Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A Radial Heat Flow Apparatus for Thermal Conductivity Characterisation of Cylindrical Samples

During the last two decades, silicon carbide based ceramic composites (SiC/SiC) have become a candidate material for nuclear fuel cladding, first for advanced nuclear systems, such as the GFR, and recently also as potential replacement material for nuclear fuel cladding in light water reactors. This work is contributing to the General Atomics/Westinghouse led CARAT project. In this frame, the thermal conductivity (TC) of cladding prototype sections are measured both before and after neutron irradiation with the purpose of better understanding the effects of neutron irradiation on the pyrolytic carbon interphase linking the SiC fibres to the SiC matrix. To this end, an apparatus has been designed and built to measure the TC of short cylindrical samples, whose lengths range from 5 to 20 cm, by the radial heat flow method. To avoid oxidation issues, the experiments are carried out in vacuum. Today the most common measurement method used to characterise the TC of materials is the so-called laser-flash technique, whereby a short high intensity laser pulse is shot on one surface of a thin flat sample and the energy transfer through the sample is analysed on the other side. Though much faster and easier to implement than the apparatus presented in this work, laser-flash equipment does have issues when dealing with highly anisotropic materials or capturing shape effects such as those present in large aspect ratio samples such as cladding tube sections. The two aforementioned effects are exactly what the developed equipment has been built to capture. The radial heat flow method is based on the principle of measuring the temperature difference building up through a piece of material as this material acts as a thermal resistance against a known heat flow crossing it. This paper presents a new implementation of one of the classical thermal conductivity measurement techniques. Since the development of the laser-flash method in the sixties, steady-state measurements such as the radial heat flow have fallen in disuse. In this discussion, it is shown that a direct measurement method can be used and even be preferable in the case of highly anisotropic materials such as SiC/SiC composites. The advantage of this experimental setup is that the actual transverse conductivity is obtained, whereas laser-flash measurements yield a response in which both the transverse and axial conductivities are mixed. Further steps of this study will include the measurements of samples irradiated with neutrons in the MITR test-reactor. The aim will be to evidence the role played by the pyrolytic carbon interphase by linking the TC measurements with energy filtered electron microscopy. We would like to acknowledge General Atomics and Westinghouse for their support in the frame of the CARAT research program. Providing us with actual prototype clad sections is a unique opportunity. Furthermore the Swiss CCEM.ch project MeAWaT is acknowledged for partially financing the development of the measurement device. (authors)

36 MATERIALS SCIENCE↗

Assessment of damage in ceramics and ceramic matrix composites using ultrasonic techniques

This paper addresses the application of ultrasonic sensing to damage assessment in ceramics and ceramic matrix composites. It focuses on damage caused by thermal shock or oxidation at elevated temperatures, which often results in elastic anisotropy. This damaged-induced anisotropy is determined by measuring the velocities of ultrasonic waves in different propagation directions. Thermal shock damage is assessed in ceramic samples of reaction bonded silicon nitride (RBSN). Thermal shock treatment from different temperatures up to 1000 C is applied to produce the microcracks. Results indicate that most microcracks produced by thermal shock are located near sample surfaces. Ultrasonic measurements using the surface wave method are found to correlate well with measurements of degradation of mechanical properties obtained independently by other authors using destructive methods. Oxidation damage is assessed in silicon carbide fiber/reaction bonded silicon nitride matrix (SCS-6/RBSN) composites. The oxidation is done by exposing the samples in a flowing oxygen environment at elevated temperatures, up to 1400 C, for 100 hr. The Youngs' modulus in the fiber direction as obtained from ultrasonic measurements decreases significantly at 600 C but retains its original value at temperatures above 1200 C. This agrees well with the results of destructive tests by other authors. On the other hand, the transverse moduli obtained from ultrasonic measurements decrease continually until 1200 C. Measurements on the shear stiffnesses show behavior similar to the transverse moduli. The results of this work show that the damage-induced anisotropy in both ceramics and ceramic matrix composites can be determined successfully by ultrasonic methods. This suggests the possibility of assessing damage severity using ultrasonic techniques.

