Search NASA⌕ Search

SEARCH · Search NASA

Results for “multimode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Neutron Grating Interferometry at the High Flux Isotope Reactor

Neutron imaging is a non-destructive probe that can spatially resolve bulk materials’ internal features/structures. Neutron imaging spatial resolution is driven by detector technology, i.e., pixel size, and is currently on the order of 10–20 µm. This limitation can be alleviated by the use of neutron grating interferometry – an advanced neutron imaging technique – that enables simultaneous access to three contrast mechanisms: attenuation, differential phase, and small-angle neutron scattering. Recently, a Talbot-Lau neutron grating interferometry has been implemented at the Multimodal Advanced Radiography Station at the High Flux Isotope Reactor. In this work, the design, setup and performance of the grating apparatus are presented.

Zhang, Yuxuan [ORNL] (ORCID:0000000200831408)↗

Sign problem and Monte Carlo calculations beyond Lefschetz thimbles

We point out that Monte Carlo simulations of theories with severe sign problems can be profitably performed over manifolds in complex space different from the one with fixed imaginary part of the action (“Lefschetz thimble”). We describe a family of such manifolds that interpolate between the tangent space at one critical point (where the sign problem is milder compared to the real plane but in some cases still severe) and the union of relevant thimbles (where the sign problem is mild but a multimodal distribution function complicates the Monte Carlo sampling). As a result, we exemplify this approach using a simple 0+1 dimensional fermion model previously used on sign problem studies and show that it can solve the model for some parameter values where a solution using Lefschetz thimbles was elusive.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerating template generation in resonant anomaly detection searches with optimal transport

We introduce Resonant Anomaly Detection with Optimal Transport (RAD-OT), a method for generating signal templates in resonant anomaly detection searches. RAD-OT leverages the fact that the samples from the conditional probability density of the target features vary approximately linearly along the optimal transport path connecting the resonant feature. This does not assume that the conditional density itself is linear with the resonant feature, allowing RAD-OT to efficiently capture multimodal relationships, changes in resolution, etc. By solving the optimal transport problem, RAD-OT can quickly build a template by interpolating between the background distributions in two sideband regions. We demonstrate the performance of RAD-OT using the LHC Olympics R&D dataset, where we find comparable sensitivity and improved stability with respect to deep learning-based approaches.

Automation↗

Large-eddy and unsteady RANS simulations of a shock-accelerated heavy gas cylinder

Two-dimensional numerical simulations of the Richtmyer–Meshkov unstable “shock-jet” problem are conducted using both large-eddy simulation (LES) and unsteady Reynolds-averaged Navier–Stokes (URANS) approaches in an arbitrary Lagrangian–Eulerian hydrodynamics code. Turbulence statistics are extracted from LES by running an ensemble of simulations with multimode perturbations to the initial conditions. Detailed grid convergence studies are conducted, and LES results are found to agree well with both experiment and high-order simulations conducted by Shankar et al. (Phys Fluids 23, 024102, 2011). URANS results using a k–L approach are found to be highly sensitive to initialization of the turbulence lengthscale L and to the time at which L becomes resolved on the computational mesh. As a result, it is observed that a gradient diffusion closure for turbulent species flux is a poor approximation at early times, and a new closure based on the mass-flux velocity is proposed for low-Reynolds-number mixing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fluorescence-coupled micropipette aspiration assay to examine calcium mobilization caused by red blood cell mechanosensing

Abstract Mechanical stimuli such as tension, compression, and shear stress play critical roles in the physiological functions of red blood cells (RBCs) and their homeostasis, ATP release, and rheological properties. Intracellular calcium (Ca 2+ ) mobilization reflects RBC mechanosensing as they transverse the complex vasculature. Emerging studies have demonstrated the presence of mechanosensitive Ca 2+ permeable ion channels and their function has been implicated in the regulation of RBC volume and deformability. However, how these mechanoreceptors trigger Ca 2+ influx and subsequent cellular responses are still unclear. Here, we introduce a fluorescence-coupled micropipette aspiration assay to examine RBC mechanosensing at the single-cell level. To achieve a wide range of cell aspirations, we implemented and compared two negative pressure adjusting apparatuses: a homemade water manometer (− 2.94 to 0 mmH 2 O) and a pneumatic high-speed pressure clamp (− 25 to 0 mmHg). To visualize Ca 2+ influx, RBCs were pre-loaded with an intensiometric probe Cal-520 AM, then imaged under a confocal microscope with concurrent bright-field and fluorescent imaging at acquisition rates of 10 frames per second. Remarkably, we observed the related changes in intracellular Ca 2+ levels immediately after aspirating individual RBCs in a pressure-dependent manner. The RBC aspirated by the water manometer only displayed 1.1-fold increase in fluorescence intensity, whereas the RBC aspirated by the pneumatic clamp showed up to threefold increase. These results demonstrated the water manometer as a gentle tool for cell manipulation with minimal pre-activation, while the high-speed pneumatic clamp as a much stronger pressure actuator to examine cell mechanosensing directly. Together, this multimodal platform enables us to precisely control aspiration and membrane tension, and subsequently correlate this with intracellular calcium concentration dynamics in a robust and reproducible manner.

