Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

ADVANTG An Automated Variance Reduction Parameter Generator

The AutomateD VAriaNce reducTion Generator (ADVANTG) software automates the generation of variance reduction (VR) parameters for continuous-energy Monte Carlo simulations of fixed-source neutron, photon, and coupled neutron-photon transport problems using MCNP5 (X-5 Monte Carlo Team 2003). ADVANTG generates space- and energy dependent mesh-based weight-window bounds and biased source distributions from three dimensional (3-D) discrete ordinates (SN) calculations that are performed by the Denovo package (Evans et al. 2010). The deterministic calculations can be performed using multiple cores and/or processors (e.g., on multi-core desktop systems and clusters). The final variance reduction parameters are output in a format that can be used with unmodified versions of MCNP. The primary objective of the development of ADVANTG has been to reduce both the user effort and the computational time required to obtain accurate and precise tally estimates across a broad range of challenging transport application areas.

ADVANTG↗

Uncertainties in Air Exchange using Continuous-Injection, Long-Term Sampling Tracer-Gas Methods

The PerFluorocarbon Tracer (PFT) method is a low-cost approach commonly used for measuring air exchange in buildings using tracer gases. It is a specific application of the more general Continuous-Injection, Long-Term Sampling (CILTS) method. The technique is widely used but there has been little work on understanding the uncertainties (both precision and bias) associated with its use, particularly given that it is typically deployed by untrained or lightly trained people to minimize experimental costs. In this article we will conduct a first-principles error analysis to estimate the uncertainties and then compare that analysis to CILTS measurements that were over-sampled, through the use of multiple tracers and emitter and sampler distribution patterns, in three houses. We find that the CILTS method can have an overall uncertainty of 10-15percent in ideal circumstances, but that even in highly controlled field experiments done by trained experimenters expected uncertainties are about 20percent. In addition, there are many field conditions (such as open windows) where CILTS is not likely to provide any quantitative data. Even avoiding the worst situations of assumption violations CILTS should be considered as having a something like a ?factor of two? uncertainty for the broad field trials that it is typically used in. We provide guidance on how to deploy CILTS and design the experiment to minimize uncertainties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chromatic effects on the PSF and shear measurement for the Roman Space Telescope High-Latitude Wide Area Survey

Weak gravitational lensing (WL) is a key cosmological probe that requires precise measurement of galaxy images to infer shape distortions, or shear, and constrain cosmology. Accurate estimation of the point spread function (PSF) is crucial for shear measurement, but the wavelength dependence of the PSF introduces chromatic biases that can systematically impact shear inference. We focus on biases arising from spectral energy distribution (SED) differences between stars, used for PSF modelling, and galaxies, used for shear measurement. We investigate these effects in Roman’s four design reference mission WL bands (Y106, J129, H158, F184) and wide filter (W146). Using Roman-like image simulations, we quantify the induced shear biases and compare them to requirements on those biases. Multiplicative biases over all galaxies hover around ~0.2 per cent in the WL bands and 2 per cent in the wide filter, exceeding the mission requirement of |m| < 0.032 per cent and relaxed requirement of |m| < 0.1 per cent⁠. In individual redshift bins, biases can reach 0.4–0.9 per cent for the WL bands and 3–6 per cent for the wide filter. Additive biases remain acceptable in the WL bands but exceed systematic limits in the wide filter. We develop and test PSF-level corrections, showing that a first-order correction reduces biases within survey requirements for the WL bands; however, higher-order terms are necessary for the wide filter. Our results highlight the necessity of chromatic corrections for precision WL with Roman and provide a framework for mitigating these biases. Finally, we compare analytical colour-based corrections to self-organizing maps and find that both methods effectively reduce biases.