Chu, Y. C.↗

Liquid Sampling-Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source for Elemental Mass Spectrometry: Preliminary Parametric Evaluation and Figures of Merit

A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multicanonical sampling of rare events in random matrices

A method based on multicanonical Monte Carlo is applied to the calculation of large deviations in the largest eigenvalue of random matrices. The method is successfully tested with the Gaussian orthogonal ensemble, sparse random matrices, and matrices whose components are subject to uniform density. Specifically, the probability that all eigenvalues of a matrix are negative is estimated in these cases down to the values of {approx}10{sup -200}, a region where simple random sampling is ineffective. The method can be applied to any ensemble of matrices and used for sampling rare events characterized by any statistics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extraordinary Hall effect and universal scaling in Fe{sub x}(ZnO){sub 1–x} granular thin films at room temperature

On the benefit of the concept of the so-called diluted magnetic oxides, Fe{sub x}(ZnO){sub 1–x} (x = 0.50–0.85) granular thin films with different thickness through 2D and 3D percolation region were prepared by ion beam assisted deposition. All samples are ferromagnetic at room-temperature due to the ferromagnetic nature of the Fe-doped ZnO matrix, which is quite different from the superparamagnetic behavior in the insulator-matrix based granular films. Along with decreasing thickness, the Hall coefficient R{sub S} is largely enhanced. The maximum R{sub S} reaches 4.27 × 10{sup −7} m{sup 3}/C in ∼2.8 nm Fe{sub 0.6}(ZnO){sub 0.4} granular film, which is nearly 9 times larger than the R{sub S} (4.64 × 10{sup −8} m{sup 3}/C) of the ∼50 nm Fe{sub 0.6}(ZnO){sub 0.4} sample. Meanwhile, the R{sub S} could maintain in a wide temperature region from 10 K to 300 K and the Hall sensitivity reaches ∼130 V/AT at room-temperature. The scaling exponential of n = 1.7 ± 0.1 in σ{sub xy}∼σ{sub xx}{sup n} is observed, fitting well with the recent developed universal scaling theory characterized by n = 1.6 in the dirty limit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pulmonary lobe segmentation based on ridge surface sampling and shape model fitting

Purpose: Performing lobe-based quantitative analysis of the lung in computed tomography (CT) scans can assist in efforts to better characterize complex diseases such as chronic obstructive pulmonary disease (COPD). While airways and vessels can help to indicate the location of lobe boundaries, segmentations of these structures are not always available, so methods to define the lobes in the absence of these structures are desirable. Methods: The authors present a fully automatic lung lobe segmentation algorithm that is effective in volumetric inspiratory and expiratory computed tomography (CT) datasets. The authors rely on ridge surface image features indicating fissure locations and a novel approach to modeling shape variation in the surfaces defining the lobe boundaries. The authors employ a particle system that efficiently samples ridge surfaces in the image domain and provides a set of candidate fissure locations based on the Hessian matrix. Following this, lobe boundary shape models generated from principal component analysis (PCA) are fit to the particles data to discriminate between fissure and nonfissure candidates. The resulting set of particle points are used to fit thin plate spline (TPS) interpolating surfaces to form the final boundaries between the lung lobes. Results: The authors tested algorithm performance on 50 inspiratory and 50 expiratory CT scans taken from the COPDGene study. Results indicate that the authors' algorithm performs comparably to pulmonologist-generated lung lobe segmentations and can produce good results in cases with accessory fissures, incomplete fissures, advanced emphysema, and low dose acquisition protocols. Dice scores indicate that only 29 out of 500 (5.85%) lobes showed Dice scores lower than 0.9. Two different approaches for evaluating lobe boundary surface discrepancies were applied and indicate that algorithm boundary identification is most accurate in the vicinity of fissures detectable on CT. Conclusions: The proposed algorithm is effective for lung lobe segmentation in absence of auxiliary structures such as vessels and airways. The most challenging cases are those with mostly incomplete, absent, or near-absent fissures and in cases with poorly revealed fissures due to high image noise. However, the authors observe good performance even in the majority of these cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid Determination Of Radiostrontium In Large Soil Samples

