System Identification for Integrated Aircraft Development and Flight Testing [l'Identification Des Systemes Pour le Developpement Integre des Aeronefs et les Essais en Vol]

Over the last decades flight vehicles such as aircraft and helicopters entering service and requiring increased operational effectiveness have with few exceptions experienced prolonged flight test development to achieve full certification. In many cases the original requirements had later to be reduced to enable release to service. The impact on the customer, and manufacturer has been considerable leading to increased costs and or reduced operational capabilities. These costly experiences are largely a result of the flight vehicle not behaving as modelled and designed. The evaluation of flight test data can be used as a tool for validating windtunnel results and mathematical models describing the flight dynamical behaviour. In this sense the uncertainty of important aerodynamic stability and control parameters can be reduced and the confidence of aircraft mathematical models improved. An additional important factor comes from the implementation of active control systems offering the promise of significantly increased flight vehicle performance and operational capability. This approach extends the traditional trade-offs between aerodynamics, structures and propulsion systems to include full- time, full-authority fly-by-wire/light systems. It is imperative that the aerodynamic stability and control parameters of such integrated flight and propulsion control systems have to turn out inflight as predicted, since inherent stability margins will be lower and the flight control system must correct these deficiencies to provide flight critical redundancy and safety. With the methodology of system identification from flight tests it is possible to sense the control inputs and the flight vehicle reactions Such as accelerations, rates and attitudes. The mathematical model, e.g. the model structure and parameters, has to be determined from the relationship of the measured control inputs and the system's responses. The aim of this symposium was to review the present state of the art of flight vehicle system and parameter identification techniques, and to provide a critical appraisal of current methods developed and applied to flight test data in a number of NATO nations. Particular emphasis was placed on practical aspects and lessons learned in order to generate information useful to the flight test community in industry and government agencies. The technical papers share invaluable experience and emphasize the advances of flight vehicle system identification over the last years to the point where confidence and robustness level is now reasonably high. The symposium covered overviews of identification methodologies, flight test techniques, recent aircraft and helicopter application programs, and a session of short papers covering up-to-the-minute flight test results. A final discussion included prepared comments from experts and concluded with key issues learned in the application of system identification and future research needs. The essential benefits to NATO nations can be condensed as follows: More accurate mathematical models for high bandwidth flight control systems, Improved assessment and evaluation of flying qualities, High fidelity mathematical models for flight vehicle development and mission training simulators, and generally, Reduced flight test time and costs.

Advisory Group for Aerospace Research and Developm↗

Report on the Acceptance Test of the CRI Y-MP 8128, 10 February - 12 March 1990

The NAS Numerical Aerodynamic Simulation Facility's HSP 2 computer system, a CRI Y-MP 832 SN #1002, underwent a major hardware upgrade in February of 1990. The 32 MWord, 6.3 ns mainframe component of the system was replaced with a 128 MWord, 6.0 ns CRI Y-MP 8128 mainframe, SN #1030. A 30 day Acceptance Test of the computer system was performed by the NAS RND HSP group from 08:00 February 10, 1990 to 08:00 March 12, 1990. Overall responsibility for the RND HSP Acceptance Test was assumed by Duane Carbon. The terms of the contract required that the SN #1030 achieve an effectiveness level of greater than or equal to ninety (90) percent for 30 consecutive days within a 60 day time frame. After the first thirty days, the effectiveness level of SN #1030 was 94.4 percent, hence the acceptance test was passed.

Carter, Russell↗

Testing of ENDF71x: A new ACE-formatted neutron data library based on ENDF/B-VII.1

The ENDF71x library [1] is the most thoroughly tested set of ACE-format data tables ever released by the Nuclear Data Team at Los Alamos National Laboratory (LANL). It is based on ENDF/B-VII. 1, the most recently released set of evaluated nuclear data files produced by the US Cross Section Evaluation Working Group (CSEWG). A variety of techniques were used to test and verify the ENDF7 1x library before its public release. These include the use of automated checking codes written by members of the Nuclear Data Team, visual inspections of key neutron data, MCNP6 calculations designed to test data for every included combination of isotope and temperature as comprehensively as possible, and direct comparisons between ENDF71x and previous ACE library releases. Visual inspection of some of the most important neutron data revealed energy balance problems and unphysical discontinuities in the cross sections for some nuclides. Doppler broadening of the total cross sections with increasing temperature was found to be qualitatively correct. Test calculations performed using MCNP prompted two modifications to the MCNP6 source code and also exposed bad secondary neutron yields for {sup 231,233}Pa that are present in both ENDF/B-VII.1 and ENDF/B-VII.0. A comparison of ENDF71x with its predecessor ACE library, ENDF70, showed that dramatic changes have been made in the neutron cross section data for a number of isotopes between ENDF/B-VII.0 and ENDF/B-VII.1. Based on the results of these verification tests and the validation tests performed by Kahler, et al. [2], the ENDF71x library is recommended for use in all Monte Carlo applications. (authors)

