Search NASA⌕ Search

SEARCH · Search NASA

Results for “active source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Structural and functional characterization of TRI3 trichothecene 15-O-acetyltransferase from Fusarium sporotrichioides

Fusarium head blight is a devastating disease of cereal crops whose worldwide incidence is increasing and at present there is no satisfactory way of combating this pathogen or its associated toxins. There is a wide variety of trichothecene mycotoxins and they all contain a 12,13-epoxytrichothecene skeleton but differ in their substitutions. Indeed, there is considerable variation in the toxin profile across the numerous Fusarium species that has been ascribed to differences in the presence or absence of biosynthetic enzymes and their relative activity. This article addresses the source of differences in acetylation at the C15 position of the trichothecene molecule. Here, we present the in vitro structural and biochemical characterization of TRI3, a 15-O-trichothecene acetyltransferase isolated from F. sporotrichioides and the 'in vivo' characterization of Deltatri3 mutants of deoxynivalenol (DON) producing F. graminearum strains. A kinetic analysis shows that TRI3 is an efficient enzyme with the native substrate, 15-decalonectrin, but is inactive with either DON or nivalenol. The structure of TRI3 complexed with 15-decalonectrin provides an explanation for this specificity and shows that Tri3 and Tri101 (3-O-trichothecene acetyltransferase) are evolutionarily related. The active site residues are conserved across all sequences for TRI3 orthologs, suggesting that differences in acetylation at C15 are not due to differences in Tri3. The tri3 deletion mutant shows that acetylation at C15 is required for DON biosynthesis even though DON lacks a C15 acetyl group. The enzyme(s) responsible for deacetylation at the 15 position of the trichothecene mycotoxins have not been identified.

60 APPLIED LIFE SCIENCES↗

Southeast Carbon Sequestration Partnership (SECARB) Phase III Anthropogenic Test at Citronelle Field, Mobile Co., AL Surface and Shallow Subsurface Monitoring

The Southeast Carbon Sequestration Partnership Phase III Anthropogenic Test at Citronelle Field is one of the United States’ largest demonstrations of CO 2 capture, transportation, injection, storage and monitoring using CO 2 derived from a coal-fired electric generating unit. This report summarizes the background and initial injection phase groundwater and soil flux monitoring results. The purpose of the groundwater monitoring program, as prescribed in the Underground Injection Control (UIC) permits is to assure that the project’s activities do not harm Underground Sources of Drinking Water (USDWs). In particular, the objective of the program is to monitor for the release of injected CO2 into groundwater aquifers at the project site. Three shallow USDW monitoring wells were installed as part of the groundwater monitoring program. In addition, a water supply well located near the project’s deep characterization well was utilized for monitoring. Seventeen metals, general chemistry and field parameters (e.g. pH, specific conductance, turbidity) were sampled three times prior to injection and quarterly during the injection period to date. Changes in groundwater geochemistry potentially attributable to a release of carbon dioxide into the USDW from the injection activities are decreasing pH and increasing TIC. The change in pH may also accompany the mobilization of certain metals within the groundwater, but the changes are likely site-specific, based on the natural aquifer mineralogy (Wilkin and Diguilio, 2010). At this time, no downward trends for pH and increasing trends for TIC have been statistically determined in the monitor wells. Valid detections exceeding both the UIC discharge limit and the range of background concentrations observed as of the N=11 event include: Exceedance of the UIC permit discharge limit of manganese at D-9-7 MW-2S and D-9-9 MW-1, and exceedance of the UIC permit discharge limit of iron at D-9-9 MW-1. In addition, a statistically significant increase of barium and manganese has been observed at D-9-9 MW-1. However, Additional lines of evidence (namely, expected shifts in TIC or pH, per the research cited above) to interpret the cause (e.g., potential carbon dioxide influence) of the statistically determined exceedances and/or increases are absent at this time. Quarterly groundwater sampling and analysis will continue throughout the project. The UIC permit requires that soil CO 2 flux shall be monitored at the land surface at the injection site and at nearby locations. Twelve locations were chosen for surveys including a mix of near wellbore and offset locations. To date, 24 surveys have taken place with 12 occurring prior to the onset of injection operations in August 2012. Soil CO 2 flux appears to positively covary with soil temperature. A notably high soil CO 2 flux value (21 µmol/m 2 /sec) was observed from the D-9-9 #2 chamber location during sampling event #24 (9/24/2014). As a result of this finding, the frequency of soil CO 2 flux monitoring events will be increased to twice-monthly until this anomaly can be confirmed or determined to be an outlier. Soil CO 2 flux monitoring will continue for the duration of the project.

