Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Development of an Interactive Valuation Model for Distributed Energy Resource Value

The Oklahoma Secretary of Commerce & Tourism (OSCT) seeks to address perceived challenges and barriers to the deployment of distributed energy generation resources (DERs), including solar and other technologies, in the state of Oklahoma. The Scope of Work (SOW) outlines follow-on tasks related to the previous CRADA # CRD-18-762. The first task will finalize the Interactive Valuation Model Requirements Document, the final draft of which was provided in June 2018. The second task includes the building, validation, and finalization of the interactive valuation model for expressing distributed energy resource value based on user inputs to be completed by June 30, 2019. Training for how to prepare the data inputs and use the model will also be provided. To address perceived challenges and barriers to the deployment of distributed energy generation resources (DERs), including solar and other technologies, in the state of Oklahoma, the work under this CRADA will: 1) finalize the draft Interactive Valuation Model Requirements Document delivered in June 2018; 2) finish building and validating the interactive valuation model for expressing DER value based on user inputs, and 3) provide training for use of this model.

14 SOLAR ENERGY↗

Processes Controlling Water Vapor in the Winter Arctic Stratospheric Middleworld

Abstract: Water vapor in the winter arctic stratospheric middleworld (that part of the stratosphere with potential temperatures lower than the tropical tropopause) is important for two reasons: (1) the arctic middleworld is a source of air for the upper troposphere because of the generally downward motion, and thus its water vapor content helps determine upper tropospheric water, a critical part of the earth's radiation budget; and (2) under appropriate conditions, relative humidities will be large even to the point of stratospheric cirrus cloud formation, leading to the production of active chlorine species that could destroy ozone. On a number of occasions during SOLVE, clouds were observed in the stratospheric middleworld by the DC-8 aircraft. The relationship between ozone and CO from aircraft measurements taken during the early, middle and late part of the winter of 1999-2000 show that recent mixing with tropospheric air extends up to ozone values of about 350-450 ppbv. Above that level, the relationship suggests stratospheric air with minimal tropospheric influence. The transition is quite abrupt, particularly in early spring. Trajectory analyses are consistent with these relationships, with a significant drop-off in the percentage of trajectories with tropospheric PV values in their 10-day history as in-situ ozone increases above 400 ppbv. The water distribution is affected by these mixing characteristics, and by cloud formation. Significant cloud formation along trajectories occurs up to ozone values of about 400 ppbv during the early spring, with small, but nonzero probabilities extending to 550 ppbv. Cloud formation in the stratospheric middleworld is minimal during early and midwinter. Also important is the fact that, during early spring 30% of the trajectories near the tropopause (ozone values less than 200 ppbv) have minimum saturation mixing ratios less than 5 ppmv. Such parcels can mix out into the troposphere and could lead to very dry conditions in the upper troposphere at high latitudes during spring,

Pfister, Leonhard↗

Optimal Operation and Dispatch of Voltage Regulation Devices Considering High Penetrations of Distributed Photovoltaic Generation

Voltage regulation devices have been traditionally installed and utilized to support distribution voltages. Installations of distributed energy resources (DERs) in distribution systems are rapidly increasing, and many of these generation resources have variable and uncertain power output. These generators can significantly change the voltage profile for a feeder; therefore, in the distribution system planning stage of the optimal operation and dispatch of voltage regulation devices, possible high penetrations of DERs should be considered. In this paper, we model the IEEE 34-bus test feeder, including all essential equipment. An optimization method is adopted to determine the optimal siting and operation of the voltage regulation devices in the presence of distributed solar power generation. Finally, we verify the optimal configuration of the entire system through the optimization and simulation results.

14 SOLAR ENERGY↗

Integrating Variable Renewable Energy in Power Systems: Fundamentals for the Greater Mekong Subregion

This presentation is an introduction to foundational concepts for integrating variable renewable energy (VRE) into bulk power systems, with a focus on the Greater Mekong Subregion. It contains fundamentals on challenges and solutions for VRE integration (e.g., wind and solar PV), as well as deep dives on energy storage, floating solar PV (FPV), and cross-border energy trade (CBET). Case studies are contained throughout.