A new method for the determination of radiostrontium in large soil samples has been developed at the Savannah River Environmental Laboratory (Aiken, SC, USA) that allows rapid preconcentration and separation of strontium in large soil samples for the measurement of strontium isotopes by gas flow proportional counting. The need for rapid analyses in the event of a Radiological Dispersive Device (RDD) or Improvised Nuclear Device (IND) event is well-known. In addition, the recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid analyses for radionuclides in environmental samples in the event of a nuclear accident. The method employs a novel pre-concentration step that utilizes an iron hydroxide precipitation (enhanced with calcium phosphate) followed by a final calcium fluoride precipitation to remove silicates and other matrix components. The pre-concentration steps, in combination with a rapid Sr Resin separation using vacuum box technology, allow very large soil samples to be analyzed for {sup 89,90}Sr using gas flow proportional counting with a lower method detection limit. The calcium fluoride precipitation eliminates column flow problems typically associated with large amounts of silicates in large soil samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Transmission EBSD (t-EBSD) as Tool to Investigate Nanostructures in Superconductors

The transmission electron backscatter diffraction (t-EBSD) technique has proven to be an indispensable tool for the analysis of microstructures of superconducting samples, both high-T{sub c} samples (YBa{sub 2}Cu{sub 3}O{sub y}, Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8}) as well as MgB{sub 2} or iron-based materials. The knowledge of the grain boundary properties (misorientation, length, width) is essential for the further optimization of sample performance. Any addition of secondary phase(s) to improve the flux pinning properties is required to be of nanometer dimensions, so the higher achievable resolution and the better imaging properties are important to obtain reasonably high image quality to enable automated orientation mapping. The orientation maps reveal not only the location and the shape of the inclusions within the superconducting matrix or at the grain boundaries but also their influence on the surrounding superconducting matrix, which also plays an important role in flux pinning. In the case of sintered MgB{sub 2} bulk samples, the demand for higher critical current densities leads to MgB{sub 2} grains in the 100-nm range, which is already difficult to be studied by means of conventional EBSD. Furthermore, t-EBSD is useful for the analysis of specific microstructures of unconventional superconductors like superconducting foams or superconducting nanowire networks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The 3D Lyman- α forest power spectrum from eBOSS DR16

We measure the three-dimensional power spectrum (P3D) of the transmitted flux in the Lyman-α (Ly α) forest using the complete extended Baryon Oscillation Spectroscopic Survey data release 16 (eBOSS DR16). This sample consists of ~205 000 quasar spectra in the redshift range 2 ≤ z ≤ 4 at an effective redshift z = 2.334. We propose a pair-count spectral estimator in configuration space, weighting each pair by exp( i k ∙ r), for wave vector k and pixel pair separation r, effectively measuring the anisotropic power spectrum without the need for fast Fourier transforms. This accounts for the window matrix in a tractable way, avoiding artefacts found in Fourier-transform based power spectrum estimators due to the sparse sampling transverse to the line of sight of Ly α skewers. We extensively test our pipeline on two sets of mocks: (i) idealized Gaussian random fields with a sparse sampling of Ly α skewers, and (ii) log-normal LyaCoLoRe mocks including realistic noise levels, the eBOSS survey geometry and contaminants. On eBOSS DR16 data, the Kaiser formula with a non-linear correction term obtained from hydrodynamic simulations yields a good fit to the power spectrum data in the range $(0.02 ≤ k ≤ 0.35)$ h Mpc -1 at the 1–2σ level with a covariance matrix derived from LyaCoLoRe mocks. We demonstrate a promising new approach for full-shape cosmological analyses of Ly α forest data from cosmological surveys such as eBOSS, the currently observing Dark Energy Spectroscopic Instrument and future surveys such as the Prime Focus Spectrograph, WEAVE-QSO, and 4MOST.