79 ASTRONOMY AND ASTROPHYSICS↗

OF 'COCKTAIL PARTIES' AND EXOPLANETS

The characterization of ever smaller and fainter extrasolar planets requires an intricate understanding of one's data and the analysis techniques used. Correcting the raw data at the 10{sup -4} level of accuracy in flux is one of the central challenges. This can be difficult for instruments that do not feature a calibration plan for such high precision measurements. Here, it is not always obvious how to de-correlate the data using auxiliary information of the instrument and it becomes paramount to know how well one can disentangle instrument systematics from one's data, given nothing but the data themselves. We propose a non-parametric machine learning algorithm, based on the concept of independent component analysis, to de-convolve the systematic noise and all non-Gaussian signals from the desired astrophysical signal. Such a 'blind' signal de-mixing is commonly known as the 'Cocktail Party problem' in signal processing. Given multiple simultaneous observations of the same exoplanetary eclipse, as in the case of spectrophotometry, we show that we can often disentangle systematic noise from the original light-curve signal without the use of any complementary information of the instrument. In this paper, we explore these signal extraction techniques using simulated data and two data sets observed with the Hubble Space Telescope NICMOS instrument. Another important application is the de-correlation of the exoplanetary signal from time-correlated stellar variability. Using data obtained by the Kepler mission we show that the desired signal can be de-convolved from the stellar noise using a single time series spanning several eclipse events. Such non-parametric techniques can provide important confirmations of the existent parametric corrections reported in the literature, and their associated results. Additionally they can substantially improve the precision exoplanetary light-curve analysis in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Comprehensive Assessments of RNA-seq by the SEQC Consortium: FDA-Led Efforts Advance Precision Medicine

Studies on gene expression in response to therapy have led to the discovery of pharmacogenomics biomarkers and advances in precision medicine. Whole transcriptome sequencing (RNA-seq) is an emerging tool for profiling gene expression and has received wide adoption in the biomedical research community. However, its value in regulatory decision making requires rigorous assessment and consensus between various stakeholders, including the research community, regulatory agencies, and industry. The FDA-led SEquencing Quality Control (SEQC) consortium has made considerable progress in this direction, and is the subject of this review. Specifically, three RNA-seq platforms (Illumina HiSeq, Life Technologies SOLiD, and Roche 454) were extensively evaluated at multiple sites to assess cross-site and cross-platform reproducibility. The results demonstrated that relative gene expression measurements were consistently comparable across labs and platforms, but not so for the measurement of absolute expression levels. As part of the quality evaluation several studies were included to evaluate the utility of RNA-seq in clinical settings and safety assessment. The neuroblastoma study profiled tumor samples from 498 pediatric neuroblastoma patients by both microarray and RNA-seq. RNA-seq offers more utilities than microarray in determining the transcriptomic characteristics of cancer. However, RNA-seq and microarray-based models were comparable in clinical endpoint prediction, even when including additional features unique to RNA-seq beyond gene expression. The toxicogenomics study compared microarray and RNA-seq profiles of the liver samples from rats exposed to 27 different chemicals representing multiple toxicity modes of action. Cross-platform concordance was dependent on chemical treatment and transcript abundance. Though both RNA-seq and microarray are suitable for developing gene expression based predictive models with comparable prediction performance, RNA-seq offers advantages over microarray in profiling genes with low expression. The rat BodyMap study provided a comprehensive rat transcriptomic body map by performing RNA-Seq on 320 samples from 11 organs in either sex of juvenile, adolescent, adult and aged Fischer 344 rats. Lastly, the transferability study demonstrated that signature genes of predictive models are reciprocally transferable between microarray and RNA-seq data for model development using a comprehensive approach with two large clinical data sets. This result suggests continued usefulness of legacy microarray data in the coming RNA-seq era. In conclusion, the SEQC project enhances our understanding of RNA-seq and provides valuable guidelines for RNA-seq based clinical application and safety evaluation to advance precision medicine.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative estimation in Health Impact Assessment: Opportunities and challenges

Health Impact Assessment (HIA) considers multiple effects on health of policies, programs, plans and projects and thus requires the use of diverse analytic tools and sources of evidence. Quantitative estimation has desirable properties for the purpose of HIA but adequate tools for quantification exist currently for a limited number of health impacts and decision settings; furthermore, quantitative estimation generates thorny questions about the precision of estimates and the validity of methodological assumptions. In the United States, HIA has only recently emerged as an independent practice apart from integrated EIA, and this article aims to synthesize the experience with quantitative health effects estimation within that practice. We use examples identified through a scan of available identified instances of quantitative estimation in the U.S. practice experience to illustrate methods applied in different policy settings along with their strengths and limitations. We then discuss opportunity areas and practical considerations for the use of quantitative estimation in HIA.

