Search NASA⌕ Search

SEARCH · Search NASA

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A Novel Technology for Complex Rheological Measurements - 16471

As the UK nuclear industry embarks on a second phase of nuclear power generation, the industry is faced with numerous sludge and slurry challenges associated with the decommissioning and clean-up of historical nuclear sites. The remediation of Sellafield, the largest nuclear site in the UK, is anticipated to cost GBP 53 bn over the next 100 years. Substantial cost is associated with the clean-up, transfer and safe storage of legacy particulate wastes encountered in ponds, silos, highly active storage tanks and many more large tanks on site. To develop suitable design strategies for the mobilization and transfer of sludge, the rheology of the sludge should be accurately determined. The current work demonstrates the use of a Quartz Crystal Microbalance to measure sludge rheology, specifically the shear yield stress. The device is simple to operate with no mechanical parts, small and portable enabling deployment into limited access areas, and eliminates the need for operator sampling and laboratory measurement. The measurement principle relates to the resonance frequency and motional resistance of a piezo-electric sensor as the sensor is submerged in the desired test material. The air-to-sample frequency and resistance shifts are shown to correlate with the shear yield stress of the suspension as measured by conventional vane viscometry. As the particle network stiffens (increased yield stress), the sensor motional resistance and its resonant frequency become more positive. These characteristic responses and their correlation to the shear yield stress have been confirmed for a range of particle suspensions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser-excited optical emission response of CdTe quantum dot/polymer nanocomposite under shock compression

Laser-driven shock compression experiments and corresponding finite element method simulations are carried out to investigate the blueshift in the optical emission spectra under continuous laser excitation of a dilute composite consisting of 0.15% CdTe quantum dots by weight embedded in polyvinyl alcohol polymer. This material is a potential candidate for use as internal stress sensors. The analyses focus on the time histories of the wavelength blue-shift for shock loading with pressures up to 7.3 GPa. The combined measurements and calculations allow a relation between the wavelength blueshift and pressure for the loading conditions to be extracted. It is found that the blueshift first increases with pressure to a maximum and subsequently decreases with pressure. This trend is different from the monotonic increase of blueshift with pressure observed under conditions of quasistatic hydrostatic compression. Additionally, the blueshift in the shock experiments is much smaller than that in hydrostatic experiments at the same pressure levels. The differences in responses are attributed to the different stress states achieved in the shock and hydrostatic experiments and the time dependence of the mechanical response of the polymer in the composite. The findings offer a potential guide for the design and development of materials for internal stress sensors for shock conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New portable instrument for the measurement of thermal conductivity in gas process conditions

The development of high temperature gas sensors for the monitoring and determination of thermophysical properties of complex process mixtures at high temperatures faces several problems, related with the materials compatibility, active sensing parts sensitivity, and lifetime. Ceramic/thin metal films based sensors, previously developed for the determination of thermal conductivity of molten materials up to 1200 °C, were redesigned, constructed, and applied for thermal conductivity measuring sensors. Platinum resistance thermometers were also developed using the same technology, to be used in the temperature measurement, which were also constructed and tested. A new data acquisition system for the thermal conductivity sensors, based on a linearization of the transient hot-strip model, including a portable electronic bridge for the measurement of the thermal conductivity in gas process conditions was also developed. The equipment is capable of measuring the thermal conductivity of gaseous phases with an accuracy of 2%-5% up to 840 °C (95% confidence level). The development of sensors up to 1200 °C, present at the core of the combustion chambers, will be done in a near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Processing of Functional Magnetic Materials

Functional materials, specifically those which respond to external stimuli such as magnetic and electrical field, are increasingly important for many green energy technologies. Functional magnetic materials are increasingly been investigated from basic and applied sciences perspectives. Probably, the best-known of these are permanent magnets, they are used to supply a magnetic field and are widely applied in motors, generators, data storage, sensors, and actuators. Other examples of functional materials include soft magnets, magnetocalorics, and thermoelectrics.

36 MATERIALS SCIENCE↗

Laser-based Sensors for Chemical Detection

Stand-off detection of hazardous materials ensures that the responder is located at a safe distance from the suspected source. Remote detection and identification of hazardous materials can be accomplished using a highly sensitive and portable device, at significant distances downwind from the source or the threat. Optical sensing methods, in particular infrared absorption spectroscopy combined with quantum cascade lasers (QCLs), are highly suited for the detection of chemical substances since they enable rapid detection and are amenable for autonomous operation in a compact and rugged package. This talk will discuss the sensor systems developed at Pacific Northwest National Laboratory and will discuss the progress to reduce the size and power while maintaining sensitivity to enable stand-off detection of multiple chemicals.