Cambodia↗

On the Impact of High-Order Harmonic Generation in Electrical Distribution Systems

The modern power grid has seen a rise in the integration of non-linear loads, presenting a significant concern for operators. These loads introduce unwanted harmonics, leading to potential issues such as overheating and improper functioning of circuit breakers. In pursuing a more sustainable grid, the adoption of electric vehicles (EVs) and photovoltaic (PV) systems in residential networks has increased. Understanding and examining the effects of high-order harmonic frequencies beyond $1.5$ kHz is crucial to understanding their impact on the operation and planning of electrical distribution systems under varying nonlinear loading conditions. This study investigates a diverse set of critical power electronic loads within a household modeled using PSCAD/EMTdc, analyzing their unique harmonic spectra. This information is utilized to run the time-series harmonic analysis program in OpenDSS on a modified IEEE 34 bus test system model. The impact of high-order harmonics is quantified using metrics that evaluate total harmonic distortion (THD), transformer harmonic-driven eddy current loss component, and propagation of harmonics from the source to the substation transformer.

Peerzada, Aaqib A. [BATTELLE (PACIFIC NW LAB)]↗

Efficiency and Reliability Analyses of AC and 380V DC Distribution in Data Centers

Modern data centers consume large amounts of electricity, resulting in high operational costs. The efficiency of a data center power distribution system can be increased, and the operational cost reduced, if the number of power conversion stages can be minimized and more efficient converters, such as wide bandgap (WBG) converters, are used. This can be achieved by using DC distribution voltage at the rack level by eliminating extra conversion stages. In this paper, benchmarks for both AC and 380V DC data centers were developed and efficiency analyses were performed for an entire year. The impact of integrating photovoltaic (PV) systems into the data centers has also been analyzed in both cases in terms of efficiency. The results show that 380V DC data centers are more efficient than AC data centers with and without PV integration. Furthermore, the reliability of an AC system was compared to a 380V DC architecture with Tier-IV standard. Monte-Carlo simulations were used to perform reliability analyses for different levels of redundancy in the Uninterruptible Power Supply (UPS) system for both cases. In conclusion, the simulation results showed that the 380V DC distribution system had a higher level of reliability than the AC distribution system in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stem Inc. SunShot Incubator Program Final Technical Report

In this Energy Storage Control Algorithms project, Stem sought to develop tools and control algorithms to increase the value and reduce balance-of-system and grid integration costs associated with adding distributed solar generation to the grid. These advances fell under the headings SolarScope and SolarController. Stem sought to create initial market traction with a fully commercialized product for the solar industry to size storage systems (SolarScope) as well as a solar intermittency-mitigation framework for utilities (SolarController) in the course of the project. The company sought to align strategic growth plans and enable the rollout of the products to broader audiences in multiple geographic regions by leveraging the major solar companies in the national market as partners. Both final products were both intended to be commercialized. They are: SolarScope: Analysis tool to identify viable PV + storage projects and thereby expedite the sales and interconnection processes. SolarScope combines customer load data, PV production estimates, utility rate tariff, and simulated storage into a simple user interface for PV developers. Developers can easily identify viable solar + storage sites without the need for complex and time consuming, site-by-site spreadsheet modeling. SolarContoller: Tool to autonomously dispatch distributed storage in order to mitigate voltage fluctuation and reduce curtailment. SolarController co-optimizes, in real time, storage dispatch for circuit stability and curtailment reduction, enabling higher penetrations of PV. SolarController is automated, not requiring utility dispatch or management, as Stem hardware senses grid voltage, frequency, customer load, PV production, and power factor. In the end the two products met with different outcomes. SolarScope was tested by potential users, and continues to be used as a foundational platform for partnership with key solar industry partners. SolarController, on the other hand, was successful in lab testing but was not commercialized due to a lack of marketability and lack of interested customer base. Together the development of these two products marked a material step forward for Stem; and a new milestone along the pathway of integration for the solar and storage industries. SolarScope is leading to real, out-of-the-lab project development in storage + solar for the commercial customer sector. Meanwhile SolarController has opened the eyes of regulators and utility executives alike to the potential of distributed solar and by doing so, has moved the conversation forward for the integration of distributed energy resources more broadly on the grid.

25 ENERGY STORAGE↗

Identifying Potential Candidates for Renewable Energy Zones (REZs) in Bangladesh

Bangladesh faces several hurdles to achieving its renewable energy objectives, such as land availability and transmission congestion. Renewable Energy Zones (REZ), which are geographic areas with high-quality utility-scale renewable resources, suitable land topography, and commercial interest, can help address these challenges and support long-term generation and transmission planning. This study focuses on solar PV (fixed-tilt) and onshore wind, leveraging recently developed high temporal and spatial resolution resource data. In the moderate land exclusion scenario, large "study areas" are identified in Bangladesh with capacity factors in the top 25% for the entire country - 5 for wind and 8 for solar. Within these study areas, 19 candidates for REZ are identified based on the overlap between these study areas and upazilas (i.e., administrative subdivisions) containing economic development zones. Four of the identified candidate zones are opportunities for priority development, given the combination of strong wind and solar resources and the presence of economic zones. Furthermore, the geographic diversity of wind and solar resources in Bangladesh could help increase grid resilience by not concentrating all renewable energy development in the same region. Finally, pairing REZ with economic zones can bolster economic development, take advantage of large electricity demand, and leverage existing infrastructure investments.

