Search NASA⌕ Search

SEARCH · Search NASA

Results for “high performance visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Highlights from the Postirradiation Examination of AFC-3A and AFC-3B

Highlights from the postirradiation examination of the AFC-3A and AFC-3B irradiation test are presented. Baseline non-destructive and destructive examinations of these tests have been completed at this time. Results from visual examination, neutron radiography, gamma spectrometry, dimensional inspection, fission gas release, chemical burnup analysis, and optical microscopy have been collected. All the rodlets from these irradiations appear to have performed well during irradiation. Baseline PIE has been completed on rodlets from AFC- 3A, and AFC-3B. This includes visual exams, neutron radiography, gamma spectrometry. dimensional inspection, fission gas release evaluation, optical microscopy. microhardness evaluation. and chemical analysis. The results compiled here are a sampling of the full results. Baseline PIE provides an engineering or macroscopic scale evaluation of fuel performance and prepares samples for a more detailed phenomenological study of observed performance. Advanced PIE techniques are desired to obtain microscopic elemental and structural information both in the fuel, in the cladding, and in the interface where the composition of the FCCI layer is of great interest. The AFC-3 tests do appear to have performed roughly as designed during the irradiation. The FCCI behavior of Mo alloy metallic fuel versus Zr alloy metallic fuel has been confirmed. Results from this irradiation such as the FCCI observed in AFC-3A R1 and AFC-3A R2 can be used to eliminate Mo alloys as a choice in future irradiations where ultra-high burnup is a stated goal. Annular fuels are a preferred method for many high burnup core designs. The redistribution behavior of the annular U-Zr alloys should be studied further to better understand how this might impact high burnup annular fuel performance. The thermal bonding between annular fuel and cladding should also be studied further as there appear to be localized areas of FCCI forming in both AFC-3A R4 and AFC-3B R2, while no FCCI was observed in the Zr-based Na-bonded or Mo-based low smear density Na-bonded fuel. The performance of the low smear density. solid fuels is less clear. The neutron radiography and optical microscopy cross sections suggest the fuel is not forming a radially symmetric structure which may be causing undesirable localized temperature variations. Further study both by electron microscopy and by simulation to evaluate the implications of the non-symmetric fuel form are needed to better understand whether this fuel form merits further study under irradiation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Towards Cooperative Control of Humanoid Robots for Handling High-Consequence Materials in Gloveboxes - 17291

In this paper, we describe our ongoing work with NASA's Valkyrie humanoid robot and present preliminary results on cooperative control of Valkyrie's hands for performing dexterous manipulation tasks inside gloveboxes commonly found in many nuclear facilities. First, we discuss our human-supervised robot control framework which is based on optimization-based whole-body motion and manipulation controllers. A key aspect of this approach is perception based grasping. We develop a grasping control module for realizing the grasps corresponding to sample tasks such as power, ball, key, pinch, and open palm grasps and their variations. Next, we introduce the notion of motion template library in order to develop generalizable robot grasping and manipulation. Motion template library stores the constraint setting information for the constrained motion planning methods and a framework which can implement the motion template library on different types of robots for accomplishing similar tasks. Motion templates are defined only based on the task requirements. As a result, they can be easily ported to different robot platforms. Lastly, we discuss our multi-modal interfaces designs which include a visual display for improved situational awareness as well as a tactile glove for robot hand control and feedback. Our goal is for the person tele-operating the Valkyrie robot to have better sensing and control than what he or she would have if actually standing at the glovebox doing the work. This improved sensing is comprised of the ability to 'see through' the robot's arms and hands in the gloves and to have an improved sense of touch. The paper concludes with a discussion of our validation strategy. Our success metrics are derived from the completion of a relatively complex experiment to be performed in the glovebox. We evaluate various realistic experiments and use them for task validation and demonstration with Valkyrie. We use speed, time of completion, accuracy, repeatability and reliability rates as success metrics by designing replicable experiments. (authors)

42 ENGINEERING↗

Near Real-time Data Analysis of Core-collapse Supernova Simulations with Bellerophon