47 OTHER INSTRUMENTATION↗

A nano-structured ZnO film as diagnostic X-ray sensor

Currently some international organizations such as WHO and IAEA have shown concerns about the quality of diagnostic services in clinics and hospitals that use ionizing radiation. In fact, the IAEA recommend that the characteristics of the X-ray beam must be adjusted to obtain the highest quality of the radiographic image with the minimum exposure to the patient. Several types of detectors may be used for monitoring X-ray beams, such as: ionization chamber, photodiode, phototransistor, among others. Recently nano-structured films made of various types of metal oxide materials have been used for various technological applications. Accordingly, the purpose of this paper is to present a sort of device based on a nano-structured zinc oxide (ZnO) to operate as a diagnostic X-ray sensor. By depositing a thin film on the glass substrate some ZnO semiconductor samples were built by sputtering techniques and then mounted in a BNC type connector to perform the electrical characterization. To test the device, we choose a standard X-Ray beam, the RQR9 radiation quality, which is normally used as the tool and condition for calibrating diagnostic X-Ray instruments in the energy range of computed tomography, in accordance with the stated requirements of IEC 61267. A 6430 sub-femto-ammeter, Keithley, was used as electrometer to perform the output readings and simultaneously bias the ZnO sensor. Analysis of the angular dependence and the dose rate were performed to evaluate how the device responds under the RQR9 radiation spectra. Although the results have shown that the ZnO film presents a certain angular dependence, if an angle of incidence of photons is selected, the device displays reproducibility as X-ray sensor and has the feature of radiation hardness unlike other types of semiconductor electronic devices typically used as an X-ray detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FBG Sensor technology to interfacial strain measurement in cfrp-strengthened concrete beam

Fiber-reinforced polymer (FRP) composite materials are very attractive for use in strengthening of civil engineering structures because of their high strength to weight and stiffness to weight ratios, being corrosion free, light weight, and potentially high durability. The requirement for any embedded sensor for monitoring strain in FRP-strengthened concrete structures is that the sensor should not be detrimental to the operational requirement of the strengthened structure. Owing to the compatibility with FRP materials, fiber Bragg grating (FBG) sensor is a good choice for embedding at the interface of the FRP-strengthened concrete structures. As the FBG sensors are more flexible and small size (diameter = 250 μm), it may be easily instrumented at the FRP–concrete interface with sufficient surface preparation and suitable adhesive. This article deals with the issues/methods in application of FBG sensors for interfacial strain measurement of reinforced concrete beams strengthened with carbon fiber-reinforced polymer (CFRP). It also describes the experimental studies which were carried out to identify the initiation and propagation of debonding of CFRP from concrete surface using FBG array sensors.

42 ENGINEERING↗

A high-temperature heat flux sensor using the transverse Seebeck effect in elemental rhenium

Heat flux sensors compatible with hot environments are critical to advance aerospace, materials, and energy generation technologies that cope with extreme thermal conditions. In this work, we report on the development and characterization of a high-temperature heat flux sensor using the transverse Seebeck effect in rhenium single crystals. The sensor leverages refractory alloys and ceramics compatible with temperatures exceeding 1000 °C. The heat flux sensor was characterized from room temperature to 500 °C using a temperature-controlled calibration facility. At constant temperature, the sensor’s voltage output is linear with respect to the absorbed heat flux. The responsivity of the sensor varies with temperature, from 1.3 μV/(W/cm 2 ) at room temperature to −3.2 μV/(W/cm 2 ) at 500 °C, increasing monotonically in magnitude after changing sign from positive to negative at approximately 300 °C. The experimental results are in good agreement with analytical predictions of the sensor’s temperature-dependent responsivity, which suggest a further increase in magnitude up to −7.4 μV/(W/cm 2 ) at 1000 °C. These results highlight the unique characteristics of rhenium as a TSE transducer. The design offers compatibility with a wide range of operating temperatures and yields a measurement sensitivity that increases as the environmental conditions become more challenging.

20 FOSSIL-FUELED POWER PLANTS↗

Temperature, stress, and corrosive sensing apparatus utilizing harmonic response of magnetically soft sensor element (s)

A temperature sensing apparatus including a sensor element made of a magnetically soft material operatively arranged within a first and second time-varying interrogation magnetic field, the first time-varying magnetic field being generated at a frequency higher than that for the second magnetic field. A receiver, remote from the sensor element, is engaged to measure intensity of electromagnetic emissions from the sensor element to identify a relative maximum amplitude value for each of a plurality of higher-order harmonic frequency amplitudes so measured. A unit then determines a value for temperature (or other parameter of interst) using the relative maximum harmonic amplitude values identified. In other aspects of the invention, the focus is on an apparatus and technique for determining a value for of stress condition of a solid analyte and for determining a value for corrosion, using the relative maximum harmonic amplitude values identified. A magnetically hard element supporting a biasing field adjacent the magnetically soft sensor element can be included.

