for the laboratory model should be of the order of picoseconds. It is possible to obtain this resolution by using picosecond laser systems and fast electrooptical detectors like the streak camera. The results of the laboratory measurements showed that the multiple scattering effect strongly depends on the size of the diffusers, as well as on the concentration. The experimental results were compared with the numerical results of a Monte Carlo code. A generally good agreement was obtained.

Zaccanti, G.↗