We present an overview of a software system, Bellerophon, built to support a production-level HPC application called CHIMERA, which simulates core-collapse supernova events at the petascale. Developed over the last four years, Bellerophon enables CHIMERA's geographically dispersed team of collaborators to perform data analysis in near real-time. Its n-tier architecture provides an encapsulated, end-to-end software solution that enables the CHIMERA team to quickly and easily access highly customizable animated and static views of results from anywhere in the world via a web- deliverable, cross-platform desktop application. In addition, Bellerophon addresses software engineering tasks for the CHIMERA team by providing an automated mechanism for performing regression testing on a variety of supercomputing platforms. Elements of the team's workflow management needs are met with software tools that dynamically generate code repository statistics, access important online resources, and monitor the current status of several supercomputing resources.

97 MATHEMATICS AND COMPUTING↗

Impurity gas detection for SNF canisters using probabilistic deep learning and acoustic sensing *

Abstract Monitoring impurity gases in spent nuclear fuel (SNF) canisters is a novel structural health monitoring approach for SNF in dry storage. The SNF canisters are sealed containers that do not facilitate visual access to the inside. Acoustic sensing can be deployed by taking advantage of the pathways unobstructed by internal hardware. Although the ultrasonic time-of-flight measurement can provide valuable information, it is limited in its ability to discern the concentration of only one impurity gas. As such, deep learning algorithms, particularly convolutional neural networks (CNNs), offer a promising solution. In this study, CNN-based probabilistic deep learning models were implemented to detect and quantify multiple impurity gases in helium. An experimental platform was established to simulate canister conditions, and ultrasonic test data were collected. The presence of argon and air in helium at concentrations ranging from 0% to 1.2% at increments of 0.05% was considered. The multi-layer perceptron, decision tree, and logistic regression classifiers achieved high accuracies when distinguishing pure helium from helium with impurities. CNN with dropout layers and CNN using maximum likelihood estimation showed a similar performance, indicating their ability to capture uncertainties. The ensemble CNN model exhibited improved predictions and the ability to balance individual gas concentration by integrating 1D- and 2D-CNN models. These findings contribute probabilistic deep learning solutions for impurity gas detection and analysis within SNF canisters, thus ensuring safe storage and management of SNFs.

47 OTHER INSTRUMENTATION↗

Orchestrating Distributed Resource Ensembles for Petascale Science

Distributed, data-intensive computational science applications of interest to DOE scientific com- munities move large amounts of data for experiment data management, distributed analysis steps, remote visualization, and accessing scientific instruments. These applications need to orchestrate ensembles of resources from multiple resource pools and interconnect them with high-capacity multi- layered networks across multiple domains. It is highly desirable that mechanisms are designed that provide this type of resource provisioning capability to a broad class of applications. It is also important to have coherent monitoring capabilities for such complex distributed environments. In this project, we addressed these problems by designing an abstract API, enabled by novel semantic resource descriptions, for provisioning complex and heterogeneous resources from multiple providers using their native provisioning mechanisms and control planes: computational, storage, and multi-layered high-speed network domains. We used an extensible resource representation based on semantic web technologies to afford maximum flexibility to applications in specifying their needs. We evaluated the effectiveness of provisioning using representative data-intensive ap- plications. We also developed mechanisms for providing feedback about resource performance to the application, to enable closed-loop feedback control and dynamic adjustments to resource allo- cations (elasticity). This was enabled through development of a novel persistent query framework that consumes disparate sources of monitoring data, including perfSONAR, and provides scalable distribution of asynchronous notifications.