Wang, Haoqing↗

Indirect percutaneous core needle biopsy of solid pancreatic or peripancreatic lesions

Solid pancreatic or peripancreatic lesions comprise a heterogeneous group of diseases that rely on a multimodality imaging approach for subsequent tissue procurement. Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA)/biopsy is an effective and safe method for tissue diagnosis in this region. The failure to obtain adequate tissue for diagnosis under EUS guidance is still a rare but important issue. Percutaneous core needle biopsy (CNB) provides an alternative pathway for adequate specimen acquisition. Because of the deep retroperitoneal location, the percutaneous biopsy of pancreatic or peripancreatic lesions may inevitably pass through visceral organs. The procedure is relatively risky and difficult for general radiologists, particularly beginners, and an adequate knowledge of the abdominal anatomy and biopsy technique is indispensable. In this review, various aspects of percutaneous CNB for solid pancreatic or peripancreatic lesions using different trans-organ approaches are reviewed to increase the chance of successful biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radioembolization of the Spleen: A Revisited Approach for the Treatment of Malignant Lymphomatous Splenomegaly

Intraarterial administration of {sup 90}Y microspheres to the spleen in patients with malignant lymphoma was mentioned once in the literature in 1973. This case study illustrates the potential indication of selective internal radiotherapy in a heavily pretreated patient with highly refractory disease with a marginal zone lymphoma in leukemic phase and symptomatic splenomegaly. We describe the clinical course of disease; the biological and clinical response to the treatment after radioembolization; and simulation and dosimetry by multimodal imaging via single-photon emission computed tomography and computed tomography. The advantages of radioembolization for the management of lymphomatous splenomegaly are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Role for Adjuvant RFA in Managing Hepatic Metastases from Gastrointestinal Stromal Tumors (GIST) After Treatment with Targeted Systemic Therapy Using Kinase Inhibitors

Purpose: This study was designed to assess the role of radiofrequency ablation (RFA) in the multimodality management of gastrointestinal stromal tumors (GIST) in patients undergoing targeted tyrosine kinase inhibitor therapy (TKI) for liver metastases. Methods: Outcomes of 17 patients who underwent liver RFA for 27 metastatic GIST after TKI therapy, from January 2004 to March 2012, were retrospectively analyzed. Mean maximum tumor diameter was 2.5 ± 1 cm (range 0.9–4.5 cm). In seven patients (group A), RFA of all residual tumors was performed, with curative intent, and TKI therapy was discontinued. In five patients (group B), RFA of all residual tumors was performed upon achieving the best morphological response with TKI therapy, which was maintained after RFA. In another five patients (group C), RFA was performed on individual liver metastases which were progressive under TKI therapy. Results: All 27 targeted tumors were completely ablated, without local recurrence during the mean follow-up period of 49 months. No major complications occurred. Two minor complications were reported (11 %). Only two patients (both in group C) died at 20 and 48 months. Two-year progression-free survival (PFS) after RFA was 29 % in group A, 75 % in group B, and 20 % in group C. Conclusions: RFA in patients, previously treated with TKI, is feasible and safe. Our data suggest that RFA is a useful therapeutic option in patients with metastatic GIST and should be performed at the time of best clinical response with patient maintained under TKI after the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

18F-FDOPA PET/CT-Guided Radiofrequency Ablation of Liver Metastases from Neuroendocrine Tumours: Technical Note on a Preliminary Experience