01 COAL, LIGNITE, AND PEAT↗

An electrochemical investigation of interfacial electron uptake by the sulfur oxidizing bacterium Thioclava electrotropha ElOx9

Extracellular electron transfer (EET) allows microbes to acquire energy from solid state electron acceptors and donors, such as environmental minerals. Here, this process can also be harnessed at electrode interfaces in bioelectrochemical technologies including microbial fuel cells, microbial electrosynthesis, bioremediation, and wastewater treatment. Improving the performance of these technologies will benefit from a better fundamental understanding of EET in diverse microbial systems. While the mechanisms of outward (i.e. microbe-to-anode) EET is relatively well characterized, specifically in a few metal-reducing bacteria, the reverse process of inward EET from redox-active minerals or cathodes to bacteria remains poorly understood. This knowledge gap stems, at least partly, from the lack of well-established model organisms and general difficulties associated with laboratory studies in existing model systems. Recently, a sulfur oxidizing marine microbe, Thioclava electrotropha ElOx9, was demonstrated to perform electron uptake from cathodes. However, a detailed analysis of the electron uptake pathways has yet to be established, and electrochemical characterization has been limited to aerobic conditions. Here, we report a detailed amperometric and voltammetric characterization of ElOx9 cells coupling cathodic electron uptake to reduction of nitrate as the sole electron acceptor, even in the absence of any added inorganic carbon source. By comparing this cellular activity to spent media controls and using medium exchange experiments, we demonstrate that one of the pathways by which ElOx9 facilitates inward EET is by a direct-contact mechanism through a redox center with a formal potential of -94 mV vs SHE, rather than soluble intermediate electron carriers. In addition to the implications for understanding microbial sulfur oxidation in marine environments, this study highlights the potential for ElOx9 to serve as a convenient and readily culturable model organism for understanding the molecular mechanisms of inward EET.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of Traceable Solid Mock 131 I Phantoms Used in an International SPECT Image Quantification Comparison

The International Atomic Energy Agency (IAEA) has organized an international comparison to assess Single Photon Emission Computed Tomography (SPECT) image quantification capabilities in 12 countries. Iodine-131 was chosen as the radionuclide for the comparison because of its wide use around the world, but for logistical reasons solid 133 Ba sources were used as a long-lived surrogate for 131 I. For this study, we designed a set of solid cylindrical sources so that each site could have a set of phantoms (having nominal volumes of 2 mL, 4 mL, 6 mL, and 23 mL) with traceable activity calibrations so that the results could be properly compared. We also developed a technique using two different detection methods for individually calibrating the sources for 133 Ba activity based on a National standard. This methodology allows for the activity calibration of each 133 Ba source with a standard uncertainty on the activity of 1.4 % for the high-level 2-, 4-, and 6-mL sources and 1.7 % for the lower-level 23 mL cylinders. This level of uncertainty allows for these sources to be used for the intended comparison exercise, as well as in other SPECT image quantification studies.