Grimes, Craig A.↗

A Triboelectric Sensor Array for Electrostatic Studies on the Lunar Surface

The moons electrostatic environment requires careful consideration in the development of future lunar landers. Electrostatically charged dust was well documented during the Apollo missions to cause thermal control, mechanical, and visibility issues. The fine dust particles that make up the surface are electrostatically charged as a result of numerous charging mechanisms. The relatively dry conditions on the moon creates a prime tribocharging environment during surface operations. The photoelectric effect is dominant for lunar day static charging, while plasma electrons are the main contributor for lunar night electrostatic effects. Electrostatic charging is also dependent on solar intensity, Earth-moon relative positions, and cosmic ray flux. This leads to a very complex and dynamic electrostatic environment that must be studied for the success of long term lunar missions.In order to better understand the electrostatic environment of planetary bodies, Kennedy Space Center, in previous collaboration with the Jet Propulsion Laboratory, has developed an electrostatic sensor suite. One of the instruments included in this package is the triboelectric sensor array. It is comprised of strategically selected materials that span the triboelectric series and that also have previous spaceflight history. In this presentation, we discuss detailed testing with the triboelectric sensor array performed at Kennedy Space Center. We will discuss potential benefits and use cases of this low mass, low cost sensor package, both for science and for mission success.

Charging↗

Methods and Apparatus for Detecting Defects in an Object of Interest

A method for detecting defects in an object of interest comprises applying an ultrasonic signal including a tone burst having a predetermined frequency and number of cycles into an object of interest, receiving a return signal reflected from the object of interest, and processing the return signal to detect defects in at least one inner material. The object may have an outer material and the at least one inner material that have different acoustic impedances. An ultrasonic sensor system includes an ultrasonic sensor configured to generate an ultrasonic signal having a tone burst at a predetermined frequency corresponding to a resonant frequency of an outer material of an object of interest.

Hartman, John K.↗

Optical fiber spectroscopy: A study of the luminescent properties of the europium ion for thermal sensors

Recently, there has been interest in developing a distributed temperature sensor integrated into an optical fiber. Such a system would allow embedding of the optical fiber within or on a structural material to provide for continuous monitoring of the material's temperature. Work has already begun on the development of a temperature sensor using the temperature dependent emission spectra from the lanthanide rare earths doped into crystalline hosts. The lifetime, the linewidth and the integrated intensity of this emission are each sensitive to changes in the temperature and can provide a basis for thermometry. One concept for incorporating this phenomena into an optical fiber based sensor involves bonding the optically active material to the cladding of an optical fiber and allowing the luminescent light to couple into the the fiber by the evanescent wave. Experimental work developing this concept has already been reported. Measurements of the linewidth of Eu3+:Y2O3, diffused into a fiber, made by Albin clearly show a strong and regular dependence on temperature over the range of 300 to 1000 K. We report here on a study of the temperature dependence of the lineshape of the emission at 611 nm using the data in references. We focus attention on understanding the general behavior of the Eu3+:Y2O3 system. Building upon understanding of this system we will be able to establish the physical criterial for a good optical fiber based temperature sensor and then to examine available data on other lanthanide rare earths and transition metal ions to determine the best luminescent system for temperature sensing in an optical fiber.

Buoncristiani, A. Martin↗

Superconducting calorimetric alpha particle sensors for nuclear nonproliferation applications

Identification of trace nuclear materials is usually accomplished by alpha spectrometry. Current detectors cannot distinguish critical elements and isotopes. We have developed a detector called a microcalorimeter, which achieves a resolution of 1.06 keV for 5.3 MeV alphas, the highest resolving power of any energy dispersive measurement. With this exquisite resolution, we can unambiguously identify the {sup 240}Pu/{sup 239}Pu ratio in Pu, a critical measurement for ascertaining the intended use of nuclear material. Furthermore, we have made a direct measurement of the {sup 209}Po ground state decay.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Embedding Sensors in 3D Printed Metal Structures

