Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Characterization of XR-RV3 GafChromic{sup ®} films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

Purpose: To investigate the optimal use of XR-RV3 GafChromic{sup ®} films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. Methods: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. Results: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. Conclusions: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

PARALLAX AND ORBITAL EFFECTS IN ASTROMETRIC MICROLENSING WITH BINARY SOURCES

In gravitational microlensing, binary systems may act as lenses or sources. Identifying lens binarity is generally easy, in particular in events characterized by caustic crossing since the resulting light curve exhibits strong deviations from a smooth single-lensing light curve. In contrast, light curves with minor deviations from a Paczyński behavior do not allow one to identify the source binarity. A consequence of gravitational microlensing is the shift of the position of the multiple image centroid with respect to the source star location — the so-called astrometric microlensing signal. When the astrometric signal is considered, the presence of a binary source manifests with a path that largely differs from that expected for single source events. Here, we investigate the astrometric signatures of binary sources taking into account their orbital motion and the parallax effect due to the Earth’s motion, which turn out not to be negligible in most cases. We also show that considering the above-mentioned effects is important in the analysis of astrometric data in order to correctly estimate the lens-event parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental and data analysis techniques for deducing collision-induced forces from photographic histories of engine rotor fragment impact/interaction with a containment ring

An analysis method termed TEJ-JET is described whereby measured transient elastic and inelastic deformations of an engine-rotor fragment-impacted structural ring are analyzed to deduce the transient external forces experienced by that ring as a result of fragment impact and interaction with the ring. Although the theoretical feasibility of the TEJ-JET concept was established, its practical feasibility when utilizing experimental measurements of limited precision and accuracy remains to be established. The experimental equipment and the techniques (high-speed motion photography) employed to measure the transient deformations of fragment-impacted rings are described. Sources of error and data uncertainties are identified. Techniques employed to reduce data reading uncertainties and to correct the data for optical-distortion effects are discussed. These procedures, including spatial smoothing of the deformed ring shape by Fourier series and timewise smoothing by Gram polynomials, are applied illustratively to recent measurements involving the impact of a single T58 turbine rotor blade against an aluminum containment ring. Plausible predictions of the fragment-ring impact/interaction forces are obtained by one branch of this TEJ-JET method; however, a second branch of this method, which provides an independent estimate of these forces, remains to be evaluated.

Yeghiayan, R. P.↗

The motion of throw away detectors relative to the space shuttle

The motions of throw away detectors (TAD's) are analyzed using the linearized relative motion equations. The TAD's are to be used in the amps program as diagnostic instruments for making various measurements near the shuttle. The TAD's are ejected from the shuttle in arbitrary directions with small relative velocities (0.1 to 1.0 m/s) their subsequent trajectories relative to the shuttle are analyzed. Initial conditions that are likely to result in recontact between the TAD and the shuttle are identified. The sensitivity of the motion to variations in the initial conditions, possibly resulting from inaccuracy in the ejection mechanism, are analyzed as are effects of atmospheric drag. A targeting method, a method of giving the TAD correct initial conditions such that it will pass through a given point relative to the shuttle at a given time, is developed. The results of many specific cases are presented in graphical form.

Mullins, L. D.↗

The parabolic approximation for sound propagation in a stratified moving medium

Propagation of sound in a stratified moving medium is discussed through an extension of the parabolic approximation to the acoustic equations of motion for short wavelengths. The parabolic approximation is related to the theory of geometric acoustics, and it is shown that it yields an improvement in accuracy over geometric theory. Also, the approximation corrects cumulative failures of geometric theory which occur when sound propagates many wavelengths from its source. The theory is illustrated by application to simple examples of quasi-plane wave propagation.

Myers, M. K.↗

Transonic flutter calculations using the Euler equations

In transonic flutter problems where shock motion plays an important part, it is believed that accurate predictions of the flutter boundaries will require the use of codes based on the Euler equations. Only Euler codes can obtain the correct shock location and shock strength, and the crucially important shock excursion amplitude and phase lag. The present study is based on the finite volume scheme developed by Jameson and Venkatakrishnan for the 2-D unsteady Euler equations. The equations are solved in integral form on a moving grid. The variable are pressure, density, Cartesian velocity components, and total energy.

Bendiksen, Oddvar O.↗

Validation of the dynamic response of a blade-element UH-60 simulation model in hovering flight

The dynamic fidelity of an operational blade-element simulation model of the UH-60A helicopter is assessed for the hovering and low-speed flight regimes. Nonparametric frequency-response identification techniques and time-history comparisons are used to determine the validity of vehicle responses. Frequency-domain methods are applied to the model to isolate deficiencies and verify refinements and corrections. A dedicated flight-test program was conducted to provide data used in the analyses. Model deficiencies are also identified by using side-by-side pilot assessments of a motion-based simulation and of a test aircraft. Model refinements are found to improve fidelity significantly in the frequency range of interest to handling-qualities research. The applicability of the model to high-bandwidth flight-control research is also discussed.

