Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

System-of-Systems Approach for Integrated Energy Systems Modeling and Simulation: Preprint

Today’s electricity grid is the most complex system ever built—and the future grid is likely to be even more complex because it will incorporate distributed energy resources (DERs) such as wind, solar, and various other sources of generation and energy storage. The complexity is further augmented by the possible evolution to new retail market structures that provide incentives to owners of DERs to support the grid. To understand and test new retail market structures and technologies such as DERs, demand-response equipment, and energy management systems while providing reliable electricity to all customers, an Integrated Energy System Model (IESM) is being developed at NREL. The IESM is composed of a power flow simulator (GridLAB-D), home energy management systems implemented using GAMS/Pyomo, a market layer, and hardware-in-the-loop simulation (testing appliances such as HVAC, dishwasher, etc.). The IESM is a system-of-systems (SoS) simulator wherein the constituent systems are brought together in a virtual testbed. We will describe an SoS approach for developing a distributed simulation environment. We will elaborate on the methodology and the control mechanisms used in the co-simulation illustrated by a case study.

97 MATHEMATICS AND COMPUTING↗

Design of Fast Response Smart Electric Vehicle Charging Infrastructure

The response time of the smart electrical vehicle (EV) charging infrastructure is the key index of the system performance. The traffic between the smart EV charging station and the control center dominates the response time of the smart charging stations. To accelerate the response of the smart EV charging station, there is a need for a technology that collects the information locally and relays it to the control center periodically. To reduce the traffic between the smart EV charger and the control center, a Power Information Collector (PIC), capable of collecting all the meters power information in the charging station, is proposed and implemented in this paper. The response time is further reduced by pushing the power information to the control center. Thus, a fast response smart EV charging infrastructure is achieved to handle the shortage of energy in the local grid.

Chung, Ching-Yen↗

Demonstration of Active Power Controls by Utility-Scale PV Power Plant in an Island Grid: Preprint

The National Renewable Energy Laboratory (NREL), AES, and the Puerto Rico Electric Power Authority conducted a demonstration project on a utility-scale photovoltaic (PV) plant to test the viability of providing important ancillary services from this facility. As solar generation increases globally, there is a need for innovation and increased operational flexibility. A typical PV power plant consists of multiple power electronic inverters and can contribute to grid stability and reliability through sophisticated 'grid-friendly' controls. In this way, it may mitigate the impact of its variability on the grid and contribute to important system requirements more like traditional generators. In 2015, testing was completed on a 20-MW AES plant in Puerto Rico, and a large amount of test data was produced and analyzed that demonstrates the ability of PV power plants to provide various types of new grid-friendly controls. This data showed how active power controls can leverage PV's value from being simply an intermittent energy resource to providing additional ancillary services for an isolated island grid. Specifically, the tests conducted included PV plant participation in automatic generation control, provision of droop response, and fast frequency response.

14 SOLAR ENERGY↗

Retrieval of atmospheric properties of cloudy L dwarfs

Here, we present the first results from applying the spectral inversion technique in the cloudy L dwarf regime. This new framework provides a flexible approach to modelling cloud opacity which can be built incrementally as the data require and improves upon previous retrieval experiments in the brown dwarf regime by allowing for scattering in two-stream radiative transfer. Our first application of the tool to two mid-L dwarfs is able to reproduce their near-infrared spectra far more closely than grid models. Our retrieved thermal, chemical and cloud profiles allow us to estimate Teff = 1796 $+23\atop{-25}$ K and logg = 5.21$+0.05\atop{-0.08}$ for 2MASS J05002100+0330501, and for 2MASSW J2224438-015852 we find Teff = 1723 $+18\atop{-19}$ K and log g = 5.31 $+0.04\atop{-0.08}$, in close agreement with previous empirical estimates. Our best model for both objects includes an optically thick cloud deck which passes τcloud ≥ 1 (looking down) at a pressure of around 5 bar. The temperature at this pressure is too high for silicate species to condense, and we argue that corundum and/or iron clouds are responsible for this cloud opacity. Our retrieved profiles are cooler at depth and warmer at altitude than the forward grid models that we compare, and we argue that some form of heating mechanism may be at work in the upper atmospheres of these L dwarfs. We also identify anomalously high CO abundance in both targets, which does not correlate with the warmth of our upper atmospheres or our choice of cloud model, and find similarly anomalous alkali abundance for one of our targets. For these anomalies they may reflect unrecognized shortcomings in our retrieval model or inaccuracies in our gas phase opacities.

