Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Experiment Liaison Duties

The continuous electron beam accelerator facility (CEBAF) at Jefferson Lab (JLAB) hosts unique and specialized experiments simultaneous with routine experiments in other end-stations. These unique experiments often have specialized beam requirements, new beamline configurations including diagnostic devices, and well defined commissioning periods. Each experiment's needs are different, so the Jefferson Lab Operations Group assigns an Experiment Liaison, a single crew chief or operator who works directly with experiment representatives during planning, commissioning and installation. This poster shows how the Experiment Liaison plays a key role in planning the beam instrumentation requirements, drafting experiment-specific setup procedures, and training Operations staff before the first beam is ever delivered to the experiment.

Aiken, Michael↗

Proteus three-dimensional Navier-Stokes computer code, version 1.0. Volume 2: User's guide

A computer code called Proteus 3D was developed to solve the three-dimensional, Reynolds-averaged, unsteady compressible Navier-Stokes equations in strong conservation law form. The objective in this effort was to develop a code for aerospace propulsion applications that is easy to use and easy to modify. Code readability, modularity, and documentation were emphasized. The governing equations are solved in generalized nonorthogonal body-fitted coordinates, by marching in time using a fully-coupled ADI solution procedure. The boundary conditions are treated implicitly. All terms, including the diffusion terms, are linearized using second-order Taylor series expansions. Turbulence is modeled using either an algebraic or two-equation eddy viscosity model. The thin-layer or Euler equations may also be solved. The energy equation may be eliminated by the assumption of constant total enthalpy. Explicit and implicit artificial viscosity may be used. Several time step options are available for convergence acceleration. The documentation is divided into three volumes. This User's Guide describes the program's features, the input and output, the procedure for setting up initial conditions, the computer resource requirements, the diagnostic messages that may be generated, the job control language used to run the program, and several test cases.

Towne, Charles E.↗

Arctic Amplification: Process Drivers and Sources of Uncertainty

Arctic amplification (AA) is a coupled atmosphere-sea ice-ocean process. This understanding has evolved from the early concept of AA, as a consequence of snow ice line progressions, through more than a century of research that has clarified the relevant processes and driving mechanisms of AA. The predictions made by early modeling studies, namely the fall/winter maximum, bottom-heavy structure, the prominence of surface albedo feedback, and the importance of stable stratification have withstood the scrutiny of multi-decadal observations and more complex models. Yet, the uncertainty in Arctic climate projections is larger than in any other region of the planet, making the assessment of high-impact, near-term regional changes difficult or impossible. Reducing this large spread in Arctic climate projections requires a quantitative process understanding. This presentation synthesizes current knowledge of AA and describes a set of recommendations to guide future research. It briefly reviews the history of AA science, summarizes observed Arctic changes, discusses modeling approaches and feedback diagnostics, and assesses the current understanding of the most relevant feedbacks to AA. These sections culminate in a conceptual model of the fundamental physical mechanisms causing AA and a collection of recommendations to accelerate progress towards reduced uncertainty in Arctic climate projections. Our conceptual model highlights the need to account for local feedback and remote process interactions within the context of the annual cycle to constrain projected AA.

Patrick C Taylor↗

Advanced Photon Acceleration Schemes for Tunable XUV/Soft X-Ray Sources

We report on the advances made under the purview of DOE award number DE-SC0019135 that was active during the period: 09/01/2018–08/31/2021. The grant investigated the application of a “flying focus” to the problem of photon acceleration—in which a dynamic refractive index gradient is used to continuously upshift a probe beam’s frequency. Codes were written to describe the creation of ionization waves of arbitrary velocity (IWAVs) for use as a photon-accelerating medium, as well as the behavior of a witness pulse residing in said medium. Experiments first verified the spatiotemporal control over laser intensity provided by a chromatic flying focus, then used that ability to produce small-diameter IWAVs in the far-field with the expected dynamics, and finally demonstrated even further flexibility by producing large-diameter IWAVs in the laser quasi-far-field that maintained the beneficial dynamics. Multiple innovative diagnostics—spectrally resolved Schlieren and spectrally resolved interferometry—were pioneered in order to diagnose the IWAVs. For IWAV production in the laboratory, however, beam quality was identified as a key limitation in the quasi-far-field. Since the original chromatic flying focus was found to result in relatively long (ps duration) intensity peaks, which could limit some applications including photon acceleration, additional techniques were invented to provide similar spatiotemporal control while also retaining ultrashort intensity peaks. While simulations have identified several interesting regimes for photon acceleration—first predicting the upshift of a counterpropagating witness pulse from the optical to the extreme ultraviolet in less than 1 cm, and later obtaining similar shifts in less than 100 μm in a simpler self-seeded configuration—experimental demonstration is left for future work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Nonlinear Dynamics of Intense Charged Particle Beams in the Paul Trap Simulator Experiment