97 MATHEMATICS AND COMPUTING↗

MO-DE-207A-09: Low-Dose CT Image Reconstruction Via Learning From Different Patient Normal-Dose Images

Purpose: To investigate a novel low-dose CT (LdCT) image reconstruction strategy for lung CT imaging in radiation therapy. Methods: The proposed approach consists of four steps: (1) use the traditional filtered back-projection (FBP) method to reconstruct the LdCT image; (2) calculate structure similarity (SSIM) index between the FBP-reconstructed LdCT image and a set of normal-dose CT (NdCT) images, and select the NdCT image with the highest SSIM as the learning source; (3) segment the NdCT source image into lung and outside tissue regions via simple thresholding, and adopt multiple linear regression to learn high-order Markov random field (MRF) pattern for each tissue region in the NdCT source image; (4) segment the FBP-reconstructed LdCT image into lung and outside regions as well, and apply the learnt MRF prior in each tissue region for statistical iterative reconstruction of the LdCT image following the penalized weighted least squares (PWLS) framework. Quantitative evaluation of the reconstructed images was based on the signal-to-noise ratio (SNR), local binary pattern (LBP) and histogram of oriented gradients (HOG) metrics. Results: It was observed that lung and outside tissue regions have different MRF patterns predicted from the NdCT. Visual inspection showed that our method obviously outperformed the traditional FBP method. Comparing with the region-smoothing PWLS method, our method has, in average, 13% increase in SNR, 15% decrease in LBP difference, and 12% decrease in HOG difference from reference standard for all regions of interest, which indicated the superior performance of the proposed method in terms of image resolution and texture preservation. Conclusion: We proposed a novel LdCT image reconstruction method by learning similar image characteristics from a set of NdCT images, and the to-be-learnt NdCT image does not need to be scans from the same subject. This approach is particularly important for enhancing image quality in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Advanced Model Development for Large Eddy Simulation of Oxy-Combustion and Supercritical Carbon Dioxide Power Cycles

A joint experimental and numerical study is performed to observe the characteristics of a supercritical carbon dioxide turbulent mixing layer in the presence of strong nonlinearities in the thermodynamic and transport properties. A bespoke experimental setup is designed and employed for this purpose and provides insight into macroscopic mixing behavior. The mixing is experimentally observed using two techniques: shadowgraphy and spontaneous Raman scattering. Qualitative and quantitative intensity fields obtained via these techniques yield instantaneous and mean density data. Spanwise temperature data is also collected using analogue resistance temperature detectors. These measurements are used to quantify the level of mixed material within the field. The experimental data are supplemented by a companion high-fidelity numerical study. The numerical results are obtained through fully resolved, three-dimensional direct numerical simulation. The numerical dataset permits observation of the near-field mixing characteristics, which are difficult to measure experimentally due to the rapid dynamics and sharp thermophysical gradients in this area. Qualitative field visualizations are presented, followed by quantitative mixed material results and observations regarding thermodynamic property trends at select locations within the field. One-dimensional spectra of the turbulent kinetic energy and solenoidal dissipation are provided to observe the spectral characteristics of the flow. Reynolds stress anisotropy is analyzed graphically through anisotropy invariance maps (Lumley triangles). The mixing quantification, spectral data and anisotropy analysis of a flow at these thermodynamic conditions represent the main outcomes of the work.

20 FOSSIL-FUELED POWER PLANTS↗

Simultaneous 3D–2D image registration and C-arm calibration: Application to endovascular image-guided interventions

Purpose: Three-dimensional to two-dimensional (3D–2D) image registration is a key to fusion and simultaneous visualization of valuable information contained in 3D pre-interventional and 2D intra-interventional images with the final goal of image guidance of a procedure. In this paper, the authors focus on 3D–2D image registration within the context of intracranial endovascular image-guided interventions (EIGIs), where the 3D and 2D images are generally acquired with the same C-arm system. The accuracy and robustness of any 3D–2D registration method, to be used in a clinical setting, is influenced by (1) the method itself, (2) uncertainty of initial pose of the 3D image from which registration starts, (3) uncertainty of C-arm’s geometry and pose, and (4) the number of 2D intra-interventional images used for registration, which is generally one and at most two. The study of these influences requires rigorous and objective validation of any 3D–2D registration method against a highly accurate reference or “gold standard” registration, performed on clinical image datasets acquired in the context of the intervention. Methods: The registration process is split into two sequential, i.e., initial and final, registration stages. The initial stage is either machine-based or template matching. The latter aims to reduce possibly large in-plane translation errors by matching a projection of the 3D vessel model and 2D image. In the final registration stage, four state-of-the-art intrinsic image-based 3D–2D registration methods, which involve simultaneous refinement of rigid-body and C-arm parameters, are evaluated. For objective validation, the authors acquired an image database of 15 patients undergoing cerebral EIGI, for which accurate gold standard registrations were established by fiducial marker coregistration. Results: Based on target registration error, the obtained success rates of 3D to a single 2D image registration after initial machine-based and template matching and final registration involving C-arm calibration were 36%, 73%, and 93%, respectively, while registration accuracy of 0.59 mm was the best after final registration. By compensating in-plane translation errors by initial template matching, the success rates achieved after the final stage improved consistently for all methods, especially if C-arm calibration was performed simultaneously with the 3D–2D image registration. Conclusions: Because the tested methods perform simultaneous C-arm calibration and 3D–2D registration based solely on anatomical information, they have a high potential for automation and thus for an immediate integration into current interventional workflow. One of the authors’ main contributions is also comprehensive and representative validation performed under realistic conditions as encountered during cerebral EIGI.