97 MATHEMATICS AND COMPUTING↗

The Local Supercluster as a test of cosmological models

The Local Supercluster kinematic properties (the Local Group infall toward the Virgo Cluster and galaxy density distribution about the Virgo Cluster) in various cosmological models are examined utilizing large-scale N-body (PM) simulations 500(exp 3) cells, 250(exp 3) particles, and box size of 400 h(exp -1) Mpc) and are compared to observations. Five models are investigated: (1) the standard, Cosmic Background Explorer Satellite (COBE)-normalized cold dark matter (CDM) model with omega = 1, h = 0.5, and sigma(sub 8) = 1.05; (2) the standard Hot Dark Matter (HDM) model with omega = 1, h = 0.75, and sigma(sub 8) = 1; (3) the tilted CDM model with omega = 1, h = 0.5, n = 0.7, and sigma(sub 8) = 0.5; (4) a CDM + lambda model with omega = 0.3, lambda = 0.7, h = 2/3, and sigma(sub 8) = 2/3; (5) the PBI model with omega = 0.2, h = 0.8, x = 0.1, m = -0.5, and sigma(sub 8) = 0.9. Comparison of the five models with the presently available observational measurements v(sub LG) = 85 - 305 km/s (with mean of 250 km/s), delta(n(sub g))/(n(sub g)-bar) = 1.40 + or - 0.35) suggests that an open universe with omega approximately 0.5 (with or without lambda) and sigma(sub 8) approximately 0.8 is preferred, with omega = 0.3-1.0 (with or without lambda) and sigma(sub 8) = 0.7-1.0 being the acceptable range. At variance with some previous claims based on either direct N-body or spherical nonlinear approaches, we find that a flat model with sigma(sub 8) approximately 0.7-1.0 seems to be reasonably consistent with observations. However, if one favors the low limit of v(sub LG) = 85 km/s, then an omega approximately 0.2-0.3 universe seems to provide a better fit, and flat (omega = 1) models are ruled out at approximately 95% confidence level. On the other hand, if the high limit of v(sub LG) = 350 km/s is closer to the truth, then it appears that omega approximately 0.7-0.8 is more consistent. This test is insensitive to the shape of the power spectrum, but rather sensitive to the normalization of the perturbation amplitude on the relevant scale (e.g., sigma(sub 8)) and omega. We find that neither linear nor nonlinear relations (with spherical symmetry) are good approximations for the relation between radial peculiar velocity and density perturbation, i.e., nonspherical effects and gravitational tidal field are important. The derived omega using either of the two relations is underestimated. In some cases, this error is as large as a factor of 2-4.

Cen, Renyue↗

Impact of Laser Fiber Design on Outcome of Endovenous Ablation of Lower-Extremity Varicose Veins: Results from a Single Practice

The design of laser fibers used for endovenous laser ablation (EVLA) in the management of lower-extremity varicose vein disease may affect treatment success. The purpose of this investigation is to report our experience using the gold-tip NeverTouch VenaCure laser fiber (AngioDynamics, Queensbury, NY) and to compare that to our experience with standard bare-tip fibers. A retrospective chart review of 363 consecutive EVLA treatments using the gold-tip laser fiber was performed. Demographic data including patient age, sex, history of previous varicose vein stripping, vein identity, laterality, treatment length, total applied energy in joules (J), use of adjuvant sclerotherapy and ambulatory phlebectomy, treatment-related complications, and treatment failure, which was defined as recanalization of any portion of the treated vein during follow-up as assessed by duplex ultrasound examination-were entered into a spreadsheet. These data were compared with a control group of 471 EVLA treatments performed with a standard bare-tip laser fiber. Data were analyzed using independent-samples Student's t test, chi-square test, and multivariate analysis. Demographic data were similar between the two groups. Treatments with the gold-tip fiber had a failure rate of 11.1%, whereas treatment with a bare-tip fiber had a failure rate of 2.3% during a similar follow-up period. This difference was highly statistically significant (p < 0.0001). Multivariate analysis showed fiber type as the most significant factor associated with treatment failure. We conclude that laser fiber design has a significant effect on treatment success in the performance of EVLA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Radiotherapy Techniques (IMRT vs. 3D-CRT) on Outcome in Patients With Intermediate-Risk Rhabdomyosarcoma Enrolled in COG D9803-A Report From the Children's Oncology Group