The Paul Trap Simulator Experiment (PTSX) is a compact laboratory device that simulates the nonlinear dynamics of intense charged particle beams propagating over a large distance in an alternating-gradient magnetic transport system. The radial quadrupole electric eld forces on the charged particles in the Paul Trap are analogous to the radial forces on the charged particles in the quadrupole magnetic transport system. The amplitude of oscillating voltage applied to the cylindrical electrodes in PTSX is equivalent to the quadrupole magnetic eld gradient in accelerators. The temporal periodicity in PTSX corresponds to the spatial periodicity in magnetic transport system. This thesis focuses on investigations of envelope instabilities and collective mode excitations, properties of high-intensity beams with significant space-charge effects, random noise-induced beam degradation and a laser-induced-fluorescence diagnostic. To better understand the nonlinear dynamics of the charged particle beams, it is critical to understand the collective processes of the charged particles. Charged particle beams support a variety of collective modes, among which the quadrupole mode and the dipole mode are of the greatest interest. We used quadrupole and dipole perturbations to excite the quadrupole and dipole mode respectively and study the effects of those collective modes on the charge bunch. The experimental and particle-in-cell (PIC) simulation results both show that when the frequency and the spatial structure of the external perturbation are matched with the corresponding collective mode, that mode will be excited to a large amplitude and resonates strongly with the external perturbation, usually causing expansion of the charge bunch and loss of particles. Machine imperfections are inevitable for accelerator systems, and we use random noise to simulate the effects of machine imperfection on the charged particle beams. The random noise can be Fourier decomposed into various frequency components and experimental results show that when the random noise has a large frequency component that matches a certain collective mode, the mode will also be excited and cause heating of the charge bunch. It is also noted that by rearranging the order of the random noise, the adverse effects of the random noise may be eliminated. As a non-destructive diagnostic method, a laser-induced- fluorescence (LIF) diagnostic is developed to study the transverse dynamics of the charged particle beams. The accompanying barium ion source and dye laser system are developed and tested.

LIF↗

Wire scanner assessment of transverse beam size in the Fermilab side-coupled linac

The Fermilab Side-Coupled Linac contains seven 805 MHz modules accelerating H- beam from 116 MeV to 400 MeV. Each module contains at least one wire scanner, yielding beam intensity at positions along a transverse direction. These wire scanners each contain three wires, mounted at different angles: "X", "Y", and 45° between "X" and "Y" to analyze coupling. Recently, a significant amount of transverse X-Y coupling was identified within wire scanner data from the Side-Coupled Linac, which has been present in data from the past decade. This realization has prompted an investigation into the wire scanner's utility as a diagnostic tool in the Fermilab Linac. This work presents efforts to better characterize the wire scanners' limitations and the phenomenon occurring in the Side-Coupled Linac.

43 PARTICLE ACCELERATORS↗

Automated 3D cytoplasm segmentation in soft X-ray tomography

Cells’ structure is key to understanding cellular function, diagnostics, and therapy development. Soft X-ray tomography (SXT) is a unique tool to image cellular structure without fixation or labeling at high spatial resolution and throughput. Fast acquisition times increase demand for accelerated image analysis, like segmentation. Currently, segmenting cellular structures is done manually and is a major bottleneck in the SXT data analysis. This paper introduces ACSeg, an automated 3D cytoplasm segmentation model. ACSeg is generated using semi-automated labels and 3D U-Net and is trained on 43 SXT tomograms of immune T cells, rapidly converging to high-accuracy segmentation, therefore reducing time and labor. Furthermore, adding only 6 SXT tomograms of other cell types diversifies the model, showing potential for optimal experimental design. ACSeg successfully segmented unseen tomograms and is published on Biomedisa, enabling high-throughput analysis of cell volume and structure of cytoplasm in diverse cell types.