60 APPLIED LIFE SCIENCES↗

Hanford single-shell tank sidewall coring Project - 15548

As part of an enhanced Single-Shell Tank (SST) integrity project, Washington River Protection Solutions, the US DOE Hanford site Tank Operations Contractor, established an expert panel to provide recommendations for implementation of the project. In one of the main areas of interest, structural integrity, the panel recommended obtaining and testing a vertical core from the entire depth of the sidewall for SSTs that have leaked and have been operated at high temperatures for extended periods. Due to concerns over handling contaminated samples, the panel later recommended that the evaluation focus only on thermal degradation. SST 241-A-106 was selected as the best choice for sidewall coring based on heat exposure and other factors. During site preparation activities, nondestructive testing and evaluation of the exposed tank dome and sidewall was performed using impact echo, spectral analysis of surface waves, and sonic echo/impulse response acoustic wave test methods. Good results were observed in the tests performed on the dome, but results were inconclusive for the full wall height due to signal damping. Results indicated that no cracking was predicted in the upper wall. Sidewall coring of tank A-106 was completed over two weeks in May 2014. Over 38 feet of concrete core was successfully removed, to a depth approximately halfway through the tank footing. Nondestructive and destructive physical testing of the concrete core specimens was successfully performed and included visual examination and determination of transverse and longitudinal resonant frequency and dynamic modulus of elasticity; pulse velocity; static modulus of elasticity; Poisson's ratio; and compressive strength. The testing indicated favorable results with values generally greater, and in many cases significantly greater, than expected in comparison with the values originally specified and those used in the current structural analysis of record. Petrographic analysis was performed to assess the quality and condition of the concrete and the extent of any deterioration or deleterious reactions occurring within the concrete, and determined that the concrete within the examined core segments is in overall good condition, with a minor amount of microcracking and minor evidence of deleterious mechanisms that do not appear to have significantly affected the overall quality and integrity of the concrete. The results of the testing performed on the concrete core removed from the sidewall of SST 241-A-106 do not reveal any deficiencies with the structural integrity of the tank. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Visualizing Tailored Spin Phenomena in a Reduced‐Dimensional Topological Superlattice

Abstract Emergent topological insulators (TIs) and their design are in high demand for manipulating and transmitting spin information toward ultralow‐power‐consumption spintronic applications. Here, distinct topological states with tailored spin properties can be achieved in a single reduced‐dimensional TI‐superlattice, (Bi 2 /Bi 2 Se 3 )‐(Bi 2 /Bi 2 Se 3 ) N or (□/Bi 2 Se 3 )‐(Bi 2 /Bi 2 Se 3 ) N ( N is the repeating unit, □ represents an empty layer) by controlling the termination via molecular beam epitaxy. The Bi 2 ‐terminated superlattice exhibits a single Dirac cone with a spin momentum splitting ≈0.5 Å −1 , producing a pronounced inverse Edelstein effect with a coherence length up to 1.26 nm. In contrast, the Bi 2 Se 3 ‐terminated superlattice is identified as a dual TI protected by coexisting time reversal and mirror symmetries, showing an unexpectedly long spin lifetime up to 1 ns. The work elucidates the key role of dimensionality and dual topological phases in selecting desired spin properties, suggesting a promise route for engineering topological superlattices for high‐performance TI‐spintronic devices.