Purpose: To compare the dosimetric parameters of intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) in patients with intermediate-risk rhabdomyosarcoma and to analyze their effect on locoregional control and failure-free survival (FFS). Methods and Materials: The study population consisted of 375 patients enrolled in the Children's Oncology Group protocol D9803 study, receiving IMRT or 3D-CRT. Dosimetric data were collected from 179 patients with an available composite plan. The chi-square test or Fisher's exact test was used to compare the patient characteristics and radiotherapy parameters between the two groups. The interval-to-event outcomes were estimated using the Kaplan-Meier method and compared using log-rank tests. Cox proportional hazards regression analysis was used to examine the effect of the treatment technique on FFS after adjusting for primary site and risk group. Results: The median follow-up time was 5.7 and 4.2 years for patients receiving 3D-CRT and IMRT, respectively. No differences in the 5-year failure of locoregional control (18% vs. 15%) or FFS (72% vs. 76%) rates were noted between the two groups. Multivariate analysis revealed no association between the two techniques and FFS. Patients with primary tumors in parameningeal sites were more likely to receive IMRT than 3D-CRT. IMRT became more common during the later years of the study. Patients receiving IMRT were more likely to receive >50 Gy, photon energy of {<=}6 MV, and >5 radiation fields than those who received 3D-CRT. The coverage of the IMRT planning target volume by the prescription dose was improved compared with the coverage using 3D-CRT with similar target dose heterogeneity. Conclusions: IMRT improved the target dose coverage compared with 3D-CRT, although an improvement in locoregional control or FFS could not be demonstrated in this population. Future studies comparing the integral dose to nontarget tissue and late radiation toxicity between the two groups are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report: High Energy Physics at the Energy Frontier at Louisiana Tech

The Louisiana Tech University High Energy Physics group has developed a research program aimed at experimentally testing the Standard Model of particle physics and searching for new phenomena through a focused set of analyses in collaboration with the ATLAS experiment at the Large Hadron Collider (LHC) at the CERN laboratory in Geneva. This research program includes involvement in the current operation and maintenance of the ATLAS experiment and full involvement in Phase 1 and Phase 2 upgrades in preparation for future high luminosity (HL-LHC) operation of the LHC. Our focus is solely on the ATLAS experiment at the LHC, with some related detector development and software efforts. We have established important service roles on ATLAS in five major areas: Triggers, especially jet triggers; Data Quality monitoring; grid computing; GPU applications for upgrades; and radiation testing for upgrades. Our physics research is focused on multijet measurements and top quark physics in final states containing tau leptons, which we propose to extend into related searches for new phenomena. Focusing on closely related topics in the jet and top analyses and coordinating these analyses in our group has led to high efficiency and increased visibility inside the ATLAS collaboration and beyond. Based on our work in the DØ experiment in Run II of the Fermilab Tevatron Collider, Louisiana Tech has developed a reputation as one of the leading institutions pursuing jet physics studies. Currently we are applying this expertise to the ATLAS experiment, with several multijet analyses in progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies in Quantum Field Theory and Astroparticle Physics