59 BASIC BIOLOGICAL SCIENCES↗

Laser-driven 1 GeV carbon ions from preheated diamond targets in the break-out afterburner regime

Experimental data are presented for laser-driven carbon C{sup 6+} ion-acceleration, verifying 2D-PIC studies for multi-species targets in the Break-Out Afterburner regime. With Trident's ultra-high contrast at relativistic intensities of 5 × 10{sup 20} W/cm{sup 2} and nm-scale diamond targets, acceleration of carbon ions has been optimized by using target laser-preheating for removal of surface proton contaminants. Using a high-resolution wide angle spectrometer, carbon C{sup 6+} ion energies exceeding 1 GeV or 83 MeV/amu have been measured, which is a 40% increase in maximum ion energy over uncleaned targets. These results are consistent with kinetic plasma modeling and analytic theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microjet formation and hard x-ray production from a liquid metal target irradiated by intense femtosecond laser pulses

By using a liquid metal as a target one may significantly enhance the yield of hard x-rays with a sequence of two intense femtosecond laser pulses. The influence of the time delay between the two pulses is studied experimentally and interpreted with numerical simulations. It was suggested that the first arbitrary weak pulse produces microjets from the target surface, while the second intense pulse provides an efficient electron heating and acceleration along the jet surface. These energetic electrons are the source of x-ray emission while striking the target surface. The microjet formation is explained based on the results given by both optical diagnostics and hydrodynamic modeling by a collision of shocks originated from two distinct zones of laser energy deposition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Injection System Diagnostics

The linac beam diagnostics will be provided by Research Instruments (former ACCEL) as part of the linac package: • one removable Faraday cup after electron source, • five wall current monitors (WCM) located after electron source, bunching system and accelerating sections 1, 2, and 3, • six removable YAG:Ce screens including cameras, • five sets of buttons for beam position monitoring. BNL will provide receivers for the beam position monitors (BPMs).

36 MATERIALS SCIENCE↗

Explosive component acceptance tester using laser interferometer technology

Acceptance testing of explosive components requires a reliable and simple to use testing method that can discern less than optimal performance. For hot-wire detonators, traditional techniques use dent blocks or photographic diagnostic methods. More complicated approaches are avoided because of their inherent problems with setup and maintenance. A recently developed tester is based on using a laser interferometer to measure the velocity of flying plates accelerated by explosively actuated detonators. Unlike ordinary interferometers that monitor displacement of the test article, this device measures velocity directly and is commonly used with non-spectral surfaces. Most often referred to as the VISAR technique (Velocity Interferometer System for Any Reflecting Surface), it has become the most widely-accepted choice for accurate measurement of velocity in the range greater than 1 mm/micro-s. Traditional VISAR devices require extensive setup and adjustment and therefore are unacceptable in a production-testing environment. This paper describes a new VISAR approach which requires virtually no adjustments, yet provides data with accuracy comparable to the more complicated systems. The device, termed the Fixed-Cavity VISAR, is currently being developed to serve as a product verification tool for hot-wire detonators and slappers. An extensive data acquisition and analysis computer code was also created to automate the manipulation of raw data into final results.

Wickstrom, Richard D.↗

The FRC Acceleration Space Thruster (FAST) Experiment

The objective of the FRC (Field Reversed Configuration) Acceleration Space Thruster (FAST) Experiment is to investigate the use of a repetitive FRC source as a thruster, specifically for an NEP (nuclear electric propulsion) system. The Field Reversed Configuration is a plasmoid with a closed poloidal field line structure, and has been extensively studied as a fusion reactor core. An FRC thruster works by repetitively producing FRCs and accelerating them to high velocity. An FRC thruster should be capable of I(sub sp)'s in the range of 5,000 - 25,000 seconds and efficiencies in the range of 60 - 80 %. In addition, they can have thrust densities as high as 10(exp 6) N/m2, and as they are inductively formed, they do not suffer from electrode erosion. The jet-power should be scalable from the low to the high power regime. The FAST experiment consists of a theta-pinch formation chamber, followed by an acceleration stage. Initially, we will produce and accelerate single FRCs. The initial focus of the experiment will be on the ionization, formation and acceleration of a single plasmoid, so as to determine the likely efficiency and I(sub sp). Subsequently, we will modify the device for repetitive burst-mode operation (5-10 shots). A variety of diagnostics are or will be available for this work, including a HeNe interferometer, high-speed cameras, and a Thomson-scattering system. The status of the experiment will be described.