79 ASTRONOMY AND ASTROPHYSICS↗

Lunar basins and craters - Evidence for systematic compositional changes of bombarding population

Of the 33 lunar samples considered in the investigation, 31 came from the North Ray Crater. The relationship between meteoritic component and rock type is studied. There appears to be some correlation between the meteoritic component, as given by the Ir/Au ratio, and the rock type, as given by the U content. The relation of ancient meteoritic components to basins and craters is examined, taking into account the resolution of groups, the relative ages from clast-matrix relations, assignments to specific basins or craters, and the relation between meteoritic components and Woenke's 'primary matter'. A table shows seven meteorite-free samples which are all low-alkali cataclastic anorthosites, or anorthositic clasts in light-matrix breccias. The origin of ancient meteoritic bodies are also investigated. The latest data strengthen earlier conclusions that the basin-forming objects were genetically related to the moon.

Hertogen, J.↗

Tailoring the optical properties of wide-bandgap based microcavities via metal films

We report on the tuning of the optical properties of II-VI-material-based microcavity samples, which is achieved by depositing Ag films on top of the structures. The micro-reflectivity spectra show a spectral shift of the sample resonance dependent on the metal layer thickness. By comparison of the experimental findings with the theoretical calculations applying the transfer matrix method on a metal-dielectric mirror structure, the influence of the metal layer particularly with regard to its partial oxidation was explored. Tamm plasmon modes are created at the interface between an open cavity with three ZnSe quantum wells and a metal layer on top. When tuning the excitonic emission relative to the mode by changing the sample temperature, an anticrossing of the resonances was observed. This is a clear indication that the strong coupling regime has been achieved in that sample configuration yielding a Rabi splitting of 18.5 meV. These results are promising for the realization of polariton-based optical devices with a rather simple sample configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Property changes induced by the space environment in composite materials on LDEF: Solar array materials passive LDEF experiment A0171 (SAMPLE)

Surface modifications to composite materials induced by long term exposure in low earth orbit (LEO) were dominated by atomic oxygen erosion and micrometeoroid and space debris impacts. As expected, calculated erosion rates were peculiar to material type and within the predicted order of magnitude. Generally, about one ply of the carbon fiber composites was eroded during the 70 month LDEF experiment. Matrix erosion was greater than fiber erosion and was more evident for a polysulfone matrix than for epoxy matrices. Micrometeoroid and space debris impacts resulted in small (less than 1mm) craters and splattered contaminants on all samples. Surfaces became more diffuse and darker with small increases in emissivity and absorption. Tensile strength decreased roughly with thickness loss, and epoxy matrices apparently became slightly embrittled, probably as a result of continued curing under UV and/or electron bombardment. However, changes in the ultimate yield stress of the carbon reinforced epoxy composites correlate neither with weave direction nor fiber type. Unexpected developments were the discovery of new synergistic effects of the space environment in the interaction of atomic oxygen and copious amounts of contamination and in the induced luminescence of many materials.

Source record↗

First Annual Progress Report on the Procurement and Post-Irradiation Examination of the Selected Samples of Alloy 800H and Grade 92 and 91 Steels