79 ASTRONOMY AND ASTROPHYSICS↗

Methodology for Time-Domain Estimation of Storm Time Geoelectric Fields Using the 3-D Magnetotelluric Response Tensors

Geoelectric fields at the Earth's surface caused by magnetic storms constitute a hazard to the operation of electric power grids and related infrastructure. The ability to estimate these geoelectric fields in close to real time and provide local predictions would better equip the industry to mitigate negative impacts on their operations. Here we report progress toward this goal: development of robust algorithms that convolve a magnetic storm time series with a frequency domain impedance for a realistic three-dimensional (3-D) Earth, to estimate the local, storm time geoelectric field. Both frequency domain and time domain approaches are presented and validated against storm time geoelectric field data measured in Japan. The methods are then compared in the context of a real-time application.

Kelbert, Anna↗

Data-driven Identification of Occupant Thermostat-Behavior Dynamics

Building occupant behavior drives significant differences in building energy use, even in automated buildings. Users’ distrust in the automation causes them to override settings. This results in responses that fail to satisfy both the occupants’ and/or the building automation’s objectives. The transition toward grid-interactive efficient buildings will make this evermore important as complex building control systems optimize not only for comfort, but also changing electricity costs. This paper presents a data-driven approach to study thermal comfort behavior dynamics which are not captured by standard steady-state comfort models such as predicted mean vote. The proposed model captures the time it takes for a user to override a thermostat setpoint change as a function of the manual setpoint change magnitude. The model was trained with the ecobee Donate Your Data dataset of 5 min. resolution data from 27,764 smart thermostats and occupancy sensors. The resulting population-level model shows that, on average, a 2°F override will occur after ~30 mins. and an 8°F override will occur in only ~15 mins., indicating the magnitude of discomfort as a key driver to the swiftness of an override. Such models could improve demand response programs through personalized controls.

Kane, Michael↗

Multi-Timescale Integrated Dynamics and Scheduling for Solar (MIDAS-Solar) (Final Technical Report)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power systems operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) - are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power system steady-state and dynamic performance. This project helps meet and exceed the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for power grid planning and operation. We have developed a temporally comprehensive, closed-loop simulation model, named Multi-timescale Integrated Dynamics and Scheduling (MIDAS), that seamlessly simulates power system operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). For schedules with very high levels of inverter-based resources (IBRs), up to and including 100%, the stability of grid controls has been evaluated through electromagnetic transient (EMT) simulations and power-hardware-in-the-loop (PHIL) simulations of key transient events at key schedule points. Specifically, MIDAS provides: 1) a closed-loop simulation framework for simulating timescales from economic scheduling to dynamic stability analysis; 2) machine learning-based stability assessment; 3) EMT modeling and analysis for large-scale power systems; 4) MIDAS PHIL test bed. We worked with Hawaii Electric Companies to apply the MIDAS study framework to a Maui grid study. The entire island's transmission system was modeled in detail - from a yearly scheduling model, to a second-level frequency dynamic model, down to a sub-second-scale EMT model to address critical stability issues. The project demonstrated how MIDAS can help system planners and operators assess system reliability and stability while the power grid is marching toward a high-renewable, high-IBR future. In this Maui grid study, we found that 100% instantaneous IBR operation is achievable in EMT simulation and PHIL testing, and grid planners and operators might need new analysis/simulation tools to assess grid reliability and stability in the scheduling stage. MIDAS will bring Maui and other systems closer to 100% clean and stable energy futures. (In this study, we examined transient stability. Other topics necessary for 100% IBR operation, such as protection and resource adequacy, were not examined.)