Ballin, Mark G.↗

Supraglacial River Forcing of Subglacial Water Storage and Diurnal Ice Sheet Motion

Surface melting impacts ice sheet sliding by supplying water to the bed, but subglacial processes driving ice accelerations are complex. We examine linkages between surface runoff, transient subglacial water storage, and short-term ice motion from 168 consecutive hourly measurements of meltwater discharge (moulin input) and GPS-derived ice surface motion for Rio Behar, a ∼60 sq. km moulin-terminating supraglacial river catchment on the southwest Greenland Ice Sheet. Short-term accelerations in ice speed correlate strongly with lag-corrected measures of supraglacial river discharge (r = 0.9, τ = 0.7, p < 0.01). Though our 7 days record cannot address seasonal-scale forcing, diurnal ice accelerations align with normalized differenced supraglacial and proglacial discharge, a proxy for subglacial storage change, better than GPS-derived ice surface uplift. These observations counter theoretical steady state basal sliding laws and suggest that moulin and proglacially induced fluctuations in subglacial water storage, rather than absolute subglacial water storage, drive short-term ice accelerations.

Glacial↗

Intrinsic Feature Motion Tracking

Subject motion during 3D medical scanning can cause blurring and artifacts in the 3D images resulting in either rescans or poor diagnosis. Anesthesia or physical restraints may be used to eliminate motion but are undesirable and can affect results. This software measures the six degree of freedom 3D motion of the subject during the scan under a rigidity assumption using only the intrinsic features present on the subject area being monitored. This movement over time can then be used to correct the scan data removing the blur and artifacts. The software acquires images from external cameras or images stored on disk for processing. The images are from two or three calibrated cameras in a stereo arrangement. Algorithms extract and track the features over time and calculate position and orientation changes relative to an initial position. Output is the 3D position and orientation change measured at each image.

Goddard, Jr., James S.↗

Quality Assurance of Ultrasound Imaging Systems for Target Localization and Online Setup Corrections

We describe quality assurance paradigms for ultrasound imaging systems for target localization (UISTL). To determine the absolute localization accuracy of a UISTL, an absolute coordinate system can be established in the treatment room and spherical targets at various depths can be localized. To test the ability of such a system to determine the magnitude of internal organ motion, a phantom that mimics the human male pelvic anatomy can be used to simulate different organ motion ranges. To assess the interuser variability of ultrasound (US) guidance, different experienced users can independently determine the daily organ shifts for the same patients for a number of consecutive fractions. The average accuracy for a UISTL for the localization of spherical targets at various depths has been found to be 0.57 {+-} 0.47 mm in each spatial dimension for various focal depths. For the phantom organ motion test it was found that the true organ motion could be determined to within 1.0 mm along each axis. The variability between different experienced users who localized the same 5 patients for five consecutive fractions was small in comparison to the indicated shifts. In addition to the quality assurance tests that address the ability of a UISTL to accurately localize a target, a thorough quality assurance program should also incorporate the following two aspects to ensure consistent and accurate localization in daily clinical use: (1) adequate training and performance monitoring of users of the US target localization system, and (2) prescreening of patients who may not be good candidates for US localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mixed quantal-semiquantal dynamics with stochastic particles for backreaction

A mixed quantal-semiquantal theory is presented in which the semiquantal squeezed-state wave packet describes the heavy degrees of freedom. Starting from the mean-field equations of motion that are naturally derived from the time-dependent variational principle, we introduce the stochastic particle description for both the quantal and semiquantal parts in an aim to take into account the interparticle correlation, in particular the “quantum backreaction” beyond the mean-field approximation. A numerical application on a model of O{sub 2} scattering from a Pt surface demonstrates that the proposed scheme gives correct asymptotic behavior of the scattering probability, with improvement over the mixed quantum-classical scheme with Bohmian particles, which is comprehended by comparing the Bohmian and the stochastic trajectories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

How electronic dynamics with Pauli exclusion produces Fermi-Dirac statistics

It is important that any dynamics method approaches the correct population distribution at long times. In this paper, we derive a one-body reduced density matrix dynamics for electrons in energetic contact with a bath. We obtain a remarkable equation of motion which shows that in order to reach equilibrium properly, rates of electron transitions depend on the density matrix. Even though the bath drives the electrons towards a Boltzmann distribution, hole blocking factors in our equation of motion cause the electronic populations to relax to a Fermi-Dirac distribution. These factors are an old concept, but we show how they can be derived with a combination of time-dependent perturbation theory and the extended normal ordering of Mukherjee and Kutzelnigg for a general electronic state. The resulting non-equilibrium kinetic equations generalize the usual Redfield theory to many-electron systems, while ensuring that the orbital occupations remain between zero and one. In numerical applications of our equations, we show that relaxation rates of molecules are not constant because of the blocking effect. Other applications to model atomic chains are also presented which highlight the importance of treating both dephasing and relaxation. Finally, we show how the bath localizes the electron density matrix.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Connection between classical and quantum descriptions of spin waves using quantum circuits