OVERVIEW OF THE RESEARCH PLAN: Task 1: Theoretical Research in High Energy Physics Prof. Alford investigated the phases and properties of matter at the highest densities achieved in nature. His main focus was on quark matter and its manifestations and signatures in neutron stars. His work is directly relevant to both the Cosmic and the Energy Frontiers. Prof. Bender developed PT-symmetric quantum theory, which is a complex generalization of conventional Hermitian quantum theory. During the grant period, he constructed and analyzed new PT-symmetric field theoretic models that exhibit symmetry breaking. He also worked on other fundamental problems in theoretical physics. His work falls under the Intensity Frontier classification. Prof. Bernard continued to work on lattice gauge theory and associated issues in chiral perturbation theory. His research focused primarily on the calculation of weak matrix elements relevant to tests of the standard model and the search for new physics at the Intensity Frontier. This work included both direct numerical simulations in QCD and the development of theoretical tools to analyze the simulations and facilitate the comparison with Intensity-Frontier experiments. Prof. Ferrer continued working on dark matter and other topics in theoretical particle cosmology. His research focused on weakly interacting massive particles relevant to both the Cosmic and the Energy Frontiers, and on dark photons relevant to the Intensity Frontier. Prof. Ogilvie continued his work on lattice gauge theory and the phase structure of gauge theories. His research on the properties of confined, conformal and Higgs phases is relevant to the Energy Frontier, as well as addressing fundamental issues of broad theoretical interest. Task 2: Experimental Research at the Cosmic Frontier in High Energy Physics. Over the three year grant period, Profs. Buckley and Krawczynski continued research under the Cosmic Frontier. Prof. Buckley's group worked on two Cosmic Frontier projects (VERITAS and LZ), and conducted research in dark matter science and other areas of particle astrophysics. Buckley’s group worked on the conceptual design of the next generation ground-based gamma-ray experiment (CTA) and on the development of camera electronics for a 2-mirror SCT prototype telescope. Buckley's group also continued work on GaN photodetector detector development as part of the Instrumentation Frontier (Detector R&D) including work with the LAPPD group on the development robust amorphous photocathodes for very large area MCP-based photodetectors and ongoing development of deep UV photosensors for liquid Ar and Xenon Direct Dark matter detection. Prof. Krawczynski's group worked on two Cosmic Frontier topics: astrophysical tests of Lorentz Invariance and CPT symmetries at the Planck energy scale with the VERITAS gamma-ray experiment, and the search for dark matter particles with indirect detection experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Panels of HIV-1 Subtype C Env Reference Strains for Standardized Neutralization Assessments

In the search for effective immunologic interventions to prevent and treat HIV-1 infection, standardized reference reagents are a cost-effective way to maintain robustness and reproducibility among immunological assays. To support planned and ongoing studies where clade C predominates, here we describe three virus panels, chosen from 200 well-characterized clade C envelope (Env)-pseudotyped viruses from early infection. All 200 Envs were expressed as a single round of replication pseudoviruses and were tested to quantify neutralization titers by 16 broadly neutralizing antibodies (bnAbs) and sera from 30 subjects with chronic clade C infections. We selected large panels of 50 and 100 Envs either to characterize cross-reactive breadth for sera identified as having potent neutralization activity based on initial screening or to evaluate neutralization magnitude-breadth distributions of newly isolated antibodies. We identified these panels by downselection after hierarchical clustering of bnAb neutralization titers. The resulting panels represent the diversity of neutralization profiles throughout the range of virus sensitivities identified in the original panel of 200 viruses. A small 12-Env panel was chosen to screen sera from vaccine trials or natural-infection studies for neutralization responses. We considered panels selected by previously described methods but favored a computationally informed method that enabled selection of viruses representing diverse neutralization sensitivity patterns, given that we do not a priori know what the neutralization-response profile of vaccine sera will be relative to that of sera from infected individuals. The resulting 12-Env panel complements existing panels. Use of standardized panels enables direct comparisons of data from different trials and study sites testing HIV-1 clade C-specific products. HIV-1 group M includes nine clades and many recombinants. Clade C is the most common lineage, responsible for roughly half of current HIV-1 infections, and is a focus for vaccine design and testing. Standard reference reagents, particularly virus panels to study neutralization by antibodies, are crucial for developing cost-effective and yet rigorous and reproducible assays against diverse examples of this variable virus. We developed clade C-specific panels for use as standardized reagents to monitor complex polyclonal sera for neutralization activity and to characterize the potency and breadth of cross-reactive neutralization by monoclonal antibodies, whether engineered or isolated from infected individuals. We chose from 200 southern African, clade C envelope-pseudotyped viruses with neutralization titers against 16 broadly neutralizing antibodies and 30 sera from chronic clade C infections. We selected panels to represent the diversity of bnAb neutralization profiles and Env neutralization sensitivities. Finally, use of standard virus panels can facilitate comparison of results across studies and sites.