47 OTHER INSTRUMENTATION↗

Portrait and Classification of Individual Haze Particulates

Haze (known as “Mai” in Chinese) threatens the health of billions of people across the globe. To begin solving this problem without severely slowing down the economy, one has to mechanistically and geographically pinpoint the sources of these pollutants, the key of which is to thoroughly characterize and fingerprint the particulates. Here we present a broad survey and classification of thousands of individual airborne particu-lates by using the Scanning Electron Microscope (SEM) to measure their diverse mor-phologies and chemistries, which could eventually be organized into a “haze finger-print database”. For instance, one collection in Xi’an City, China during March-April 2014 yielded 494 airborne particulates that settled on silicon wafers placed outside the window of a 3rd floor office. These 494 particulates were manually imaged with high resolution (down to 2 nm), elementally mapped using Energy-dispersive X-ray Spec-troscopy (EDS), and were identified and categorized into presumed source classes such as construction activities (Ca, Al, Si-O), coal burning (sulfates), biologic (pollen, bac-teria), automotive, mining, steel making, and etc. About 20% of the particulates have mysterious origins, as it is still unclear how they were formed, and a fraction of them contained clearly hazardous elements such as lead and chromium. For future work, we propose using unmanned aerial vehicles with a special “rolling film” substrate that can autonomously collect airborne particulates, a customized SEM auto-imaging system, and machine learning software to establish an online open-access database. The end goal would be to monitor and analyze the particulate pollutants that are pumped into our atmosphere every day, and precisely track down their sources so we can better model and police the quality of the air around us.

54 ENVIRONMENTAL SCIENCES↗

Configuration and impurity quantification of AmLi sources using radiography and gamma spectroscopy

This paper presents the non-destructive assay of two AmLi sources used for detector characterization and active interrogation at PNNL, identified as MRC-101 and MRC-103. First, a detailed description of the internal configuration of 2724-BT encapsulated MRC sources is established. X-ray radiographs of the AmLi sources are reported for the first time to verify the dimensions and orientation of the encapsulation. Notably, a density variation was observed as a contrast change across the height of the source cavities. Contrary to commonly made assumptions in literature, it is indirectly observed that the AmLi source/target material only occupies a portion of the source cavity. The intensity of the prompt gamma-rays resulting from the inelastic scatter of alpha particles on 7Li was used to calculate the mass ratios of LiH:AmO2. The gamma-ray spectra revealed the presence of numerous impurities in both source and target material (243Am, 237Np, 154Eu, 23Na, and 9Be). Neutron-gamma production ratios were applied to the intensity of the Doppler-broadened peaks from alpha-induced reactions with 7Li, 9Be, and 23Na to calculate neutron rates for both sources. A neutron/alpha production yield (derived in this work) was then related to the atomic concentration of these isotopes to find the approximate masses within each source. Ultimately, the AmLi source density was estimated with prompt gamma analysis based on partial source volumes as 0.45±0.08 g/cm^3.

DTRA, AmLi, neutron↗

Production of electron cyclotron resonance plasma by using multifrequencies microwaves and active beam profile control on a large bore electron cyclotron resonance ion source with permanent magnets

A new concept on magnetic field with all magnets on plasma production and confinement has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure. The magnetic field configuration is constructed by a pair of magnets assembly, i.e., comb-shaped magnet which cylindrically surrounds the plasma chamber. The resonance zones corresponding to the fundamental ECR for 2.45 GHz and 11-13 GHz frequencies are constructed at different positions. The profiles of the plasma parameters in the ECR ion source are different from each frequency of microwave. Large bore extractor is set at the opposite side against the microwave feeds. It is found that differences of their profiles also appear at those of ion beam profiles. We conducted to launch simultaneously multiplex frequencies microwaves controlled individually, and tried to control the profiles of the plasma parameters and then those of extracted ion beam.

43 PARTICLE ACCELERATORS↗

Multi-Frequency Microwaves Plasma Production for Active Profile Control of Ion Beams on a Large Bore ECR Ion Source with Permanent Magnets

A new concept on magnetic field of plasma production and confinement by using permanent magnets, i.e. cylindrically comb-shaped magnets, has been proposed to enhance efficiency of an electron cyclotron resonance (ECR) plasma for broad and dense ion beam source under the low pressure and also the low microwave power. The resonance zones corresponding to the fundamental ECR for 2.45 GHz and 11-13 GHz frequency are constructed at different positions. The profiles of the plasma parameters in the ECR ion source are different from each frequency of microwave. Large bore extractor is set at the opposite side against the microwave feeds. It is found that differences of their profiles also appear at those of ion beam profiles. We conducted to launch simultaneously multiplex frequency microwaves controlled individually, and tried to control the profiles of the plasma parameters and then those of extracted ion beam.