54 ENVIRONMENTAL SCIENCES↗

A call to standardize metrics for monitoring baleen whales near marine construction activities

Effective monitoring is necessary to protect marine mammal species during the construction of offshore infrastructure. The tools for detecting or monitoring marine mammals span traditional (e.g., visual observers, optical cameras), to newer (e.g., passive acoustic monitoring, infrared cameras, tags), and emerging (e.g., satellite imagery, environmental DNA, dimethyl sulfide concentration) technologies. Some are better suited for use during offshore development; however, peer-reviewed literature does not typically evaluate and report on the performance of these various technologies. We define a minimum set of metrics related to efficacy (i.e., confusion matrix, precision and recall, probability of missed mitigation), detection range (i.e., maximum and reliable detection range, spatial resolution), and data delivery (i.e., detection latency, system reliability, temporal resolution) that we recommend are needed to assess the utility of monitoring technologies for this purpose. Following a literature review of relevant studies, we highlight which publications reported these metrics and used multiple technologies to compare relative performance. We also emphasize the benefits of multi-modal approaches and recommend performance assessments through modeling or large-scale collaborative field testing. These metrics will standardize data collection, reporting, and analysis; promote consistent and comparable results; and foster collaboration among developers, regulatory agencies, and scientists. This may lead to the co-development of technology that achieves multiple goals, has greater application, and can answer research questions while collecting data to fulfill permitting requirements. These metrics may also inform decisions on what systems regulatory agencies might consider using and reduce monitoring costs, which is critical to support the marine sector's rapid growth alongside marine mammal conservation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Resolution Comonomer Sequencing of Blocky Brominated Syndiotactic Polystyrene Copolymers Using 13C NMR Spectroscopy and Computer Simulations

This work demonstrates the first high-resolution comonomer sequencing of Blocky brominated syndiotactic polystyrene (sPS-co-sPS-Br) copolymers based on pentad assign- ments of the quaternary carbon region of the nuclear magnetic resonance spectrum. Copolymers containing p-bromostyrene (Br-Sty) units were prepared in matched sets using postpolymerization bromination methods carried out in the heterogeneous gel state (Blocky) and homogeneous solution state (Random). Quantitative information from the quaternary carbon spectra, heteronuclear multiple bond correlation spectroscopy, electronic structure calculations, and simulated statistically random copolymers was correlated to confirm the carbon resonance assignments for all 20 possible pentad comonomer sequences. Using the experimental pentad sequence prevalences, a computer code was developed to simulate chains with microstructures typical of each sample as a means to visually represent the copolymer blockiness with quantitative precision. Based on the microstructure and distribution of run lengths in these chains, the simulations revealed that the Blocky copolymers contain a high degree of blockiness. By comparing the run lengths in the simulated chains to the average number of styrene units in a crystalline segment of sPS (found by small-angle X-ray scattering), copolymer crystallizability was predicted. For the simulated Blocky B-21% (21 mol % Br-Sty) chain, the probability of randomly selecting a styrene unit in a crystallizable block was 25.8%, while that in the simulated Random R-18% was zero, in excellent agreement with the experimental crystallization behavior measured by differential scanning calorimetry. Additionally, these predictions confirmed that the simulated chains accurately represent the ensemble of chains in their respective copolymer samples. Furthermore, each simulated Blocky chain contained one or more long sPS blocks that paralleled the measured 38-40 styrene units spanning a crystalline segment within the sPS/CCl4 gel. This finding affirmed that the long sPS segments originated from the precise lamellar structure within the heterogeneous gel morphology (i.e., block length is correlated with lamellar thickness). Overall, the ability to tailor the copolymer microstructure through control of the semicrystalline gel morphology opens the door to synthesizing ordered copolymers by postpolymerization functionalization processes with unprecedented levels of compositional control.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CONSTRAINING THE STRUCTURE OF SAGITTARIUS A*'s ACCRETION FLOW WITH MILLIMETER VERY LONG BASELINE INTERFEROMETRY CLOSURE PHASES