Sun, Rui↗

Collimator design for a multipinhole brain SPECT insert for MRI

Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations show sufficient axial sampling (in a Defrise phantom) and a reconstructed resolution of 5.0 mm (in a cold-rod phantom). The authors compared the 24-pinhole setup with a 34-pinhole system (with the same detector radius but a collimator radius of 156.63 mm) and found that 34 pinholes result in better uniformity but a worse reconstruction of the cold-rod phantom. The authors also compared the 24-pinhole system with a clinical triple-head UHR fan beam system based on contrast-to-noise ratio and found that the 24-pinhole setup performs better for the 6 mm hot and the 16 mm cold lesions and worse for the 8 and 10 mm hot lesions. Finally, the authors reconstructed noisy projection data of a Hoffman phantom with a 9 mm cold lesion and found that the lesion was slightly better visible on the multipinhole image compared to the fan beam image. Conclusions: The authors have optimized a stationary multipinhole SPECT insert for MRI and showed the feasibility of doing brain SPECT imaging inside a MRI with an image quality similar to the best clinical SPECT systems available.

60 APPLIED LIFE SCIENCES↗

Lithium Metal Battery Quality Control via Transformer–CNN Segmentation

Lithium metal battery (LMB) has the potential to be the next-generation battery system because of its high theoretical energy density. However, defects known as dendrites are formed by heterogeneous lithium (Li) plating, which hinders the development and utilization of LMBs. Non-destructive techniques to observe the dendrite morphology often use X-ray computed tomography (XCT) to provide cross-sectional views. To retrieve three-dimensional structures inside a battery, image segmentation becomes essential to quantitatively analyze XCT images. This work proposes a new semantic segmentation approach using a transformer-based neural network called TransforCNN that is capable of segmenting out dendrites from XCT data. In addition, we compare the performance of the proposed TransforCNN with three other algorithms, U-Net, Y-Net, and E-Net, consisting of an ensemble network model for XCT analysis. Our results show the advantages of using TransforCNN when evaluating over-segmentation metrics, such as mean intersection over union (mIoU) and mean Dice similarity coefficient (mDSC), as well as through several qualitatively comparative visualizations.

Quenum, Jerome (ORCID:0000000271265853)↗

Visual and energy performance of switchable windows with antireflection coatings

The aim of this project was to investigate how the visual appearance and energy performance of switchable or smart windows can be improved by using antireflective coatings. For this study clear float glass, low-e glass and electrochromic glass were treated with antireflection (AR) coatings. Such a coating considerably increases the transmittance of solar radiation in general and the visible transmittance in particular. For switchable glazing based on absorptive electrochromic layers in their dark state it is necessary to use a low-emissivity coating on the inner pane of a double glazed window in order to reject the absorbed heat. In principle all surfaces can be coated with AR coatings, and it was shown that a thin AR coating on the low-e surface neither influences the thermal emissivity nor the U-value of the glazing. The study showed that the use of AR coatings in switchable glazing significantly increases the light transmittance in the transparent state. It is believed that this is important for a high level of user acceptance of such windows. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

H-Mediated Magnetic Interactions between Layers in a 2D Mn II -Dicyanamide Polymer: Neutron Diffraction, DFT, and Quantum Monte Carlo Calculations: H-Mediated Magnetic Interactions between Layers in a 2D Mn II -Dicyanamide Polymer: Neutron Diffraction, DFT, and Quantum Monte Carlo Calculations

