Neutron field parameter measurements on the JET tokamak by means of super-heated fluid detectors

The neutron field parameters (fluence and energy distribution) at a specific location outside the JET Torus Hall have been measured by means of super-heated fluid detectors (or 'bubble detectors') in combination with an independent, time-of-flight, technique. The bubble detector assemblies were placed at the end of a vertical line of sight at about 16 m from the tokamak mid plane. Spatial distributions of the neutron fluence along the radial and toroidal directions have been obtained using two-dimensional arrays of bubble detectors. Using a set of three bubble detector spectrometers the neutron energy distribution was determined over a broad energy range, from about 10 keV to above 10 MeV, with an energy resolution of about 30% at 2.5 MeV. The very broad energy response allowed for the identification of energy features far from the main fusion component (around 2.45 MeV for deuterium discharges).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors

The authors report on the imaging capabilities of a mammographic system demonstrator based on GaAs pixel detectors operating in single photon counting (SPC) mode. The system imaging performances have been assessed by means of the transfer functions: The modulation transfer function (MTF), the normalized noise power spectrum, and the detective quantum efficiency (DQE) have been measured following the guidelines of the IEC 62220-1-2 protocol. The transfer function analysis has shown the high spatial resolution capabilities of the GaAs detectors. The MTF calculated at the Nyquist frequency (2.94 cycles/mm) is indeed 60%. The DQE, measured with a standard mammographic beam setup (Mo/Mo, 28 kVp, with 4 mm Al added filter) and calculated at zero frequency, is 46%. Aiming to further improve the system's image quality, the authors investigate the DQE limiting factors and show that they are mainly related to system engineering. For example, the authors show that optimization of the image equalization procedure increases the DQE(0) up to 74%, which is better than the DQE(0) of most clinical mammographic systems. The authors show how the high detection efficiency of GaAs detectors and the noise discrimination associated with the SPC technology allow optimizing the image quality in mammography. In conclusion, the authors propose technological solutions to exploit to the utmost the potentiality of GaAs detectors coupled to SPC electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How accurately can 21 cm tomography constrain cosmology?

There is growing interest in using 3-dimensional neutral hydrogen mapping with the redshifted 21 cm line as a cosmological probe. However, its utility depends on many assumptions. To aid experimental planning and design, we quantify how the precision with which cosmological parameters can be measured depends on a broad range of assumptions, focusing on the 21 cm signal from 6<z<20. We cover assumptions related to modeling of the ionization power spectrum, to the experimental specifications like array layout and detector noise, to uncertainties in the reionization history, and to the level of contamination from astrophysical foregrounds. We derive simple analytic estimates for how various assumptions affect an experiment's sensitivity, and we find that the modeling of reionization is the most important, followed by the array layout. We present an accurate yet robust method for measuring cosmological parameters that exploits the fact that the ionization power spectra are rather smooth functions that can be accurately fit by 7 phenomenological parameters. We find that for future experiments, marginalizing over these nuisance parameters may provide constraints almost as tight on the cosmology as if 21 cm tomography measured the matter power spectrum directly. A future square kilometer array optimized for 21 cm tomography could improve the sensitivity to spatial curvature and neutrino masses by up to 2 orders of magnitude, to {delta}{omega}{sub k}{approx_equal}0.0002 and {delta}m{sub {nu}}{approx_equal}0.007 eV, and give a 4{sigma} detection of the spectral index running predicted by the simplest inflation models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasmonics-enhanced photoconductive terahertz detector pumped by Ytterbium-doped fiber laser

We present a photoconductive terahertz detector operating at the 1 µm wavelength range at which high-power and compact Ytterbium-doped femtosecond fiber lasers are available. The detector utilizes an array of plasmonic nanoantennas to provide sub-picosecond transit time for the majority of photo-generated carriers to enable high-sensitivity terahertz detection without using a short-carrier-lifetime substrate. By using a high-mobility semiconductor substrate and preventing photocarrier recombination, the presented detector offers significantly higher sensitivity levels compared with previously demonstrated broadband photoconductive terahertz detectors operating at the 1 µm wavelength range. We demonstrate pulsed terahertz detection over a 4 THz bandwidth with a record-high signal-to-noise ratio of 95 dB at an average terahertz radiation power of 6.8 µW, when using an optical pump power of 30 mW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time signal detection for Cyclotron Radiation Emission Spectroscopy measurements using antenna arrays