AimTo review our preliminary experience with 6-l-18F-fluorodihydroxyphenylalanine (18F-FDOPA) PET/CT-guided radiofrequency ablation (RFA) of liver metastases from neuroendocrine tumours (NETs).Materials and MethodsThree patients (mean age 51.3 years; range 43–56) with gastro-entero pancreatic NET (GEP-NET) liver metastases underwent 18F-FDOPA PET/CT-guided RFA. Patients were referred with oligometastatic hepatic-confined disease (1–6 metastases; <3 cm) on 18F-FDOPA PET/CT; poor lesion visualisation on US, CT, and MR; and ongoing symptoms. Procedures were performed in an interventional PET/CT scanner under general anaesthesia using a split-dose protocol. Lesion characteristics, procedural duration and technical success (accurate probe placement and post-procedural ablation-zone photopaenia), complications, patient and operator dose, and clinical outcomes were evaluated.ResultsThirteen liver metastases (mean size 11.4 mm, range 8–16) were treated in three patients (two presented with “carcinoid syndrome”). Technical success was 100 % with a mean procedural duration of 173.3 min (range 90–210) and no immediate complications. Mean patient dose was 2844 mGy·cm (range 2104–3686). Operator and radiographer doses were acceptable other than the operator’s right hand in the first case (149 µSv); this normalised in the second case. There was no local tumour or extra-hepatic disease progression at mid-term follow-up (mean 12.6 months; range 6–20); however, two cases progressed with new liver metastases at different sites. There was 100 % clinical success (n = 2) in resolving carcinoid syndrome symptoms.Conclusion18F-FDOPA PET/CT-guided RFA appears technically feasible, safe, and effective in patients with GEP-NETs and low-burden hepatic metastases. Further prospective studies are required to elucidate its precise role in tailored multimodality management of GEP-NET liver metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intravascular Papillary Endothelial Hyperplasia (Masson’s Tumor) of the Radial Artery: A Case Report

Intravascular papillary endothelial hyperplasia (IPEH), often referred to as Masson’s tumor, is a benign non-neoplastic vascular lesion of the skin and subcutaneous tissues. Although it is rare, knowledge of the existence of IPEH is important as it can mimic other benign and malignant tumors, most notably angiosarcoma. IPEH remains an incompletely understood entity; however, most consider it to be the result of reactive endothelial proliferation following thrombus formation within a vessel, vascular malformation, or adjacent to a vessel. In this article, we report a case of IPEH arising within an arteriovenous malformation of the radial artery and present accompanying multimodality imaging and pathology figures. We will also describe the clinical presentation, pathophysiology, histology, imaging features, and management of IPEH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low Cerebral Blood Volume Identifies Poor Outcome in Stent Retriever Thrombectomy

BackgroundMechanical thrombectomy (MT) is an efficient treatment of acute stroke caused by large-vessel occlusion. We evaluated the factors predicting poor clinical outcome (3-month modified Rankin Scale, mRS >2) although MT performed with modern stent retrievers.MethodsWe prospectively collected the clinical and imaging data of 105 consecutive anterior circulation stroke patients who underwent MT after multimodal CT imaging. Patients with occlusion of the internal carotid artery and/or middle cerebral artery up to the M2 segment were included. We recorded baseline clinical, procedural and imaging variables, technical outcome, 24-h imaging outcome and the clinical outcome. Differences between the groups were studied with appropriate statistical tests and binary logistic regression analysis.ResultsLow cerebral blood volume Alberta stroke program early CT score (CBV-ASPECTS) was associated with poor clinical outcome (median 7 vs. 9, p = 0.01). Lower collateral score (CS) significantly predicted poor outcome in regression modelling with CS = 0 increasing the odds of poor outcome 4.4-fold compared to CS = 3 (95% CI 1.27–15.5, p = 0.02). Lower CBV-ASPECTS significantly predicted poor clinical outcome among those with moderate or severe stroke (OR 0.82, 95% CI 0.68–1, p = 0.05) or poor collateral circulation (CS 0–1, OR 0.66, 95% CI 0.48–0.90, p = 0.009) but not among those with mild strokes or good collaterals.ConclusionsCBV-ASPECTS estimating infarct core is a significant predictor of poor clinical outcome among anterior circulation stroke patients treated with MT, especially in the setting of poor collateral circulation and/or moderate or severe stroke.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Basic Knowledge in Soft Tissue Sarcoma