Martin, Adam↗

First Test Results of the New LANSCE Wire Scanner

The Beam Diagnostics and Instrumentation Team (BDIT) at Los Alamos National Laboratory's LANSCE facility is presently developing a new and improved wire scanner diagnostics system controlled by National Instrument's cRIO platform. This paper describes the current state of development of the control system along with the results gathered from the latest actuator motion performance and accelerator-beam data acquisition tests.

Accelerator Design, Technology, and Operations↗

Preliminary Kinetic Analysis of Non-Equilibrium Plasma- Assisted Methanol Pyrolysis and Oxidation Experiments

Efforts to enhance power generation efficiency and reduce emissions have driven interest in novel combustion techniques, including non-equilibrium plasma (NEP) ignitors. NEP ignitors show promise in improving energy conversion efficiency, fuel reforming, emission control, and lean-flammability limits. However, their adoption is hindered by a limited understanding of the interplay between plasma-enhanced combustion and thermal chemistry, particularly for complex fuels under engine-relevant conditions. Developing experimentally validated kinetic mechanisms is therefore critical. Additionally, the increasing interest in renewable biofuels like ethanol and methanol, coupled with the desirable qualities of NEP ignitors, presents a compelling opportunity for study. Therefore, this work acts as an extension of a previous work (Bopaiah et al., 2023) pertaining to the experimental results of NEP-assisted methanol pyrolysis and oxidation. Experiments were performed with a custom-built plasma flow reactor at 0.5 atm and temperatures from 523-1203 K. All reactive mixtures are extremely diluted to minimize exothermicity due to reactivity, allowing isothermal assumptions and the isolation of plasma chemistry from thermal chemistry. A dielectric barrier discharge plasma, at 14 kV and 15 ns full-width half maximum, was applied to the reactive mixture at varying frequencies to maintain the number of pulses with increasing temperature. Steady-state product speciation was performed downstream of the reactor with ex-situ GC/MS diagnostics. The attained experimental results were examined through in-depth analysis performed by means of an in-development plasma-coupled kinetic mechanism. As discussed in the previous work, the plasma significantly accelerates methanol pyrolysis, increasing stable intermediate production, including oxygenated and nitrile species. Plasma-assisted oxidation shows even faster fuel consumption compared to pyrolysis and a 200 K ignition shift compared to thermal oxidation. For plasma-assisted pyrolysis, the model demonstrates that accelerated fuel consumption stems from dissociative quenching of excited N2 states with fuel and H2, generating H radicals that react to rapidly form CH3 and CH2OH radicals. At low temperatures, these radicals recombine to produce oxygenates, while CH3 drives nitrile and hydrocarbon formation at higher temperatures. While the model captures pyrolysis trends well, discrepancies in methane, ethylene, and ethanol predictions are present. Similarly, the model faces challenges in accurately representing plasma-assisted oxidation, predicting a much steeper fuel gradient and ignition 100 K earlier than the experiment. While a similar scheme to pyrolysis is nested in the reaction pathway, the enhancement of the O and H radical fluxes and their initiation of the OH and HO2 radical pools dominate fuel and intermediate oxidation. The overestimation of these processes is shown to be responsible for the divergence of model from experiment. While the modelling predictions of this preliminary mechanism are not perfect, they serve as a valuable starting point. Primarily, they elicited new reaction pathways that are not otherwise possible in thermal chemistry induced reaction kinetics. The results also provide a basis for the future work that should be performed. For example, theoretical and experimental studies on excited nitrogen species and fuel/fuel radical interactions, quantification of the NOx production, and the kinetics behind the slow ignition observed in oxidation should be emphasized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PROGRESS IN BEAM FOCUSING AND COMPRESSION FOR WARM-DENSE MATTER EXPERIMENTS

