Search NASA⌕ Search

SEARCH · Search NASA

Results for “deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Impact on Patient Safety and Satisfaction of Implementation of an Outpatient Clinic in Interventional Radiology (IPSIPOLI-Study): A Quasi-Experimental Prospective Study

PurposeInterventional radiology (IR) procedures are associated with high rates of preparation and planning errors. In many centers, pre-procedural consultation and screening of patients is performed by referring physicians. Interventional radiologists have better knowledge about procedure details and risks, but often only get acquainted with the patient in the procedure room. We hypothesized that patient safety (PS) and patient satisfaction (PSAT) in elective IR procedures would improve by implementation of a pre-procedural visit to an outpatient IR clinic.Material and MethodsIRB approval was obtained and informed consent was waived. PS and PSAT were measured in patients undergoing elective IR procedures before (control group; n = 110) and after (experimental group; n = 110) implementation of an outpatient IR clinic. PS was measured as the number of process deviations. PSAT was assessed using a questionnaire measuring Likert scores of three dimensions: interpersonal care aspects, information/communication, and patient participation. Differences in PS and PSAT between the two groups were compared using an independent t test.ResultsThe average number of process deviations per patient was 0.39 in the control group compared to 0.06 in the experimental group (p < 0.001). In 9.1 % patients in the control group, no legal informed consent was obtained compared to 0 % in the experimental group. The mean overall Likert score was significantly higher in the experimental group compared to the control group: 2.68 (SD 0.314) versus 2.48 (SD 0.381) (p < 0.001).ConclusionPS and PSAT improve significantly if patients receive consultation and screening in an IR outpatient clinic prior to elective IR procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Robotic Assistance Device in Computed Tomography-Guided Percutaneous Diagnostic and Therapeutic Procedures

PurposeTo evaluate a commercially available robotic assistance device for computed tomography-guided diagnostic and therapeutic interventions, compared to regular, manually performed CT scan-guided interventions in terms of precision, exposure to radiation to the patient and intervention time.Materials and MethodsOver a period of 6 months, 55 consecutive patients were recruited and treated using robotic assistance and compared to a control group of 101 patients previously treated with a regular CT scan-guided, manual approach. Evaluated parameters were precision (deviation from planned target and number of needle replacements), radiation exposure to the patient and intervention time. Evaluations were performed with regard to complexity (in-plane vs out-of-plane interventions) and type of anesthesia (general vs local).ResultsParameters related to precision were in general significantly better in the robotic assistance group (p < 0.01) with a mean deviation of 1.2 mm (± 1.6 mm) compared to 2.6 mm (± 1.1 mm) in the comparison group. Compared to manual procedure, the mean intervention time was reduced by 15 min (± 5.4 min) on average for an out-of-plane needle placement in the robotic group. There was no increase of exposure to radiation to the patient while radiation exposure for the physician was reduced to zero when the navigation system was used.ConclusionCompared to manual placement, the use of a robotic assistance device in out-of-plane CT-guided interventions under general anesthesia allows for probe placement with high precision. Intervention time is reduced with no increase of exposure to radiation to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kinetic control of phase evolution and defect-mediated recombination in AACVD-grown copper antimony sulphide thin films