Millimeter wave very long baseline interferometry (mm-VLBI) provides access to the emission region surrounding Sagittarius A* (Sgr A*), the supermassive black hole at the center of the Milky Way, on sub-horizon scales. Recently, a closure phase of 0{sup 0} {+-} 40{sup 0} was reported on a triangle of Earth-sized baselines (SMT-CARMA-JCMT) representing a new constraint upon the structure and orientation of the emission region, independent from those provided by the previously measured 1.3 mm-VLBI visibility amplitudes alone. Here, we compare this to the closure phases associated with a class of physically motivated, radiatively inefficient accretion flow models and present predictions for future mm-VLBI experiments with the developing Event Horizon Telescope (EHT). We find that the accretion flow models are capable of producing a wide variety of closure phases on the SMT-CARMA-JCMT triangle and thus not all models are consistent with the recent observations. However, those models that reproduce the 1.3 mm-VLBI visibility amplitudes overwhelmingly have SMT-CARMA-JCMT closure phases between {+-}30{sup 0}, and are therefore broadly consistent with all current mm-VLBI observations. Improving station sensitivity by factors of a few, achievable by increases in bandwidth and phasing together multiple antennas at individual sites, should result in physically relevant additional constraints upon the model parameters and eliminate the current 180{sup 0} ambiguity on the source orientation. When additional stations are included, closure phases of order 45{sup 0}-90{sup 0} are typical. In all cases, the EHT will be able to measure these with sufficient precision to produce dramatic improvements in the constraints upon the spin of Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

The Reconstruction Software for the Muon Ionization Cooling Experiment Trackers

The international Muon Ionisation Cooling Experiment (MICE) is designed to demonstrate the principle of muon ionization cooling, for application to a future Neutrino Factory or Muon Collider. In order to measure the change in emittance, MICE is equipped with a pair of high precision scintillating fibre trackers. The trackers are required to measure a 10% change in emittance to 1% accuracy (giving an overall precision of 0.1%). This paper describes the tracker reconstruction software, as a part of the overall MICE software framework, MAUS. Channel clustering is described, proceeding to the formation of space-points, which are then associated with particle tracks using pattern recognition algorithms. Finally a full custom Kalman track fit is performed, to account for energy loss and multiple scattering. Exemplar results are shown for Monte Carlo data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraining the top-Higgs sector of the standard model effective field theory

Working in the framework of the Standard Model effective field theory, we study chirality-flipping couplings of the top quark to Higgs and gauge bosons. In this paper, we discuss in detail the renormalization-group evolution to lower energies and investigate direct and indirect contributions to high- and low-energy $CP$-conserving and $CP$-violating observables. Our analysis includes constraints from collider observables, precision electroweak tests, flavor physics, and electric dipole moments. We find that indirect probes are competitive or dominant for both $CP$-even and $CP$-odd observables, even after accounting for uncertainties associated with hadronic and nuclear matrix elements, illustrating the importance of including operator mixing in constraining the Standard Model effective field theory. We also study scenarios where multiple anomalous top couplings are generated at the high scale, showing that while the bounds on individual couplings relax, strong correlations among couplings survive. In conclusion, we find that enforcing minimal flavor violation does not significantly affect the bounds on the top couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Including Chi-Nu 235 U PFNS Experimental Data into an ENDF/B-VIII.1 Release Candidate Evaluation

This report documents an evaluation of 235 U prompt fission neutron spectra (PFNS) that is a release candidate for the upcoming U.S. nuclear data library, ENDF/B-VIII.1. This evaluation differs from its predecessor, ENDF/B-VIII.0, mainly by the inclusion of 235 U PFNS measured by the Chi-Nu team of LANL and LLNL. This data set is the first one that covers the 235 U PFNS for continuous incident-neutron energies of 1⁻20 MeV and outgoing-neutron energies from 10 keV⁻10 MeV with high precision. Previous data sets were either measured in a limited energy range or with less precision. Hence, these new Chi-Nu data provide decisive information for the evaluation. The resulting evaluated data correspond well to the new experimental PFNS. The evaluated PFNS also produce average mean energies and 239 Pu/ 235 U PFNS in agreement with associated Chi-Nu data. If one uses the new evaluated data to predict the neutron multiplication factor, k eff , of selected ICSBEP critical assemblies, the differences of simulated values compared to those using ENDF/B-VIII.0 is modest (less than 55 pcm). This difference in k eff can be easily accommodated by changes in the 235 U average prompt fission neutron multiplicity that is currently being re-evaluated. In addition to that, the new PFNS predict on average 235 U LLNL pulsed-sphere neutron-leakage spectra better than ENDF/B-VIIII.0 PFNS.