The Heavy-Ion Fusion Sciences Virtual National Laboratory is pursuing an approach to target heating experiments in the Warm Dense Matter regime, using spacecharge-dominated ion beams that are simultaneously longitudinally bunched and transversely focused. Longitudinal beam compression by large factors has beendemonstrated in the Neutralized Drift Compression Experiment (NDCX) with controlledramps and forced neutralization. Using an injected 30-mA K+ ion beam with initialkinetic energy 0.3 MeV, axial compression leading to ~;;50-fold current amplification andsimultaneous radial focusing to beam radii of a few mm have led to encouraging energy deposition approaching the intensities required for eV-range target heating experiments. We discuss the status of several improvements to our Neutralized Drift Compression Experiment and associated beam diagnostics that are under development to reach the necessary higher beam intensities, including: (1) greater axial compression via a longer velocity ramp using a new bunching module with approximately twice the available voltseconds; (2) improved centroid control via beam steering dipoles to mitigate aberrations in the bunching module; (3) time-dependent focusing elements to correct considerable chromatic aberrations; and (4) plasma injection improvements to establish a plasma density always greater than the beam density, expected to be>1013 cm-3.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid

Purpose: Medical linear accelerator mounted cone beam CT (CBCT) scanner provides useful soft tissue contrast for purposes of image guidance in radiotherapy. The presence of extensive scattered radiation has a negative effect on soft tissue visibility and uniformity of CBCT scans. Antiscatter grids (ASG) are used in the field of diagnostic radiography to mitigate the scatter. They usually do increase the contrast of the scan, but simultaneously increase the noise. Therefore, and considering other scatter mitigation mechanisms present in a CBCT scanner, the applicability of ASGs with aluminum interspacing for a wide range of imaging conditions has been inconclusive in previous studies. In recent years, grids using fiber interspacers have appeared, providing grids with higher scatter rejection while maintaining reasonable transmission of primary radiation. The purpose of this study was to evaluate the impact of one such grid on CBCT image quality. Methods: The grid used (Philips Medical Systems) had ratio of 21:1, frequency 36 lp/cm, and nominal selectivity of 11.9. It was mounted on the kV flat panel detector of an Elekta Synergy linear accelerator and tested in a phantom and a clinical study. Due to the flex of the linac and presence of gridline artifacts an angle dependent gain correction algorithm was devised to mitigate resulting artifacts. Scan reconstruction was performed using XVI4.5 augmented with inhouse developed image lag correction and Hounsfield unit calibration. To determine the necessary parameters for Hounsfield unit calibration and software scatter correction parameters, the Catphan 600 (The Phantom Laboratory) phantom was used. Image quality parameters were evaluated using CIRS CBCT Image Quality and Electron Density Phantom (CIRS) in two different geometries: one modeling head and neck and other pelvic region. Phantoms were acquired with and without the grid and reconstructed with and without software correction which was adapted for the different acquisition scenarios. Parameters used in the phantom study weret{sub cup} for nonuniformity and contrast-to-noise ratio (CNR) for soft tissue visibility. Clinical scans were evaluated in an observer study in which four experienced radiotherapy technologists rated soft tissue visibility and uniformity of scans with and without the grid. Results: The proposed angle dependent gain correction algorithm suppressed the visible ring artifacts. Grid had a beneficial impact on nonuniformity, contrast to noise ratio, and Hounsfield unit accuracy for both scanning geometries. The nonuniformity reduced by 90% for head sized object and 91% for pelvic-sized object. CNR improved compared to no corrections on average by a factor 2.8 for the head sized object, and 2.2 for the pelvic sized phantom. Grid outperformed software correction alone, but adding additional software correction to the grid was overall the best strategy. In the observer study, a significant improvement was found in both soft tissue visibility and nonuniformity of scans when grid is used. Conclusions: The evaluated fiber-interspaced grid improved the image quality of the CBCT system for broad range of imaging conditions. Clinical scans show significant improvement in soft tissue visibility and uniformity without the need to increase the imaging dose.

60 APPLIED LIFE SCIENCES↗