Bangladesh↗

Estimating Customer Impact of Volt-Watt Using Only Smart Meter Voltage Data

The autonomous inverter control mode known as volt-watt control can be useful as a backstop against high customer voltages outside of the ranges specified in ANSI C84.1 (i.e. above 1.05-1.06 per unit). Volt-watt control mitigates high voltages by directly reducing the active power output of a distributed energy resource based on local voltage measurements. Therefore volt-watt control also can impact the energy produced by the DER (e.g. PV system), especially for customers with persistently high voltages, and in such cases it is difficult to determine exactly how much the DER has been curtailed because it is not generally known exactly how much energy the PV system could have produced. These slides propose a relatively simple method of estimating the DER's energy curtailment using only data from the utility advanced metering infrastructure (AMI) data). The method proves surprisingly accurate when validated against detailed quasi-static time-series simulations and against limited field data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Inverter Functions to Support High Levels of Distributed Solar: Policy and Regulatory Considerations (Brochure)

This paper explains how advanced inverter functions (sometimes called 'smart inverters') contribute to the integration of high levels of solar PV generation onto the electrical grid and covers the contributions of advanced functions to maintaining grid stability. Policy and regulatory considerations associated with the deployment of advanced inverter functions are also introduced.

14 SOLAR ENERGY↗

Planning for a Resilient Home Electricity Supply System

Resilience of power systems is already a key issue that is getting frequent attention all over the world. It is useful to analyze resilience issues not only for bulk supply, but at all levels including at a customer level. This is because distributed energy resources can play a prominent role in enhancing resilience. Although the literature on planning models, tools and data for bulk supply and distribution systems have expanded in recent years, customer-centric planning, e.g., for an individual household, is yet to receive adequate attention. Although solar PV and battery storage at a household level have been analyzed, how these resources can be optimally combined, together with grid supply, from a resilience perspective is the focus of this study. The study demonstrates how a conceptual framework can be developed to show the trade-off between system costs and resilience including its dimensions such as duration, depth and frequency of service outages. A planning model is developed that incorporates multiple facets of resilience and individual customer preferences. The model considers power system resilience explicitly as a constraint. The model is implemented for a household level case study in Miami, Florida. The results show there are complex trade-offs among different dimensions of resilience. The study demonstrates how combined resilience metrics can be formulated and evaluated using the proposed least-cost planning model at a household level to optimize grid supply together with solar, battery storage and diesel generators. The model allows a planner to directly embed a resilience standard to drive the optimal supply mix. These concepts and the modeling construct can also be applied at other levels of planning, including community level and bulk supply system planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of the Neutron Radius of 208 Pb Through Parity Violation in Electron Scattering

In contrast to the nuclear charge densities, which have been accurately measured with electron scattering, the knowledge of neutron densities still lack precision. Previous model-dependent hadron experiments suggest the difference between the neutron radius, R n , of a heavy nucleus and the proton radius, R p , to be in the order of several percent. To accurately obtain the difference, R n -R p , which is essentially a neutron skin, the Jefferson Lab Lead ( 208 Pb) Radius Experiment (PREX) measured the parity-violating electroweak asymmetry in the elastic scattering of polarized electrons from 208 Pb at an energy of 1.06 GeV and a scattering angle of 5° . Since Z 0 boson couples mainly to neutrons, this asymmetry provides a clean measurement of R n with respect to R p . PREX was conducted at the Jefferson lab experimental Hall A, from March to June 2010. The experiment collected a final data sample of 2x 10 7 helicity-window quadruplets. The measured parity-violating electroweak asymmetry A PV = 0.656 ± 0.060 (stat) ± 0.014 (syst) ppm corresponds to a difference between the radii of the neutron and proton distributions, R n -R p = 0.33 +0.16 -0.18 fm and provides the first electroweak observation of the neutron skin as expected in a heavy, neutron-rich nucleus. The value of the neutron radius of 208 Pb has important implications for models of nuclear structure and their application in atomic physics and astrophysics such as atomic parity non-conservation (PNC) and neutron stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Texas Solar Collaboration DOE Rooftop Solar Challenge City of Houston Project Summary