235U↗

Demonstration of Multi-Gamma Based Sensor Technology for As-Fired Coal Property Measurement

This project demonstrated the application of the use of an advanced multigamma attenuation (MGA) sensor to accurately and precisely measure coal properties at the point of injection into burners. Accurate and precise coal property information at the burner provides the opportunity to adjust burner parameters to better follow changing load condition, optimize flame stability, and decrease nitrogen oxide formation at each burner. In addition, coal property information at the burner will assist in managing slag flow behavior, fireside ash related deposition, corrosion, and erosion issues. The advantage of having multiple gamma emitters is that the atomic/elemental interaction with the gamma energy takes place at several energies and the resulting attenuation is dependent upon the atomic number of the atom/element encountered in the coal.

01 COAL, LIGNITE, AND PEAT↗

Commentary: Duckweeds as model organisms for metabolic studies

Duckweeds have many practical applications, for example in human nutrition, as animal feed, in the production of bioplastics or vaccines, and phytoremediation (Acosta et al., 2021). Under most conditions, they reproduce asexually which provides genetically uniform material with predictable patterns of growth that make them ideal as sentinel organisms for phytotoxicity testing (Park et al., 2021). Asexual growth also results in high biomass production which makes duckweeds promising candidates as biofuel feedstocks (Acosta et al., 2021; Liang et al., 2023). In addition, duckweed species like Lemna minor and Spirodela polyrhiza are also reemerging as model organisms in plant biology as high-quality full genome assemblies and other genomic resources become available (Chang et al., 2016; Acosta et al., 2021). We argue that duckweed species are particularly of interest for the study of primary plant metabolism. Primary metabolism concerns the part of metabolism that is directly involved in the growth and development of plants, and which tends to be highly conserved among plant species. What makes duckweeds particularly attractive is that when grown on liquid media more precise control of physiological conditions can be attained relative to growth of plants in soil. Also, due to their relatively simple anatomical structure and asexual reproduction of fronds by budding, precise characterization of the physiological state under study is possible through one simple metric, i.e., the specific growth rate (rate of dry weight increase per existing dry weight), which can be incorporated relatively easily into metabolic models. This is not possible for land plants, such as Arabidopsis, because over the course of their life cycle, they go through multiple growth stages and phases of anatomical differentiation, which are much more complex to quantify. Furthermore, duckweeds can grow on organic substrates under heterotrophic or photomixotrophic conditions that facilitate isotope tracer studies. For example, in a previous study on duckweed by one of the authors, Lemna gibba (L). was grown on glucose with a position-specific 13 C-label that can be detected and resolved by Mass Spectrometry or Nuclear Magnetic Resonance spectrometry. Using this approach, the 13 C-label was traced into biomass compounds formed from glucose, particularly isoprenoid compounds. Some of the resulting labeling patterns were in apparent disagreement with predictions based on known metabolic pathways for the biosynthesis of isopentenyl pyrophosphate, the universal building block for isoprenoids, (Lichtenthaler et al., 1997). From this data it was deduced that isoprenoid compounds such as carotenoids and isoprenoid chains of phytol and plastoquinone, synthesized in the chloroplast, are produced via a previously unreported plant metabolic pathway, now known as the methylerythitol/deoxyxylulose-5-phosphate pathway (Lichtenthaler et al., 1997).

59 BASIC BIOLOGICAL SCIENCES↗

A First Search for Argon-Bound Neutron-Antineutron Oscillation using the MicroBooNE LArTPC

The use of Liquid Argon Time Projection Chambers (LArTPCs) as a detector technology in neutrino experiments has grown considerably over the past two decades. The excellent spatial and calorimetric resolution offered by LArTPCs enable precise neutrino oscillation measurements as well as beyond-Standard Model searches. One such search, which is the focus of this note, is the search for nucleus-bound neutron-antineutron (n ₋ n̄) oscillation. The n ₋ n̄ oscillation process is a baryon number violating process that produces a unique, star-like topology as a result of multiple final state pions. This unique signature is a key feature that may be used to search for this signal process. This note describes a machine learning-based analysis of MicroBooNE data, making use of a sparse convolutional neural network to search for n ₋ n̄ oscillation-like signals in MicroBooNE. While the future DUNE LArTPC can search for this signature with high sensitivity, existing MicroBooNE data can be used to demonstrate and validate methodologies that can be used as part of the DUNE search. This document presents the first-ever search for n ₋ n̄ oscillation in a LArTPC, using MicroBooNE off-beam data (data collected when the neutrino beam was not running).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A first search for argon-bound neutron-antineutron oscillation using the MicroBooNE LArTPC