We report neutron-diffraction investigations of the quasi-2D Mn-II(dca)(2)(pym)(H2O) (pym = N2C4H4) compound, where high-spin Mn-II ions are bridged by dicyanamide anions, [N(CN)(2)](-) (herein abbreviated dca). Inside the layers, Mn2+ ions are connected by single or double dca bridges. The magnetic phase diagram was established by neutron diffraction on a single crystal. In the low-field phase, the Mn-II ions are antiferro-magnetically ordered in the layers, with moments nearly parallel to the c axis, and the layers are antiferromagnetically coupled. The spin-flop phase corresponds to ferromagnetic coupling between the antiferromagnetic layers, in which the Mn-II moments are nearly perpendicular to the c axis. The induced spin-density distribution in the paramagnetic phase, determined by polarized neutron diffraction, visualizes the super-exchange pathways through the dca ligands within the layers and through H bonding between neighboring layers. The theoretical spin density obtained by bidimensional periodic DFT calculations is compared with the experimental results. Furthermore, quantum Monte Carlo simulations have been performed to compare the DFT results with experimental susceptibility measurements.

density functional calculations↗

Phase I/II Multi-Institutional Study of Percutaneous Radiofrequency Ablation for Painful Osteoid Osteoma (JIVROSG-0704)

PurposeThis multicenter prospective study was conducted to evaluate the safety and efficacy of percutaneous radiofrequency ablation (RFA) for painful osteoid osteoma (OO).Materials and MethodsPatients with OO (femur: n = 17, tibia: n = 2, humerus: n = 1, rib: n = 1) were enrolled and treated with RFA. In phase I, nine patients were evaluated for safety. In phase II, 12 patients were accrued, and an intent-to-treat analysis was performed on all patients. The primary endpoint was to evaluate the treatment safety. The secondary endpoint was to evaluate the efficacy for pain relief by the visual analogue scale (VAS) at 4 weeks after RFA. Treatment efficacy was classified as significantly effective (SE) when VAS score decreased by ≥5 or score was <2, moderately effective when VAS score decreased by <5–≥2 and score was ≥2, and not effective (NE) when VAS score decreased by <2 or score was increased. Cases where the need for analgesics increased after treatment were also NE.ResultsRFA procedures were completed in all patients. Minor adverse effects (AEs) were observed as 4.8–14.3 % in 12 patients, and no major AEs were observed. Mean VAS score was 7.1 before treatment, 1.6 at 1 week, 0.3 at 4 weeks, and 0.2 at 3 months. All procedures were classified as SE. Pain recurrence was not noted in any patient during follow-up (mean: 15.1 months).ConclusionRFA is a safe, highly effective, and fast-acting treatment for painful extraspinal OO. Future studies with a greater number of patients are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthesis and evaluation of a radioiodinated peptide probe targeting αvβ6 integrin for the detection of pancreatic ductal adenocarcinoma

Highlights: • We developed a radioiodinated peptide probe targeting αvβ6 integrin ({sup 123}I-IFMDV2). • {sup 123}I-IFMDV2 had a high affinity and selectivity for αvβ6 integrin. • {sup 123}I-IFMDV2 showed a specific binding to αvβ6 integrin in vivo. • {sup 123}I-IFMDV2 enabled clear visualization of the αvβ6-integrin-positive tumor. - Abstract: Introduction: Pancreatic ductal adenocarcinoma (PDAC) remains a major cause of cancer-related death. Since significant upregulation of αvβ6 integrin has been reported in PDAC, this integrin is a promising target for PDAC detection. In this study, we aimed to develop a radioiodinated probe for the imaging of αvβ6 integrin-positive PDAC with single-photon emission computed tomography (SPECT). Methods: Four peptide probes were synthesized and screened by competitive and saturation binding assays using 2 PDAC cell lines (AsPC-1, αvβ6 integrin-positive; MIA PaCa-2, αvβ6 integrin-negative). The probe showing the best affinity was used to study the biodistribution assay, an in vivo blocking study, and SPECT imaging using tumor bearing mice. Autoradiography and immunohistochemical analysis were also performed. Results: Among the 4 probes examined in this study, {sup 125}I-IFMDV2 showed the highest affinity for αvβ6 integrin expressed in AsPC-1 cells and no affinity for MIA PaCa-2 cells. The accumulation of {sup 125}I-IFMDV2 in the AsPC-1 xenograft was 3–5 times greater than that in the MIA PaCa-2 xenograft, consistent with the expression of αvβ6 integrin in each xenograft, and confirmed by immunohistochemistry. Pretreatment with excess amounts of A20FMDV2 significantly blocked the accumulation of {sup 125}I-IFMDV2 in the AsPC-1 xenograft, but not in the MIA PaCa-2 xenograft. Furthermore, {sup 123}I-IFMDV2 enabled clear visualization of the AsPC-1 xenograft. Conclusion: {sup 123}I-IFMDV2 is a potential SPECT probe for the imaging of αvβ6 integrin in PDAC.