Sarcoma is rare and heterogenous with various subtypes having a different prognostic. Desmoid is a tumour with a local aggressiveness; GIST with KIT mutation responds massively to target treatment as IMATINIB, whereas soft tissue sarcoma and leiomyosarcoma are very aggressive with poor response to systemic therapies. Interventional radiology plays an important role in the diagnosis of sarcomas with image-guided percutaneous core needle biopsy being the most commonly used biopsy technique in the diagnosis of sarcomas. Biopsy access routes discussed with the surgeon, and skin access is tattooed. Surgery is a mainstay of sarcoma treatment; the resection can be large. Indeed, resection objective is R0 because quality of surgical margins impacts local control and survival. Radiotherapy is possible in neoadjuvant or in adjuvant treatment to improve local control rate. Recently radiotherapy enhancer injected percutaneously in soft tissue sarcoma has proven benefit in increasing the rate of R0 complete surgical resection. Several studies showed better local control rate linked with post-operative radiotherapy. In patients affected by oligometastatic disease, complete surgical resection of all metastatic sites is in fact considered the primary treatment because complete remission is critical for cure. The decision making to use local therapies is complex, depends upon diverse presentations and histologies, and should always be taken in a multidisciplinary discussion. Today, percutaneous image-guided treatments with ablation technologies (radiofrequency ablation, cryotherapy, microwaves ablation) provide high rate of durable local control for small-sized malignant deposit in many organs including lung, liver and bones. Sarcoma must be managed by multimodality treatment in expert reference centres. Such management has a considerable impact on the prognosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indian summer monsoon variability forecasts in the North American multimodel ensemble

The representation of the seasonal mean and interannual variability of the Indian summer monsoon rainfall (ISMR) in nine global ocean-atmosphere coupled models that participated in the North American Multimodal Ensemble (NMME) phase 1 (NMME:1), and in nine global ocean-atmosphere coupled models participating in the NMME phase 2 (NMME:2) from 1982–2009, is evaluated over the Indo-Pacific domain with May initial conditions. The multi-model ensemble (MME) represents the Indian monsoon rainfall with modest skill and systematic biases. There is no significant improvement in the seasonal forecast skill or interannual variability of ISMR in NMME:2 as compared to NMME:1. The NMME skillfully predicts seasonal mean sea surface temperature (SST) and some of the teleconnections with seasonal mean rainfall. However, the SST-rainfall teleconnections are stronger in the NMME than observed. The NMME is not able to capture the extremes of seasonal mean rainfall and the simulated Indian Ocean-monsoon teleconnections are opposite to what are observed.

54 ENVIRONMENTAL SCIENCES↗

Minerals limit the deep soil respiration response to warming in a tropical Andisol

Tropical regions hold one third of the world’s soil organic carbon, but few experiments have warmed tropical soils in situ. The vulnerability of these soils to climate change-induced losses is uncertain with many hypothesizing these soils would be less sensitive to climate change because already-high temperatures in tropical systems might limit microbial sensitivity or due to increased mineral protection of organic carbon in highly weathered tropical soils. Here we present the results of a deep soil (0–100 cm) warming experiment in a tropical Andisol. Andisols can store large, persistent pools of soil carbon that are protected from decomposition by poorly and non-crystalline minerals (PNCM). In 20 cm depth intervals, we measured key soil properties including carbon, nitrogen, pH, PNCM, bacterial and fungal richness along with temperature, moisture, and CO 2 production. Over a year of soil warming, CO 2 production significantly increased by 50–300% per degree of warming, but only in the top 40 cm of the soil profile in contrast to the results of other deep soil warming experiments. Multimodal analysis supported our hypothesis that high concentrations of PNCM was the primary driver of the lack of CO 2 response, followed by high relative soil moisture and low bacterial richness, which may be a proxy for organic carbon availability. The lack of elevated CO 2 production in response to warming suggests a limited positive feedback to climate change in Andisols driven by their strong mineral protection of organic matter. Therefore, Andisols should be considered high priority restoration or protection areas when considering the management of soil carbon stocks as part of climate action.

54 ENVIRONMENTAL SCIENCES↗

Convergence analysis for a nonlocal gradient descent method via directional Gaussian smoothing

We analyze the convergence of a nonlocal gradient descent method for minimizing a class of high-dimensional non-convex functions, where a directional Gaussian smoothing (DGS) is proposed to define the nonlocal gradient (also referred to as the DGS gradient). The method was first proposed in [Zhang et al., Enabling long-range exploration in minimization of multimodal functions, UAI 2021], in which multiple numerical experiments showed that replacing the traditional local gradient with the DGS gradient can help the optimizers escape local minima more easily and significantly improve their performance. However, a rigorous theory for the efficiency of the method on nonconvex landscape is lacking. In this work, we investigate the scenario where the objective function is composed of a convex function, perturbed by deterministic oscillating noise. We provide a convergence theory under which the iterates exponentially converge to a tightened neighborhood of the solution, whose size is characterized by the noise wavelength. Here, we also establish a correlation between the optimal values of the Gaussian smoothing radius and the noise wavelength, thus justifying the advantage of using moderate or large smoothing radii with the method. Furthermore, if the noise level decays to zero when approaching the global minimum, we prove that DGS-based optimization converges to the exact global minimum with linear rates, similarly to standard gradient-based methods in optimizing convex functions. Several numerical experiments are provided to confirm our theory and illustrate the superiority of the approach over those based on the local gradient.