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40 meV, requiring a large supply of tritium atoms stored in a multi-cubic meter detector volume. Antenna arrays are one potential technology compatible with an experiment of this scale, but the capability of an antenna-based CRES experiment to measure the neutrino mass depends on the efficiency of the signal detection algorithms. Here, in this paper, we develop efficiency models for three signal detection algorithms and compare them using simulations from a prototype antenna-based CRES experiment as a case-study. The algorithms include a power threshold, a matched filter template bank, and a neural network based machine learning approach, which are analyzed in terms of their average detection efficiency and relative computational cost. It is found that significant improvements in detection efficiency and, therefore, neutrino mass sensitivity are achievable, with only a moderate increase in computation cost, by utilizing either the matched filter or machine learning approach in place of a power threshold, which is the baseline signal detection algorithm used in previous CRES experiments by Project 8.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-FF-T-469: Energy Spectra Reconstruction From Beta Emitters: A Study of the Sr-90/Y-90 Case

Purpose: Reconstruction of the energy spectrum of a 90Sr/90Yradioactive source for low dose (~1Gy) radiation biology experiments. Method and Materials:Electrons originated from a 25 {micro}Ci 90Sr/90Yradioactive source were recently used in radio-biology experiments to study the response of cancer cells to low dose irradiation (~1Gy). The beam was separated into individual energies using a dipole magnet, the number of exited electronsmeasured by a scintillating fiber based detector and the dose obtained using double-layered EBT films. The dipole was constructed from two 5.08 x 5.08 x 2.54 cm{sup 3}permanent magnets separated by a distance of 2 cm and having a maximum field of about 5 kG at the center. The beam entered the magnet through a 1 cm diameter, 0.5 cm thick leaded glass collimator. The detector was an array of 16 blue shifted 1 mm thick scintillating fibers. A realistic Geant4 simulation was used to account for the energy loss while electrons propagate throughout the system. The incident energy spectrum was generated from the NIST-logft calculation. Results: The data was first compared with measurements using a pancake frisker detector for an overall general assessment of the data quality, giving an agreement to within 15%. The average deviation of the data/simulation ratio is {+-}2.5%. A comparison between the measured and simulated mean energies gives an agreement to within 1{sigma} (less than 0.3%). Conclusion: The simple system developed for this work can serve as a mean for an efficient way to accurately reconstruct the energy distribution of charged particle emitters as well as to assess expected dose delivery to biological systems. Such data can also be used to benchmark low energy physics processes implemented in simulation tools for medical physics purpose.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{beta}- and {gamma}-spectroscopy study of {sup 119}Pd and {sup 119}Ag

Neutron-rich Pd-119 nuclei were produced in fission of natural uranium, induced by 25-MeV protons. Fission fragments swiftly extracted with the Ion Guide Isotope Separation On-Line method were mass separated using a dipole magnet and a Penning trap, providing mono-isotopic samples of Pd-119. Their beta(-) decay was measured with gamma gamma- and beta gamma-spectroscopy methods using low-energy germanium detectors and a thin plastic scintillator. Two distinct nuclear-level structures were observed in Ag-119, based on the 1/2(-) and 7/2(+) isomers reported previously. The beta(-)decay work was complemented by a prompt-gamma study of levels in Ag-119 populated in spontaneous fission of (252)cf, performed using the Gammasphere array of germanium detectors. Contrary to previous suggestions, our data show that the 1/2(-) isomer is located below the 7/2(+) isomer and is proposed as a new ground state of Ag-119 with the 7/2(+) isomer excitation energy determined to be 33.4 keV. Our data indicate that there are two beta unstable isomers in Pd-119, a proposed ground state of Pd-119 with tentative spin 1/2(-) or 3/2(+) and a half-life of 0.88 s and the other one about 350 keV above, having spin (11/2(-)) and a half-life of 0.85 s. The higher-energy isomer probably decays to the 1/2(-) or 3/2(+) ground state via a gamma cascade comprising 18.7-219.8-X-keV transitions. The unobserved isomeric transition with energy X approximate to 100 keV probably has an E3 multipolarity. Its hindrance factor is significantly lower than for analogous E3 isomeric transitions in lighter Pd isotopes, suggesting an oblate deformation of levels in Pd-119. Oblate configurations in Ag-119 are discussed also.