The Transformational Challenge Reactor (TCR) program is leveraging recent advances in modeling and simulation, materials, and additive manufacturing (AM) technologies to design a modern nuclear reactor. Some of the main TCR technologies include in situ monitoring and the integration of sensors during the manufacturing of quality-significant nuclear reactor components. This report describes the general procedure and process optimization for embedding sensors within generic stainless steel 316 (SS316) components using laser powder bed fusion (LPBF). A more detailed, quality-significant test plan and supporting procedures are available upon request (ORNL/TM-2021/2127). LPBF involves the use of a scanning laser to selectively melt regions of a powder bed, additively building a part layer by layer. This report describes the LPBF processing technique and discusses the effects of LPBF processing parameters on the success of the sensor embedding process. Experiments used machined cavities in the form of channels in an SS316 base for the sensors to lay in while material is additively built over the top, thereby embedding them in an SS316 matrix. A preliminary investigation involved using empty SS316 sheaths as surrogates to explore the effects of various LPBF processing parameters and the dimensional requirements of the machined channels. Microstructural investigations showed that a smaller channel width/depth combination closer to the sensor’s diameter was best for the embedding process. After the desired parameters were selected, Type-K thermocouples were embedded and evaluated post-embedding using nondestructive thermal testing, as well as destructive sectioning and microscopy. Post-build characterization showed that the thermocouples were well-bonded to the SS316 matrix and were fully functional after embedding. During thermal testing to temperatures up to 500 °C, the embedded thermocouples read consistently with one another and deviated only slightly from the readings of a nonembedded thermocouple located within the furnace. This slight discrepancy was most likely due to differences in the thermal time constants for a nonembedded thermocouple vs. a thermocouple embedded in a solid SS316 block. The results presented in this report will serve as the foundation for future work that will focus on embedding sensors in relevant TCR reactor components and eventually testing those components under neutron irradiation.

36 MATERIALS SCIENCE↗

Open Circuit Resonant Sensors for Composite Damage Detection and Diagnosis

Under the Integrated Vehicle Health Management (IVHM) program work was begun to investigate the feasibility of sensor systems for detecting and diagnosing damage to aircraft composite structures and materials. Specific interest for this study was in damage initiated by environmental storm hazards and the direct effect of lightning strikes on the material structures of a composite aircraft in flight. A series of open circuit resonant sensors was designed, fabricated, characterized, and determined to be a potentially viable means for damage detection and diagnosis of composite materials. The results of this research and development effort are documented in this report.

Mielnik, John J., Jr.↗

Merging of Thin- and Thick-Film Fabrication Technologies: Toward Soft Stretchable “Island-Bridge” Devices

Soft stretchable thick–thin-film devices are prepared by merging different fabrication technologies with different functional materials. The new “island–bridge” devices rely on screen-printed thick-film island electrodes, connected by thin-film serpentine interconnects. Furthermore, such a hybrid fabrication process enables to realize high-performance stretchable materials toward a new class of soft electronics with new capabilities that cannot be achieved via individual fabrication routes.

36 MATERIALS SCIENCE↗

Relationship between microstructure evolution and properties enhancement of carbon nanotubes‐filled polybutylene terephthalate/polypropylene blends induced by thermal annealing

Abstract Thermal annealing induced microstructure evolution and properties enhancement of polybutylene terephthalate/polypropylene/carbon nanotubes (PBT/PP/CNTs) nanocomposites was methodically investigated. The electrical conductive PBT/PP/CNTs nanocomposites with a low percolation threshold were obtained by simple melt blending due to the selective location of the CNTs in PBT phase and the formation of the double percolation structure. Thermal annealing further remarkably decreased the volume resistivity of the nanocomposites, with the maximum reduction of seven orders of magnitude. Scanning electron microscope observation and rheology tests demonstrated that the relatively large CNTs agglomerates were redistributed to build more homogeneous CNTs networks after annealing. The phase coalescence during annealing promoted the formation of the more perfect co‐continuous structure. These phenomena helped to enhance the electrical conductivity of the nanocomposites. Flexural properties of the nanocomposites were also enhanced after annealing, which might be due to the more effective stress transfer between the polymer and CNTs induced by the reconstructed CNTs networks. The nanocomposites obtained in this study possess excellent electrical and mechanical properties, which can be applied to the fields of sensors, electromagnetic interference shielding, anti‐static materials, and so forth.

Shang, Mengyao↗

Millimeter-scale gate-tunable graphene nanoribbon devices as a platform for mid-infrared and bio sensing applications

The experimental observation of graphene plasmon resonance has generated tremendous interest due to numerous potential applications such as photosensors, detectors, biosensors, and switches from THz to mid-infrared regime. However, practical applications require much larger dimensions (mm to cm scale) than that demonstrated in the proof-of-concept devices. Moreover, such devices also require a detailed understanding of ribbon-to-ribbon interaction, which has not been investigated so far. Here in this paper we demonstrate gate tunable plasmon resonance in the mid-infrared spectral region on millimeter-scale graphene nanoribbon (GNR) array devices fabricated using graphene monolayer. Gate dependent Fourier-transform infrared (FTIR) transmission measurements on GNR of various widths were investigated experimentally. The shift in plasmon resonance peaks of wave number 100 cm -1 at applied external gate voltage -100 V was observed. This shift is attributed to strong gate modulation. Our investigation of ribbon-to-ribbon interaction by tuning the aspect ratio reveals strong modulation of surface plasmon resonance peaks in GNR. This suggests that plasmon resonances are coupled as evidenced by blue-shifted plasmon resonance. These studies demonstrate that large-area GNR devices can serve as an ideal platform for ultrasensitive sensing and detector applications.

36 MATERIALS SCIENCE↗