60 APPLIED LIFE SCIENCES↗

Data-centric framework for crystal structure identification in atomistic simulations using machine learning

Atomic-level modeling performed at large scales enables the investigation of mesoscale materials properties with atom-by-atom resolution. The spatial complexity of such cross-scale simulations renders them unsuitable for simple human visual inspection. Instead, specialized structure characterization techniques are required to aid interpretation. These have historically been challenging to construct, requiring significant intuition and effort. Here we propose an alternative framework for a fundamental structural characterization task: classifying atoms according to the crystal structure to which they belong. Our approach is data-centric and favors the employment of Machine Learning over heuristic rules of classification. A group of data-science tools and simple local descriptors of atomic structure are employed together with an efficient synthetic training set. We also introduce the first standard and publicly available benchmark data set for evaluation of algorithms for crystal-structure classification. Further, it is demonstrated that our data-centric framework outperforms all of the most popular heuristic methods—especially at high temperatures when lattices are the most distorted—while introducing a systematic route for generalization to new crystal structures. Moreover, through the use of outlier detection algorithms our approach is capable of discerning between amorphous atomic motifs (i.e., noncrystalline phases) and unknown crystal structures, making it uniquely suited for exploratory materials synthesis simulations.

36 MATERIALS SCIENCE↗

MRI of prostate brachytherapy seeds at high field: A study in phantom

Postimplant evaluation of prostate brachytherapy using magnetic resonance imaging (MRI) at 1.5 T has met with some difficulties due to the uncertainty associated with seed localization despite the excellent anatomical delineation this imaging modality can achieve. Seeds in vascularized regions or outside the prostate, where signal heterogeneity or drop off can obscure their position, can be difficult to identify. The increase in SNR available at 3.0 T offers the potential to improve these issues with visualization. However, before moving directly to in vivo studies, it is important to investigate the effects of artifact size on the ability to localize multiple seeds in close proximity. These artifacts are of extra concern at higher field because of the increased induced field distortions surrounding the seeds. A single prostate brachytherapy seed (IMC6711, OncoSeed) and arrays of seed pairs were suspended in a porcine gel medium and imaged on 1.5 and 3 T MRI scanners for comparison. Two basic acquisition techniques utilized in a wide array of clinical sequences [spin-echo based and gradient-echo (GE) based] were investigated for the types of artifacts they produce, and their dependence on field. Analysis of the resulting voids was performed to determine the relative size of seeds as seen on the images, as well as the ability to distinguish seeds at close proximity. The seed voids at 3 T were only slightly larger than those obtained at 1.5 T (0.5 mm longer and wider) when using a spin-echo type sequence. For this work, the authors used a proton density fast spin-echo (FSE) sequence. These results are promising for the use of 3 T imaging for postimplant evaluation since the SNR will increase by roughly a factor of 2 with only a limited corresponding increase in artifact size. The minimum separation of the seeds to be completely distinguished using void analysis increased from between 1.5 and 3 mm to between 3 and 4.5 mm when going from 1.5 to 3 T FSE imaging. The minimum separation of the seeds for GE at the demonstration TE of 11 ms was found to be between 3 and 4.5 mm for 1.5 T and between 4.5 and 6 mm for 3 T. These GE artifact dimensions will scale down with TE and, as this happens, approach the dimensions of the FSE artifacts given above.

62 RADIOLOGY AND NUCLEAR MEDICINE↗