Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Spatial distribution of Compton-produced X-ray flux from rich and regular clusters of galaxies

The spatial distribution of radio and X-ray fluxes from rich and regular clusters of galaxies is discussed. A diffusion model is investigated in which high-energy electrons are ejected from a point source at the center of the cluster. While diffusing out, the electrons lose energy by Compton scattering with the universal blackbody photons, thus producing the X-ray emission. Traversing intracluster magnetic fields, the electrons emit synchrotron radio emission. For the Coma cluster of galaxies good agreement is found between the observed and predicted X-ray counting-rate distribution for the Compton model. From the observed radio data a value of about 3 by 10 to the -8th power gauss is deduced for the average magnetic-field strength in the central region of Coma.

Rephaeli, Y.↗

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.↗

Cloud-to-ground lightning flash characteristics from June 1984 through May 1985

A magnetic direction-finding network for the detection of lightning cloud-to-ground strikes has been installed along the east coast of the United States. Time, location, flash polarity, stroke count, and peak signal amplitude are recorded in real time. The data were recorded from Maine to North Carolina and as far west as Ohio; analyses were restricted to flashes within 300 km of a direction finder. Measurements of peak signal strength have been obtained from 720,284 first return strokes lowering negative charge. The resulting distribution indicates that few negative strokes have peak currents exceeding 100 kA. Measurements have also been obtained of peak signal strength from 17,694 first return strokes lowering positive charge. These strokes have a median peak current of 45 kA, with some peak currents reaching 300-400 kA. The median peak signal strength and the peak current, double from summer to winter for both negative and positive first return strokes. The polarity of ground flashes is observed to be less than 5 percent positive throughout the summer and early fall, then increases to over 50 percent during the winter, and returns to less than 10 percent in early spring. The percent of positive flashes with one stroke is observed to be approximately 90 percent throughout the year. The percent of negative flashes with one stroke is observed to increase from 40 percent in the summer to approximately 80 percent in January, returning to less than 50 percent in the spring.

Orville, Richard E.↗

A Diagnostic Analysis of the Kennedy Space Center LDAR Network: Cross-Sensor Studies - 2

Range dependencies in total (intracloud and cloud-to-ground) lightning observed by the Kennedy Space Center Lightning Detection and Ranging (LDAR) network are established through cross-comparison with other lightning sensors. Using total lightning observed by the Lightning Imaging Sensor (LIS), LDAR flash detection efficiency is shown to remain above 90% out to 90-100 km range, and to be below 25% at 200 km range. LDAR VHF source location error distributions are also determined as a function of range, and are found to be asymmetric with first moments increasing roughly as range squared. Range normalization schemes for total VHF source density are tested and shown to yield significant (up to 50%) skill improvements over uncorrected data, when compared with National Lightning Detection Network (NLDN) ground flash counts at hourly, daily, monthly and climatological time scales.

Boccippio, D. J.↗

Reconciling the MOLA, TES, and Neutron Observations of the North Polar CO2 Mass Budget on Mars

There are now three independent observations of the CO2 polar cap mass budget of Mars' north polar cap. The first is based elevation changes detected by the Mars Orbiter Laser Altimeter (MOLA) on the Mars Global Surveyor (MGS). The second is based on MGS Thermal Emission Spectrometer (TES) broadband observations of the solar and infrared radiation fields at the top of the atmosphere. The third is based on neutron counts measured by the neutron spectrometer (NS) on Odyssey. The TES data are based on an energy balance. The net radiative loss (gain) in a column is balanced by latent heating due condensation (sublimation) of CO2. In calculating the mass budget, the other main energy sources, atmospheric heat transport and subsurface conduction, were neglected. At the pole, atmospheric heat transport is indeed a small term. However, subsurface heat conduction can be significant because at the North Pole water ice, which has a high thermal conductivity compared to bare soil, is a dominant component of the subsurface. Thus, heat conducted down into the ice during summer will slowly bleed back out during fall and winter reducing the amount of CO2 that condenses on the pole. We have taken a first cut at quantifying this effect by fitting a curve to Paige's estimates of the conducted energy flux in his analysis of Viking IRTM data.