Kurpeta, J↗

Multi-Channel Integrated Circuits For Use In Research With Radioactive Ion Beams

The Integrated Circuits Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has been collaborating over the past several years with the Nuclear Reactions Group at Washington University (WU) on the development of a family of custom, multi-channel Integrated Circuits (ICs). To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip known as HINP16C (Heavy Ion Nuclear Physics--16 Channel). The second chip, christened PSD8C (Pulse Shape Discrimination--8 Channel), was designed to logically complement (in terms of detector types) the HINP16C chip. The HINP16C chip, for use with solid-state detectors, produces sparsified analog pulse trains for both linear (pulse height) and timing (relative to an external reference) signals. A shaper and peak detector are implemented in the linear branch, and a pseudo Constant-Fraction Discriminator (CFD) and Time-to-Voltage Converter (TVC) are implemented in the logic/timing branch. The internal and external gain options make the chip suitable for use in a wide variety of applications. PSD8C greatly simplifies the pulse-processing electronics needed for large arrays of scintillation detectors. As the PSD8C employs user-controlled, multi-region charge integration, particle identification is inherent in the design. Each of the three pulse-height sub-channels consists of a gated integrator with eight programmable charging rates and an externally programmable gate generator that defines the start (with 4 time ranges) and the width (with 4 time ranges) of the gate, relative to an external discriminator signal. Moreover, each channel on the chip also contains a TVC. This paper describes the design, capabilities, and features of the HINP16C and PSD8C ICs along with a description of how the chips are being used. It also discusses modifications and enhancements which have been made to both chips and their associated prototypical systems in order to improve ease of use and increase performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Technical Report for Award DE-FG02-05ER41389 A New Electrostatically-Focused, UV HPD for Liquid Xenon: A Direct Comparison with APD, PMT, SiPM in an Integrated Database

Within the scope of the project, a LXe detector and associated gas handling and purification system were set up to study the response of various photodetectors to the VUV Xe light. In particular we tested an Advanced Photonix Large Area Avalanche Photodiode (APD), Silicon Photomultipliers (SiPMs) from two different sources and an Hamamtsu Photonics APD. As part of the XENON Dark Matter project, sponsored by the National Science Foundation, we have accumulated independent knowledge of the response of compact metal channel photomultipliers. At this stage, we conclude that the last are far superior in terms of reliability and performance in a LXe detector environment. More studies are needed with APDs and SiPMs in LXe, taking advantage of the improved performance of these sensors with time. We could not test a hybrid PMT (HPD) since the only available unit on loan from one manufacturer lacked the mechanical stability and was packaged in a form not compatible with LXe purity requirements. Meanwhile, within the XENON collaboration, we are developing with Hamamatsu a hybrid PMT which is named QUPID (Quartz Photon Intensifying Detector) which promises to solve the problems of radioactivity and purity encountered with previous HPDs. We attach to this report two papers which summarize in detail the experimental st-ups, procedures and results obtained with different APDs and SiPMs operated in LXe. We continue our investigations of APDs in view of their potential appication in large arrays for LXe detectors. We intend to publish the results once we complete tests of newly acquired Hamamatsu APDs.

02 PETROLEUM↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Large Area Telescope on the Fermi Gamma-ray Space Telescope Mission