Copper antimony sulphide (CAS) is a multinary chalcogenide semiconductor in which small deviations from stoichiometry can drive phase competition and strong defect-mediated modulation of optoelectronic properties. However, the systematic roles of copper precursor fraction and deposition time in governing phase evolution, off-stoichiometry, and recombination dynamics in aerosol-assisted chemical vapour deposition (AACVD)-grown undoped CAS thin films remain insufficiently understood. In this work, undoped CAS thin films were deposited by AACVD using Cu(dedtc)2 and Sb(dedtc)3 single-source precursors at 550 °C and a carrier gas flow rate of 150 sccm, while the Cu(dedtc)2 mole fraction (x = 0.15 – 0.55) and deposition time (1 – 2 hours) were systematically varied to probe how growth kinetics influence phase composition, microstructure, and defect-mediated optical properties without post-deposition annealing or extrinsic doping. Increasing copper precursor content drives phase evolution toward tetrahedrite-dominant CAS films at intermediate Cu(dedtc)2 mole fractions, with the film deposited at x = 0.35 exhibiting the strongest tetrahedrite character within the parameter space examined. The films are also copper-rich, antimony-poor, and sulphur-deficient, consistent with off-stoichiometric growth and intrinsic defect formation, plausibly including copper interstitials, Cu-on-Sb antisites, and sulphur vacancies. These growth-dependent compositional deviations are accompanied by tunable indirect optical bandgaps of approximately 1.60 – 2.18 eV and weak visible photoluminescence governed by defect-mediated recombination. Time-resolved photoluminescence reveals bi-exponential decay behaviour with lifetimes of approximately 0.1 – 3.6 ns, with emission dominated by slower donor–acceptor pair recombination and a smaller contribution from faster trap-assisted pathways. Collectively, these results establish an explicit kinetic process–structure–defect–property relationship for AACVD-grown CAS thin films and provide a growth–structure–property framework relevant to future optimization of CAS-based optoelectronic and energy materials.

36 MATERIALS SCIENCE↗

Data-Driven, In Situ, Relative Sensor Calibration Based on Waveform Fitting Moment Tensor Inversion

This article presents a deconvolution-based methodology for the relative calibration of acoustic emission sensors. The method uses the observations from multiple acoustic emission arrivals to estimate correction functions that account for instrument response and site effects. The corrections act on the measurements reshaping the wave arrivals, in many cases allowing visible discrimination between compressional and shear phases. The methodology is illustrated with the application on a dataset obtained during the hydraulic fracturing at triaxial stress conditions of a Colton sandstone block. A workflow for the estimation of full moment tensor solutions, including the generation of quality control attributes complements the presentation. The moment tensor solutions display fracture geometries mostly aligned with the main hydraulic fracture’s plane. The style of activation can be associated with an extensive stress regime before breakdown and to a compressional stress regime after breakdown, when the pumps were reversed to withdraw fluid from the block. In conclusion, the source types commonly deviate from the pure double-couple type; however, the deviations are under 30° in the case of opening fractures, and under 20° in the case of closing fractures. Therefore, the acoustic emissions in this experiment are the result of predominantly shearing dislocations.

47 OTHER INSTRUMENTATION↗

Local composition activity coefficient model for mixed-gas adsorption equilibria

Taking into consideration the adsorbate–adsorbent interactions, a novel activity coefficient model is derived from the non-random two-liquid theory for mixed-gas adsorption equilibria. In contrast with the conventional activity coefficient models developed for bulk liquids, the new model correctly predicts negative deviations from ideality for adsorbed phase mixtures including azeotropic behavior exhibited by selected gas-adsorbent systems. Here, the requiring a single binary interaction parameter per adsorbate–adsorbate pair, the model successfully correlates wide varieties of binary adsorption isotherm data and it should be a powerful engineering thermodynamic tool in correlating and predicting mixed-gas adsorption equilibria.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of damage and failure in an additively manufactured 316L SS structure: experimental reinvestigation of the third Sandia fracture challenge

The third Sandia Fracture Challenge (SFC3) was a benchmark problem for comparing experimental and simulated ductile deformation and failure in an additively manufactured (AM) 316L stainless steel structure. One surprising observation from the SFC3 was the Challenge-geometry specimens had low variability in global load versus displacement behavior, attributed to the large stress-concentrating geometric features dominating the global behavior, rather than the AM voids that tend to significantly influence geometries with uniform cross-sections. This current study reinvestigates the damage and failure evolution of the Challenge-geometry specimens, utilizing interrupted tensile testing with micro-computed tomography (micro-CT) scans to monitor AM void and crack growth from a virgin state through complete failure. This study did not find a correlation between global load versus displacement behavior and AM void attributes, such as void volume, location, quantity, and relative size, which incidentally corroborates the observation from the SFC3. However, this study does show that the voids affect the local behavior of damage and failure. Surface defects (i.e. large voids located on the surface, far exceeding the nominal surface roughness) that were near the primary stress concentration affected the location of crack initiation in some cases, but they did not noticeably affect the global response. The fracture surfaces were a combination of classic ductile dimples and crack deviation from a more direct path favoring intersection with AM voids. Even though the AM voids promoted crack deviation, pre-test micro-CT scan statistics of the voids did not allow for conclusive predictions of preferred crack paths. This study is a first step towards investigating the importance of voids on the ductile failure of AM structures with stress concentrations.