59 BASIC BIOLOGICAL SCIENCES↗

Ultra Low Sulfur Home Heating Oil Demonstration Project

This Ultra Low Sulfur (ULS) Home Heating Oil Demonstration Project was funded by the New York State Energy Research and Development Authority (NYSERDA) and has successfully quantified the environmental and economic benefits of switching to ULS (15 PPM sulfur) heating oil. It advances a prior field study of Low Sulfur (500 ppm sulfur) heating oil funded by NYSERDA and laboratory research conducted by Brookhaven National Laboratory (BNL) and Canadian researchers. The sulfur oxide and particulate matter (PM) emissions are greatly reduced as are boiler cleaning costs through extending cleaning intervals. Both the sulfur oxide and PM emission rates are directly related to the fuel oil sulfur content. The sulfur oxide and PM emission rates approach near-zero levels by switching heating equipment to ULS fuel oil, and these emissions become comparable to heating equipment fired by natural gas. This demonstration project included an in-depth review and analysis of service records for both the ULS and control groups to determine any difference in the service needs for the two groups. The detailed service records for both groups were collected and analyzed and the results were entered into two spreadsheets that enabled a quantitative side-by-side comparison of equipment service for the entire duration of the ULS test project. The service frequency for the ULS and control group were very similar and did indicate increased service frequency for the ULS group. In fact, the service frequency with the ULS group was slightly less (7.5 percent) than the control group. The only exception was that three burner fuel pump required replacement for the ULS group and none were required for the control group.

02 PETROLEUM↗

Aerocapture Guidance Algorithm Comparison Campaign

The aerocapture is a promising technique for the future human interplanetary missions. The Mars Sample Return was initially based on an insertion by aerocapture. A CNES orbiter Mars Premier was developed to demonstrate this concept. Mainly due to budget constraints, the aerocapture was cancelled for the French orbiter. A lot of studies were achieved during the three last years to develop and test different guidance algorithms (APC, EC, TPC, NPC). This work was shared between CNES and NASA, with a fruitful joint working group. To finish this study an evaluation campaign has been performed to test the different algorithms. The objective was to assess the robustness, accuracy, capability to limit the load, and the complexity of each algorithm. A simulation campaign has been specified and performed by CNES, with a similar activity on the NASA side to confirm the CNES results. This evaluation has demonstrated that the numerical guidance principal is not competitive compared to the analytical concepts. All the other algorithms are well adapted to guaranty the success of the aerocapture. The TPC appears to be the more robust, the APC the more accurate, and the EC appears to be a good compromise.

Rousseau, Stephane↗

Institute for Clean Energy Technology Mississippi State University NSR&D Aged HEPA Filter Study Final Report

Data have demonstrated that filter media lose tensile strength and the ability to resist the effects of moisture as a function of age. Testing of new and aged filters needs to be conducted to correlate reduction of physical strength of HEPA media to the ability of filters to withstand upset conditions. Appendix C of the Nuclear Air Cleaning Handbook provides the basis for DOE’s HEPA filter service life guidance. However, this appendix also points out the variability of data, and it does not correlate performance of aged filters to degradation of media due to age. Funding awarded by NSR&D to initiate full-scale testing of aged HEPA filters addresses the issue of correlating media degradation due to age with testing of new and aged HEPA filters under a generic design basis event set of conditions. This funding has accelerated the process of describing this study via: (1) establishment of a Technical Working Group of all stakeholders, (2) development and approval of a test plan, (3) development of testing and autopsy procedures, (4) acquiring an initial set of aged filters, (5) testing the initial set of aged filters, and (6) developing the filter test report content for each filter tested. This funding was very timely and has moved the project forward by at least three years. Activities have been correlated with testing conducted under DOE-EM funding for evaluating performance envelopes for AG-1 Section FC Separator and Separatorless filters. This coordination allows correlation of results from the NSR&D Aged Filter Study with results from testing new filters of the Separator and Separatorless Filter Study. DOE-EM efforts have identified approximately 100 more filters of various ages that have been stored under Level B conditions. NSR&D funded work allows a time for rigorous review among subject matter experts before moving forward with development of the testing matrix that will be used for additional filters. The NSR&D data sets are extremely valuable in as much as establishing a selfimproving, NQA-1 program capable of advancing the service lifetime study of HEPA filters. The data and reports are available for careful and critical review by subject matter experts before the next set of filters is tested and can be found in the appendices of this final report. NSR&D funds have not only initiated the Aged HEPA Filter Study alluded to in Appendix C of the NACH, but have also enhanced the technical integrity and effectiveness of all of the follow-on testing for this long-term study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Behavioral consequences of low dose radiation and sex differences in MCAT mouse model