The Large Area Telescope (Fermi/LAT, hereafter LAT), the primary instrument on the Fermi Gamma-ray Space Telescope (Fermi) mission, is an imaging, wide field-of-view (FoV), high-energy {gamma}-ray telescope, covering the energy range from below 20 MeV to more than 300 GeV. The LAT was built by an international collaboration with contributions from space agencies, high-energy particle physics institutes, and universities in France, Italy, Japan, Sweden, and the United States. This paper describes the LAT, its preflight expected performance, and summarizes the key science objectives that will be addressed. On-orbit performance will be presented in detail in a subsequent paper. The LAT is a pair-conversion telescope with a precision tracker and calorimeter, each consisting of a 4 x 4 array of 16 modules, a segmented anticoincidence detector that covers the tracker array, and a programmable trigger and data acquisition system. Each tracker module has a vertical stack of 18 (x, y) tracking planes, including two layers (x and y) of single-sided silicon strip detectors and high-Z converter material (tungsten) per tray. Every calorimeter module has 96 CsI(Tl) crystals, arranged in an eight-layer hodoscopic configuration with a total depth of 8.6 radiation lengths, giving both longitudinal and transverse information about the energy deposition pattern. The calorimeter's depth and segmentation enable the high-energy reach of the LAT and contribute significantly to background rejection. The aspect ratio of the tracker (height/width) is 0.4, allowing a large FoV (2.4 sr) and ensuring that most pair-conversion showers initiated in the tracker will pass into the calorimeter for energy measurement. Data obtained with the LAT are intended to (1) permit rapid notification of high-energy {gamma}-ray bursts and transients and facilitate monitoring of variable sources, (2) yield an extensive catalog of several thousand high-energy sources obtained from an all-sky survey, (3) measure spectra from 20 MeV to more than 50 GeV for several hundred sources, (4) localize point sources to 0.3-2 arcmin, (5) map and obtain spectra of extended sources such as SNRs, molecular clouds, and nearby galaxies, (6) measure the diffuse isotropic {gamma}-ray background up to TeV energies, and (7) explore the discovery space for dark matter.

Astrophysics,ASTRO↗

Targeting ultra-high energy neutrinos with the ARIANNA experiment

The measurement of ultra-high energy (UHE) neutrinos (E > 10 16 eV) opens a new field of astronomy with the potential to reveal the sources of ultra-high energy cosmic rays especially if combined with observations in the electromagnetic spectrum and gravitational waves. The ARIANNA pilot detector explores the detection of UHE neutrinos with a surface array of independent radio detector stations in Antarctica which allows for a cost-effective instrumentation of large volumes. Twelve stations are currently operating successfully at the Moore's Bay site (Ross Ice Shelf) in Antarctica and at the South Pole. In this work, we will review the current state of ARIANNA and its main results. We report on a newly developed wind generator that successfully operates in the harsh Antarctic conditions and powers the station for a substantial time during the dark winter months. The robust ARIANNA surface architecture, combined with environmentally friendly solar and wind power generators, can be installed at any deep ice location on the planet and operated autonomously. We discuss the detector capabilities to determine the neutrino direction by reconstructing the signal arrival direction of a 800 m deep calibration pulser, and the reconstruction of the signal polarization using the more abundant cosmic-ray air showers. Lastly, we describe a large-scale design – ARIA – that capitalizes on the successful experience of the ARIANNA operation and is designed sensitive enough to discover the first UHE neutrino.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-783: Using Matrixx to Determine Transit Dose Contribution Over Clinically Useful Limits of HDR Source Activity

Purpose: Most HDR brachytherapy treatment planning systems (TPS) use TG-43 formalism to calculate dose without including transit dose corrections. Historically, measurement of this contribution has required sophisticated apparatus unavailable in most hospitals. We use Matrixx to investigate several scenarios where transit dose contribution may effect a clinical treatment. Methods: Treatment plans were generated using Oncentra Brachy TPS (Version 4.3.0.410, Nucletron ) on a CT scan of a 24-catheter Freiburg applicator (Nucletron ) laid flat on the MatriXX (IBA) detector. This detector is an array of 1020 parallel plate ion chambers. All 24 catheters were digitized and dwells within a central square region of 5×5cm of the applicator were activated. Each of the active catheters had 6 dwells in increments of 1.0cm. The plans were normalized to 10mm. This places the 100% isodose line at the correct effective point of measurement, which lies half-way between the parallel plates of the ion chambers. It is also within the clinically relevant treatment depth for superficial applications. A total of 6 plans were delivered for 3 prescription doses, 1Gy, 2Gy and 4Gy using source activities of 2.9Ci and 11.2Ci. The MatriXX array was operated to capture dosimetric snaps every 500ms and yielded an integral dose at the end of treatment. Results: A comparison of integral dose from 2 different source activities shows that the transit dose contribution is larger when the source activity is higher. It is also observed that the relative transit dose contribution decreases as prescription dose increases. This is quantified by the Gamma analysis. Conclusion: We have demonstrated that the Matrixx detector can be used to evaluate the contribution for a HDR source during transit from the HDR afterloader to a dwell location, and between adjacent dwell locations.

60 APPLIED LIFE SCIENCES↗