100% Renewables↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Valuation of Electric Power System Services and Technologies

Accurate valuation of existing and new technologies and grid services has been recognized to be important to stimulate investment in grid modernization. Clear, transparent, and accepted methods for estimating the total value (i.e., total benefits minus cost) of grid technologies and services are necessary for decision makers to make informed decisions. This applies to home owners interested in distributed energy technologies, as well as to service providers offering new demand response services, and utility executives evaluating best investment strategies to meet their service obligation. However, current valuation methods lack consistency, methodological rigor, and often the capabilities to identify and quantify multiple benefits of grid assets or new and innovative services. Distributed grid assets often have multiple benefits that are difficult to quantify because of the locational context in which they operate. The value is temporally, operationally, and spatially specific. It varies widely by distribution systems, transmission network topology, and the composition of the generation mix. The Electric Power Research Institute (EPRI) recently established a benefit-cost framework that proposes a process for estimating multiple benefits of distributed energy resources (DERs) and the associated cost. This document proposes an extension of this endeavor that offers a generalizable framework for valuation that quantifies the broad set of values for a wide range of technologies (including energy efficiency options, distributed resources, transmission, and generation) as well as policy options that affect all aspects of the entire generation and delivery system of the electricity infrastructure. The extension includes a comprehensive valuation framework of monetizable and non-monetizable benefits of new technologies and services beyond the traditional reliability objectives. The benefits are characterized into the following categories: sustainability, affordability, and security, flexibility, and resilience. This document defines the elements of a generic valuation framework and process as well as system properties and metrics by which value streams can be derived. The valuation process can be applied to determine the value on the margin of incremental system changes. This process is typically performed when estimating the value of a particular project (e.g., value of a merchant generator, or a distributed photovoltaic (PV) rooftop installation). Alternatively, the framework can be used when a widespread change in the grid operation, generation mix, or transmission topology is to be valued. In this case a comprehensive system analysis is required.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 1 km soil moisture dataset over eastern CONUS generated by assimilating SMAP data into the Noah-MP land surface model

An improved fine-scale soil moisture (SM) dataset at 1 km grid spacing, covering much of the eastern continental US, was generated by assimilating 9 km Soil Moisture Active Passive (SMAP) SM data into the v4.0.1 Noah-MP land surface model. With 12 ensemble members, the assimilation was carried out using the ensemble Kalman filter algorithm within NASA's Land Information System. The SM analysis for 2016 was fully validated against in situ observations from four different networks and compared with four other existing datasets. Results indicate that this SM analysis surpasses other datasets in top-layer SM distribution, including a machine-learning-based product, despite all SM estimates being less heterogeneous than observed. The analysis of anomalous errors suggests that large similarity in intrinsic errors is likely due to overlapping data sources among the selected SM datasets. More detailed evaluations were performed over two geographic areas. The observations collected by the Atmospheric Radiation Measurement facility in Oklahoma suggest that soil temperature and surface heat fluxes are concurrently simulated with good accuracy. Investigation into the 2016 southeastern US drought response further indicates drier conditions and higher evapotranspiration estimates compared to GLEAMv4.1. Notably, large errors are associated with grids having clay soil textures, underscoring the need for refined model treatments for specific soil types to further improve SM estimates. The dataset is publicly available on Zenodo at https://doi.org/10.5281/zenodo.14370563 (Tai et al., 2024).

Tai, Sheng-Lun [Pacific Northwest National Laborat↗

New York Solar Smart DG Hub-Resilient Solar Project: Economic and Resiliency Impact of PV and Storage on New York Critical Infrastructure

Resilient PV, which is solar paired with storage ('solar-plus-storage'), provides value both during normal grid operation and power outages as opposed to traditional solar PV, which functions only when the electric grid is operating. During normal grid operations, resilient PV systems help host sites generate revenue and/or reduce electricity bill charges. During grid outages, resilient PV provides critical emergency power that can help people in need and ease demand on emergency fuel supplies. The combination of grid interruptions during recent storms, the proliferation of solar PV, and the growing deployment of battery storage technologies has generated significant interest in using these assets for both economic and resiliency benefits. This report analyzes the technical and economic viability for resilient PV on three critical infrastructure sites in New York City (NYC): a school that is part of a coastal storm shelter system, a fire station, and a NYCHA senior center that serves as a cooling center during heat emergencies. This analysis differs from previous solar-plus-storage studies by placing a monetary value on resiliency and thus, in essence, modeling a new revenue stream for the avoided cost of a power outage. Analysis results show that resilient PV is economically viable for NYC's critical infrastructure and that it may be similarly beneficial to other commercial buildings across the city. This report will help city building owners, managers, and policymakers better understand the economic and resiliency benefits of resilient PV. As NYC fortifies its building stock against future storms of increasing severity, resilient PV can play an important role in disaster response and recovery while also supporting city greenhouse gas emission reduction targets and relieving stress to the electric grid from growing power demands.