Tran, Hoang [Oak Ridge National Laboratory (ORNL),↗

Eye-Safe KGd(WO{sub 4}){sub 2} Raman Lasers: Comparative Study of Pumping of Nd:KGd(WO{sub 4}){sub 2} Lasers With {sup 4}F{sub 3/2} → {sup 4}I{sub 11/2} and {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} Working Transitions{sup **}

This is a comparative study of eye-safe extracavity KGd(WO{sub 4}){sub 2} (KGW) Raman lasers that convert multimode emission from pulsed Nd:KGW lasers operating on the {sup 4}F{sub 3/2} → {sup 4}I{sub 11/2} and {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} transitions into the third Stokes component at λ = 1500 nm and the first Stokes component at λ = 1507 or 1538 nm. For equal sizes of the Raman and laser sections of a Raman laser emitting the third Stokes component, the pulse energy is higher (~14.2 mJ) and the divergence of the Stokes beam is lower (~9.4 mrad) for a lower energy of the Nd:KGW laser (~6.7 J). For pump pulse energies of 29–34 mJ, all the Raman lasers have essentially the same optical lasing efficiency of up to 36%. In terms of the electrical energy delivered to the flashlamp, however, the overall efficiency of the Raman laser for the third Stokes component is a factor of ~1.7 higher. The duration of the Raman pulses is comparable to that of the pump pulses and is ~20 ns for the first Stokes components. The pulse in the third Stokes component is shorter by a factor of 2.5–3. Given the different pump levels and the differences in the thermallyinduced optical distortions of the Nd:KGW laser components, the energy density distribution for beams of the first Stokes components is elliptical, while that of the third Stokes components is almost circular. The possibility of simultaneous lasing at wavelengths of 1507 and 1538 nm with parallel and mutually orthogonal polarizations of the Stokes waves is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Possibility of an integrated transmission electron microscope: enabling complex in-situ experiments

Abstract Multimodal in-situ experiments are the wave of the future, as this approach will permit multispectral data collection and analysis during real-time nanoscale observation. In contrast, the evolution of technique development in the electron microscopy field has generally trended toward specialization and subsequent bifurcation into more and more niche instruments, creating a challenge for reintegration and backward compatibility for in-situ experiments on state-of-the-art microscopes. We do not believe this to be a requirement in the field; therefore, we propose an adaptive instrument that is designed to allow nearly simultaneous collection of data from aberration-corrected transmission electron microscopy (TEM), probe-corrected scanning transmission electron microscopy, ultrafast TEM, and dynamic TEM with a flexible in-situ testing chamber, where the entire instrument can be modified as future technologies are developed. The value would be to obtain a holistic understanding of the underlying physics and chemistry of the process-structure–property relationships in materials exposed to controlled extreme environments. Such a tool would permit the ability to explore, in-situ, the active reaction mechanisms in a controlled manner emulating those of real-world applications with nanometer and nanosecond resolution. If such a powerful tool is developed, it has the potential to revolutionize our materials understanding of nanoscale mechanisms and transients. Graphical Abstract

36 MATERIALS SCIENCE↗

Convergence and Efficiency of Adaptive Importance Sampling Techniques with Partial Biasing

We propose a new Monte Carlo method to efficiently sample a multimodal distribution (known up to a normalization constant). We consider a generalization of the discrete-time Self Healing Umbrella Sampling method, which can also be seen as a generalization of well-tempered metadynamics. The dynamics is based on an adaptive importance technique. The importance function relies on the weights (namely the relative probabilities) of disjoint sets which form a partition of the space. These weights are unknown but are learnt on the fly yielding an adaptive algorithm. In the context of computational statistical physics, the logarithm of these weights is, up to an additive constant, the free-energy, and the discrete valued function defining the partition is called the collective variable. The algorithm falls into the general class of Wang–Landau type methods, and is a generalization of the original Self Healing Umbrella Sampling method in two ways: (i) the updating strategy leads to a larger penalization strength of already visited sets in order to escape more quickly from metastable states, and (ii) the target distribution is biased using only a fraction of the free-energy, in order to increase the effective sample size and reduce the variance of importance sampling estimators. We prove the convergence of the algorithm and analyze numerically its efficiency on a toy example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