The use of Liquid Argon Time Projection Chambers (LArTPCs) as a detector technology in neutrino experiments has grown considerably over the past two decades. The excellent spatial and calorimetric resolution offered by LArTPCs enable precise neutrino oscillation measurements as well as beyond-Standard Model searches. One such search, which is the focus of this note, is the search for nucleus-bound neutron-antineutron (n – n̄) oscillation. The n – n̄ oscillation process is a baryon number violating process that produces a unique, star-like topology as a result of multiple final state pions. This unique signature is a key feature that may be used to search for this signal process. This note describes a machine learning-based analysis of MicroBooNE data, making use of a sparse convolutional neural network to search for n – n̄ oscillation-like signals in MicroBooNE. While the future DUNE LArTPC can search for this signature with high sensitivity, existing MicroBooNE data can be used to demonstrate and validate methodologies that can be used as part of the DUNE search. This document presents the first-ever search for n – n̄ oscillation in a LArTPC, using MicroBooNE off-beam data (data collected when the neutrino beam was not running).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and construction of the CMS Outer Tracker for the Phase-2 Upgrade

he High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of $3000-4000$~fb$^{-1}$ after 10 years of operation with peak instantaneous luminosity reaching about $5-7.5\times10^{34}$cm$^{-2}$s$^{-1}$. During Long Shutdown 3, several components of the CMS detector will undergo major changes, called Phase-2 upgrade, to be able to operate in the challenging environment of the HL-LHC. The current CMS silicon strip tracker has to be replaced with a new detector. The Phase-2 Outer Tracker (OT) will have higher radiation tolerance, higher granularity, and the capability to handle higher data rates compared to the current system. Another key feature of the OT will be to provide tracking information to the Level-1 (L1) trigger, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made out of modules with two closely spaced sensors read out by front-end ASICs, which can correlate hits in the two sensors creating short track segments called stubs. The stubs will be used for tracking in the L1 track finder. The modules come in two flavors: strip-strip (2S) and pixel-strip (PS), which contain different sensor configurations and multiple ASICs. In this contribution, the design of the CMS Phase-2 OT, the technological choices, and the quality assurance (QA) procedures used to ensure the functionality of the modules will be reported. The contribution will cover the first results with pre-production devices and the different aspects taken into account during the QA: from fulfilling the precision specification of the module assembly procedure to ensuring the proper communication between the different ASICs on the module. The module noise performance is also checked and the full module functionality is verified at different temperatures.

Zoi, Irene↗

SPITZER SECONDARY ECLIPSE DEPTHS WITH MULTIPLE INTRAPIXEL SENSITIVITY CORRECTION METHODS OBSERVATIONS OF WASP-13b, WASP-15b, WASP-16b, WASP-62b, AND HAT-P-22b

We measure the 4.5 μ m thermal emission of five transiting hot Jupiters, WASP-13b, WASP-15b, WASP-16b, WASP-62b, and HAT-P-22b using channel 2 of the Infrared Array Camera (IRAC) on the Spitzer Space Telescope . Significant intrapixel sensitivity variations in Spitzer IRAC data require careful correction in order to achieve precision on the order of several hundred parts per million (ppm) for the measurement of exoplanet secondary eclipses. We determine eclipse depths by first correcting the raw data using three independent data reduction methods. The Pixel Gain Map (PMAP), Nearest Neighbors (NNBR), and Pixel Level Decorrelation (PLD) each correct for the intrapixel sensitivity effect in Spitzer photometric time-series observations. The results from each methodology are compared against each other to establish if they reach a statistically equivalent result in every case and to evaluate their ability to minimize uncertainty in the measurement. We find that all three methods produce reliable results. For every planet examined here NNBR and PLD produce results that are in statistical agreement. However, the PMAP method appears to produce results in slight disagreement in cases where the stellar centroid is not kept consistently on the most well characterized area of the detector. We evaluate the ability of each method to reduce the scatter in the residuals as well as in the correlated noise in the corrected data. The NNBR and PLD methods consistently minimize both white and red noise levels and should be considered reliable and consistent. The planets in this study span equilibrium temperatures from 1100 to 2000 K and have brightness temperatures that require either high albedo or efficient recirculation. However, it is possible that other processes such as clouds or disequilibrium chemistry may also be responsible for producing these brightness temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