14 SOLAR ENERGY↗

CHESS 2025: Spectrometer orthorectified at-sensor radiance from NEON AOP imaging spectroscopy surveys

This dataset provides Level 1 (L1) orthorectified at-sensor radiance derived from measurements collected by the Imaging Spectrometer-1 (NIS-1) onboard the NEON (National Ecological Observatory Network) Airborne Observation Platform (AOP) for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). NIS-1 captures light reflected from the Earth’s surface in 426 discrete wavelength bands as raw digital numbers (DNs; Level 0). These data are then calibrated to physical units (uW/cm²·sr·nm) following the processing steps described in the NEON Imaging Spectrometer Level 1B Calibrated Radiance Algorithm Theoretical Basis Document (ATBD; Gallery 2022). The data delivered here are the primary inputs for the surface reflectance product in “Custom surface reflectance, shade masks, and equivalent water thickness maps for the Colorado Headwaters Ecological Spectroscopy Study” (Carroll et al. 2026). For intertemporal comparison, the radiance data here are most directly relatable to the v2 radiance data in “NEON AOP Imaging Spectroscopy Survey of Upper East River Colorado Watersheds: Raw-Space Radiance and Observational Variable Dataset” (Goulden et al. 2018), to which the same processing methodology was applied. Together, the radiance and reflectance data enable users to exploit the unique reflection signatures of different surface objects for land cover classification, foliar trait mapping, plant vigor assessment, water content estimation, trace-element identification, and other scientific applications. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. Within each domain, data are delivered by flightline as orthorectified and calibrated hyperspectral rasters in Hierarchical Data Format version 5 (HDF5) format, with radiance values provided in uW/cm²·sr·nm on a fixed, uniform Universal Transverse Mercator (UTM) grid at 1 meter spatial resolution. The radiance rasters include all 426 NIS-1 spectral bands, along with associated quality-assurance (QA) and diagnostic and ancillary layers needed for atmospheric correction workflows. Orthorectified radiance is produced from pushbroom spectrometer observations by applying NEON’s radiometric calibration (including bad pixel masking, dark subtract, dark pedestal shift correction, electronic panel ghost correction, grating ghost correction, deblur correction and flat-fielding) and spectral calibration (using spectral response function band centers and full-width at half-maximum intensity), followed by geolocation and regridding to the fixed grid. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Fidelity, Large-Scale, Realistic Dataset Development

The final report summarizes the work performed for supporting the ARPA-E Grid Optimization Competition (Challenge 2 and Challenge 3) within the stated period. Challenge 2 For the challenge period, the main responsibility of the team is to investigate, gen- erate, and deliver parts of the data sets for the competition, based on the competition model for Challenge 2, existing data sets from Challenge 1, and data source supplied by other data set teams. Challenge 3 For the challenge period, the main responsibility of the team is to propose, create, deliver, and maintain the data format during the competition period. The data format will specify how the benchmark data will be represented and communicated to competitors. It will also specify how competitors should report back the solutions. The data format will be closely aligned with the problem formulation (maintained by the formulation team) and the solution validation process (maintained by the validation team). Our team is also responsible in investigating, generating, and delivering parts of the data sets for the competition. The data sets will be created based on the competition model for Challenge 3, existing data sets from Challenge 1 and Challenge 2, and data source supplied by other data set teams.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗

Weak influence of anthropogenic emissions on aerosol, cloud, and rain in the wet season of the Amazon rainforest

Anthropogenic emissions have been shown to affect new particle formation, aerosol concentrations, and clouds. Such effects vary with region, environmental conditions, and cloud types. In the wet season of Amazonia, anthropogenic emissions emitted from Manaus, Brazil, can significantly increase the cloud condensation nuclei (CCN) concentrations compared to the background of mainly natural aerosols. However, the regional response of cloud and rain to anthropogenic emissions in Amazonia remains very uncertain. Here, we aim to quantify how aerosol concentration, cloud, and rain respond to changes in anthropogenic emissions through parameterized new particle formation and primary aerosol emission in the Manaus region and to understand the underlying mechanisms. We ran the atmosphere-only configuration of the HadGEM3 climate model with a nested regional domain that covers most of the rainforest region (720 km by 1200 km with 3 km resolution) under scaled regional emissions. The 7 d simulations show that, in the areas that are affected by anthropogenic emissions, when aerosol and precursor gas emissions are doubled from the baseline emission inventories, aerosol number concentrations increase by 13 %. The nucleation rate that involves sulfuric acid and biogenic compounds generally increases with pollution levels. However, nucleation is suppressed very close to the pollution source, resulting in lower nucleation and soluble Aitken mode aerosol number concentrations. We also found that doubling the anthropogenic emission can increase the cloud droplet number concentrations ( N d ) by 9 %, but cloud water and rain mass mixing ratios do not change significantly. Even very strong reductions in aerosol number concentrations by a factor of 4, which is an unrealistic condition, cause only a 4 % increase in rain over the domain. If we assume our simulation has a fine enough grid resolution and an accurate representation of the relevant atmospheric processes, the simulated weak and non-linear response of cloud and rain properties to linearly scaled anthropogenic emissions suggests that the interactions among aerosol, cloud, and precipitation in the Amazonian convective environment are buffered by microphysical processes. It also implies that the convective environment is resilient to the changes in Nd that occur in response to localized anthropogenic aerosol perturbations.