Our study used 1-year old C57BL/6NJ male and female mice (astronaut-relevant age) that underwent exposure to 0.5 gray of gamma radiation and were euthanized 12 weeks after. In this study, we used an MCAT mouse model for mitochondrial ROS quenching, which overexpress human catalase. MCAT mice were shown to live longer and age better. Hence, in this study we determined whether quenching ROS in the mitochondria will mitigate the adverse effects of ionizing radiation exposure on spaceflight-relevant tissues. As part of the analysis, we have completed 5 different behavioral tests which focus on memory, physical stance, stress, anxiety, and other mission relevant behaviors. In the Neuro-score battery, performed after both 1and 8 weeks post IR we saw that all female groups had significantly higher scores compared to males. When comparing the baseline vs 8 weeks of radiation, we saw that all the male groups (including the sham) had lower neuro-score, pointing out to aging effect in addition to IR. In the female groups only the female IR group had lower neuro-score and the MCAT group was protected from this effect. In the Nestlet building test we saw similarly that only females were affected by radiation, having lower scores and this effect was mitigated in the MCAT animals as well. In the Catwalk test we saw that females were faster, had higher swing speed and stride length in all four paws. Males had higher stand, step cycle and max contact area. Aging is associated with slowing of gait speed, swing speed and shortening of stride length which we see in males, this is consistent with physical appearance where males look markedly older. In the Light-Dark Box test we saw that females were more frequently present in the light side and altered zones more frequently, pointing out to a more exploratory and less anxious pattern of behavior. Similarly, to what was detected in the Nest building and Neuro-score test, in the Barnes maze test, during the acquisition phase (learning) we saw that IR affected more the females who did not do better in the maze after 4 days. On the other hand, during the probe phase of the test (spatial memory) the females visited the target hole and the box quadrant more often, but also had more errors vs males, which points out to possible serial escape vs spatial escape strategy. Overall, we see that older females look physically better are faster and perform better almost in all behavioral tests compared to their male counterparts. On the other hand, they are more sensitive to low dose radiation in many cases, in some cases this effect was mitigated in the MCAT model pointing out to the importance of ROS in these stressors. In the near future we will focus on corelating these behavioral tests with molecular findings such as for example brain IHC, plasma and hippocampal cytokines in order to find specific biomarkers for behavioral deficits.

radiation↗

High-Dose Spatially Fractionated GRID Radiation Therapy (SFGRT): A Comparison of Treatment Outcomes With Cerrobend vs. MLC SFGRT

Purpose: Spatially fractionated GRID radiotherapy (SFGRT) using a customized Cerrobend block has been used to improve response rates in patients with bulky tumors. The clinical efficacy of our own multileaf collimator (MLC) technique is unknown. We undertook a retrospective analysis to compare clinical response rates attained using these two techniques. Methods and Materials: Seventy-nine patients with bulky tumors (median diameter, 7.6 cm; range, 4-30 cm) treated with SFGRT were reviewed. Between 2003 and late 2005, the Cerrobend block technique (n = 39) was used. Between late 2005 and 2008, SFGRT was delivered using MLC-shaped fields (n = 40). Dose was prescribed to dmax (depth of maximum dose) and was typically 15 Gy. Eighty percent of patients in both groups received external beam radiotherapy in addition to SFGRT. The two-sided Fisher-Freeman-Halton test was used to compare pain and mass effect response rates between the two groups. Results: Sixty-one patients (77%) were treated for palliative intent and 18 (23%) for curative intent. The majority of patients had either lung or head-and-neck primaries in both groups; the most frequent site of SFGRT application was the neck. The majority of patients complained of either pain (65%) or mass effect (58%) at intake. Overall response rates for pain and mass response were no different between the Cerrobend and MLC groups: pain, 75% and 74%, respectively (p = 0.50), and mass effect, 67% and 73%, respectively (p = 0.85). The majority of toxicities were Grade 1 or 2, and only 3 patients had late Grade 3-4 toxicities. Conclusions: MLC-based and Cerrobend-based SFGRT have comparable and encouraging response rates when used either in the palliative or curative setting. MLC-based SGFRT should allow clinics to more easily adopt this novel treatment approach for the treatment of bulky tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Basic coaxial mass driver construction and testing