36 MATERIALS SCIENCE↗

The Q p Weak experiment

In May 2012, the Q p Weak collaboration completed a two year measurement program to determine the weak charge of the proton Q p W = (1 – 4sin²θ W ) at the Thomas Jefferson National Accelerator Facility (TJNAF). The experiment was designed to produce a 4.0 % measurement of the weak charge, via a 2.5 % measurement of the parity violating asymmetry in the number of elastically scattered 1.165 GeV electrons from protons, at forward angles. At the proposed precision, the experiment would produce a 0.3 % measurement of the weak mixing angle at a momentum transfer of Q² = 0.026 GeV², making it the most precise stand alone measurement of the weak mixing angle at low momentum transfer. In combination with other parity measurements, Q p Weak will also provide a high precision determination of the weak charges of the up and down quarks. At the proposed precision, a significant deviation from the Standard Model prediction could be a signal of new physics at mass scales up to ≅ 6 TeV, whereas agreement would place new and significant constraints on possible Standard Model extensions at mass scales up to ≅ 2 TeV. This paper provides an overview of the physics and the experiment, as well as a brief look at some preliminary diagnostic and analysis data.

electron scattering↗

Speed of Sound Measurements of Binary Mixtures of Hydrofluorocarbons [Pentafluoroethane (R-125), 1,1-Difluoroethane (R-152a), or 1,1,1,2,3,3,3-Heptafluoropropane (R-227ea)] with Hydrofluoroolefins [2,3,3,3-Tetrafluoropropene (R-1234yf) or trans-1,3,3,3-Tetrafluoropropene (R-1234ze(E))]

In this article, speed of sound data measured using a dual-path pulse-echo instrument are reported for three binary refrigerant mixtures, R-125/1234yf, R-1234yf/152a, and R-1234ze(E)/227ea, at compositions of (0.33/0.67) and (0.67/0.33) mole fraction. The speed of sound was studied at temperatures ranging from 230 K to 345 K from pressures slightly above the bubble point curve up to 20 MPa for the mixtures containing R-1234yf and 49 MPa for the R-1234ze(E)/227ea mixtures. The relative combined expanded speed of sound uncertainty ranged from 0.039 % to 0.317 % with a mean uncertainty over all state points of less than 0.10 %. The reported data are compared to the most recent mixture models in REFPROP for each blend studied. Comparisons of available mixture models for the R-125/1234yf and R-1234yf/152a blends exhibit average absolute deviation values ranging from 0.10 % to 0.27 %, and the average absolute deviations for R-1234ze(E)/227ea blends range from 0.62 % to 0.94 %. The comparisons show that only minor adjustments are required to the R-125/1234yf and R-1234yf/152a mixture models to represent the speed of sound data within its uncertainty. However, significant adjustments are needed to improve the current mixture models for the R-1234ze(E)/227ea blend. Deficiencies with the R-1234ze(E)/227ea mixture model are not unexpected since it (1) utilizes a pure-fluid EOS R-1234ze(E) that has been shown to inaccurately represent R-1234ze(E) speed of sound values and (2) uses binary interaction parameters for the chemically similar mixture of R-1234yf/227ea.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Analysis of Ca, Mg, and K in the Roots of Angelica pubescens f. biserrata by Laser-Induced Breakdown Spectroscopy Combined with Artificial Neural Networks