Wang, Xuemei [University of Leeds (United Kingdom)↗

SU-E-J-91: Biomechanical Deformable Image Registration of Longitudinal Lung CT Images

Purpose: Spatial correlation of lung tissue across longitudinal images, as the patient responds to treatment, is a critical step in adaptive radiotherapy. The goal of this work is to expand a biomechanical model-based deformable registration algorithm (Morfeus) to achieve accurate registration in the presence of significant anatomical changes. Methods: Four lung cancer patients previously treated with conventionally fractionated radiotherapy that exhibited notable tumor shrinkage during treatment were retrospectively evaluated. Exhale breathhold CT scans were obtained at treatment planning (PCT) and following three weeks (W3CT) of treatment. For each patient, the PCT was registered to the W3CT using Morfeus, a biomechanical model-based deformable registration algorithm, consisting of boundary conditions on the lungs and incorporating a sliding interface between the lung and chest wall. To model the complex response of the lung, an extension to Morfeus has been developed: (i) The vessel tree was segmented by thresholding a vesselness image based on the Hessian matrix’s eigenvalues and the centerline was extracted; (ii) A 3D shape context method was used to find correspondences between the trees of the two images; (ii) Correspondences were used as additional boundary conditions (Morfeus+vBC). An expert independently identified corresponding landmarks well distributed in the lung to compute Target Registration Errors (TRE). Results: The TRE within 15mm of the tumor boundaries (on average 11 landmarks) is: 6.1±1.8, 4.6±1.1 and 3.8±2.3 mm after rigid registration, Morfeus and Morfeus+vBC, respectively. The TRE in the rest of the lung (on average 13 landmarks) is: 6.4±3.9, 4.7±2.2 and 3.6±1.9 mm, which is on the order of the 2mm isotropic dose grid vector (3.5mm). Conclusion: The addition of boundary conditions on the vessels improved the accuracy in modeling the response of the lung and tumor over the course of radiotherapy. Minimizing and modeling these geometrical uncertainties will enable future plan adaptation strategies. This work was funded in part by NIH 2P01CA059827-16.

60 APPLIED LIFE SCIENCES↗

Use Case-Informed Framework for Utility Cloud Migration

This white paper presents a comprehensive methodology for assessing utilities’ cloud postures and frameworks. It aims to produce a roadmap and strategy for a cloud-enabled grid future, providing guidance for integrators, asset owners, and operators. Instead of offering a yes or no answer for cloud implementation, this framework offers strategic guidance on responsibly preparing for and deploying cloud solutions. This paper delves into cloud-service models pertinent to the electric sector, dissecting the shared responsibility model and elucidating what on-premise infrastructure as a service (IaaS), platform as a service (PaaS), and software as a service (SaaS) entail. A pivotal consideration within the context of the shared responsibility model is the allocation of responsibility for foundational security aspects—a decision that will be informed by a comprehensive risk assessment. The ensuing discussion will present a checklist of certifications necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and with a strategic roadmap. Furthermore, the paper outlines gaps in understanding the U.S. government’s role in shaping technology development and responsible use. Its purpose is to aid decision-making by offering support for risk-informed solutions that benefit those managing assets and operating in the cloud environment. The primary objective is to enhance the resilience and future readiness of a decarbonized electric grid, with cloud solutions as one viable option. The paper synthesizes information on current and future grid architectures and applications, considering both conservative and progressive energy transitions, along with scalable and distributed computing considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