Haberle, R. M.↗

Toxicity and Radioprotective Effects of DF-1 and Carbon Nanotubes in Human Lung and Liver Cell Lines

The DF-1 compound, a sixty carbon fullerene derivative, has been shown to have antioxidant effects and is thought to possibly help mediate the effects of radiation on cells. While this is potentially useful, it is important to first understand the effect that the DF-1 has on the cells and the growth rate of the cells to determine if the material itself has any innate toxicity. A growth curve was established for both HF-19 cells, human fibroblasts, and HepG2 cells, liver tissue cells in the presence of two different concentrations of DF-1 and for untreated controls. The cells were plated in triplicate in 60mm dishes and were lifted and counted with a hemocytometer daily for one week. The growth curve data for the HF-19 cells show that while the low concentration of DF-1 had no apparent effect on the growth rate, the high concentration of DF-1 appeared to severely inhibit the growth of the HF-19 cells. The growth curve data for the HepG2 cells shows that the DF-1 compound had no significant effect on the rate at which the cells grew. A second growth curve study was performed plain carbon nanotubes, but with only 24 hour exposure to a high and low concentration of material. The carbon nanotubes are another carbon compound similar to DF-1, but in the shape of a tube, rather than a ball. We hypothesize that nanotubes may also mediate the effect of radiation on cells. This time, nanotubes did not showed any significant effect on the growth rate HF-19 or HepG2 cells. A third growth curve study is underway to further determine the effect of DF-1, nanotubes, and a derivatized nanotube (BHT-nanotubes). This derivatized nanotube has been modified with a compound that is known to be very effective at neutralizing free radicals. We expect that the high concentration of DF-1 and possibly the nanotubes and BHT-nanotubes may inhibit the growth of the HF-19 cells while the low concentration will resemble the growth of the control. We also hypothesize that there will be no significant effect on the growth of the HepG2 cells by the nanotubes, and BHT-nanotubes. In order to examine the usefulness of the DF-1, nanotubes, and BHT-nanotubes in mediating the effects of radiation a clonogenic assay is being performed. The HF-19 cells were plated in different concentrations of the various compounds and exposed to varying amounts of radiation. The cells are being allowed to grow in a small enough concentration so that the ability of each cell to divide can be seen by the development of cell clusters. By comparing the irradiated control to the un-irradiated control the effects of radiation alone can be seen. By comparing the compound treated irradiated cells to the irradiated control the usefulness of each compound can be seen. It is thought that Amifostine, the positive control, will have more regularly dividing cells then the irradiated control, as will DF-1 and hopefully both nanotube materials as well.

Burgoyne, Madeline↗

All-Sky Earth Occultation Observations with the Fermi Gamma-Ray Burst Monitor

Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique. Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux by determining the change in count rate due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors and spanning 150 keV to 40 MeV for the GBM BGO detectors. Our preliminary catalog consists of galactic X-ray binaries, the Crab Nebula, and active galactic nuclei. We will present early results. Regularly updated results can be found on our website http://gammaray.nsstc.nasa.gov/gbm/science/occultation.

Wilson-Hodge, C. A.↗

All-Sky Earth Occultation Observations with the Fermi Gamma-Ray Burst Monitor

Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/ soft gamma ray sky using the Earth occultation technique. Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors and spanning 150 keV to 40 MeV for the GBM BGO detectors. Our preliminary catalog consists of galactic X-ray binaries, the Crab Nebula, and active galactic nuclei. In addition, to Earth occultations, we have observed numerous occultations with Fermi's solar panels.

Wilson-Hodge, C. A.↗

All-Sky Earth Occultation Observations with the Fermi Gamma Ray Burst Monitor

Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique. Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors and spanning 150 keV to 40 MeV for the GBM BGO detectors. Our preliminary catalog consists of galactic X-ray binaries, the Crab Nebula, and active galactic nuclei. New sources are added to our catalog as they become active or upon request. In addition to Earth occultations, we have observed numerous occultations with Fermi's solar panels. We will present early results. Regularly updated results will be found on our website http://gammaray.nsstc.nasa.gov/gbm/science/occultation.