Ferritic-martensitic steel Grade 92, with Grade 91 as a reference, together with austenitic stainless steel (or Incoloy Alloy) 800H and its grain-boundary-engineered version 800H-TMP (Thermo-Mechanical Processing), is investigated in this project. A total of fifteen Grade 92 samples from two or three heats, four T91 samples from two heats, and six 800H and six 800H-TMP samples from one heat were selected, which were primarily irradiated in the Advanced Test Reactor (ATR) of Idaho National Laboratory (INL), with the rest in the High Flux Isotope Reactor (HFIR) of Oak Ridge National Laboratory (ORNL), BOR-60 of Russia, and Phénix reactor of France. The samples were irradiated in the temperature range of 241 to 720°C and a dose range of 1.28 to ~70 displacements per atom. All the INL and ORNL samples and part of the LANL (Los Alamos National Laboratory) samples have been received at the Irradiated Materials Examination and Testing (IMET) hot cell facility. The selected ORNL samples include six Grade 92 and two 800H samples, which were irradiated in the HFIR to 0.46–14.66 dpa at 400 to ~720°C. The Grade 92 is an optimized heat and named as G92-2b. The two 800H samples have one sample as the standard solution-annealed condition and the other sample as a TMP condition with a maximized fraction of low-Σ coincidence site lattice (CSL) boundaries. Tensile test of the G92-2b samples were conducted at room temperature in the IMET hot cell. The lower temperature irradiation at 400–496.7°C to 0.52–14.66 dpa resulted in minimal changes in tensile properties. However, the higher temperature irradiation at ~683.3–720°C to 0.46–14.63 dpa tended to reduce yield and tensile strength by about –136 to –311 MPa and plastic elongation by –1 to –3% with the increasing dose. The 800H and 800H-TMP samples were tensile-tested at their irradiation temperature 580°C in the IMET hot cell, which showed >40% increase in yield and tensile strength with nearly 9% reduction in elongation for 800H-TMP compared with 800H. Three of the G92-2b samples, i.e., GB04 (7.44 dpa at ~490°C), GB05 (14.66 dpa at 496.7°C), and GB12 (14.63 dpa at ~720°C), were examined at the LAMDA for Vickers hardness measurements and microstructural characterization by SEM and TEM. Vickers hardness was successfully measured on GB12, which was reduced by is – (112.4 ± 12.3) HV1 from the control sample. However, the Vickers hardness measurements were failed on GB04 and GB05 because the samples were polished too thin to prevent the interference from the substrate (epoxy). The other half of the GB04 and GB05 will be polished for the hardness measurements, as well as nanoindentation studies. Fractography by SEM indicated increased numbers of ductile dimples (or voids) with the increasing irradiation dose, while significantly increased numbers and sizes of dimples with the increasing irradiation temperature. TEM characterization exhibited the presence of Cr 23 C 6 , VN, and Laves precipitates at boundaries and matrix, which showed pronounced precipitate-dislocation interactions (pinning effect). Dense dislocations but limited dislocation loops were observed in the samples, which noticeably reduced in GB12. Additionally, some tiny partially amorphized spherical domains were observed in GB12, which had a normal body-centered cubic lattice parameter of 9Cr steels at the surround regions but ~11% smaller than the lattice parameter of the matrix away from the amorphized spherical domains. Further characterization will be pursued to clarify the new findings.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nonequilibrium defect-phase nanostructures stabilized by irradiation in undersaturated Ni-Si nanocrystalline alloy

Nanocrystalline thin films of the undersaturated alloy Ni-8.5 at% Si were subjected to 2 MeV Ti irradiation at temperatures ranging from 450˚C to 550˚C. Correlative microscopy combining transmission electron microscopy (TEM), scanning-TEM and atom probe tomography (APT revealed that large dose irradiation at 450˚C of samples with initial grain sizes below 100 nm stabilized a novel nanostructure which surprisingly contained three co-existing phases, the γ face-centered-cubic (FCC) matrix, γ' L12 ordered precipitates on intragranular dislocation loops and Ni 31 Si 12 precipitates at triple junctions (TJs). In contrast, irradiation at 550˚C and irradiation of larger grain-size samples at 450˚C only produced a γ-γ' two-phase coexistence. Analysis of the three-phase nanostructure and phase field simulations indicates that radiation-induced segregation is most pronounced at TJs, thus triggering the formation of Ni 31 Si 12 precipitates. These incoherent precipitates, in turn, are expected to stabilize the grain size under irradiation. The results are generalized using the concept of driven defect-phases. It is suggested that the stabilization of driven defect-phases may impart radiation resilience by providing localized relaxation modes to the microstructure evolution during and after temporary perturbations in irradiation conditions.