43 PARTICLE ACCELERATORS↗

Radiation Doses to Members of the U.S. Population from Ubiquitous Radionuclides in the Body: Part 2, Methods and Dose Calculations

This paper is part two of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludes intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Assumptions about equilibrium with long-lived parents are made for the 28 other radionuclides in these series lacking data. This paper describes the methods developed to group the collected data into source regions described in the Radiation Dose Assessment Resource (RADAR) dosimetric methodology. Methods for converting the various units of data published over 50 years into a standard form are developed and described. Often, meaningful values of uncertainty of measurements were not published so that variability in data sets is confounded with measurement uncertainty. A description of the methods developed to estimate variability is included in this paper. The data described in part one are grouped by gender and age to match the RADAR dosimetric phantoms. Within these phantoms, concentration values are grouped into source tissue regions by radionuclide, and they are imputed for source regions lacking tissue data. Radionuclide concentrations are then imputed for other phantoms’ source regions with missing concentration values, and the uncertainties of the imputed values are increased. The content concentrations of hollow organs are calculated, and activities are apportioned to the bone source regions using assumptions about each radionuclide’s bone-seeking behavior. The data sets are then ready to be used to estimate equivalent doses to target tissues from these source regions. The target tissues are then mapped to lists of tissues with International Commission on Radiation Protection (ICRP) tissue weighting factors, or they are mapped to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue weighting factors recommended in 1977, 1990, and 2007, are calculated from tissue and organ equivalent doses.

59 BASIC BIOLOGICAL SCIENCES↗

STUDYING FAINT ULTRA-HARD X-RAY EMISSION FROM AGN IN GOALS LIRGS WITH SWIFT/BAT

We present the first analysis of the all-sky Swift Burst Alert Telescope (BAT) ultra-hard X-ray (14-195 keV) data for a targeted list of objects. We find that the BAT data can be studied at three-times-fainter limits than in previous blind detection catalogs based on prior knowledge of source positions and using smaller energy ranges for source detection. We determine the active galactic nucleus (AGN) fraction in 134 nearby (z < 0.05) luminous infrared galaxies (LIRGs) from the GOALS sample. We find that LIRGs have a higher detection frequency than galaxies matched in stellar mass and redshift at 14-195 keV and 24-35 keV. In agreement with work at other wavelengths, the AGN detection fraction increases strongly at high IR luminosity with half of the high-luminosity LIRGs (50%, 6/12, log L{sub IR}/L{sub Sun} > 11.8) detected. The BAT AGN classification shows 97% (37/38) agreement with Chandra and XMM-Newton AGN classification using hardness ratios or detection of an iron K{alpha} line. This confirms our statistical analysis and supports the use of the Swift/BAT all-sky survey to study fainter populations of any category of sources in the ultra-hard X-ray band. BAT AGNs in LIRGs tend to show higher column densities with 40% {+-} 9% showing 14-195 keV/2-10 keV hardness flux ratios suggestive of high or Compton-thick column densities (log N{sub H} > 24 cm{sup -2}), compared to only 12% {+-} 5% of non-LIRG BAT AGNs. We also find that using specific energy ranges of the BAT detector can yield additional sources over total band detections with 24% (5/21) of detections in LIRGs at 24-35 keV not detected at 14-195 keV.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EVOLUTION AND ENVIRONMENTS OF X-RAY EMITTING ACTIVE GALACTIC NUCLEI IN HIGH-REDSHIFT LARGE-SCALE STRUCTURES