The City of Houston is committed to achieving a sustainable solar infrastructure. In 2008, Houston was named a United States Department of Energy (DOE) Solar America City. As a Solar America City, Houston teamed with the Houston Advanced Research Center (HARC), Sandia National Laboratory (Sandia), industry, and academia, to implement the Solar Houston Initiative and prepare the Solar Houston Plan. The Solar Houston initiative was focused on identifying and overcoming barriers associated with establishing a solar infrastructure that is incorporated into the City of Houston’s overall energy plan. A broad group of Houston area stakeholders, facilitated by HARC, came together to develop a comprehensive solar plan that went beyond technology to address barriers and establish demonstrations, public outreach, education programs and other activities. The plan included proposed scopes of work in four program areas: policies, solar integration, public outreach, and education. Through the support of the DOE SunShot Rooftop Solar Challenge (RSC) grant to the Texas Collaboration (San Antonio, Austin, and Hosuton), Houston has been able to implement several of the recommendations of the Solar Houston Plan. Specific recommendations that this project was able to support include; Working with the other Texas Solar America Cities (San Antonio and Austin), to harmonize permitting and inspection processes to simplify for installers and lower soft costs of installation; Participating in state level solar policy groups such as the Texas Renewable Energy Industries Association (TRIEA); Continued coordination with the local transmission and distribution utility (CenterPoint) and retail electric providers (REP); Identification of opportunities to improve permitting and interconnection; Providing training on PV systems to City inspectors; Educating the public by continuing outreach, training, and workshops, particularly using the the Green Building Resources Center; Evaluating methods of addressing financial barriers to residential solar; Maintaining www.solarhoustontx.org; and Continuing meetings with stakeholders to get ongoing feedback from the solar community on their needs. The following sections provide a brief summary of the activities completed under each of the nine tasks specifically related to the RSC grant. Reports and other backup information are included in the appendices.

14 SOLAR ENERGY↗

Advanced Research Projects Agency - Energy Annual Report for FY 2014

This report presents a summary of the activities of the Advanced Research Projects Agency-Energy (ARPA-E) during Fiscal Year 2014 (FY2014). In FY2014, ARPA-E issued funding solicitations and selected projects for three new programs covering a broad array of energy technologies, including: 27 million dollars to develop next-generation power switching devices that improve energy efficiency in a wide range of applications; 30 million dollars for hybrid solar energy beyond current photovoltaic (PV) and concentrated solar power (CSP) technologies; and 33 million dollars for electrochemical technologies to enable low-cost distributed power generation. ARPA-E released three additional funding opportunities in FY2014 with project selections that were ultimately announced in FY2015. These programs include: 30 million dollars for localized heating and cooling devices to expand temperature ranges within buildings reducing energy consumption; 30 million dollars for low-cost, high-sensitivity systems to detect and measure methane emissions; and 30 million dollars for low-cost tools to aid in the future development of fusion power. ARPA-E also continued the use of a rolling open solicitation to quickly support innovative applied energy research that has the potential to lead to new focused programs. In addition to these new programs, ARPA-E hosted the fifth annual Energy Innovation Summit from February 24-26, 2014. The Summit brought together leaders from academia, government, and business to discuss the foremost energy issues, showcase the latest technology innovations, and cultivate relationships to help advance cutting-edge technologies to market. The event drew over 2,100 attendees and featured over 120 speakers and keynote addresses. At the Summit, ARPA-E announced at least 24 ARPA-E project teams that have formed new companies and more than 16 ARPA-E projects, which have partnered with other government agencies for further development. Additionally, 22 ARPA-E projects have attracted more than 625 million dollars in private-sector follow-on funding after ARPA-E’s investment of approximately 95 million dollars. Lastly, ARPA-E continued to focus on providing awardees with practical training and critical business information as part of the Agency’s Technology-to-Market program. This support equips projects with a clear understanding of market needs to guide technical development and help projects succeed the marketplace.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

PV Field Performance Including Fleet and Bifacial Field Data

This presentation provides a review of two recent presentations - the 2021 PV Fleet Performance Data Initiative covered by the PVRW presentation, and bifacial system performance presented to a February DuraMAT working group. Details include degradation rate distributions from >6000 inverter channels, monthly performance vs expected, bifacial field studies of energy gain and field degradation.

41 EE - Solar Energy Technologies Office (EE-4S)↗