36 MATERIALS SCIENCE↗

Progress towards the FRIB-EDM 3 -Frontend: A tool to provide radioactive molecules from isotope harvesting for fundamental symmetry studies

The under-construction FRIB-EDM 3 -instrument was designed to study polar radioactive molecules (such as RaF) in transparent cryogenic solids by laser spectroscopy. The instrument is divided into a frontend- and a backend section. The frontend accepts an aqueous sample from isotope harvesting and provides a mass-separated molecular ion beam in an ultra-high vacuum environment. In the backend, the ions are guided into alkali-metal vapor and the resulting neutrals are co-deposited in a solid argon matrix to perform laser spectroscopy. Here, this work addresses the frontend of the instrument. The efficient ionization of harvested radioisotopes from aqueous samples is achieved with a spray-ionization method. Subsequently, the molecular ion beam is analyzed by mass-to-charge ratio by a quadrupole mass filter. To verify the feasibility of the approach, numerical simulations with the COMSOL and SIMION packages have been conducted. While the former was applied to study transport in ion funnels, the latter was used to investigate ion beam transmission through the lower pressure sections. Following promising simulation results, a first experimental setup is under construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrotemporal CT data acquisition and reconstruction at low dose

Purpose: X-ray computed tomography (CT) is widely used, both clinically and preclinically, for fast, high-resolution anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. The authors propose and demonstrate a projection acquisition and reconstruction strategy for 5D CT (3D + dual energy + time) which recovers spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. Methods: The authors approach the 5D reconstruction problem within the framework of low-rank and sparse matrix decomposition. Unlike previous work on rank-sparsity constrained CT reconstruction, the authors establish an explicit rank-sparse signal model to describe the spectral and temporal dimensions. The spectral dimension is represented as a well-sampled time and energy averaged image plus regularly undersampled principal components describing the spectral contrast. The temporal dimension is represented as the same time and energy averaged reconstruction plus contiguous, spatially sparse, and irregularly sampled temporal contrast images. Using a nonlinear, image domain filtration approach, the authors refer to as rank-sparse kernel regression, the authors transfer image structure from the well-sampled time and energy averaged reconstruction to the spectral and temporal contrast images. This regularization strategy strictly constrains the reconstruction problem while approximately separating the temporal and spectral dimensions. Separability results in a highly compressed representation for the 5D data in which projections are shared between the temporal and spectral reconstruction subproblems, enabling substantial undersampling. The authors solved the 5D reconstruction problem using the split Bregman method and GPU-based implementations of backprojection, reprojection, and kernel regression. Using a preclinical mouse model, the authors apply the proposed algorithm to study myocardial injury following radiation treatment of breast cancer. Results: Quantitative 5D simulations are performed using the MOBY mouse phantom. Twenty data sets (ten cardiac phases, two energies) are reconstructed with 88 μm, isotropic voxels from 450 total projections acquired over a single 360° rotation. In vivo 5D myocardial injury data sets acquired in two mice injected with gold and iodine nanoparticles are also reconstructed with 20 data sets per mouse using the same acquisition parameters (dose: ∼60 mGy). For both the simulations and the in vivo data, the reconstruction quality is sufficient to perform material decomposition into gold and iodine maps to localize the extent of myocardial injury (gold accumulation) and to measure cardiac functional metrics (vascular iodine). Their 5D CT imaging protocol represents a 95% reduction in radiation dose per cardiac phase and energy and a 40-fold decrease in projection sampling time relative to their standard imaging protocol. Conclusions: Their 5D CT data acquisition and reconstruction protocol efficiently exploits the rank-sparse nature of spectral and temporal CT data to provide high-fidelity reconstruction results without increased radiation dose or sampling time.