Wilson-Hodge, C. A.↗

Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver

The simplified architecture is a minimal system for a deep-space optical communications transceiver. For a deepspace optical communications link the simplest form of the transceiver requires (1) an efficient modulated optical source, (2) a point-ahead mechanism (PAM) to compensate for two-way light travel, (3) an aperture to reduce the divergence of the transmit laser communication signal and also to collect the uplink communication signal, and (4) a receive detector to sense the uplink communication signal. Additional components are introduced to mitigate for spacecraft microvibrations and to improve the pointing accuracy. The Canonical Transceiver implements this simplified architecture (see figure). A single photon-counting smart focal plane sensor combines acquisition, tracking, and forward link data detection functionality. This improves optical efficiency by eliminating channel splits. A transmit laser blind sensor (e.g. silicon with 1,550-nm beam) provides transmit beam-pointing feedback via the two-photon absorption (TPA) process. This vastly improves the transmit/receive isolation because only the focused transmit beam is detected. A piezoelectric tiptilt actuator implements the required point-ahead angle. This point-ahead mechanism has been demonstrated to have near zero quiescent power and is flight qualified. This architecture also uses an innovative 100-mHz resonant frequency passive isolation platform to filter spacecraft vibrations with voice coil actuators for active tip-tilt correction below the resonant frequency. The canonical deep-space optical communications transceiver makes synergistic use of innovative technologies to reduce size, weight, power, and cost. This optical transceiver can be used to retire risks associated with deep-space optical communications on a planetary pathfinder mission and is complementary to ongoing lunar and access link developments.

Ortiz, Gerard G.↗

Earth Occultation Monitoring with the Fermi Gamma Ray Burst Monitor

Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique (EOT). Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors for daily monitoring. Light curves, updated daily, are available on our website http://heastro.phys.lsu.edu/gbm. Our software is also capable of performing the Earth occultation monitoring using up to 128 energy bands, or any combination of those bands, using our 128-channel, 4-s CSPEC data. The GBM BGO detectors, sensitive from about 200 keV to 40 keV, can also be used with this technique. In our standard application of the EOT, we use a catalog of sources to drive the measurements. To ensure that our catalog is complete, our team has developed an Earth occultation imaging method. In this talk, I will describe both techniques and the current data products available. I will highlight recent and important results from the GBM EOT, including the current status of our observations of hard X-ray variations in the Crab Nebula.

Wilson-Hodge, Colleen A.↗

X-ray Streak Camera Cathode Development and Timing Accuracy of the 4w UV Fiducial System at the National Ignition Facility

The convergent ablator experiments at the National Ignition Facility (NIF) are designed to measure the peak velocity and remaining ablator mass of an indirectly driven imploding capsule. Such a measurement can be performed using an x-ray source to backlight the capsule and an x-ray streak camera to record the capsule as it implodes. The ultimate goal of this experiment is to achieve an accuracy of 2% in the velocity measurement, which translates to a {+-}2 ps temporal accuracy over any 300 ps interval for the streak camera. In order to achieve this, a 4-{omega} (263nm) temporal fiducial system has been implemented for the x-ray streak camera at NIF. Aluminum, Titanium, Gold and Silver photocathode materials have been tested. Aluminum showed the highest quantum efficiency, with five times more peak signal counts per fiducial pulse when compared to Gold. The fiducial pulse data was analyzed to determine the centroiding a statistical accuracy for incident laser pulse energies of 1 and 10 nJ, showing an accuracy of {+-}1.6 ps and {+-}0.7 ps respectively.

42 ENGINEERING↗

Hardware support for software controlled fast reconfiguration of performance counters

Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.

97 MATHEMATICS AND COMPUTING↗

Hardware support for software controlled fast reconfiguration of performance counters

Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.