Laser-induced breakdown spectroscopy has been applied for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens Maxim. f. biserrata Shan et Yuan used in traditional Chinese medicine. Ca II 317.993 nm, Mg I 517.268 nm, and K I 769.896 nm spectral lines have been chosen to set up calibration models for the analysis using the external standard and artificial neural network methods. The linear correlation coefficients of the predicted concentrations versus the standard concentrations of six samples determined by the artificial neural network method are 0.9896, 0.9945, and 0.9911 for Ca, Mg, and K, respectively, which are better than for the external standard method. The artificial neural network method also gives better performance comparing with the external standard method for the average and maximum relative errors, average relative standard deviations, and most maximum relative standard deviations of the predicted concentrations of Ca, Mg, and K in the six samples. Finally, it is proved that the artificial neural network method gives better performance compared to the external standard method for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of the Thermodynamic Properties of the Cyclohexane + n-Octane + n-Hexadecane Liquid Mixture by the Acoustic Method

The propagation of sound in the ternary cyclohexane + n-octane + n-hexadecane mixture at temperatures of 298–433 K and pressures of 0.1–100.1 MPa was investigated experimentally. The maximum error in measuring the velocity of sound in this mixture was 0.1%. Experimental data on the velocity of sound in such a mixture were obtained for the first time. On the basis of these data, the density, the isobaric expansion coefficient, the isobaric and isochoric heat capacities, and the isothermal compressibility of the indicated ternary mixture of three compositions at a temperature of 298–348 K and a pressure of 0.1–100 MPa and the deviation of the velocity of sound in it from the ideal one were determined. With the use of a number of semiempirical equations, the deviation of the velocity of sound in this mixture from the ideal one was estimated on the basis of the data on the velocity of sound in its pure components and in their binary compounds. A good agreement between the calculation and experimental data has been obtained. A table of the thermodynamic properties of the cyclohexane + n-octane + n-hexadecane mixture is presented.

42 ENGINEERING↗

Numerical studies of three-dimensional stochastic Darcy's equation and stochastic advection-diffusion-dispersion equation

In this study, we solve the three-dimensional stochastic Darcy's equation and stochastic advection-diffusion-dispersion equation using a probabilistic collocation method (PCM) on sparse grids. Karhunen-Lo\`{e}ve (KL) decomposition is employed to represent the three-dimensional log hydraulic conductivity $Y=\ln K_s$. The numerical examples which demonstrate the convergence of PCM are presented. It appears that the faster convergence rate in the variance can be obtained by using the Jacobi-chaos representing the truncated Gaussian distributions than using the Hermite-chaos for the Gaussian distribution. The effect of dispersion coefficient on the mean and standard deviation of the hydraulic head and solute concentration is investigated. Additionally, we also study how the statistical properties of the hydraulic head and solute concentration vary while using different types of random distributions and different standard deviations of random hydraulic conductivity.

97 MATHEMATICS AND COMPUTING↗

Physical Properties of Mn{sub 2}O{sub 3} Nanoparticles Synthesized by Co-precipitation Method at Different pH Values

Mn{sub 2}O{sub 3} nanoparticles were synthesized at different pH values ranging from 10 to 13 by co-precipitation technique. The characterization of all samples were completed by X-ray diffraction (XRD), transmission electron microscopy (TEM), energy-dispersive X-ray (EDX), thermogravimetric analysis (TGA), Fourier transform infrared (FTIR), ultraviolet-absorption spectroscopy (UV), Raman spectroscopy, and M–H loop measurements. The XRD spectra show that the structure of Mn{sub 2}O{sub 3} is cubic, and the lattice parameter a decreases as pH increases. Crystalline size, determined from TEM and XRD analyses, decreases as pH increases. TGA curves show that a mass loss is significantly affected as pH increases, indicating the decomposition of organic species besides the oxidation of Mn{sub 2}O{sub 3} to Mn{sub 3}O{sub 4}. FTIR spectra indicate that the absorption peaks at 593.73 and 519.09 cm{sup − 11} referred to the stretching vibration of Mn–O and Mn–O–Mn bonds during the synthesis of Mn{sub 2}O{sub 3} nanoparticles. UV-visible spectroscopy is measured in the range 250–800 nm and showed a deviation to the lower wavelength in addition to an increase in the band-gap energy (E{sub g}) values from 1.012 to 1.370 eV is obtained. Raman spectra shows a slight deviation to the left which is conversely proportional to the crystalline size. M–H loops for the prepared samples were measured and the results of retentivity (M{sub s}) and coercivity (H{sub c}) were discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Porous Chromatographic Materials as Substrates for Preparing Synthetic Nuclear Explosion Debris Particles