We use deep Chandra imaging and an extensive optical spectroscopy campaign on the Keck 10 m telescopes to study the properties of X-ray point sources in two isolated X-ray-selected clusters, two superclusters, and one 'supergroup' at redshifts of z {approx} 0.7-0.9. We first study X-ray point sources using the statistical measure of cumulative source counts, finding that the measured overdensities are consistent with previous results, but we recommend caution in overestimating the precision of the technique. Optical spectroscopy of objects matched to X-ray point sources confirms a total of 27 active galactic nuclei (AGNs) within 5 structures, and we find that their host galaxies tend to be located away from dense cluster cores. More than 36% of the host galaxies are located in the 'green valley' on a color-magnitude diagram, which suggests they are a transitional population. Based on analysis of [O II] and H{delta} line strengths, the average spectral properties of the AGN host galaxies in all structures indicate either ongoing star formation or a starburst within {approx}1 Gyr, and that the host galaxies are younger than the average galaxy in the parent population. These results indicate a clear connection between starburst and nuclear activity. We use composite spectra of the spectroscopically confirmed members in each structure (cluster, supergroup, or supercluster) to separate them based on a measure of the overall evolutionary state of their constituent galaxies. We define structures as having more evolved populations if their average galaxy has lower EW([O II]) and EW(H{delta}). The AGNs in the more evolved structures have lower rest-frame 0.5-8 keV X-ray luminosities (all below 10{sup 43.3} erg s{sup -1}) and longer times since a starburst than those in the unevolved structures, suggesting that the peak of both star formation and AGN activity has occurred at earlier times. With the wide range of evolutionary states and time frames in the structures, we use our results to analyze the evolution of X-ray AGNs and evaluate potential triggering mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Bistability and hysteresis in the emergence of pulses in microstrip Gunn-diode circuits

We develop time-domain simulations of microwave and THz radiation sources built as arrays of active devices when the radiation wavelength is small as compared to spacing between electronic components. We pursue an approach when the system is represented by equations with time-delay feedback that could generate chaos and other forms of complicated dynamics. The approach simplifies simulations of ultra-wideband effects and exceeds capabilities of frequency-domain methods. As a model case, we simulated a microstrip circuit with Gunn diode and a remote resonator emitting the radiation towards infinity. We observed the emergence of either the continuous waves or the trains of high-frequency pulses depending on the bias conditions. We found bistability and hysteresis in the onset of different oscillation modes that depends on the way of driving the bias voltage into the domain of instability of the given system. The results would allow one to improve the design of THz radiation sources with time-delay coupling between components.

36 MATERIALS SCIENCE↗

Diffuse γ-ray emission from galactic pulsars

Millisecond pulsars (MSPs) are old fast-spinning neutron stars that represent the second most abundant source population discovered by the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope (Fermi). As guaranteed γ-ray emitters, they might contribute non-negligibly to the diffuse emission measured at high latitudes by Fermi-LAT (i.e., the Isotropic Diffuse γ-Ray Background (IDGRB)), which is believed to arise from the superposition of several components of galactic and extragalactic origin. Additionally, γ-ray sources also contribute to the anisotropy of the IDGRB measured on small scales by Fermi-LAT. In this manuscript we aim to assess the contribution of the unresolved counterpart of the detected MSPs population to the IDGRB and the maximal fraction of the measured anisotropy produced by this source class. To this end, we model the MSPs' spatial distribution in the Galaxy and the γ-ray emission parameters by considering observational constraints coming from the Australia Telescope National Facility pulsar catalog and the Second Fermi-LAT Catalog of γ-ray pulsars. By simulating a large number of MSP populations through a Monte Carlo simulation, we compute the average diffuse emission and the anisotropy 1σ upper limit. We find that the emission from unresolved MSPs at 2 GeV, where the peak of the spectrum is located, is at most 0.9% of the measured IDGRB above 10° in latitude. The 1σ upper limit on the angular power for unresolved MSP sources turns out to be about a factor of 60 smaller than Fermi-LAT measurements above 30°. Our results indicate that this galactic source class represents a negligible contributor to the high-latitude γ-ray sky and confirm that most of the intensity and geometrical properties of the measured diffuse emission are imputable to other extragalactic source classes (e.g., blazars, misaligned active galactic nuclei, or star-forming galaxies). Nevertheless, because MSPs are more concentrated toward the galactic center, we expect them to contribute significantly to the γ-ray diffuse emission at low latitudes. Because, along the galactic disk, the population of young pulsars overcomes in number that of MSPs, we compute the γ-ray emission from the whole population of unresolved pulsars, both young and millisecond, in two low-latitude regions: the inner Galaxy and the galactic center.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature characteristics of epitaxially grown InAs quantum dot micro-disk lasers on silicon for on-chip light sources