60 APPLIED LIFE SCIENCES↗

Aggregation of Leslie matrix models with application to ten diverse animal species

Some grouping is necessary when constructing a Leslie matrix model because it involves discretizing a continuous process of births and deaths. Here, the level of grouping is determined by the number of age classes and frequency of sampling. It is largely unknown what is lost or gained by using fewer age classes, and I address this question using aggregation theory. I derive an aggregator for a Leslie matrix model using weighted least squares, determine what properties an aggregated matrix inherits from the original matrix, evaluate aggregation error, and measure the influence of aggregation on asymptotic and transient behaviors. To gauge transient dynamics, I employ reactivity of the standardized Leslie matrix. I apply the aggregator to 10 Leslie models developed for animal populations drawn from a diverse set of species. Several properties are inherited by the aggregated matrix: (a) it is a Leslie matrix; (b) it is irreducible whenever the original matrix is irreducible; (c) it is primitive whenever the original matrix is primitive; and (d) its stable population growth rate and stable age distribution are consistent with those of the original matrix if the least squares weights are equal to the original stable age distribution. In the application, depending on the population modeled, when the least squares weights do not follow the stable age distribution, the stable population growth rate of the aggregated matrix may or may not be approximately consistent with that of the original matrix. Transient behavior is lost with high aggregation.

54 ENVIRONMENTAL SCIENCES↗

AGR-3/4 Irradiation Test Train Disassembly and Component Metrology First Look Report

The AGR-3/4 experiment was designed to study fission product transport within graphitic matrix material and nuclear-grade graphite. To this end, this experiment consisted of 12 capsules, each fueled with 4 compacts containing UCO TRISO particles as driver fuel and 20 UCO designed-to-fail (DTF) fuel particles in each compact. The DTF fuel was fabricated with a thin pyrocarbon layer which was intended to fail during irradiation and provide a source of fission products. These fission products could then migrate through the compact and into the surrounding concentric rings of graphitic matrix material and/or nuclear graphite. Through post-irradiation examination (PIE) of the rings (including physical sampling and gamma scanning) fission product concentration profiles within the rings can be determined. These data can be used to elucidate fission product transport parameters (e.g. diffusion coefficients within the test materials) which will be used to inform and refine models of fission product transport. After irradiation in the Advanced Test Reactor (ATR) had been completed in April 2014, the AGR-3/4 experiment was shipped to the Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) for inspection, disassembly, and metrology. The AGR-3/4 test train was received at MFC in two separate shipments between February and April 2015. Visual examinations of the test train exterior did not indicate dimensional distortion, and only two small discolored areas were observed at the bottom of Capsules 8 and 9. No corresponding discoloration was found on the inside of these capsules, however. Prior to disassembly, the two test train sections were subject to analysis via the Precision Gamma Scanner (PGS), which did not indicate that any gross fuel relocation had occurred. A series of specialized tools (including clamps, cutters, and drills) had been designed and fabricated in order to carry out test train disassembly and recovery of capsule components (graphite rings and fuel compacts). This equipment performed well for separating each capsule in the test train and extracting the capsule components. Only a few problems were encountered. In one case, the outermost ring (the sink ring) was cracked during removal of the capsule through tubes. Although the sink ring will be analyzed in order to obtain a mass balance of fission products in the experiment, these cracks do not pose a major concern because the sink ring will not be analyzed in detail to obtain the spatial distribution of fission products. In Capsules 4 and 5, the compacts could not be removed from the inner rings. Strategies for removing the compacts are being evaluated. Sampling the inner rings with the compacts in-place is also an option. Dimensional measurements were made on the compacts, inner rings, outer rings, and sink rings. The diameters of all compacts decreased by 0.5 to 2.0 %. Generally, the extent of diametric shrinkage increased linearly with increasing neutron fluence. Most compact lengths also decreased. Compact lengths decreased with increasing fluence, reaching maximum shrinkage of about 0.9 % at a fast fluence of 4.0x1025 n/m2 E > 0.18 MeV. Above this fluence, the extent of length shrinkage appeared to decrease with fluence, and two compacts from Capsule 7 were found to have slightly increased in length (< 0.1 %) after a fluence of 5.2x1025 n/m2.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