A basic coaxial mass driver has been constructed by a group of students to verify performance predictions in the acceleration range envisaged for the first lunar device. The bucket is guided by four copper tubes which also supply direct current excitation for its single aluminum coil, and is accelerated by twenty coaxial coils along a 2 m track, followed by a deceleration section. The coils are individually energized by electrolytic photoflash capacitors triggered by solid state switches on the basis of bucket position.

Fine, K.↗

System Development Working Group report

The critical need is the need for funding and testing as bridging support for highly leveraged technology of Spacecraft 2000 to promote flight development introduction and acceptance. Critical needs are foreseen to augment these capabilities to satisfy specific enabling technology validation and to flight qualify selected technologies. Recommendations are summarized. This presentation is represented by figures.

Smith, William L.↗

Testing Special Relativity at High Energies with Astrophysical Sources

Since the group of Lorentz boosts is unbounded, there is a question as to whether Lorentz invariance (LI) holds to infinitely short distances. However, special and general relativity may break down at the Planck scale. Various quantum gravity scenarios such as loop quantum gravity, as well as some forms of string theory and extra dimension models may imply Lorentz violation (LV) at ultrahigh energies. The Gamma-Ray Large Area Space Telescope (GLAST), to be launched in mid-December, will measure the spectra of distant extragalactic sources of high energy gamma-rays, particularly active galactic nuclei and gamma-ray bursts. GLAST can look for energy-dependent gamma-ray propagation effects from such sources as a signal of Lorentz invariance violation. These sources may also exhibit the high energy cutoffs predicted to be the result of intergalactic annihilation interactions with low energy photons having a flux level as determined by various astronomical observations. With LV the threshold for such interactions can be significantly raised, changing the predicted absorption turnover in the observed spectrum of the sources. Stecker and Glashow have shown that the existence such absorption features in the spectra of extragalactic sources puts constraints on LV. Such constraints have important implications for some quantum gravity and large extra dimension models. Future spaceborne detectors dedicated to measuring gamma-ray polarization can look for birefringence effects as a possible signal of loop quantum gravity. A very small LV may also result in the modification or elimination of the GZK effect, thus modifying the spectrum of ultrahigh energy cosmic rays. This possibility can be explored with ground-based arrays such as Auger or with a space based detector system such as the proposed OWL satellite mission.

Stecker, F. W.↗

Cross‐Cultural Validation of the Binge Eating Disorder Screener‐7 ( BEDS ‐7) Across 42 Countries

ABSTRACT Objective This study aimed to evaluate the reliability and validity of the Binge Eating Disorder Screener‐7 (BEDS‐7) across 42 countries and 26 languages, assessing its reliability and validity as a screening tool for binge‐eating disorder (BED) in diverse cultural contexts. Specifically, it sought to enhance early recognition of BED symptoms in primary care settings globally, contributing to a standardized framework for assessing BED. Method The International Sex Survey, a cross‐sectional online study, was conducted in 42 countries and 26 languages. A diverse community sample of 82,243 participants, aged 18 years or older, completed the BEDS‐7 and measures of sexuality, mental health, substance use, and sociodemographic characteristics. Confirmatory factor analyses and tests of measurement invariance were employed to evaluate the reliability and validity of the BEDS‐7 across languages, countries, genders, and sexual orientations. Results The BEDS‐7 demonstrated scalar factorial invariance across languages and countries, indicating consistent factor loadings and item intercepts. In contrast, the screener showed residual invariance across gender and sexual orientation groups, supporting its robustness across these demographics. Kruskal–Wallis tests revealed significant differences in BED symptoms across languages, countries, genders, and sexual orientations, with the highest BED scores observed among queer, pansexual, and gender‐diverse individuals. The BEDS‐7 also demonstrated adequate reliability (Cronbach's alpha > 0.80) and moderate criterion validity. Discussion The findings provide further evidence of the reliability and validity of the BEDS‐7 as a potential screening tool for identifying probable cases of BED globally, facilitating early intervention in primary care settings.

Gewirtz‐Meydan, Ateret [School of Social Work, Fac↗