In this study, we investigated several porous chromatographic materials as synthetic substrates for preparing surrogate nuclear explosion debris particles. The resulting synthetic debris materials are of interest for use in developing analytical methods. Eighteen metals, including some of forensic interest, were loaded onto materials by immersing them in metal solutions (556 mg/L of each metal) to fill the pores, applying gentle heat (110°C) to drive off water, and then treating them at high temperatures (up to 800°C) in air to form less soluble metal species. High-boiling-point metals were uniformly loaded on spherical controlled-pore glass to emulate early fallout, whereas low-boiling-point metals were loaded on core-shell silica to represent coated particles formed later in the nuclear fallout-formation process. Analytical studies were applied to characterize solubility, material balance, and formation of recalcitrant species. Dissolution experiments indicated loading was 1.5 to 3 times higher than expected from the pore volume alone, a result attributed to surface coating. Analysis of load solutions before and after filling the material pores revealed that most metals were passively loaded; that is, solutions filled the pores without active metal discrimination. However, niobium and tin concentrations were lower in solutions after pore filling, and were found in elevated concentrations in the final products, indicating some metals were selectively loaded. High-temperature treatments caused reduced solubility of several metal species, and loss of some metals (rhenium and tellurium) because volatile species were formed. Sample preparation reproducibility was high (the inter-batch relative standard deviation was 7.8%, and the intra-batch relative standard deviation was 0.84%) indicating that this material is suitable for use as a working standard for analytical methods development. We anticipate future standardized radionuclide-loaded materials will find use in radioanalytical methods development and/or serve as a starting material for the synthesis of more complex forms of nuclear explosion debris (e.g., Trinitite).

36 MATERIALS SCIENCE↗

Production of monodisperse cerium oxide microspheres with diameters near 100 µm by internal-gelation sol–gel methods

Cerium dioxide microspheres with uniform diameters between 65 – 211 µm were fabricated using internal gelation sol-gel methods. Although uniform microspheres are produced for nuclear fuel applications with diameters above 300 µm, sol-gel microspheres with diameters of 50 - 200 µm have historically been made by emulsion techniques and had poor size uniformity [1, 2]. An internal gelation, sol-gel apparatus was designed and constructed to accommodate the production of small, uniform microspheres whereby cerium-containing solutions were dispersed into flowing silicone oil and heated in a gelation column to initiate solidification [3, 4]. Problems with premature feed gelation and microsphere coalescence were overcome by equipment modifications unique among known internal gelation setups. Microspheres were fabricated and sized in batches as a function of dispersing needle diameter and silicone oil flow rate in the two-fluid nozzle in order to determine the range of sizes possible and corresponding degree of monodispersity. Initial experiments with poor size uniformity were linked to microsphere coalescence in the gelation column prior to solidification as well as excessive flow rates for the cerium feed solution. Average diameter standard deviations as low as 2.23% were observed after optimization of flow rates and minimization of coalescence reactions.

cerium oxide↗

Two-Phase Flow in Porous Media: Predicting Its Dependence on Capillary Number and Viscosity Ratio

Motivated by the need to determine the dependencies of two-phase flow in a wide range of applications from carbon dioxide sequestration to enhanced oil recovery, we have developed a standard two-dimensional, pore-level model of immiscible drainage, incorporating viscous and capillary effects. This model has been validated through comparison with several experiments. For a range of stable viscosity ratios (M=μ injected,nwf /μ defending,wf ≥ 1), we had increased the capillary number, N c and studied the way in which the flows deviate from fractal capillary fingering at a characteristic time and become compact for realistic capillary numbers. This crossover has enabled predictions for the dependence of the flow behavior upon capillary number and viscosity ratio. Our results for the crossover agreed with earlier theoretical predictions, including the universality of the leading power-law indicating its independence of details of the porous medium structure. In this article, we have observed a similar crossover from initial fractal viscous fingering (FVF) to compact flow, for large capillary numbers and unstable viscosity ratios M < 1. In this case, we increased the viscosity ratio from infinitesimal values, and studied the way in which the flows deviate from FVF at a characteristic time and become compact for non-zero viscosity ratios. This crossover has been studied using both our pore-level model and micro-fluidic flow-cell experiments. The same characteristic time, τ = 1/M 0.7 , satisfactorily describes both the pore-level results.