Temperature characteristics of optically pumped micro-disk lasers (MDLs) incorporating InAs quantum dot active regions are investigated for on-chip light sources. The InAs quantum dot MDLs were grown on V-groove patterned (001) silicon, fully compatible with the prevailing complementary metal oxide-semiconductor technology. By combining the high-quality whispering gallery modes and 3D confinement of injected carriers in quantum dot micro-disk structures, we achieved lasing operation from 10 K up to room temperature under continuous optical pumping. Temperature dependences of the threshold, lasing wavelength, slope efficiency, and mode linewidth are examined. An excellent characteristic temperature T{sub o} of 105 K has been extracted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-RAY EMISSION AND CORONA OF THE YOUNG INTERMEDIATE-MASS BINARY theta{sup 1} Ori E

theta{sup 1} Ori E is a young, moderate mass binary system, a rarely observed case of spectral-type G-giants of about 3 solar masses, which are still collapsing toward the main sequence, where they presumably become X-ray faint. We have obtained high-resolution X-ray spectra with Chandra and find that the system is very active and similar to coronal sources, having emission typical of magnetically confined plasma. It has a broad temperature distribution with a hot component and significant high energy continuum; narrow emission lines from H- and He-like ions, as well as a range of Fe ions, and relative luminosity, L{sub x} /L{sub bol} = 10{sup -3}, at the saturation limit. Density, while poorly constrained, is consistent with the low density limits, our upper limits being n{sub e} < 10{sup 13} cm{sup -3} for Mg XI and n{sub e} < 10{sup 12} cm{sup -3} for Ne IX. Coronal elemental abundances are sub-solar, with Ne being the highest at about 0.4 times solar. We find a possible trend in Trapezium hot plasmas toward low relative abundances of Fe, O, and Ne, which is hard to explain in terms of the dust depletion scenarios of low-mass young stars. Variability was unusually low during our observations relative to other coronally active stars. Qualitatively, the emission is similar to post-main-sequence G-stars. Coronal structures could be compact or comparable to the dimensions of the stellar radii. From comparison to X-ray emission from similar mass stars at various evolutionary epochs, we conclude that the X-rays in theta{sup 1} Ori E are generated by a convective dynamo, present during contraction, but which will vanish during the main-sequence epoch possibly to be resurrected during post-main-sequence evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopy identification performance enhancement of a novel CZT/CsI hybrid system

New hybrid spectroscopic systems directly combine spectra from detectors with very different energy resolutions, accommodating standard analyses of the output hybrid spectrum. Simulations of a hybrid system consisting of a 2 or 4 cm{sup 3} cadmium zinc telluride detector combined with a 32.8 cm{sup 3} CsI(Tl) were evaluated for identification performance. 29 nuclides of interest for security applications were simulated as singles and unique pairs, producing 435 spectral simulations at live times of 3, 10, 30, 100 and 300 seconds. The nuclides were modeled as point sources at 25 cm with activities that provide an interesting range of statistical significance for the range of counting times. Standard nuclide identification analyses were applied to the component detectors as well as the hybrid combination. Tallies of the results were used to calculate true and false identification rates. The hybrid system was shown to provide an identification performance benefit, consistently achieving performances closest to ideal relative to the separate component detectors. The hybrid approach enables the consideration of a greater variety of measurement system solutions in terms of cost and performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