97 MATHEMATICS AND COMPUTING↗

DEVELOPMENT OF CONTROLLED PITCH NANO ARRAYS FOR APPLICATION IN NANO SCALE BASED PROPORTIONAL COUNTERS

Proportional counters (PCs) are a type of gas-filled radiation detection device capable of distinguishing between a wide range of radiation types and energies. In this application, however, these devices are limited by high power consumption and high bias potentials required to operate in the proportional detection regime. Previous work performed with a single carbon nanotube (CNT) anode has shown that nanoscale-based PCs can operate at bias potentials of 10V rather than the 1000V range required for PCs. ''Proof of concept'' experiments with a single CNT as the anode exhibit a small detection volume and consequently required long count times (24 hrs). To make this a practical detector technology (i.e., decrease the count time), the effective detection volume has to be increased. Experimental data and electric field modeling show that if the pitch (spacing between individual nanotubes) of the arrays is too small, the electric field of the individual nanostructure will collapse and the nanoscale array will behaved as a single macro-scale field with the associated high bias potential required to reach the proportional region. Electric-field modeling of the affect of nanostructure pitch on the electric field distribution of these arrays predicted that a pitch of about two-and-a-times the height of the nanostructure was required to retain the nanoscale electric field. In this work, we report on the fabrication and electrical property testing of nanoscale arrays with a range of controlled pitches.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Biomathematical Model of Lymphopoiesis and Its Application to Acute and Chronic Irradiation Assessment

After the events of September 11, 2001, there is an increasing concern of the occurrence of radiological terrorism that may result in significant casualties in densely populated areas. Much effort has been made to establish various biomarkers to rapidly assess radiation dose in mass-casualty and population-monitoring scenarios, which are demanded for effective medical management and treatment of the exposed victims. Among these the count of lymphocytes in peripheral blood and their depletion kinetics are the most important early indicators of the severity of the radiation injury. In this study, we examine a biomathematical model of lymphopoiesis which has been successfully utilized to simulate and interpret experimental data of acute and chronic irradiations on rodents [1]. With revised parameters for humans, we find this model can reproduce several sets of clinical lymphocyte data of accident victims over a wide range of absorbed doses. In addition, the absolute lymphocyte counts and the depletion rate constants calculated by this model also show good correlation with the Guskova formula and the Goans model, the two empirical tools which have been widely recognized for early estimation of the exposed dose after radiation accidents [2]. We also use the model to analyze the hematological data of the Techa River residents which were exposed to chronic low-dose irradiation during 1950-1956 [3]. This model can serve as a computational tool in radiation accident management, military operations involving nuclear warfare, radiation therapy, and space radiation risk assessment.

Hu, Shaowen↗

Ultrasoft x ray bursts: A clue to the origin of gamma ray bursts?

A search was conducted for short timescale (less than or approx. 10 s) faint X ray bursts in the complete 201,000,000 photon Einstein Observatory imaging proportional counter (IPC) data base. Some 73,000,000 events were extracted which were distributed among 11,230 observing intervals with an average observing time of approx. 1400 seconds. To exclude all sources, only those spatial pixels were searched with a count rate less than 6 x 10(exp -4) counts/sec sq arcmin. The mean count rate was much less. All files with less than 400 secs of observing time were excluded. The data was then binned into overlapping cells 4'.3 by 4'.3 by 10 secs in volume, and all the space-time cells were searched to locate cells with more than 5 counts in a 10 sec interval; i.e., a minimum flux enhancement of 50 over the mean rate for that point in space. Some 52 such events were found. An annulus was inspected around the event to see if it coincided with a general rise in the counter's event rate. Ten events did coincide with counter phenomena; these were associated with sunrise, sunset, or the approach of the South Atlantic Anomaly and were excluded. The remaining 42 events were then examined in an attempt to associate them with instrumental or environmental artifacts. The event occurrence times are uniformly distributed over the course of the mission and show no correlation with local solar time; their positions are randomly distributed in geographic, Galactic, and celestial coordinates. Their summed radial distribution is consistent with the point response function of the IPC for a soft source, indicating that the events are focused by the Observatory's mirror system. The integrated spectrum is, indeed, quite soft and is very similar to that of the cataclysmic variable star U Gem in outburst. Most of the events have risetimes of less than or approx. 1 sec and decay times ranging from 1 to 20 sec. Their positions are not associated with any class of catalogued objects. Several possible origins are discussed for the events; if they are associated with gamma ray bursters, they provide interesting constraints on the space density and repetition rate of the underlying source population.

Helfand, D. J.↗