36 MATERIALS SCIENCE↗

The Surface-Topography Challenge: A Multi-Laboratory Benchmark Study to Advance the Characterization of Topography

Surface performance is critically influenced by topography in virtually all real-world applications. The current standard practice is to describe topography using one of a few industry-standard parameters. The most commonly reported number is Ra, the average absolute deviation of the height from the mean line (at some, not necessarily known or specified, lateral length scale). However, other parameters, particularly those that are scale-dependent, influence surface and interfacial properties; for example the local surface slope is critical for visual appearance, friction, and wear. The present Surface-Topography Challenge was launched to raise awareness for the need of a multi-scale description, but also to assess the reliability of different metrology techniques. In the resulting international collaborative effort, 153 scientists and engineers from 64 research groups and companies across 20 countries characterized statistically equivalent samples from two different surfaces: a “rough” and a “smooth” surface. The results of the 2088 measurements constitute the most comprehensive surface description ever compiled. We find wide disagreement across measurements and techniques when the lateral scale of the measurement is ignored. Consensus is established through scale-dependent parameters while removing data that violates an established resolution criterion and deviates from the majority measurements at each length scale. Our findings suggest best practices for characterizing and specifying topography. The public release of the accumulated data and presented analyses enables global reuse for further scientific investigation and benchmarking.

42 ENGINEERING↗

Evolution of Residual Stress and Distortion of Cold-Rolled Bearing Ring from Annealing to Quenched-Tempered Heat Treatment

This study investigates the correlation between the residual stress and distortion behavior of a cold-rolled ring from the annealing to quenching-tempering (QT) process. Due to the cold-rolled process, the external periphery of the bearing ring experiences a compressive residual stress. To relieve the residual stress, cold-rolled rings are annealed at 700 °C which is higher than the starting temperature of recrystallization. When cold-rolled rings are annealed at 700 °C for 15 min, the compressive residual stress is reduced to zero and the outer diameter of the annealed ring becomes larger than that of a non-annealed sample, which is unrelated to annealing time. Simultaneously, the roundness and taper deviation do not obviously change compared with those of non-annealed sample. The stress relaxation during the annealing process was attributed to the recovery and recrystallization of ferrite. Annealing has a genetic influence on the following QT heat treatment, wherein the lowest residual stress is in the non-annealed cold-rolled ring. From the annealing to QT process, the deviation of the outer diameter, roundness, and taper increased with annealing time, a large extend than that of non-annealed samples.

36 MATERIALS SCIENCE↗

Nonuniformity in Mechanical Properties of Linear Friction Welded Mild Steel Joint

Mild steel was successfully joined by linear friction welding. Grain size at peripheral region was coarser than that at the other zones of the weld interface, which had no significant effect on microhardness. The local tensile properties were considerably decreased when oxides or lack of bonding appeared at the interface. Ductile fracture dominated the fracture mode for all joints. Variation in local tensile properties could be relieved under a medium friction pressure, a relatively high amplitude with a sufficient friction time. It was attributed to the facts that plastic metal layer of joint became uniform to some extent and interfacial defects were eliminated. The standard deviation of plastic metal layer thickness (χ{sub p}) could be used to describe the combined effects of welding parameters on joint integral performance. It was found that the standard deviation of plastic metal layer thickness showed a strong inverse correlation with the joint integral performance. Well-formed and defect-free joints exhibiting 90% of the base metal tensile strength could be produced when processing at a frequency of 20 Hz with a friction pressure of 103 MPa or 155 MPa, an amplitude of 2.5 mm and a friction time of at least 4 s.

36 MATERIALS SCIENCE↗