A quantum computing circuit is presented that approximates a single spin wave quantum on a linear chain of spin 1/2 particles described by a Heisenberg Hamiltonian. The circuit is a product state where each qubit represents a spin. The spin wave motion is represented by opening the cone angle using Y rotations and then adding progressive Z rotations along the chain to represent wave propagation. We show analytically that this product state yields the correct dispersion relation in the limit of an unbounded chain. This observation is confirmed using both a simulator and various quantum processors. The use of the quantum computing paradigm in this case does not lead to a computational advantage, but rather leads to a novel conceptual connection between classical and quantum descriptions of spin waves, and may also be useful for characterizing the error in quantum processors.

magnons↗

Development of Modified Perturbation Solutions to the One-Phase Stefan Problems With a Convective Boundary

The classical Stefan problem is used to track the moving solid-liquid interface during the freezing process. Perturbation theory has often been applied to find an approximate analytical solution due to the nonlinearity of the moving interface. However, the Stefan number (i.e., the sensible over latent heat) must be small and usually less than 0.01 to assume the perturbation expansion, which in turn limits the thermal engineering applications. In this study, a modified perturbation solution is developed by adding a correction term after the leading-order solution to be valid for a much wider range of Stefan numbers (i.e., 0.01 less than or equal to Ste less than or equal to 1). Specifically, a one-phase Stefan problem is first formulated subjected to a convective boundary in the Cartesian, cylindrical, and spherical coordinate systems for inward solidification. The leading-order solution is calculated based on the regular perturbation theory, while the correction term is obtained using the Monte-Carlo method and a multi-variant regression. Results show that the correction term has a linear relationship with the Stefan number and is not significantly influenced by the Biot number. The proposed modified perturbation solution can accurately and rapidly predict the nonlinear moving interface motion for the freezing process.

DIRECT ENERGY CONVERSION,MATHEMATICS AND COMPUTING↗

Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

Purpose: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).Methods: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Results: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion-blurring artifacts are present, leading to a 24.4% relative reconstruction error in the NACT phantom. View aliasing artifacts are present in 4D-CBCT reconstructed by FDK from 20 projections, with a relative error of 32.1%. When total variation minimization is used to reconstruct 4D-CBCT, the relative error is 18.9%. Image quality of 4D-CBCT is substantially improved by using the SMEIR algorithm and relative error is reduced to 7.6%. The maximum error (MaxE) of tumor motion determined from the DVF obtained by demons registration on a FDK-reconstructed 4D-CBCT is 3.0, 2.3, and 7.1 mm along left–right (L-R), anterior–posterior (A-P), and superior–inferior (S-I) directions, respectively. From the DVF obtained by demons registration on 4D-CBCT reconstructed by total variation minimization, the MaxE of tumor motion is reduced to 1.5, 0.5, and 5.5 mm along L-R, A-P, and S-I directions. From the DVF estimated by SMEIR algorithm, the MaxE of tumor motion is further reduced to 0.8, 0.4, and 1.5 mm along L-R, A-P, and S-I directions, respectively.Conclusions: The proposed SMEIR algorithm is able to estimate a motion model and reconstruct motion-compensated 4D-CBCT. The SMEIR algorithm improves image reconstruction accuracy of 4D-CBCT and tumor motion trajectory estimation accuracy as compared to conventional sequential 4D-CBCT reconstruction and motion estimation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy of the averaged description of the motion of charged particles in high-frequency fields

The accuracy of the averaged ponderomotive description of the motion of charged particles in smoothly inhomogeneous high-frequency electromagnetic fields in the nonrelativistic approximation is considered. Average equations are derived within the Hamilton perturbation theory using the technique of canonical transformations. Corrections to the ponderomotive potential, including inertial ones, i.e., those depending on the drift momentum, are found. It is shown that the change in the particle energy after the interaction with the field is exponentially small in the adiabaticity parameter gv/{omega}L.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Orientation of the earth by numerical integration

A fundamental problem is the determination of the orientation of the earth in the celestial coordinate system. Classical reductions for precession and nutation can be expected to be consistent with the present-day observations, however, corrections to the classical theory are difficult to model because of the large number of coefficients involved. Consequently, a portion of the research has been devoted to numerically integrating the Eulerian equations of motion for a rigid earth and considering the six initial conditions of the integration as unknowns. Comparison of the three adjusted Eulerian angles from the numerical integration over 1000 days indicates agreement with classical theory to within 0.003 seconds of arc.

Fajemirokun, F. A.↗